ADDENDUM110 Armour RoadNorth Kansas City, Missouri 64116Tel. 816.300.4101Fax. 816.300.4102www.wskfarch.comArchitecture·Interior Design·IllustratIon·PlanningAddendum No.: THREE (003) revisedProject: Lee’s Summit Fire #3Project No.: 17016Date: August 3, 2018This Addendum is issued to all registered plan holders pursuant to the Instructions to Bidders andConditions of the Contract. This Addendum serves to clarify, revise, and supersede information in theProject Manual, Drawings, and previously issued Addenda. Portions of the Addendum affecting theContract Documents will be incorporated into the Contract by enumeration of the Addendum in theOwner/Contractor Agreement.The Bidder shall acknowledge receipt of this Addendum in the appropriate space on the Bid Form.A.SPECIFICATIONS1) SECTION 072419 – WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)a) Revise 2.1 A. to read:A.Basis of Design: StoTherm ci Classic as manufactured by Sto Americas, 3800 Camp Creek Parkway SW,Atlanta, Georgia 30331 or approved equal.2) SECTION 084113 – ALUMINUM-FRAMED ENTRANCES & STOREFRONTSa) Revise 2.4 A. to read:B.Basis of Design: D502 Wide Stile 2” ThermaStile as manufactured by EFCO Corporation, Monet, MO65708 or approved equal.1.Other manufacturers:a.Manko Window Systems, Inc. Manhattan, KS; XPT Seriesb) Remove Manko Window Systems, Inc. Manhattan, KS; 150H as an approved equal.Page 1 of 4

Project Name: Lee’s Summit Fire #3Addendum No. ThreeProject No.: 170164) SECTION 085113 – ALUMINUM WINDOWSa) Revise 2.3 as follows:Add 2.4, B to read:C.Dividers (False Muntins): Provide extruded-aluminum divider grilles in designs indicated for each sash lite.1.2.3.Type: Permanently located between insulating-glass lites.Pattern: As indicated on Drawings.Profile: As selected by Architect from manufacturer's full range.5) SECTION 101463.13 – LED ELECTRONIC MESSAGE SIGNAGEa) Add the following specification to the project manual in its entirety:i)Basis of Design: Galaxy GS6, 19.8MM, Digital Display Unit (single face) as manufactured byDaktronics, 201 Daktronics Drive, Brookings, SD. Aluminum ventilated, front access, semi-gloss blackcabinet shall be approximately 2’-7” H x 5’5” W with a display area of approximately 2’-1” H x 5’-2”W. Display shall be GS6 – AAAxBBB-CC (character display) with red LED color lighting weighingapproximately 100 pounds. Unit to be sealed, with quick connects, high-contrast louvers, redundantmodule signal, shallow cabinet depth and narrow cabinet borders. Unit to be furnished complete with allnecessary software to have a fully functional and operating display unit.A.B.C.D.E.F.G.H.I.J.K.L.M.N.O.P.Character Height: 5.5 inchesLine Spacing: 19.8 mmPixel Configuration: Monochrome - 1 red or 1 amber; RGB – 1 red, 1 green, 1 blueMaximum Brightness: Monochrome Red, 4.500 nits or monochrome amber, 6,000 