Power And Energy Meters PM2000 Multi-function Meters Functions And .

Transcription

CÔNG TY CỔ PHẦN THIẾT BỊ ĐIỆN HOÀNG PHƯƠNGĐC: Số 10, ngõ 44, phố Võ Thị Sáu, P.Thanh Nhàn, Q.Hai Bà Trưng, TP. Hà NộiPower and energy metersMST: 0106798886Tel: 024.3215.1322Website: Hoangphuong.com.vnPhone: 0944.240.317 / 0975.123.698 / 0961.008.858Email: Codienhoangphuong@gmail.comPM2000 multi-function meters Functions and characteristicsPB114325Functions and characteristicsIntroducing EasyLogic PM2000 series, next generation power meter which offers allthe measurement capabilities required to monitor an electrical installation in a single96 x 96 mm unit. PM2000 meters are available in LED and LCD display variants.bb PM2100 series: LED display type: Intuitive navigation with self-guided, threebuttons, bright red colour LEDs of 14.2 mm height. Two columns of LEDs, one oneach side of the meter’s front panel indicates the parameter name chosen for displaybb PM2200 series: LCD display type: Monochrome graphical LCD of 128 x 128resolution with viewable area of 67 x 62.5 mm lets the users read all three phasemeasured values simultaneously. The bright anti-glare display features largecharacters and powerful backlighting for easy reading even in extreme lightingconditions and viewing angles. Intuitive menus, multi-language text, icons andgraphics create a friendly environment to learn about your electrical network.ApplicationsCost management:bb Electrical installation remote monitoringbb Energy accounting and balancingbb Tenant and sub-billingbb Panel instrumentationbb Energy managementPB115531PM2000 series LED display meterNetwork management:bb Power quality analysis: THD and individual harmonics up to 15th and 31st orderbb Measurement of True PF and Displacement PFbb Recording Min/Max values of instantaneous parameters with date & timestampbb Optional IO modules comprising either 2 Digital Inputs and 2 Outputs, or 2Analogue Inputs and 2 Outputs for comprehensive WAGES monitoringbb Calculates % unbalance for voltage & currentPM2000 LCD displayCommercial reference numbersRef. EPM2230PM2230METSEPM2KDGTLIO22 PM2K2DIDOMETSEPM2KANLGIO22 PM2K2AIAOMETSEPM2KANLGIO11 PM2K1AIAOSee your Schneider Electric representative forcomplete ordering information.PLSED310090ENMain characteristics:bb Easy to install: Mounts using two clips, no tools are required. Compact meter with54 mm depth, connectable up to 480 /-10% AC Volts L-L without voltage transformersfor installations compliant with measurement category III, and double insulated.bb Easy to operate: Intuitive navigation with self guided menus and test LED at thefront panel used for test and calibration of the meter on site or laboratory. Heart-beatLED indicates normal functioning and communication status if connected to RS-485network.bb Product standard compliancevv Active energy Class 1.0 as per IEC 62053-21vv Active energy Class 0.5S as per IEC 62053-22 (partial compliance for activeenergy test clause only)vv Reactive energy Class 1.0 as per IEC 62053-24 (partial compliance for reactiveenergy test clause only)bb Tested in accordance with IEC 62052-11 standard forvv 5 A, I-nominalvv 1 A, I-nominal (field settable).bb Power quality analysis: The PM2000 offers THD measurements and Individualharmonics up to15th order in PM2x20 variants and up to 31st in PM2x30 variants.bb Load management: Simultaneous display of peak, present, predicted & risingdemands of all the four demand parameters (W, VA, VAR, Amps)bb Billing: Tenant billing/utility meter cross check (where local regulations are notapplicable).bb Timer: Active load timer, Meter operation timer and Run hours timer. These featureshelp advise maintenance requirements and scheduling.bb Password: Field configurable password for securing set up information and preventtampering of integrated values.bb Cyber security: Option for disabling RS-485 port through front panel keys againstunauthorized access. It helps during installation and trouble shooting ofcommunication network.bb LED display: Auto scaling, 9 3 digits for energy, 4 digits for other parameters.bb LCD display: 5 digits for energy, 5 or 6 digits for other parameters, with auto scaling.bb 12am snap shot: The values from summary page will be stored as snap shot andrefreshed by next day 12am.bb Rate counters: 2 configurable counters display values in custom specified unitsbased on energy recorded (e.g., kgCO2 carbon emission or energy cost).bb Energy preset feature: For retrofit application.1

