UNIBLOCK UBRUNIBLOCK UBRHybrid Rotary UPSfrom 150kVA-40MVANothing protects quite like Pillerwww.piller.com

2PILLER UPSmaximum power supply when compromise is not an optionAbout PillerThe Problem:Since its formation by Anton Piller in 1909, the company Pillerhas been synonymous with electrical machines of the highestquality and reliability. Today, Piller , from its headquarters inGermany and via its regional offices, representatives anddistributors world-wide, continues that tradition into the 21stcentury. Piller produces high performance power protectionsystems and converters. Combined with the highest levels ofclient support and engineering excellence available anywhere,Piller is internationally recognised as the most respected namein its field. Piller is a wholly owned subsidiary of the multidisciplined global UK engineering group, Langley Holdingsplc. (www.langleyholdings.com)The internet and telecommunication revolution has transformedthe way we do business, process data and communicateacross the globe. As we become increasingly dependent uponinformation technology, minimising system failures is absolutelycritical.Nearly every day a mains failure occurs lasting longer than 10milliseconds which seriously endangers the operation ofcomputer centres and industrial processes. Of all themalfunctions in such operations one of the major causes is aninterrupted or poor quality power supply.Informed business leaders understand the need to minimiserisk to their IT and industrial power systems and place powersupply protection at the centre of their risk managementstrategy.“Due to the increasing performance, processing speed andintegration level of electronics, the requirements placed on thequality of power supplied to IT systems are so high that thenecessary energy cannot usually be drawn directly from thepublic supply network” (VDEW: German Association ofElectricity Supply Services)Many businesses are unaware of the very real threat posed tothem by the numerous and unexpected mains electrical supplydisturbances and the resultant risk of data or production loss.Re-assembly of lost data or the re-starting of a productionprocess can be extremely time-consuming at best and at worstimpossible. For example, an analysis made in the USAforecasts the financial survival periods of major businesssectors like Banking and Insurance companies to be between2 - 5 days after the failure of their IT systems.Mains electrical supply disturbances are a major threat to business and theresulting loss of income or data is often disastrous.

3PROTECTING:Information SystemsBroadcasting & TelecommunicationsIndustrial ProcessesMedical & ScientificThe Solution:A Piller Uninterruptible Power System (UPS) provides theessential cover, and peace of mind, that ensures mainsdisturbances don’t have a major impact on your business.Piller is the pre-eminent manufacturer of large scale UPS andmany thousands of Piller UPS are currently installed globally,providing major industries with the power protection theyneed.Piller has many years experience operating internationally inproviding high-performance power systems, and PillerUNIBLOCK UBR technology is based on this know-how. Ourunique concept is the combination of high performancemotor generator construction with straightforward powerelectronics, controlled and managed by the latest processortechnology.The IT load is changing rapidly and todays UPS technologymust have the capability to meet the needs of tomorrow. Forexample, in just a few years the design of UPS powerrequirements for data centres has grown to such an extentthat there are serious implications for other UPS designs inuse, but these additional demands are easily met by theunique Piller rotary technology!This topological approach to UPS design has beenrepeatedly proven to be the best choice when compromise isnot an option.The Uptime Institute sets out the requirements for the designof data centres to various standards. As you move up thesestandards fewer and fewer solutions are capable ofsupporting these levels. At the highest standard required bydata centres, entire redundant UPS systems must support asingle load and this creates new technical challenges notreadily met by mass produced UPS solutions.Governed by various levels of infrastructure that mustsurround computing technology the Uptime Institute statesthat there is a requirement for the best data centres to beprotected at the industry standard tier level 4.A Piller UNIBLOCK UBR has the versatility and capability tomeet these demands through characteristics such as: Full galvanic isolation for independently earthedsystemsInternal redundancy for optimum reliabilityUnique dual diversified input capabilityVoltage and frequency control for synchronisedsystemsAdaptability for changes in load demands such asleading power factorShort circuit capability“Informed business leaders placepower supply protection at the centreof their risk management strategy”