nits, RGB,11,000 nitsMonochrome Color Capability: 4,096 shades of red or amberOptimal Viewing Angle: 140 degrees horizontal x 70 degrees verticalReadability Angle: 160 degrees horizontal x 90 degrees verticalMinimum Viewing Distance: 45 feetLED Lifetime: 100,000 hours plus (estimated)Contrast Enhancement: Non-reflective black louvers and moduleMessage Capability: Text, graphics, logos, basic animation, video clips, multiple font styles andsizesControl Software: Venus Control SuitePower: 120, 120/240 VAC Single PhaseDisplay Dimming: 64 levels (automated, scheduled or manual)Communication: Ethernet Fiber Optic, Ethernet Bridge Radio, Remote Cellular, Ethernet CAT5(owner’s choice)Operating Temperature: -40 Degrees F to 120 Degrees F w/99 percent RH non-condensingPage 2 of 4

Project Name: Lee’s Summit Fire #3Addendum No. ThreeProject No.: 17016Q. Compliance: UL and cUL Listed, UL-Energy Verified, FCC complianceFurnish and install unit as depicted on the Site Plan. Unit shall have a 1-year warranty that includes allparts and labor for elements of the display unit that fail to perform during the 1-year warrantyperiod. This is considered a turn-key scope of work to furnish and install and make operational.6) SECTION 095113 – ACOUSTICAL CEILINGSa) Add line ‘e’ to subsection F to 3.3 INSTALLATION to read as follows:e.B.Add additional/supplemental supports as needed to continue pattern of tectum installation and toallow for attachment of panels every 24” on center per manufacturer’s recommendations.DRAWINGS1) SHEET C5.0a) The Domestic Water line changed from 2” to 3” size.b) A note for the Oil/Sand Separator references the MEP plans has been added.c) Sections of sanitary sewer pipe have been specified as SDR-26.2) SHEET C7.0a) Added 2 additional evergreen trees to screen the equipment pads on the West side of the building.b) Added 4 shrubs to screen the equipment pad along the south face of the building.3) SHEET A0.01a) A8 – CODE PLAN: The plan was updated to show the door swings on Doors 115 and 127Aswinging in the direction of egress.4) SHEET A1.01a) A10 – FIRST FLOOR PLAN:i) The door swings on Doors 115 and 127A were reversed. Refer to the attached sheet fordimensions of this revision.ii) Door 105 has been reduced in size; refer to attached sheet and Sheet A6.01.5) SHEET A1.02a) A10 – FIRST FLOOR PLAN:i) The door swings on Doors 115 and 127A were reversed. Refer to the attached sheet for thisrevision.ii) Door 105 has been reduced in size; refer to attached sheet and Sheet A6.01.Page 3 of 4