PM2000 multi-function meters Power and energy metersFunctions and characteristicsGeneralPB114317Use on LV and MV systems with onsite programmable PT/CT ratioBasic metering with THD, Individual Harmonics, RTC and min/max readingsInstantaneous rms valuesCurrentVoltageFrequencyReal, reactive, and apparent powerDisplacement power factorTrue Power Factor% UnbalanceAverage line current of 3-phase, per-phase, and calculatedneutral currentAverage voltage of L-L, L-N parameters, and per-phaseAny available lineTotal and per-phase valueAverage and per-phase signed, four quadrantAverage and per-phase signed, four quadrantAmong the phase for Amps, V L-N, V L-LEnergy values stored in non-volatile memoryRear of PM2000 closedOld RegistersAccumulated energy values for Active, Reactive & ApparentEnergy parameters, quadrant basisNet & Total (absolute) valuesAccumulated time counters for active load timer, meteroperation timer, run hours and power outage counterFacilitates retrieval of last cleared energy valuesCurrent averageActive powerReactive powerApparent powerDemand sync methodsDemand calculation modeDemand intervalsPresent, Last, Predicted, Peak, and Peak Date TimePresent, Last, Predicted, Peak, and Peak Date TimePresent, Last, Predicted, Peak, and Peak Date TimePresent, Last, Predicted, Peak, and Peak Date TimeThermal, Timed, Command Sync, and Clocked SyncSliding, fixed and rolling blockSettable from 1 to 60 minutes, in the step of 1 minuteFour quadrant measurement forDelivered (Forward or Import) andReceived (Reverse or Export) energyTimerPB114318Demand valuesDisplayPM2100 seriesPM2200 seriesVisualization mode for signsBright red colour LED display, 7 segment LED, 14.2 mm height,3 rows with 4 digits per row, Auto rangeFull scape, monochrome graphical LCD of 128 x 128 resolutionwith viewable area of 67 x 62.5 mmIEC or IEEE type in LCD display meterCommunicationRear of PM2000 openRS-485 serialChannel connection Industry standard Modbus RTU protocolIntegration with softwareSCADA/ DCS/ PMS/ EMS/ BAS/ BMS softwareNative Plug and Play supportSchneider Electric energy management system software StruxureWare Power Monitoring Expert, StruxureWarePowerSCADA Expert along with ION Setup programmingsupportPB114321Min/Max valuesMinimum & Maximum value recording of For 8 parameters, viz., V L-L, V L-N, Amps, PF, Hz, W, VA,3-ph average or totalVAR with date and time stamp, resettable separately throughset up modeAlarmsAlarming with time stamping in PM2x30 A different combination of set point driven alarms and digitalmetersalarms with 1s time stamping. The alarms can beprogrammed and combined to trigger digital outputs, themeter keeps an alarm logs with the active and historicalalarms with date and time stamping in 40 registersDiagnosticsDiagnostic pageLock/ Un-LockPage Lock & Unlock (PM2100 series)Rear of PM2000 without I/O moduleRate 1 counter 1kgCO2 emission (example)Indicates LED/LCD status, sl number, diag pages, OS & RSversionUnique feature to ensures that commonly referred page isrestored in 4 minutes of inactive timeRate counter can be configured to display the CO2 emission inkgCO2 format based on the kWh measured either in deliveredor received direction.Rate 2 counter 1Tariff counter (example)12am snap shot12am snap shot 1 12Rate counter can also be configured to calculate the electricitycost based on the energy consumption in customizedcurrency format.Snap shot of Avg Voltage, Avg Current, Total Active Power &Energy delivered as measured by the meter at 12am. The staticpage will be refreshed with new values by 12am next dayIn PM2200 (LCD) series metersPLSED310090EN

