APPLICATION SUBMITIAl CHECK LIST FOR NEW RESIDENCES .

Transcription

CHARTER TOWNSHIP OF HARRISONBUILDING DEPARTMENT38151 L'Anse Creuse Harrison Township, M148045-1996Building (586) 466-1430 Fax (586) 465-2618 www.harrison-township.org APPLICATION SUBMITIAl CHECK LISTFOR NEW RESIDENCES, SUBSTANTIAL REHABS, OR ADDITIONSSITE LOCATION:ZONING DISTRICT:(SITE ADDRESS OR PARCEL ID #)PLEASE SUBMIT THE FOLLOWING FOR PLAN REVIEW: BUILDING PERMIT APPLICATION COMPLETED, SIGNED AND SUBMITIED BY APPLICANT (WITH IDENTIFICATION).CONTRACTOR REGISTRATION FORM WITH REQUIRED DOCUMENTS (IF NOT CURRENTLY REGISTERED).ADDRESS ASSIGNMENT APPLICATION, IF NEEDED.PLOT PLAN, BY LICENSE SURVEYOR (3 COPIES) INCLUDE EXISTING AND PROPOSED STRUCTURES AS APPLICABLE;SEE ORDINANCE REQUIREMENTS.CONSTRUCTION PLANS (3 SETS) MINIMUM: FOUNDATION / ELEVATION/ WALL DETAILS/ FOOR PLANS - FORADDITIONS AND SUBSTANTIAL REHABS, PLEASE INCLUDE EXISTING AND PROPOSED FLOOR PLANS. COMPLETEREVIEW DETAILS ARE ON TOWNSHIP PLAN REVIEW CHECKLIST.SOIL TESTING REPORT REQUIRED FOR WATERFRONT PROPERTIES OR AS REQUESTED BY TOWNSHIP PLANREVIEWER.ENERGY CODE COMPLIANCE (INDICATE PRESCRIPTIVE OR PERFORMANCE METHOD, MAY BE ON PLANS ORSUBMIT 3 COPIES OF CERTIFICATE.ENGINEERED DOCUMENTATION; SUBMIT ENGINEER SIGNED AND SEALED DOCUMENTATION FOR ALLENGINEERED ASPECTS OF PROJECT. (AND AS RECEIVED LATER IN PROJECT) IE. TRUSSES, FLOOR JOIST,ELEVATORS.ELEVATION CERTIFICATE FOR WORK IN 100 YEAR FLOOD ZONES (REQUIRED FOR FINAL APPROVAL).MDEQ PERMIT ANY PERMIT ISSUED BY MICHIGAN DEPARTMENT OF ENVIROMENTAL QUALITY, IE. RIVER FLOODZONE, WETLANDS.SOIL EROSION SEDIMENTATION CONTROL PERMIT (ONE COPY OF PERMIT ISSUED BY MACOMB COUNTY DRAINCOMMISSION 586-469-5327), IF APPLICABLE.MACOMB COUNTY ROAD COMMISSION APPROACH/CULVERT PERMIT (ONE COPY OF PERMIT ISSUED BYMACOMB ROAD COMMISSION 586-463-8671), IF APPLICABLE.SEPTIC PERMIT (ONE COPY FROM MACOMB COUNTY HEALTH DEPARTMENT 586-463-5235) IF APPLICABLEAPPROVAL BY HOME OWNER OR CONDOMINIUM ASSOCIATION, AS REQUIRED.PLAN REVIEW FEE: .ZONING REVIEW FEE: ADDRESS ASSIGNMENT FEE: .CONTRACTOR REGISTRATION FEE:

APPLICATION SUBMITTAL CHECK LISTFOR NEW RESIDENTIAL CONSTRUCTION OR ADDITIONS*** IMPORTANT ADDITIONAL INFORMATION ***TOWNSHIP CODE OF ORDINANCES (& ZONING)https://www.municode.com/Iibra ry/ m i/ha rrison cha rter townsh ip/codes/code oC0 rdi nancesFEMA TECHNICAL BULLETINS chnicai-bulletinsWATER / SEWER TAP FEES (586-466-1425) MUST BE PAID PRIOR TO BUILDING PERMIT ISSUANCE.HVAC NOTICE:ADVANCE PREPARATION OF MECHANICAL DOCUMENTS IS RECOMMENDED IN ORDERTO AVOID PROJECT DELAYS.MECHANICAL PERMITS WILL NOT BE ISSUED UNTIL THE FOLLOWINGDOCUMENTATION IS RECEIVED AND APPROVED BY THE MECHANICAL INSPECTOR. COMPLIANCE WITH THE 2015 MRC SECTIONS M1401.3 (EQUIPMENT & APPLIANCE SIZING)& M1601.1 (DUCT DESIGN) OR 2012 MMC SECTION 312.1, AS APPLICABLE, IS MANDARTORYFOR ALL NEW CONSTRUCTION AND SUBSTANTIAL ADDITIONS/RENOVATIONS. IN ADDITION, HVAC DUCT DRAWINGS ARE REQUIRED. THESE DRAWINGS SHOULD BE NO LESSTHAN ONE QUARTER INCH (1/4") PER FOOT (1') SCALE AND SHOULD DEPICT ONLY DUCTWORKIN THE FOREGROUND AND ROOM LAYOUTS (WALLS, STAIRS, WINDOWS, DOORS, ETc.), IN THEBACKGROUND.DRAWINGS SUPERIMPOSED OVER ARCHITECTURAL DRAWINGS ARENOTACCEPTABLE DUE TO THE CLUTIER CREATED THEREBY. WHOLE-HOUSE MECHANICAL VENTILATION WORKSHEET MUST BE ATIACHED TO HVAC PERMITAPPLICATION (FORM IS ATIACHED TO THIS CHECKLIST).ELECTRICAL PERMIT AND APPROVED UFER INSPECTION IS REQUIRED FOR FOUNDATION INSPECTION. MICHIGAN ELECTRICAL CODE 250.52(A)(3) REQUIRES THAT REINFORCING RODS OR BARSLOCATED IN CONCRETE FOOTINGS ARE TO BE BONDED TO THE ELECTRICAL SYSTEM.ANELECTRICAL PERMIT MUST BE SECURED AND AN ELECTRICAL INSPECTION APPROVED PRIOR TOTHE PLACEMENT OF CONCRETE. (UFER UNDERGROUND FOUNDATION ELECTRICAL ROD)BACKFILL CERTIFICATE MUST SUBMIT FOR APPROVAL PRIOR TO BACKFILL INSPECTION, A PRELIMINARY GRADECERTIFICATE,(USINGATIACHED TOWNSHIPBACKFILLCERTIFICATEFORM)SETBACKS AND GRADE OF CONSTRUCTION, AND THE FEMA FLOOD ZONE.AND SEALED BY A REGISTERED STATE OF MICHIGAN LAND SURVEYOR.INDICATINGMUST BE SIGNED

TRUSS PLANS / ENGINEERED DOCUMENTATION TO BUILDING DEPARTMENT IE. MUST SUBMIT ENGINEER SIGNED AND SEALED TRUSS PLANS (OR ANY ENGINEEREDDOCUMENTATION) TO BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TOINSTALLATION AND ROUGH BUILDING INSPECTION. DO NOT LEAVE DOCUMENTS ON JOB SITEFOR INSPECTOR.FINAL GRADE AND AS-BUILT PLOT PLAN REQUIRED FOR ALL NEW CONSTRUCTION. FINAL GRADES AND SETBACKS ARE TO BE CONFIRMED BYREGISTERED LAND SURVEYOR ON AS-BUILT FINAL GRADE SURVEY DOCUMENT. A FEMAELEVATION CERTIFICATE IS ALSO REQUIRED FOR ALL NEW CONSTRUCTION, ADDITIONS, ANDSUBSTANTIAL REHABILITATIONS IN 100 YEAR FLOOD ZONES.MUST SUBMIT SURVEYS TOBUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO SCHEDULING INSPECTIONS.DTE NOTICE:BEGINNING MARCH 1 2016, ALL NEW, UPGRADED OR RELOCATED DTE ELECTRICCOMPANY RESIDENTIAL SERVICE LINES MUST BE INSTALLED UNDERGROUND.APPROVED CONSTRUCTION PLANS MUST BE ONSIlE FOR INSPECTIONS.ONLY THE PERMIT HOLDER MAY ACT ON THEIR PERMIT (IE. SCHEDULE INSPECTIONS OR PAY FEES FORADDITIONAL ITEMS). YOU MAY SUBMIT AN AUTHORIZATION LEDER TO APPOINT AN AGENT.

