TEL-TRU Manufacturing Co. DIGI-TEL THERMOMETERS - M&M Control

Transcription

TEL-TRU Manufacturing Co. DIGI-TEL THERMOMETERSReplacement forLiquid-in-Glass Thermometersw w w. t e l t r u . c o m

Tel-Tru Manufacturing Company408 St. Paul St., Rochester, New York 14605 USAPhone: 585.232.1440 800.232.5335 Fax: 585.232.3857 E-mail: info@teltru.com Web: www.teltru.comDIGI-TEL THERMOMETERS GENERAL INDUSTRIAL APPLICATIONS A direct replacement alternative for Liquid-in-Glass Thermometers, BimetalThermometers, and Gas or Vapor Actuated Remote Reading ThermometersEasy to read from a distanceRugged and heavy duty High accuracyLong life batteriesSimple installation into existing thermowells RETORT APPLICATIONSMeets the requirement of FDA Rule 21 CFR Part 113.40: Equipment used for thermallyprocessed low acid foods packed in hermetically sealed containers, specifies the use ofat least one temperature indicating device per retort. Requirements include: Accurate to 1 F ( .5 C) tested and traceable to NIST Certified calibration provided with every unit Identified with a tag number Shock and vibration tested Environmental protection vs. spray Integrated display and sensor assembly Resistant to electromagnetic interference DAIRY APPLICATIONSPasteurized Milk Ordinance (PMO) requires the following specifications forindicating thermometers: Accurate to .5 F tested and traceable to NIST Sealed and tamper-proof probe and sensor assemblies Shock and vibration tested Environmental protection vs. spray Tamper-proof calibration method Self diagnostic circuit-failure detection noted on display Meets 3-A Sanitary Standard 74-06 requirements5 yearWARRANTYPage 1RTRACEABLE TONIST74-06

Tel-Tru Manufacturing Company408 St. Paul St., Rochester, New York 14605 USAPhone: 585.232.1440 800.232.5335 Fax: 585.232.3857 E-mail: info@teltru.com Web: www.teltru.comSPECIFICATIONS AND FEATURES DISPLAY ENVIRONMENTAL Ambient operating temperature range -40 F to 176 F(-20 C to 80 C) Temperature range span -75/750 F or -60/400 C Accuracy 0.5 F from 0 F to 300 F Relative humidity 90% non-condensing Accuracy below 0 F and above 300 F, add 0.0065 F perdegree Mechanical shock 100 g Resolution 0.1 F or C Vibration 5 to 60 Hz, 1G max Sample rate 3 sec. Conforms to EU/EMC directive 2004/108/EC NIST traceable factory calibration Enclosure rating IP66 High-visibility 1" tall LCD digital display Battery typeºFactory Installed 5 year LithiumºField Replaceable 2 year 3.6V 1/2 AA Lithium Error codes noted on display if problem is detected Microprocessor technology for improved stability, accuracyand PC based field calibration PROBE RTD sensor Pt1000 2-wire 316 Stainless Steel Stems 2 ½" to 24" x 0.25" diameter OTHER Weight 2 lbsSerial number on each unit for identificationWarranty 5 years from shipment:www.teltru.com/t-warranty.aspxCertificate of Calibration – traceable to NIST – standardFactory recertification and maintenance program – optionalFactory non-warranty repair service - including batteryreplacement for factory installed batteries Connection fittings:º½" NPT – standardºAvailable options: ½" NPT Union, ½" BSPT 1¼ x 18 UNEF-2A with ⅝" stem and tapered bulb Plain bushing if sliding union required Tri-Clover 3-A sanitary flanges - sizes 3 4" to 4" HOUSING 5" 304SS case with direct mounted 316SS sensor probeºBack connectedºBottom connectedºAdjustable angle 4½" case polypropylene body with Teflon covered cable andremote sensor probePage 2