Project Name: Lee’s Summit Fire #3Addendum No. ThreeProject No.: 170167) SHEET A6.01a) Door 105 to change from 6’-0” x 7’-0” pair of doors to 5’-0” x 7’-0” pair of doors.8) SHEET E1.01a) Added C1 exterior downlight in soffit above patio stairs.9) SHEET E3.01a) Added fire alarm relay in IT room for release of secure doors upon activation of the fire alarmsystem.C.APPROVED EQUALS1) NOTE: Adding a product/manufacturer to the approved equals list does not remove the product’sresponsibility in meeting the specification. All products MUST meet specification.2) SECTION 085113 – ALUMINUM WINDOWSa) The following manufacturer and product has been approved as an equal under Part 2, 2.1, A.i) Manko Window Systems, Inc. – 800 Series3) SECTION 095113 – ACOUSTICAL PANEL CEILINGSa) The following manufacturer has been approved as an equal under Part 2.3, A, 1:i) ASI StrandTec Direct Attached Panels, Factory painted white, 1-3/8” thick, 23-3/4”x48” panelsize, bevel edgesATTACHMENTS:DRAWING SHEETS:C5.0, C7.0, A1.01, A1.02, E1.01, E3.01Page 4 of 4

765432UTILITY NOTES:EVAKHCORAMSHGTKMENESATBACEESRNGATEILDIU10' WBK 3TRONTBACES15' FINGARKP'02INSTALL 50 LF OF 4" SDR26 SANITARY SEWER LINE@ 7.82% SLOPE INSTALL SANITARY SEWERCLEAN OUT, FL 974.07 INSTALL 30 LF OF 4" SDR 26 SANITARYSEWER LINE @ 5.66% SLOPE.REFER TO MEP PLANS FORINSTALLATION OF OIL/SANDSEPARATOR. TO BE INSTALLEDPER MANUFACTURERSSPECIFICATIONS AND CITY OFLEE'S SUMMIT STANDARDS.SEE CITY PLANS FORCONNECTION LOCATION.FL 975.5 WATER METER TO BEINSTALLED BY OTHERS.3INSTALL 25 LF OF 4" SDR 26 SANITARYSEWER LINE @ 5.48% SLOPE.INSTALL 56 LF OF 3" DOMESTICWATER LINE. SEE NOTE #9 FORMORE INFORMATION.SEE MEP PLANS FORCONNECTION LOCATION. FL@ BUILDING 977.50 INSTALL 56 LF OF 6" FIREWATER LINE. SEE NOTE #9FOR MORE INFORMATION.FL 977.50 FL 976.03 PIPE C24SEE MEP PLANS FOR MOREINFORMATION ON ATS,TRANSFORMER ANDGENERATOR.PIPE C25PIPE C1PIPE C2PIPE C3PIPE A1SEE SHEET C5.1 FORPROFILE VIEWPIPE B1PIPE A3SEE SHEET C5.1 FORPROFILE VIEWPIPE C11AREAINLET 3DPIPE C19FL 975.76 PIPE B2SEE SHEET C5.1 FORPROFILE VIEWPIPE C14PIPE C13ALTERNATE/BACKUP PATIODRAINAGE SOLUTIONREFER TO ARCHITECTURAL DETAILSFL 972.22 PIPE C12PIPE B3SEE SHEET C5.1 FORPROFILE VIEW14' INGRESS/EGRESS EASEMENT6' PARKING SETBACKPIPE A END SECTION12" HDPE END SECTIONWITH TOEWALLFL 970.00 DETENTION POND: OUTLET STRUCTURERIM ELEV. 973.60FL ELEV 967.00SEE SHEET C9.0 FORMORE INFORMATION14' INGRESS/EGRESS EASEMENTB12/1/2017 2:17:26 PMM:\2017\17016 - Lee's SummitFire Station 3\1 - Drawings\17016preliminary design plan.rvtCONTACT AFFECTED OWNER(S) A MINIMUM OF 24 HOURS PRIOR TO HALTING OF UTILITY SERVICES. UNDER NO CIRCUMSTANCE SHALL ANY UTILITY SERVICE BE DISCONTINUED FORMORE THAN (1) 8-HOUR PERIOD, CONTINGENT UPON THE WORK BEING PERFORMED AT NIGHT.6.REFER TO ELECTRICAL/MECHANICAL ENGINEER'S PLANS FOR ALL ROUTING AND CONNECTIONS TO BUILDINGS AND ALL DESIGN AND SPECIFICATIONS OF SITE LIGHTING.7.THE CONTRACTOR SHALL DISPOSE OF ANY ROCK EXCAVATED FROM TRENCHES AND STRUCTURES OFFSITE UNLESS OTHERWISE DIRECTED BY THE ENGINEER. TRENCH WIDTH USED INCOMPUTING ROCK EXCAVATION SHALL BE THE OUTSIDE DIAMETER OF PIPE PLUS 