PM2000 multi-function meters Power and energy metersFunctions and characteristicsElectrical characteristicsPB114320Type of measurementTrue RMS 64 samples per cycleMeasurement accuracyPB114319Rear of PM2000 with I/O moduleCurrent, average & per-phase /-0.5%Voltage average & per-phase /-0.5%Frequency /-0.05%Power Factor, average & per-phase /- 0.01Power (W-Active, VA- Apparent) /- 0.5%Power (VAR- Reactive) /- 1.0%Real/ Active Energy (Wh)Class 0.5S as per IEC 62053-22 and Class 1.0 as per IEC62053-21 for both CT nominal of 5 A and 1 A 2Reactive EnergyClass 1.0 as per IEC 62053-24Apparent Energy /-0.5%THD% andIndividual Harmonics- V & A /- 5% FS for THD & Individual harmonicsInput-voltageVT primary999 kV L-L max, secondary voltage depends on VT ratioU nominal277 V L-N/480V L-LMeasured V with full range20-277 V L-N/35 - 480 V L-L, cat III20-347 V L-N/35 - 600 V L-L, cat IIPermanent overload750 V AC L-LImpedance 5 MΩFrequency nominal50/60 HzVA burden 0.2 VA at 240 V AC L-NInput-currentRear of PM2000 with I/O module disconnectedCT ratingsPrimary adjustable 1 A to 32768 ASecondary 1 A or 5 A I-nominalMeasured Amps with overrange & Crest Factor5 mA to 6 AOver current withstandContinuous 12 A, 10s/hr 50 A, 1s/hr 500 AImpedance 0.3 mΩFrequency nominal50/60 HzVA Burden 0.1 VA at 6 AAC control powerOperating range44- 277 V AC 10% (80-277 V AC 10% with I/O card)Burden 8 VA/3.3W at 240V AC L-NFrequency45 to 65 HzRide-through time100 ms typical at 230 V AC and maximum burden100 ms typical at 277 V AC and maximum burdenDC control powerOperating range44-277 V DC 10% (100-277 V AC 10% with I/O card)Burden 2 W at 240 V DCRide-through time50 ms typical at 125 V DC and maximum burdenReal time clockRTC with battery backup3 years (when meter is in Power OFF condition)Displays updateInstantaneous1sDemand15sHarmonics5sWiring configurationUser programmable1ph, 2w, L-N1ph, 2w, L-L1ph, 3w, L-L with N (2phase)3ph, 3w, Delta, Ungrounded3ph, 3w, Delta, Corner Grounded 33ph, 3w, Wye, Ungrounded 33ph, 3w, Wye Grounded 33ph, 3w, Wye, Resistance Grounded 33ph, 4w, Open Delta, Center-Tapped 33ph, 4w, Delta, Center-Tapped 33ph, 4w, Wye, Ungrounded 33ph, 4w, Wye Grounded3ph, 4w, Wye, Resistance Grounded 3In PM2200 (LCD) series metersFor 1 A CT nominal, additional error of 1% from 50 mA to 150 mA, 2% for current 10 mA to 50mA. Partial standard compliance for Class 0.5S meter type (energy test clause only) 3Through communication in PM2100 series meters 1 2PLSED310090EN3

PM2000 multi-function meters Power and energy metersFunctions and characteristicsFunctions and characteristicsMechanical characteristicsWeight 300 gmIP degree of protectionIP54 front side, IP30 meter body as per IEC 60529MaterialPolycarbonate meets UL 94V-0 flammability ratingDimensions W x H x D96 x 96 x 54 mm maximum (depth of the meter from housingmounting flange) and 13 mm (protrusion of meter from housingflange). Meter depth with IO module is 74 mmMounting positionVerticalPanel thickness5 mm maximumEnvironmental characteristicsOperating temperatureMeter -10 to 60 CStorage temperatureMeter -25 to 70 CHumidity rating5 to 95% RH at 50 C (non-condensing)Pollution degree2Altitude2000 m Category IIIProduct lifeMinimum 7 yearsElectromagnetic compatibility 4Electrostatic dischargeIEC 61000-4-2Immunity to radiated fieldIEC 61000-4-3Immunity to fast transientsIEC 61000-4-4Immunity to impulse wavesIEC 61000-4-5Conducted immunityIEC 61000-4-6Immunity to magnetic fieldsIEC 61000-4-8Immunity to voltage dipsIEC 61000-4-11EmissionsEmissions FCC Part 15 Class A/CESafetyEuropeCE, as per IEC 61010-1 Ed-3US and CanadacULus as per UL61010-1 and CAN/CSA-C22.2 No. 61010-1,for 600V ACMeasurement category (Voltageand Current inputs)CAT III up to 480 V L-LCAT II up to 600 V L-LOvervoltage Category (Controlpower)CAT III up to 300 V L-NDielectricAs per IEC/UL 61010-1 Ed-3Protective ClassII, Double insulated for user accessible partsGreen premiumEOL, REACH, PEP, RoHS compliedOther certificationRCM (Australia), EAC (Russia)CommunicationRS-485 portModbus RTU: 2-Wires, with ground & shield, 4800, 9600, 19200 or38400 baud, Parity - Even, Odd, None, 1 stop bit if parity is Odd orEven, 2 stop bits if NoneDLF3000: Firmware update through communication portPulse Output – POPIsolationMax 40 V DC, 20 mA20 ms ON timeConfigurable pulse weight from 1 to 9999000 pulses/k h(kWh, kVAh, or kVARh)2.5 kV RMS, double insulatedProtection featuresPassword protected for set-up & clearing energy and Min/Max dataDisplay languageEnglish, Spanish, French, Chinese, German, Portugese, RussianTechnical publicationPrinted installation guide (IG) with the meter in multi language(EN,ES,FR,DE,PT, RU,TR,ZH)Human machine interfaceDisplay typeLED display: 7 segment LED, 14.2 mm height, 3 rows with 4 digitsper row 2 columns of LEDs, one on each side of the LED panel toindicate the parameters under measurementLCD display: Monochrome graphical LCD of 128x128 mm resolutionwith viewable area of 67 x 62.5 mmKeypadPM2100 series: 3 buttons for navigation & combination of 2 buttonsfor performing set-up, Lock/unlocking of page, Diagnostic pageoperationPM2200 series: 4 buttons for intuitive navigation of HMI/ UI pagesRed colour, meter constant is configurable from1 to 9999000 pulses/k h (kWh, kVAh, or kVARh)CAL LED IndicatorComm. activity 44Green LED (for indicating RS-485 interface or heart beat pulse)as per IEC 61326-1 standard (Class A Emission)PLSED310090EN