4Innovation for your benefit.Few components - many functionsThe Piller UNIBLOCK machine combines a motor and agenerator in one, three-phase synchronous unit. Duringconstruction, the windings of both components areincorporated in a shared stator and are excited by a commonrotor. The energy transfer from the motor to the generatortakes place via direct magnetic coupling without loss andwithout electro-mechanical conversion, thus providingelectrical (galvanic) isolation between the mains supply andthe load.The advantages of this form of construction, which has a highload-carrying capacity are:- it is robust, highly efficient, canbe loaded continuously and overloaded simultaneously,which is not possible with power electronics alone as foundin a static UPS.The UNIBLOCK machine prevents load disturbancesreaching the mains. It has a damper cage which absorbscurrent harmonics, irrespective of load current and loadpower factor. Unbalanced loads are also equalised.By combining the UNIBLOCK machine with the topology ofthe UBR configuration, a truly unique concept has beenachieved: a natural sine wave whilst utilising the flexibility ofpower electronics but still maintaining an extremely highdegree of reliability.

5“UNIBLOCK UBR .a truly unique concept”Why the PILLER UNIBLOCK UBR system is superior to other UPS systemsFeatureBenefitVery high reliability.Higher availability and reduced risk to your critical loads.High inherent fault clearing capacity.Rapid disconnection of faulty loads is possible even in battery operation.No by-pass supply needs to be present, which is necessary for staticsystems, which reduces the risk of outages to your critical load.Higher efficiency.Reduces operating costs and minimises the total cost of ownership of yourUPS system.No power capacitors or electric fans.Reducing your maintenance costs and more importantly removing the risk ofunplanned failure of these components.Full galvanic isolation.Independent earthing systems are easily implemented avoiding circulatingcurrents and erratic discrimination without the need for additional isolationtransformers – this reduces your system complexity, improves efficiency, andgives you cost and space savings.Near unity input power factor.Power factor protection is not required saving you capital and maintenancecosts.No crest factor limit.Capable of delivering high peak currents for harmonic loads.Water-cooled option.Direct coupled cooling eliminates your need for air-conditioning, saving youspace, cost, and removes the need for additional maintenance overheads.Full voltage and frequency control.UBR is the only UPS to offer rotary characteristics combined with doubleconversion allowing you to synchronise for your Tier 3 and Tier 4requirements.Redundant power conditioning paths.The UPS can be fed from different sources via separate power conditioningpaths which can dramatically increase your scheme reliability.Natural sine wave generation.The UPS output is a pure, natural sine wave that gives you a future-proofedUPS for your ever changing IT loadsA damper cage for filtering harmonics.No additional harmonic filtering required; improves efficiency, saves youspace and cost.Capable of active change in redundancystatus.Optimising your UPS system based on the actual loads, giving higher levelsof efficiency and reducing risk to your load.Extremely low AC battery ripple.Lower AC ripple (compared with static) extends the service life of yourbattery.Low internal sub-transient reactance.Clean voltage sine wave reducing voltage distortion for high harmonic loads,reduces your need for harmonic filters saving you money.

6Your requirements determine the solutionFault Clearing CapabilityUNIBLOCK UBR with dual inputThe UNIBLOCK by virtue of its low output impedanceinherently delivers fault current of 14 times the nominal fullload. Offering fault current delivery similar to the systemsutility transformer, security is provided even when utility poweris not available to the site. This guarantees disconnection ofa downstream fault within 10 milliseconds, without going to anunprotected bypass source, if available, as required by otherUPS systems! With UNIBLOCK during fault clearing, full UPSfunction – including battery operation – is maintained andremaining loads are unaffected. The UNIBLOCK UBR assuresthat a localised fault won’t take out the entire data centre.This inherent ability to clear faults is a critical attribute in N Nsystem architecture where the load needs to be supplied bysynchronous supplies from the independent UPS systems.Both independent UPS systems can be synchronised to eachother and maintain full short circuit clearing ability under allIf failure of mains 1:Both A and B supplies to the load remain UPS backed.operating modes. Other UPS systems are unable to providea total fault clearing capability in order to remainsynchronised.The unique configuration flexibility of the UNIBLOCK UBR means that a number of distinct system advantages can beutilised to facilitate the need to be concurrently maintainable and truly redundant. These advantages are not all availableon other technologies:UNIBLOCKUBRExampleDiesel UPSExampleStatic UPSNumber of full load power paths (including bypass) 1433Number of conditioning power paths 1322444444444488884888888External system to system synchronisation2Short circuit fault discrimination without UtilityFull UPS function without bypassExternal synchronisation capability with full UPS function 2Isolated 4 pole N-E system capability (for S S solutions) 3Full galvanic isolation 3Dual input capability for power conditioning paths 41234The UNIBLOCK UBR is unique in providing power conditioning and isolation on three paths.Static and Diesel UPS lose some functionality.Without additional isolation transformers in Static and Diesel UPS, circulating currents can arise.Input distribution failure does not force the use of emergency back-up mode and provides concurrent maintenance upstream.