INSPECTIONS:INSPECTION LINE: 586-466-1402CALL BEFORE 3:00PM FOR NEXT WORKING DAY INSPECTIONSBUILDING AND ELECTRICAL INSPECTIONS ARE CONDUCTED MONDAY THROUGH FRIDAY. MECHANICAL ANDPLUMBING INSPECTIONS ARE CONDUCTED TUESDAY, WEDNESDAY, AND THURSDAY. INSPECTIONS BEGIN AT8:30AM UNTIL COMPLETED, (BEFORE 4:00PM). NO TIMES ARE GIVEN. IF YOU NEED TO CONTACT AN INSPECTORREGARDING YOUR INSPECTION, PLEASE CALL S86-466-1430 BEFORE 8:30AM.ALL PROJECTS ARE UNIQUE AND HAVE DIFFERENT INSPECTION REQUIREMENTS. HOWEVER, WE AREOFTEN ASKED TO PROVIDE AN EXAMPLE OF A GENERAL BUILDING INSPECTION SCHEDULE:1.FOOTING & ELECTRICAL (UFER)2.FOUNDATION WALL AND REBAR3.BACKFILL CERTIFICATE APPROVED (SUBMIT TOWNSHIP FORM SIGNED/SEALED BY SURVEYOR)4.BACKFILL INSPECTION5.OPEN JOIST (SUBMIT ENGINEER SIGNED SEALED SPECIFICATIONS & LAYOUTS)6.GARAGE TRENCH/FOOTING7.BASEMENT STONE (MUST HAVE APPROVED UNDER GROUND PLUMBING)8.GARAGE SAND/PORCH 5LAB9.SHEATHING10. FLASHING (MASONARY / STONE / BRICK LEDGE)11. FIREPLACE12. TRUSS PLANS APPROVED (SUBMIT ENGINEER SIGNED SEALED PLANS)13. ROUGH BUILDING (MUST OBTAIN ROUGH ELECTRICAL, MECHANCIAL, PLUMBING APPROVALS)14. INSULATION (MEUC COMPLIANCE CERTIFICATE MUST BE POSTED IN ELECTRICAL BOX)15. DRYWALL (FIRE SEPARATION)16. AS-BUILT & FINAL GRADE SURVEY / ELEVATION CERTIFICATE17. FINAL BUILDING (MUST OBTAIN FINAL ELECTRICAL, MECHANCIAL, PLUMBING APPROVALS)

1CHARTER TOWNSHIP OF HARRISONBUILDING DEPARTMENT38151 L'Anse Creuse Harrison Township, M148045-1996Building (586) 466-1430 Fax (586) 465-2618 www.harrison-township.org .NEW HOME RESIDENTIAL PLAN REVIEW CHECKLISTZONINGPlease visithttps://www.municode.com/library/mi/harrison charter township/codes/code of ordinancesSECTION 14.02ZONING DISTRICTSECTIONS 14.02 & 16.01 NSETBACKSBUILDING ELEVATIONSSECTION 54-158MINIMUM FLOOR AREASECTION 14.02LOT COVERAGE (STRUCTURES)SECTION 14.02IMPERVIOUS SURFACES (STRUCTURES & CONCRETE)SECTION 14.02SITE DRAINAGE, GRADES, LOCATION OF UTILITIESLOCATION OF MECHANICAL EQUIPMENTBUILDING HEIGHTINFORMATIONCOMPLIANT?YESNO(MAY BE SUBMITIED ON PLANS)SECTION 54-112SECTION 5.05SECTION 14.02(ABOVE REQUIREMENTS ON SIGNED SEALED PLOT PLAN)YESADMINISTRATION2015 MICHIGAN RESIDENTIAL CODEGROUND SNOW LOAD 25TR301.2(1)WIND SPEED 115TR301.2(1)FLOOD HAZARDSR309.3FIRE SEPARATION DISTANCETR302.1ENGINEERED DESIGNR301.1.3RESIDENTIAL PLAN REVIEW CHECKLISTNO