DIGI-TEL INDUSTRIAL DIRECT THERMOMETERS, 5" CASETel-Tru Electronic Thermometers offer a high visibility read-out, maximum accuracy, rugged convenience,and industry-leading value for your investment. HOW TO ORDER:Create detailed part number from chart below:AN D 5 ABXC0 9CodeD1 1E1FP 2 20 2H2DescriptionACase Size and Mounting - IndustrialND5A5" Adjustable AngleND5B5" Back ConnectND5C5" Bottom Connect 6:00 ProbeND5D5" Bottom 3:00 ProbeND5E5" Bottom 9:00 ProbeND5F5" Bottom 12:00 ProbeBBattery OptionXFactory InstalledBField Replaceable BatteryCRange0958DAccuracy (at 0-300 F or -15-150 C)21 2 F ( 1.1 C)11 0.5 F ( 0.3 C)ELens13FProbe Type and DiameterP22316SS Blunt (Std), .250" DiameterP32316SS Pointed, .250" DiameterP55316SS 5/8" stem with 7/16" tapered bulbGProbe Length*HG ND5A-75/750 F-60/400 CGlass (Std)PolycarbonateAvailable for probe typesP22 and P32 aboveAvailable for probe typeP55 above only0204060912151824To fit nominal lengths ofMIG 2"Connection61/2" NPT21/2" NPT Union71/2" BSPT4Plain Bushing51-1/4" x 18 UNEF-2A Swivel Nut ND5C(only available for probe type P55 above)Optional Additional ItemsCodeDescription96003602Tagging, 316 stainless steel engraved10000004-DT Certificate of Compliance & OriginContactNon-Warranty Repair ServiceFactory96021301Calibration Recertification Service4906301Interface cable and Software Kit96017901 for field calibrationReplaceable 2 year3.6V 1/2 AA Lithium BatteryCalibration Certificate sold standard with every unit.Page 3ND5B

Tel-Tru Manufacturing Company408 St. Paul St., Rochester, New York 14605 USAPhone: 585.232.1440 800.232.5335 Fax: 585.232.3857 E-mail: info@teltru.com Web: www.teltru.comMODELS WITH FACTORY INSTALLED BATTERY: 2.660"(67.56mm) ND5A M12 .328"(33.73mm).412"(10.47mm)1/2" NPT.375" (9.53mm).625"(15.88mm)ProbeLength1/2" NPT0.250"(6.35mm)1/2" NPT.625"(15.88mm).625"(15.88mm) ProbeLength0.250"(6.35mm)0.250"(6.35mm)MODELS WITH FIELD REPLACEABLE BATTERY: 2.625"(66.68mm)M12 Connector1.625"w/Cap(41.28mm).375" (9.53mm)ProbeLengthM12 ND5BB5" Back Connect withField Replaceable BatteryND5CB-P55 5" Bottom Connect 6:00 Probe withField Replaceable Battery, 5/8"stem with 7/16" tapered bulbND5AB5" Adjustable Angle withField Replaceable BatteryPage 4

DIGI-TEL SANITARY DIRECT THERMOMETERS, 5" CASEThis heavy duty thermometer meets 3-A Standard Sanitary Standard 74-06 requirements for Sensors and Sensor Fittings and Connections Usedon Milk and Milk Products Equipment.” Other application markets include the food and beverage processing and pharmaceutical industries.No thermowell is required because a Tri-Clamp sanitary fitting is integral to the thermometer, reducing installation and instrument costs. HOW TO ORDER:Create detailed part number from chart below:AS D 5 BBXC0 9CodeD2 1E3FP 2 2G0 2H3- 1 0DescriptionACase Size and Mounting - SanitarySD5A5" Adjustable AngleSD5B5" Back ConnectSD5C5" Bottom Connect 6:00 ProbeSD5D5" Bottom 3:00 ProbeSD5E5" Bottom 9:00 ProbeSD5F5" Bottom 12:00 ProbeBBattery OptionXFactory InstalledBField Replaceable BatteryCRange0958DAccuracy (at 0-300 F or -15-150 C)21 2 F ( 1.1 C)11 0.5 F ( 0.3 C)ELens13FProbe Type and DiameterP22316SS Blunt (Std), .250" DiameterP32316SS Pointed, .250" DiameterGProbe 6.5"JQ22.5"HConnection3-053/4" Tri-Clamp (316LSS) **3-101 1/2" Tri-Clamp (316LSS) ***3-202" Tri-Clamp (316LSS)3-252 1/2" Tri-Clamp (316LSS)3-303" Tri-Clamp (316LSS)3-404" Tri-Clamp (316LSS) -75/750 F-60/400 CSD5AGlass (Std)Polycarbonate**used on both 1/2" and 3/4" lines SD5C***used on both 1" and 1 1/2" linesOptional Additional ory960213014906301Tagging, 316 stainless steel engravedCertificate of Compliance & Origin96017901Non-Warranty Repair ServiceCalibration Recertification ServiceInterface cable and Software Kitfor field calibrationReplaceable 2 year3.6V 1/2 AA Lithium Battery SD5BR*Tri-Clamp is a registered trademark of Alfa Laval Inc. Corporation74-06Calibration Certificate sold standard with every unit.Page 5