7“.UNIBLOCK UBR assures a localised fault won’t take out the entire data centre”UNIBLOCK UBR with built-in Water CoolingUNIBLOCK UBR in Containerised UnitsExpensive air-conditioning or ventilation measures areunnecessary where chilled water is readily available.As an alternative to the stationary version, the UNIBLOCKsystem is also available as a high-performance andeconomical container unit. All components necessary foroperation are integrated into the container. The system isimmediately ready for operation after it has been coupled tothe AC supply system. This variant eliminates planning costsand the costs of integrating the system into the buildingstructure.The integrated cooling unit provides the UPS system with itsown climate. The UPS can even be operated in small rooms,in aggressive environments or one containing dust oraerosols. Each water-cooled Piller UNIBLOCK UBR module isequipped with its own correctly rated cooler. This means thatno air-conditioning unit is required.Advantages: Higher efficiency of your systemInsensitive to the amount of pollution in thesurrounding airLower investment costsLower operating costsOne supplier, one service partnerSmaller space requirementReduced noise pollutionCross section of water-cooled unitA: The enclosed air circuit is operated by an internalfan impeller incorporated in the rotor of the electricalmachine.B: The UNIBLOCK UBR with built in water cooling isconnected to the chilled water circuit of the building.

8PILLER UNIBLOCK UBRuser-friendly touch controlOperator ControlTouch Panel FeaturesThe state-of-the-art touch control panel is designed foroptimum man/machine communication. The clear layout andintuitively accessible control panel has been made fully userfriendly. A built-in mimic display with clear symbols allows alloperating states to be seen at a glance. Detailed information on the condition of the individualmodules is immediately available. Additionally, interactivecommunication with built-in safety routines preventsunintentional switching operations. The optional remotecontrol version enables remote monitoring and management,for example at a central command centre, with simultaneousaccess to individual systems. High resolution colour displayVisualisation system for rapid capture of parameterssuch as current, voltage, frequency and phaseMulti-lingual menu for use in specific countriesMenu-driven operator prompts for fast accessField-proven, in-depth information for precise systemmonitoring.Diagnostic system with built-in event monitor, storingthe last 1200 eventsBattery monitor for battery parameters such ascurrent, voltage and temperature

9The UNIBLOCK UBR module has a full range of connectionand interface options to allow the UPS to be integrated withinthe BMS/EMS systems of the building to ensure compatibilityand simplicity of installation.Remote Diagnostics ServiceTo offer you the highest level of service and support possibleUNIBLOCK has the potential for two-way communicationbetween the UPS module and our National Service Centres.Through this link, Piller can offer an enhanced support serviceto clients and provide both Remote Diagnostic and RemoteService Support solutions through dedicated RemoteDiagnostics Service (RDS).Remote AccessThe system can be configured with two different levels ofaccess; these levels are set-up as part of the commissioningprocess and are then password protected within the UPSSystem menu. With the different levels of access, there aredifferent levels of control:The first allows for the events and status to be ‘read only’.This means that the Engineer can only request informationand view the Event Log, No changes can be made to thesystem.A higher second level allows for the events and status to beread and then allows the Engineer to remotely take full controlof, and change the operational state of the UPS module.“.state-of-the-art touch control panel is designedfor optimum man/machine communication”

