CyFlow SL 3 - Purdue University Cytometry Laboratories

Transcription

CyFlow SL 3Healthcare ImmunologyPortable FCM System for Routine HIV/AIDS Monitoring of Adultand Pediatric Patients

01COMPANYFlow Cytometry made in GermanyNew sophisticated applications and increasing requirementsfor reliable results in research and clinical routine within theshortest possible time - The challenge for flow cytometryinstrumentation, automation, and software.A well-established network of subsidiariesand distributors in more than 60 countriesworldwide characterizes Partec’s commitment to the increasing focus and needfor global access to Flow Cytometryinstrumentation and application e than 35 Years of Experienceand Professional ExpertisePartec – pioneer in Flow Cytometry since 1968 – respondsto these requirements with the new generation ofWindows XP based CyFlow and PAS FCM systemsfeaturing innovative computer controlled flow systems,modular optical systems with advanced PMTs for alloptical channels, most modern computer and digitalelectronic technologies including fast and precise 16 bitADC converters and realtime data acquisition and display.

02HIGHLIGHTSCyFlow SL 3 FCM Systemultracompact and fully equipped mobile/portable instrumentdimensions [cm]: L 43 x H 16 x D 37highest stability/robustness and highest precisionsingle platform True Volumetric Absolute Counting (TVAC)high fluorescence sensitivity 50 MESF (PE)power connection: regular 100/240 V AC or car battery andsolar panels (12 V DC)set-up time: 5 minutesvolumetric absolute counting of CD4, CD45, CD8, CD3price per CD4 test: EUR 1.75price per CD4% test: EUR 2.50capacity: up to 250 CD4 or CD4% tests per dayprice for CyFlow SL 3 including 300 tests: EUR 20,850

03TECHNOLOGYCyFlow SL 3 FCM SystemThe ultracompact and portable CyFlow SL 3 providesmost accurate and uniquely affordable absolute cell counting in HIV/AIDS monitoring, both for adults and children.Compactprecision analysis is maintained by the extraordinary long lifeThe CyFlow SL 3 is a fully equipped 3 parameter (SSC 2 colourfluorescence) portable / desktop flow cytometer. It contains a solidstate laser for green excitation. In the optionally available blue lasertime of solid state lasers.Power Connectionversion it is fully compatible with standard flow cytometers used in clin- The CyFlow SL 3 does not need particular power line connections,ical and research immunology. Its small size and robustness makes it runs on regular 100/240 V AC as well as 12 V DC. For field studies,the CyFlow SL 3 easy to place even in laboratories with limited space in remote areas, and places with unstable power lines, the CyFlow and limited resources. It is the perfect device to take over the routine SL 3 can easily be connected to a car or solar panels. It is perfectlypatient monitoring from more expensive and service demanding large prepared for scientific expeditions, field studies, and as mobile flowflow cytometers; dramatical cut down of running costs is achieved.cytometer for decentralized use close to patients in hospitals andsmall medical service stations.TMHigh Stability alignFree TechnologyThe complete optical system of the CyFlow SL 3 is designed as onePrice/Performance Ratiosolid metal block. Time consuming installation and optical checks, The CyFlow SL 3 opens a new era of flow cytometry, it supports allrealignments of lasers and readjustments are no longer required applications as known from traditional large flow cytometers atdue to the unique Partec alignFreeTM Technology.equipment costs roughly half the price of them. In addition, serviceand running costs as well as maintenance are reduced to aHigh Precisionneglectible minimum near zero.The solid state laser of CyFlow SL 3 shows a unique short and longterm stability superior over water and air cooled gas lasers. HighSelection of Fluorochromes for the CyFlow SL 3 Light Source System