12-INCHES.8.THE PRICE BID FOR SANITARY SERVICE LINE, IN PLACE, SHALL INCLUDE TRENCHING, LAYING PIPE AND FITTINGS, BEDDING MATERIALS, BACKFILL, MARKING AND COMPACTION.9.CONNECT WATER LINES WITH APPROPRIATE TEE JOINTS & VALVE BOXES PER CITY OF LEE'S SUMMIT STANDARDS. CONTRACTOR SHALL OBTAIN ALL CITY STANDARDS ANDSPECIFICATIONS FOR USE ON THIS PROJECT. CONTACT THE CITY OF LEE'S SUMMIT WATER DEPARTMENT REPRESENTATIVE PRIOR TO ANY WATER LINE INSTALLATION.DETENTION POND: PIPE P-1SEE SHEET C9.0 FOR PROFILE.CITY OF LEE'S SUMMITWATER UTILITIES DEPARTMENT616 N.E. DOUGLASLEE'S SUMMIT, MO. 64063816-969-1940AT&T215 N. SPRING STINDEPENDENCE, MO 64050JOHN CORNICK 816-325-5615CITY OF LEE'S SUMMITSTREET/STORM WATER DEPARTMENT220 SE GREEN ST.LEE'S SUMMIT, MO. 64063PUBLIC WORKS OPERATIONS 816-969-1870PIPE A1: BEGINNING FL ELEV 976.03 INSTALL 44 LF OF 8" HDPE @ 1.9% SLOPE.ENDING FL ELEV 975.20 CONNECT TO A2 WITH 8" TO 10" ADAPTERPIPE A2: BEGINNING FL ELEV 975.20 INSTALL 56 LF OF 10" HDPE @ 1.9% SLOPE.ENDING FL ELEV 974.14 CONNECT TO A3 WITH 10" TO 12" 90 ELBOWPIPE A3: BEGINNING FL ELEV 974.14 INSTALL 218 LF OF 12" HDPE @ 1.9% SLOPE.ENDING FL ELEV 970.00 CONNECT TO OUTFALL END SECTIONPIPE C1: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO A1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 976.03 PIPE C2: BEGINNING FL ELEV 978.50 INSTALL 7.4 LF OF 6" HDPECONNECT TO A1 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 975.90 PIPE C3: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO A1 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 975.87 PIPE C4: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO A1 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 975.34 PIPE C5: BEGINNING FL ELEV 978.50 INSTALL 7.4 LF OF 6" HDPECONNECT TO A1 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 975.32 PIPE C6: BEGINNING FL ELEV 978.50 INSTALL 7.4 LF OF 6" HDPECONNECT TO A2 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 974.85 DETENTION POND: END SECTION15" RCP END SECTION WITH TOEWALL.SEE SHEET C9.0 FOR PROFILE.20' REAR BUFFER & 100 YR WSELLIMITSPECTRUM CABLE8221 W. 119TH STREETOVERLAND PARK, KS 66213ROY BELLIS913-643-1914PIPE B1: BEGINNING FL ELEV 977.5 INSTALL 129 LF OF 6" HDPE @ 1.34% SLOPE.ENDING FL ELEV 975.76 CONNECT TO B2 WITH 6" TO 8" 90 ELBOWPIPE B2: BEGINNING FL ELEV 975.76 INSTALL 110 LF OF 8" HDPE @ 1.7% SLOPE.ENDING FL ELEV 973.89 CONNECT TO B3 WITH 8" TO 10" ADAPTERPIPE B3: BEGINNING FL ELEV 973.89 INSTALL 98.5 LF OF 10" HDPE @ 1.7% SLOPE.ENDING FL ELEV 972.22 CONNECT TO A3 WITH 10" TO 12" TEE AND CLEANOUTCA5.MISSOURI GAS ENERGY3025 SE CLOVER DR.LEE'S SUMMIT, MO. 64055JON HARREL 816-969-2298PIPE C10FL 973.89 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL METHODS NEEDED DURING THE INSTALLATION OR CONSTRUCTION OF ANY UTILITIES OR RELATED ITEMS. AT NOTIME SHALL