PM2000 multi-function meters Power and energy metersFunctions and characteristicsElectrical characteristics of IO modulesPB115529Status Inputs (Digital Inputs)DIDOISORear of PM2200 with I/O moduleVoltage ratings18.5 to 36 V DC, OFF 0 to 4 V DCInput resistanceMax Frequency110 kW2 Hz (T ON min T OFF min 250 ms)Detect Time20 msUpdate time1sIsolation2.5 kV RMSApplicationIntegration of Breaker status or other non-electrical devices like steam,water, gas meter through pulse inputsDisplay supportAvailable on PM2230 (LCD type). In PM2130 meter, data is availablethrough communication only.Set up and configurationDigital OutputsThrough set-up softwareVoltage ratings40 V DC max, 20mA maxOn ResistanceMeter constant50 W maxConfigurable from 1 to 9999000 k h (kWh, kVARh, kVAh)Pulse widthPulse frequency20 ms25 HzLeakage current1 micro AmpsIsolation2.5 kV RMSAlarm conditions14 set point driven alarms, 4 Unary alarms, 2 Digital inputs statusApplicationPulse output: configurable for energiesupper / lower limit: configurable for 9 parameters with 14 set point: VL-L, V L-N, Amps, F, V-THD, W-tot, VA-tot, VAR-tot, PF-avgDisplay supportAvailable on PM2230 (LCD type). In PM2130 meter, data is availablethrough communication onlyThrough set-up softwareSet up and ConfigurationAnalogue inputsMeasurement scalePB115540Digital I/O module4-20 mAInput impedance 300 WMax source impedanceUpdate rate 500 W1sAccuracy1% of Full scale at ambient temp 0.1%/K for de-ratingVoltage ratingsTypical 12 V (max 30 V)Power Consumption 1.5 WattsIsolation2.5 kV RMSApplicationConfigurable for inputs from flow rates, RPM, fluid level, oil pressure,temperature measurement devices or transducers with option of 81different Uni code selection. Configuration via set up softwareDisplayAvailable on PM2230 (LCD type). In PM2130 meter, data is availablethrough communication onlyThrough set up softwareSet up and configurationAnalogue outputsAnalogue I/O moduleScale4-20 mALoad impedanceUpdate rate 600 W1sAccuracy1% of Full scale at ambient tempVoltage ratingsTypical 12 V (max 30 V)Power Consumption 1.5 WattsIsolation2.5 kV RMSApplicationAnalogue outputs can be associated to 40 different instantaneousparametersDisplayAvailable on PM2230 (LCD type). In PM2130 meter, data is availablethrough communication onlySet-up & configurationThrough set-up softwareMechanical characteristicsMechanical dimension90.5 mm W x 53 mm H x 14.67 mm D (without connector)Weight50 g* as per IEC 61326-1PLSED310090EN5