FLUORESCENCE AND SIDE SCATTERThe unique Partec quartz flow cuvette is the heart of theCyFlow SL 3, ensuring that particles and cells cross theexcitation light with best possible precision.The design of the flow cuvette incorporates more than 35for all parameters. The sample is transported with help of ayears of experience in handling fluids with sub-micrometercomputer controlled digital syringe pump, part of a virtuallyand nanoliter precision. Thanks to the optical and mechanicalcross-contamination-free fluid system.precision of the flow cuvette, superior results are guaranteedThe True Volumetric Absolute Counting (TVAC) is aunique feature of all Partec Flow Cytometers, offeringhighest absolute counting precision and accuracy.The CyFlow SL 3 analyses concentrations of any particle orAlternatively, a well defined volume of free choice involvingcell subpopulations of interest using True Volumetricthe digital sample speed control can be used. Benefits ofAbsolute Counting. This unique method is solely based onTrue Volumetric Absolute Counting:the fundamental definition of absolute counting respectivelythe particle concentration (c) which is equal to the countednumber (N) of particles (e.g. cells) in a given volume (V), c N / V. In the CyFlow SL 3, the volume is measured directly bymechanical means, rather than by calibration with expensivebeads with a—sometimes doubtful—”given” nominal concentration. Thus, the precision of volume measurement isdefined by a fixed mechanical design, eliminating any errorsrelated to varying bead concentrations or bead aggregation.The CyFlow SL 3 allows the analysis of a fixed volume asdefined by the distance between two platinum electrodesreaching into the sample tube with a given diameter.digital volumetric precision bymechanical design: CV 2 %no errors related to calibrationno additional time and preparation stepsfor reference beads or haematologyreference countno expenses for calibration beadsno separate haematology counter required

04ANALYZECyFlow SL 3 FCM SystemGet your accurate and precise counting results fromthe CyFlow SL 3 for routine adult and pediatric patientmonitoring within shortest possible time.The CyFlow SL 3 is designed to perform any kind of 3 parameterThe results are directly displayed in terms of:cell analysis and in particular to be used in routine HIV/AIDS followup diagnostic.In this field the unique feature is to deliver – out of only one sample tube – the absolute number (concentration) of leukocytes, theabsolute number (concentration) of lymphocytes, the absolutenumber of CD4 T-lymphocytes and the percentage of CD4 Tlymphocytes from all leukocytes and all lymphocytes as well.concentration of CD4 T-lymphocytesconcentration of all leukocytesconcentration of all lymphocytespercentage of CD4 T-lymphocytesamong all lymphocytespercentage of lymphocytes among allleukocytesA breakthrough for the routine application in HIV/AIDS monitoringis reached by the development of an ultimately easy-to-performblood preparation protocol. This protocol does not need any criticalpipetting step. Therefore, the main source of error is eliminated.mAbFig. 1: CD4 ProtocolAnalysis of absolute CD4 T-Lymphocyte cell concentration from whole blood.Fig. 2: CD4% Protocol2-colour analysis of CD4 / TLC/CD45 with CyFlow SL 3 from whole blood.

Principle of Partec True Volumetric Absolute CountingWith this protocol a breakthrough for the analysis of pediatric bloodsamples is derived. With this feature the CyFlow SL 3 is superior toother CD4 counting techniques.HIV/AIDS monitoring is one of the main applications of the CyFlow SL 3. The fast increasing number of patients who need a lifelongmonitoring of the disease demand powerful techniques capable torun many samples per day. The CyFlow SL 3 has the capability toanalyse more than 250 blood samples per day. It allows to analysethe patient’s CD4 lymphocyte count at costs close to EUR 2.50 onlywithout the loss of accuracy. For the first time a full flow cytometricanalysis (“gold standard” according to WHO) can be offered everywhere in the developing countries.Fig. 4: Automatically generated clinical report from CD4% analysis: Direct result displayof absolute CD4 T-cell count (population R1, left), total lymphocyte count (population R2,middle), and total WBC count (white blood cells / leukoytes - population RN1, right).Fig. 3: Analysis of absolute CD4 T-Lymphocyte cell concentration from whole blood.CD4 counting result: 622 CD4 / µlFig. 5: CD4 countingComparison to conventional single platform results employing reference beads.(Data kindly provided by Dr. L.G. Lehman, University of Douala, Cameroon)References:Cassens, U. et al.: A novel true volumetric method for the determination of residual leucocytes in blood components”, Vox Sanguinis 2002; 82, 198-206Greve, B. et al.: A New No-Lyse, No Wash Flow-Cytometric Method for the Determination of CD4 T Cells in Blood Samples”, Transfus Med Hemother 2003; 30:8-13Cassens, U. et al.: “Simplified True Volumetric Flow Cytometry Allows Worldwide Feasible and Accurate Determination of CD4 T-Lymphocytes in Patients with AIDS”, Antiviral Therapy 2004; 9:395-405Imade, G.E. et al: “Comparison of a New, Affordable Flow Cytometric Method and the Manual Magnetic Bead Technique for CD4 T-Lymphocyte Counting in a Northern Nigerian Setting,“ Clinical and Diagnostic LaboratoryImmunology, Jan. 2005, pp. 224-227Greve, B. et al: “New Protocols to Follow Up HIV-induced Immune Impairment in Paediatric Samples,“ Busines Briefing: Long-Term Healthcare:2005, pp. 32-35