A DRIVE LANE BE CLOSED TO THRU TRAFFIC. CONTRACTOR SHALL MAINTAIN AT LEAST 15 FEET OF MINIMUM DRIVE WIDTH TO ACCOMMODATE TRAFFIC FLOW.KCP&L1300 SE HAMBLEN RD.LEE'S SUMMIT, MO 64081HEATH LENAHAN 816-251-2647PIPE C7PIPE C21PIPE C154.Williams SpurgeonKuhl & FreshnockArchitects, Inc. 2018LIST OF UTILITIESPIPE C9PIPE C16ALL ROUTING OF UNDERGROUND ELECTRIC LINE TO BE VERIFIED WITH APPROPRIATE PROVIDER PRIOR TO INSTALLATION. ANY AND ALL PAVEMENT, TURF, ETC. REMOVED FORINSTALLATION SHALL BE REPLACED AS PREVIOUSLY EXISTED.PIPE C6PIPE A2SEE SHEET C5.1 FORPROFILE VIEWPIPE C22PIPE C203.14. CONTRACTOR SHALL COORDINATE ROUTING OF EXISTING AND PROPOSED ELECTRICAL, GAS, CABLE AND TELEPHONE LINES WITH THE APPROPRIATE SERVICE PROVIDER, OWNER,SUB-CONTRACTOR AND ELECTRICAL/MECHANICAL ENGINEERS PLANS TO ENSURE THESE SERVICES ARE NOT INTERRUPTED AT SURROUNDING BUILDINGS.PIPE C8PIPE C17ALL INSTALLATION AND MATERIALS TO BE IN COMPLIANCE WITH CITY OF LEE'S SUMMIT, MISSOURI CODES AND SPECIFICATIONS. CONTRACTOR SHALL VERIFY ALL CODES ANDREGULATIONS.13. CONNECT SANITARY LINES PER CITY OF LEE'S SUMMIT STANDARDS. CONTRACTOR SHALL OBTAIN ALL CITY STANDARDS AND SPECIFICATIONS FOR USE ON THIS PROJECT. ALL SANITARYSEWER MAINS AND SERVICE LINES SHALL MAINTAIN A MINIMUM COVER OF 30-INCHES.PIPE C5PIPE C23PIPE C182.3 08/03/201812. ALL WATER MAINS SHALL MAINTAIN A MINIMUM COVER OF 42-INCHES.FL 974.14 PIPE C4ALL ROUTING AND INSTALLATION OF PROPOSED UTILITIES (TELEPHONE, GAS, WATER, CABLE, ELECTRICAL, ETC.) SHALL BE COORDINATED BETWEEN THE CONTRACTOR AND THEAPPROPRIATE UTILITY PROVIDER. ALL UTILITY ROUTING SHALL BE APPROVED BY THE OWNER AND THE APPROPRIATE UTILITY PROVIDER PRIOR TO INSTALLATION. ANY PROPOSEDUTILITY ROUTING DESIGNATED ON THESE DOCUMENTS ARE FOR GENERAL GUIDELINES ONLY UNLESS OTHERWISE SPECIFIED. BARTLETT & WEST, INC. ASSUMES NO LIABILITY FORIMPROPER ROUTING OR CONNECTIONS TO EXISTING UTILITIES.07/25/2018REVISIONS11. WATER MAINS SHALL MAINTAIN 24-INCHES OF VERTICAL CLEARANCE BETWEEN THE OUTSIDE OF THE WATER MAIN TO THE OUTSIDE OF THE SANITARY MAIN. CONTRACTOR SHALL BEREQUIRED TO VERIFY AND FOLLOW ALL CURRENT STATE DEPARTMENT OF HEALTH AND ENVIRONMENT JURISDICTION REGULATIONS.AREAINLET 2FL 975.20 FDC LOCATED ON BUILDING.REFER TO MEP PLANS FORDETAILS.EAREAINLET 1PIPE D1FHYDRANT TO BEINSTALLED BY OTHERS.www.bartlettwest.comJOB NUMBER17016ISSUE DATE10. WATER MAINS SHALL BE INSTALLED AT LEAST 10 FEET HORIZONTALLY FROM SANITARY SEWER MAINS AND AT LEAST 10 FEET HORIZONTALLY FROM STORM SEWER. THE DISTANCESHALL BE MEASURED EDGE OF PIPE TO EDGE OF PIPE. CONTRACTOR SHALL BE REQUIRED TO VERIFY AND FOLLOW ALL CURRENT STATE DEPARTMENT OF HEALTH AND ENVIRONMENTJURISDICTION REGULATIONS.REFER TO BID PACKAGE 2.532 LF OF 6" SANITARYSEWER LINE TO BE INSTALLEDBY OTHERS @ 4.6% SLOPE PIPE D23LOCATION OF PULL BOXFOR FIBER CONDUIT.REFER