Tel-Tru Manufacturing Company408 St. Paul St., Rochester, New York 14605 USAPhone: 585.232.1440 800.232.5335 Fax: 585.232.3857 E-mail: info@teltru.com Web: www.teltru.com MODELS WITH FACTORY INSTALLED BATTERY:2.660"(67.56mm) SD5A 5.040"(128.02mm)M12 Connectorw/Cap5.040"(128.02mm)M12 250"(6.35mm)ProbeLengthM12 Connectorw/Cap1.250" (31.75mm)2.020"(51.31mm) DELS WITH FIELD REPLACEABLE BATTERY: SD5AB5" Adjustable Angle withField Replaceable M12 Connectorw/Cap1.250”[31.75mm]FlangeDiameter SD5BB B5" Bottom Connect6:00 Probe with FieldReplaceable BatteryR74-06Page 6

DIGI-TEL INDUSTRIAL REMOTE THERMOMETERS, 41 2" CASEThe Tel-Tru ND4R Industrial Remote display is protected from volatile materials, high vibration, or other environmentalconditions when mounted remotely from the sensor. AHOW TO ORDER:Create detailed part number from chart below:CodeN D 4 RCB0 9DE2 15FGP 2 20 2HI2 - C 1 0 0 5DescriptionACase Size and Mounting - IndustrialND4R4.5" Remote MountBBattery OptionBFIeld Replaceable BatteryCRange0958-75/750 F-60/400 CDAccuracy2111(at 0-300 F or -15-150 C) 2 F ( 1.1 C) 0.5 F ( 0.3 C)ELens53Glass, Shatterproof (Std)PolycarbonateFProbe Type and DiameterP22316SS Blunt (Std), .250" DiameterP32316SS Pointed, .250" DiameterP55316SS 5/8" stem with 7/16" tapered bulbGProbe LengthAvailable for probe typesP22 and P32 above0204060912151824B2.5"4"6"9"12"15"18"24" ND4RP22 ProbeAvailable for probe typeP55 above onlyTo fit nominal lengths ofMIG thermowellsBE0609123.5"6"9"12"HConnection21/2" NPT Union51-1/4" x 18 UNEF-2A Swivel NutICable Length-C10055 feet-C101010 feet-C101515 feet-C102020 feet-C102525 feet-C103030 feet-C104040 feet-C105050 feet-C107575 feet-C1100100 feet(only available for probe type P55 above) P22Cable P55Cable5/8" stem with7/16" tapered bulbBlunt (Std),.250 nal Additional ItemsCodeDescription96003602Tagging, 316 stainless steel engraved10000004-DT Certificate of Compliance & OriginContactNon-Warranty Repair ServiceFactory96021301Calibration Recertification Service4906301Interface cable and Software Kit96017901for field calibrationReplaceable 2 year3.6V 1/2 AA Lithium Battery.625"1-1/4”-18 UNEF1/2" NPTø.750”ProbeLength0.250"(6.35mm)Calibration Certificate sold standard with every unit.Page 7.625"(15.88mm).938”1-1/4” HEX(15.88mm)2.560”ø.471”TAPEREDDOWN TOø.434”1-1/4” HEX1-1/4”-18 UNEFPROBE 560”ø.471”TAPEREDDOWN TOø.434”

DIGI-TEL SANITARY REMOTE THERMOMETERS, 41 2" CASEThe Tel-Tru SD4R Sanitary Remote display is protected from volatile materials, high vibration, or other environmental conditionswhen mounted remotely from the sensor.A S D 4 RHOW TO ORDER:BBCD0 91 1E3FP 2 2G0 2HI3 - 1 0 - C 1 0 0 5Create detailed part number from chart below:CodeDescriptionACase Size and Mounting - SanitarySD4R4.5" Remote MountBBattery OptionBField Replaceable BatteryCRange0958-75/750 F-60/400 CDAccuracy2111(at 0-300 F or -15-150 C) 2 F ( 1.1 C) 0.5 F ( 0.3 C)ELens53Glass, Shatterproof (Std)PolycarbonateFProbe Type and DiameterP22316SS Blunt (Std), .250" DiameterP32316SS Pointed, .250" DiameterGProbe .5"JQ22.5"HConnection3-053/4" Tri-Clamp (316LSS) *3-101 1/2" Tri-Clamp (316LSS) **3-202" Tri-Clamp (316LSS)3-252 1/2" Tri-Clamp (316LSS)3-303" Tri-Clamp (316LSS)3-404" Tri-Clamp (316LSS)ICable Length-C10055 feet-C101010 feet-C101515 feet-C102020 feet-C102525 feet-C103030 feet-C104040 feet-C105050 feet-C107575 feet-C1100100 feet*used on both 1/2" and 3/4" linesPrice )3.095"(78.61mm)**used on both 1" and 1 1/2" linesOptional Additional ory960213014906301Tagging, 316 stainless steel engravedCertificate of Compliance & Origin96017901 CableCalibration Recertification ServiceInterface cable and Software n-Warranty Repair 1mm)2.530"(64.26mm)for field calibrationReplaceable 2 year3.6V 1/2 AA Lithium BatteryR74-06Calibration Certificate sold standard with every unit.Page 8