05 SPECIFICATIONSwww.cyclos-design.deCyFlow SL 3 FCM SystemGENERALELECTRONICSparallel signal processing for each of the opticalThe CyFlow SL 3 is a fully-equipped portable /desktop flow cytometer with excitation in green.channels with selectable linear, 3- or 4-decadeIt analyses up to three optical parameters (SSClogarithmic scaleand 2 fluorescences) plus time parameter. It per- pulse height, area and width analysis fordoublet discriminationforms both fluorescence analysis and absolute16 bit analog-to-digital converters, trigger oncell counting without the need for referenceany parameter or parameter combinationsbeads.Word or MS Excel document. FCS flow cytometryfile standard. Network connection to laboratoryinformation systems (LIS), PCs, and AppleMacintosh.POWERREQUIREMENTS100/ 240 V AC, 60 VA, 50/60 Hz or 12 Volts DC/5AThe instrument is equipped with a green solidstate laser light source. Optionally available: reddiode laser, blue solid state laser, UV laser, violetdiode laser.OPTICSModular optical system with 1 to 3 optical parameters. Each parameter is equipped with a photomultiplier tube (PMT) and integrated electronicpreamplifier. Colour CCD camera for video flowmonitoring.FLOW SYSTEMSynthetic quartz flow cuvette (channel dimensions: 200 µm x 350 µm) for laminar sample flow.True Volumetric Absolute Counting based onprecise counting and fluid volume measurement.Computer controlled precision syringe pump forcontamination-free sample transport andvolumetric absolute counting, pump speedcontinuously adjustable from 0–1200 µl/min,sheath fluid pressure continuously adjustablefrom 0–500 mbar. Fluid level indicators for fullwaste and low sheath fluid.COMPUTERProcessor Pentium 3.2 GHz, 512 MB RAMHarddisk 160 GB15“ TFT (17“, 19“ optionally available)Floppy disk drive 1.44 MB and DVD / CD-RWcombo driveMonitor, keyboard and mouseMicrosoft WindowsTM, Office Notebook optionalSOFTWAREORDER NUMBERCyFlow SL 3CY-S-1023ReagentsPartec CD4 easy count kit (100 tests)Partec CD4% easy count kit (100 tests)for CyFlow SL 305-840105-8405Partec CD8 easy count kit (100 tests)Partec CD3 easy count kit (100 tests)05-880105-8301Partec FloMax software based on the WindowsTMoperating system for multi-parametric dataacquisition, display, data analysis, and instrument control. Simultaneous representation insingle parameter histograms or correlated dualparameter plots during data acquisition. TrueVolumetric Absolute Counting with determinationof cell concentration, concentration of subpopulations for each region or gate, reselection ofsubpopulations for absolute counting. Realtimeacquisition. Individual instrument setups anacquisition displays can be saved in setup files.Multi-tube analysis can be predefined in panels.Automated panel acquisition. Report module:automated multi-tube report generation as MSFor in vitrodiagnostic use.Partec GmbH · Otto-Hahn-Straße 32 · D-48161 Münster · GermanyFon 49 25 34 80 08-0 · Fax 49 25 34 80 08-90Mail: info@partec.com · Web: www.partec.com04.06LIGHT SOURCES

Partec – pioneer in Flow Cytometry since 1968 – responds to these requirements with the new generation of Windows XP based CyFlow and PAS FCM systems featuring innovative computer controlled flow systems, modular optical systems with advanced PMTs f