TO MEP FORBUILDING CONNECTIONS.1.1PIPE C7: BEGINNING FL ELEV 978.50 INSTALL 23 LF OF 6" HDPECONNECT TO C8 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 977.94 PIPE C8: BEGINNING FL ELEV 978.50 INSTALL 23 LF OF 6" HDPECONNECT TO A3 WITH 6"x12" TEE AND CLEANOUT.ENDING FL ELEV 973.52 PIPE C9: BEGINNING FL ELEV 978.50 INSTALL 20 LF OF 6" HDPECONNECT TO A3 WITH 6"x12" TEE AND CLEANOUT.ENDING FL ELEV 973.31PIPE C10: BEGINNING FL ELEV 978.50 INSTALL 20 LF OF 6" HDPECONNECT TO A3 WITH 6"x12" TEE AND CLEANOUT.ENDING FL ELEV 972.85 PIPE C11: BEGINNING FL ELEV 978.50 INSTALL 26 LF OF 6" HDPECONNECT TO C10 WITH 6"x6" TEE AND CLEANOUTENDING FL ELEV 978.02 PIPE C12: BEGINNING FL ELEV 974.50 INSTALL 4 LF OF 6" HDPECONNECT TO B3 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 972.38 PIPE C13: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B3 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 972.74 PIPE C14: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B3 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 973.11 PIPE C15: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B3 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 973.46 PIPE C16: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B2 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 973.89 PIPE C17: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B2 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 974.28 PIPE C18: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B2 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 974.89 PIPE C19: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B2 WITH 6"x8" TEE AND CLEANOUT.ENDING FL ELEV 975.08 PIPE C20: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 975.83 PIPE C21: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 976.15 PIPE C22: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 976.47 PIPE C23: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 976.79 EMERGENCY PHONE NUMBERS:LEE'S SUMMIT POLICE 969-1700LEE'S SUMMIT FIRE DEPT. 969-1300LEE'S SUMMIT PUBLIC WORKS INSPECTOR969-1817PIPE C24: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 977.11 PIPE C25: BEGINNING FL ELEV 978.50 INSTALL 3 LF OF 6" HDPECONNECT TO B1 WITH 6"x6" TEE AND CLEANOUT.ENDING FL ELEV 977.50 PIPE D1: BEGINNING FL ELEV 978.0 INSTALL 24 LF OF 6" HDPECONNECT TO A2 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 975.20 PIPE D2: BEGINNING FL ELEV 978.0 INSTALL 24 LF OF 6" HDPECONNECT TO A2 WITH 6"x10" TEE AND CLEANOUT.ENDING FL ELEV 974.47 AREA INLET 1: 3'x3' AREA INLETSURFACE ELEV 980.25FL OUT (S) 978.00AREA INLET 2: 3'x3' AREA INLETSURFACE ELEV 980.25FL OUT (S) 978.00AREA INLET 3: 6"X6" AREA INLETSURFACE ELEV 981.25FL OUT (S) 978.50PIPE A END SECTION : 12" HDPE END SECTIONELEV 970.00DETENTION POND: OUTLET STRUCTUREREFER TO C9.0 FOR DETAILSSURFACE ELEV 973.60FL OUT (SE) 967.00110 Armour Road North Kansas City, Missouri 64116 Tel. 816.300.4101 Fax 816.300.41028PRYOR ROADLEE'S SUMMIT, MO 640819LEE'S SUMMIT STATION #310DETENTION POND: 15" CMP END SECTIONFL OUT (E) 966.00NOTE: REFER TO SHEET C8.0 FORDOWNSPOUT BOOT CONNECTION DETAILMissouri Certificate of Authority#2003011262UTILITY PLAN020'SCALE: 1" 20'40'C5.0