10PILLER UNIBLOCK UBR - unprecedented serviceUnrivalled After Sales ServiceCompetence and responsiveness are the watchwords of ourbusiness.Piller believe that product and service belong together, and thePiller name is synonymous with excellent after sales service.The best technology is only as good in the long term as theservice that underpins it.For this purpose, a comprehensive network of qualifiedservice staff is available – world-wide.The premium quality and technical maturity of every Pillerproduct already guarantees a high degree of functionalsecurity, and together with quality maintenance, this furtherreduces any risk of possible breakdown.Piller offers a comprehensive package of services tailored toyour requirements: Technical consultationOperator trainingFunctional testingMaintenanceFault analysis and troubleshootingCustomer trainingRemote system diagnosis and supportService Team CapabilityPiller’s customer service engineering team is highly qualifiedand trained on all products and services. As a combined total,field service teams have centuries of experience working onthree generations of UPS system. Piller operates a ‘best ofbreed’ philosophy in all working practices and is believed tobe market leaders in first time resolution of site problems.

11“.on demand 24 hours a day, 365 days a year”Piller ServicePiller understands that malfunctions can also occur outsideworking hours, which is when competent help is neededquickly. For this reason an emergency call-out service is inoperation.Service centres are strategically positioned in relation toPiller’s installed base for the best possible response time andfamiliarity with clients’ installations.

Nothing protects quite like PillerPiller Group GmbHAbgunst 2437520 Osterode,GermanyT 49 (0) 5522 311 0F 49 (0) 5522 311 414E info@piller.comROTARY UPS SYSTEMSSTATIC UPS SYSTEMSPiller Australia Pty. Ltd.2/3 Salisbury RoadCastle Hill, NSW 2154AustraliaPiller Iberica S.L.UPaseo de la Habana, 202 Bis BjE-28036 MadridSpainT 61 2 9894 1888F 61 2 9894 2333E australiamail@piller.comT 34 91 345 86 58F 34 91 350 16 33E ibericamail@piller.comPiller France SAS107-111 Av, Georges ClémenceauB.P. 908, F-92009 Nanterre CedexFrancePiller Power Singapore Pte. Ltd.25 International Business Park#04-13/14 German CentreSingapore 609916T 33 (0) 1 47 21 22 55F 33 (0) 1 47 24 05 15E francemail@piller.comT 65 6562 9100F 65 6562 9109E singaporemail@piller.comPiller Germany GmbH & Co. KGAbgunst 2437520 Osterode,GermanyPiller UK Limited91 Chesterton Lane, CirencesterGloucestershire GL7 1YEEngland, UKT 49 (0) 5522 311 0F 49 (0) 5522 311 414E germanymail@piller.comT 44 (0)1285 657 721F 44 (0)1285 654 823E ukmail@piller.comPiller Italia S.r.l.Piazza Pertini n. 19I-20067 Paullo, MilanItalyPiller USA Inc.45 Turner Drive, MiddletownNew York 10941-2047USAT 39 02 9063 3780F 39 02 9063 3788E italiamail@piller.comT 1 800 597 6937F 1 845 692 0295E usmail@piller.comSTATIC TRANSFER SWITCHESKINETIC ENERGY STORAGEAIRCRAFT GROUND POWER SYSTEMSRepresentatives and Distributors in:ARGENTINA . AUSTRIA . BELGIUM . BRAZIL . CANADA . CHILE . CHINA . DENMARKE S T O N I A . F I N L A N D . H O N G K O N G . H U N G A R Y . I N D I A . I N D O N E S I A . I R A N . J A PA NFREQUENCY CONVERTERSKOREA.LATVIA.M A L AY S I A.NETHERLANDS.N O R WAYNAVAL POWER SUPPLIESPOLANDSYSTEM INTEGRATIONSYRIA . TAIWAN . THAILAND . TURKEY . U.A .E . . UKRAINE . USAwww.piller.com.RUSSIA.SERBIA.SOUTHThe information contained within this brochure is deemed to be correct at the time ofgoing to press. Due to a policy of continued improvement, we reserve the right tochange any specification without prior notice.ERRORS & OMISSIONS EXCEPTEDIssue 2 2008.07AFRICA.SWEDEN.PHILIPPINESSWITZERLAND

A Piller Uninterruptible Power System (UPS) provides the essential cover, and peace of mind, that ensures mains disturbances don't have a major impact on your business. Piller is the pre-eminent manufacturer of large scale UPS and many thousands of Piller UPS are currently installed globally, providing major industries with the power .