2YESBUILDING PLANNINGT302.6AITACHED GARAGE SEPARATIONR302.5.1GARAGE OPENING PROTECTIONGARAGE FLOOR SURFACE SLOPE OR DRAINR309.1TR303.1GLAZINGR303.3BATHROOM GLAZINGMINIMUM ROOM AREASR304CEILING HEIGHTSR305CLOTHES WASHER CONNECTIONR306.1HAZARDOUS GLAZINGR30B.4EMERGENCY ESCAPE OPENINGS BASEMENTSR310.1EMERGENCY ESCAPE OPENINGS BEDROOMSR310.1EMERGENCY ESCAPE HABITABLE AITICSR310.1EGRESS DOORR311.2R311.2.1INTERIOR DOORSLANDINGS AT DOORSR311.3BASEMENT / HABITABLE AITIC STAIRSR311.4HALLWAY MINIMUM WIDTHR311.6STAIRSR311. 7, R311.7.5, R311.7.6, R303.7 R303.BSMOKE DETECTORSR315CARBON MONOXIDE DETECTORSR315PROTECTION AGAINST DECAYR317GUARDRAILSHANDRAILSRESIDENTIAL PLAN REVIEW CHECKLISTR312.1R311.7.BNO

3FOOTINGS AND FOUNDATIONSFOOTING MINIMUM SIZER403.1.1MINIMUM DEPTHR403.1.4FOOTINGS ON OR ADJACENT TO SLOPESR403.1.7NOR406FOUNDATION WATERPROOFINGCRAWL SPACE VENTILATIONR408.1ACCESS TO CRAWL SPACER408.4FLOOD OPENINGS (FLOOD PLAIN ONLY)R408.7SOIL TEST (WATERFRONT)R401.4COMPRESSIVE STRENGTH OF CONCRETER402.2R403.1.6FOUNDATION ANCHORAGEFLOORSGRADING OF LUMBER (SPF #2 WILL BE DEFAULT)ENGINEERED LUMBER SPAN INFORMATIONGIRDER SPANSR502.1R501.2, R106.1.2R502.6/TR502.5(1}WIDE FLANGE BEAM/POST INFORMATIONRESIDENTIAL PLAN REVIEW CHECKLISTYESR405.1FOOTING DRAINAGESHEATHING DIMENSIONS / SPANSNOR404.1.2.2FOUNDATION REINFORCEMENTLUMBER JOIST SPANSYESR502.3.1(1}R503.2.1.1(1}

4CONCRETE FLOORS(BASEMENT, SLAB ON GRADE, & ATTACHED GARAGES)BASE COURSER506.2.2VAPOR RETARDERR506.2.3REINFORCEMENT SUPPORTR506.2.4YESNOYESNOYESNOR402.2COMPRESSIVE STRENGTH OF CONCRETEWALLSR602.10HEADER SIZES / GRADESSTUD SIZE, HEIGHT, & SPACINGR602.3(5)SHEATHING SIZET602.3(3)WR DRYWALL LIMITATIONSR702.3.8R602.10WALL BRACINGINSULATION & ENERGYPRESCRIPTIVEPERFORMANCE - DOCUMENTS PROVIDEDVAPOR RETARDERNll02.1.1, Nll02.1.4Nll05.4R601.3MECHANICAL - MANUAL JM1401.3MECHANICAL - MANUAL DM1401.3AIR LEAKAGE (REQUIRED AT FINAL C/O)Nll02.4RESIDENTIAL PLAN REVIEW CHECKLIST

5YESROOFS / CEILINGSR802.4, R802.5LUMBER SPECIESRAFTER SPANSR802.5CEILING JOIST SPANSR802.4CATHEDRAL CEILING-LOAD BEARING RIDGE / CONNECTORSWOOD TRUSS DESIGN (DEFERRED SUBMITIALS)TRUSS TIE DOWNSROOF SHEATHING SPANSROOF COVERINGSROOF VENTILATIONSCHIMNEYS / FIREPLACESRESIDENTIAL PLAN REVIEW 806.3, R806.5, R806.1CH 10NO

dte notice: beginning march 1 2016, all new, upgraded or relocated dte electric company residential service lines mustbe installed underground. approved construction plans mustbe onsile for inspections. only the permit holder mayact on their permit (ie