87654EVAKCMROHCAL KAR10 - 5 galLIR VAR9 - 4"potGCER OKL1-B & BACE TRU1-B & BCER OKL1-B & BACE TRU2-B & BESCAPARYDNA25' L BOUNDPISTR1.GENERAL CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE (1) YEAR FROM DATE OFPROJECT SUBSTANTIAL COMPLETION.2.ALL PLANT MATERIALS SHALL MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FORNURSERY STOCK" (ANSI Z60.1-1990) PLUS UPDATES.3.EACH TREE AND SHRUB SHALL BE SECURELY LABELED WITH A WATERPROOF TAG INDICATING BOTANICAL NAMEAND COMMON NAME FOR DELIVERY TO SITE.4.NO PLANT MATERIAL SHALL BE SUBSTITUTED WITH OUT THE APPROVAL OF THE OWNER. ALL PLANTINGLOCATIONS FOR TREES AND SHRUBS SHALL BE FLAGGED BY THE CONTRACTOR AND APPROVED BY THE OWNER,PRIOR TO INSTALLATION.PROVIDE 2" KANSAS RIVER ROCK MULCH, 5.OR EQUAL APPROVED BY OWNER (TYP.)4" COL-MET STEEL LANDSCAPE EDGING6.THE GENERAL CONTRACTOR SHALL VERIFY LOCATION OF AND PROTECT ALL UTILITIES AND STRUCTURES.DAMAGE TO UTILITIES AND STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR.7.THE LANDSCAPE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS ON SITETHROUGHOUT THE CONSTRUCTION PROCESS.8.ALL SHRUB AND TREE PLANTING AREAS SHALL BE EXCAVATED AND BACK-FILLED WITH PLANT MIX. PROVIDEFERTILIZER WITH NOT LESS THAN 5% TOTAL NITROGEN, 10% AVAILABLE PHOSPHORIC ACID AND 5% SOLUBLEPOTASH. DISCARD SUBSOIL REMOVED FROM PLANTING AREA EXCAVATION; DO NOT MIX WITH PLANT MIX OR USEAS BACK-FILL. SEE DETAILS FOR COMPLETE PLANTING PREPARATION. PREPARE PLANTING AREAS AND INSTALLPLANTS COMPLETELY, PRIOR TO SEEDING.PROVIDE 2" KANSAS RIVER ROCK MULCH,OR EQUAL APPROVED BY OWNER (TYP.)JUN ME28 - Ht.BER AT316 - 2 galACE TRU1-B & B4" COL-MET STEEL LANDSCAPE EDGING9.PROVIDE 2" KANSAS RIVER ROCK MULCH,10. ALL SHRUBS SHALL BE INSTALLED IN PROPOSED PLANTING BEDS AND COVERED WITH RIVER ROCK MULCH OROR EQUAL APPROVED BY OWNER (TYP.)ACCEPTABLE MATERIAL APPROVED BY THE OWNER.PROVIDE 2" KANSAS RIVER ROCK MULCH,OR EQUAL APPROVED BY OWNER (TYP.)3DEU NIK9 - 2 galCER OKL1-B & B4" COL-MET STEEL LANDSCAPE EDGINGECAL KAR5 - 5 galACE AR61-B & BPROVIDE 2" KANSAS RIVER ROCK MULCH,OR EQUAL APPROVED BY OWNER (TYP.)JUN ME27 - Ht.CAL KAR10 - 5 gal4" COL-MET STEEL LANDSCAPE EDGINGBER AT39 - 2 galPROVIDE 2" KANSAS RIVER ROCK MULCH,OR EQUAL APPROVED BY OWNER (TYP.)ACE

a) Add the following specification to the project manual in its entirety: i) Basis of Design: Galaxy GS6, 19.8MM, Digital Display Unit (single face) as manufactured by Daktronics, 201 Daktronics Drive, Brookings