Power and energy metersPM2000 multi-function meters Functions and characteristicsFeature set summaryAccuracy Class for WhPM2110PM2120PM21301.0Accuracy Class for VARhPM22100.5SAccuracy for VAhbbTrue PFTrue PFDisplacement PF 3Frequency, any available phaseEnergy: Wh, VAh, VARh (4 quadrant)Delivered (Import or Forward), Received (Export or Reverse)Currentbb(no (no timestamp)Delivered,Received,Total, NetDelivered, ReceivedTotal 3, Net 3, Last cleared 3Delivered, ReceivedTotal, Net, Last cleared 3Through combTHD: Voltage L-N or L-L, Amps per phaseAlarms: 14 set point driven alarms from 9 parameters (V L-L, VL-N, Amps, F, V-THD, W-tot, VA-tot, VAR-tot, PF-avg), 4 Unaryalarms (meter power up, meter reset, meter diagnostic, phasereversal) and 2 digital inputs status (with DI/DO card only)12 am snap shot of Avg Voltage, Avg Current, Total active power& Energy delivered as measured every day at 12amRate counters: 2 configurable counters to display values incustomer specified units base on energy measured (e.g., kgCO2emission or energy cost)True PFDisplacement PFbCurrentVoltage 3bActive load timer, meter operating timer, run hours and poweroutage counterIndividual harmonics for Voltage, Current, per-phaseMin/ Max with real time clock For avg or total of V L-L, V L-N,Amps, PF, Hz, W, VA, VAR parameters with date and time stampof occurrenceRTC/battery 6CommunicationExpandable Analogue IO modules (2 inputs & 2 outputs) 5Expandable Digital IO modules (2 inputs & 2 outputs) 5Customizable data logging up to 2 parameters. Option to selectPower (W,VA,VAR) Bi-directional energy ( /-Wh, /- VAh, /VARh), Demand (W, VA,VAR) with configurable intervaland duration (e.g. 2 parameters for 60 days at 15 minutesinterval)True PFbPower: W, VA, VAR: per-http://69.195.124.174/ pilatfa7/temp/Demand parameters (Present, Last, Predicted and Peak for W,VA, VAR, Amps)Date and Time stamp for peak demand0.5S /- 0.5%Voltage, V L-N, V L-L, per-phase and average3-phase unbalance %PM22301.0Amps, per-phase, average and calculated neutral currentPower FactorPM22201.0bUp to 15th 3 Up to 31st 3Through comNAPulse OutputbbRS-485Up to 15thNAPulse OutputUp to 31stbbbRS-485bbbbbbbbbbThrough communication onlyAny one IO module can be used at a time with PM2130 or PM2230 meter. The control power range with IO module shall be 72 to 304 V AC L-Nor 90 to 304 V DC. 6Battery backup duration 3 years when meter is in Power OFF condition. 3 56PLSED310090EN

Power and energy metersPM2000 multi-function meters Functions and characteristicsPB115535PM2000 LCD display legend descriptionAMenu selection buttonsBLED indicatorsCNavigation or menu selections:Exit screen and go up one levelMove cursor up list of optionsMove cursor down, display more optionsMove cursor one character to the leftScroll right and display more menu items Show next item in list or increase the highlighted valuePB115536Show previous item in listDMaintenance & alarm notification areaEControl powerFVoltage inputsGCurrent inputsH RS-485 / POPIGasketJI/O slot (for PM2x30 only )APhase measurements (VL-N, VL-L, I, kVA, kW, kVAR, PF, VTHD%, ITHD%)BDemand measurements (DM, PrsDM, Prd, DM, MD)CRTC Date & timeDNegative indicatorENavigation key to navigate downFEnergy readings Apparent enegry, Active energy, Reactive energyGNavigation key to navigate upHOK Enter keyPB115538PB115537PM2000 LED display legend descriptionIEnergy pulsing LED (red) Heartbeat / communications LED (green)Jx 1000 indicatorKSystem measurements Vavg, kVA, F, lavg, kW, In, PFavg, kVAR, lunbLControl power L1, L2MInput voltage terminals V1, V2, V3, VNN Input current terminals I1 , I1-, I2 , I2-, I3 , I3-PLSED310090ENORS-485 communications / POP terminalsPGasketQI/O card slot (for PM2130 only)7

PM2000 multi-function meters Power and energy metersDimensions and connectionLED meter installationPB114323PM2000 meter rear viewPB114324PM2000 multi-function meter mechanical dimensionsPB115539PM2000 I/O module mechanical dimensions

StruxureWare Power Monitoring Expert, StruxureWare PowerSCADA Expert along with ION Setup programming support. Min/Max values. Minimum & Maximum value recording of 3-ph average or total For 8 parameters, viz., V L-L, V L-N, Amps, PF, Hz, W, VA, VAR with date and time stamp, resettable separately through set up mode. Alarms