Tel-Tru Manufacturing Company408 St. Paul St., Rochester, New York 14605 USAPhone: 585.232.1440 800.232.5335 Fax: 585.232.3857 E-mail: info@teltru.com Web: www.teltru.com CHANGING BATTERIESReplace battery with a 3.6V ½ AA Lithium battery(Saft LS 14250 or equivalent), with negative terminal atspring end of battery holder.Full instructions available .pdfDirect Mount PROGRAMMING SOFTWARE - OPTIONAL Field calibrationUser-selectable display resolutionRemote MountFull instructions available at: fCOMPANION PRODUCTS CHECK-SET THERMOMETER CALIBRATOREnvironmental Safety and Health Professionals, Quality Assurance Managers and HACCP Coordinators in food processing/smoking, preparing/cooking, holding/serving and cooling/storage are using Check-Set Thermometer Calibrators to verify the accuracy of their dial and digital thermometers.CHECK AND CALIBRATE AT YOUR CRITICAL TEMPERATURE POINT 40 F and 160 F / 5 C and 90 C - Dual cold and hot units. Each unit serialized and certified traceable tothe National Institute for Standards and Testing. 40 F - Low temperature holding. Builtin circuitry to warn if unit is more than 1 F 140 F - High temperature holding.outofcalibration. 160 F - Temperature at which E. Coli and other Optional factory re-certification andpathogens are killed.maintenance program. 212 F - Point of boiling waterGENERAL CHECK-SET THERMOMETER CALIBRATORSPECIFICATIONS: For complete information uracy: 0.2 FStability: 0.06 F to 0.09 FHeating Time: Approximately 3 – 8 minutes (varies with temperatureset point)Stem Diameter: Varies by modelVoltage:90 to 130 VAC, 50/60 HzPower:25 – 45 WattsWeight:8.9 to 9.2 lbs.Housing Mat.: Stainless Steel 304SSSize:3-1/16" H x 6-5/8" W x 10-7/8"D (78 mm x 168 x 276 mm)Page 9

Tel-Tru Manufacturing Company408 St. Paul St., Rochester, New York 14605 USAPhone: 585.232.1440 800.232.5335 Fax: 585.232.3857 E-mail: info@teltru.com Web: www.teltru.com THERMOWELLSWe recommend thermowells for pressure, corrosive fluid,and high velocity applications.Tel-Tru thermowells are machined from solid bar stockfor standard or high velocity requirements in a largeselection of materials and coatings. They are designedand manufactured to assure perfect alignment with thesensor stem.For complete dimensions, sizes, available materials,optional features and configurations, see the Thermowellcatalog at: www.teltru.com/catalogs.aspTechnical data on pressure and temperature ratings andmaximum fluid velocity can also be found at:www.teltru.com/t-ThermowellTech.aspxSEE TEL-TRU THERMOWELL CATALOGFor complete dimensions, sizes, available materials, optional features and configurations. For technical data on pressure andtemperature ratings and maximum fluid velocity see dLimited SpaceSANITARYFLANGEDStraightHeavy Duty TaperedWELDEDVAN STONESocket WeldWeld-InPage 10

ADDITIONAL PRODUCTSAVAILABLE FROM TEL-TRUBimetal ThermometersIndustrial and Sanitary RTDsTemperature TransmittersVapor Tension ThermometersGas Actuated ThermometersThermowellsCheck-Set ThermometerCalibratorsTel-Fast Infrared ThermometersSurface ThermometersPressure TransmittersPressure GaugesSpecifications subject to change. For most current specifications, see:www.teltru.com/images/Catalogs/DT/DT.pdfDT614 REV1 2015

Tel-Tru Electronic Thermometers offer a high visibility read-out, maximum accuracy, rugged convenience, . Calibration Certificate sold standard with every unit. 2.660" (67.56mm) M12 Connector w/Cap 2.020" (51.31mm) . This heavy duty thermometer meets 3-A Standard Sanitary Standard 74-06 requirements for Sensors and Sensor Fittings and .