EPS 7000300/400/500 kVAHigh availability,high performanceschneider-electric.com

300 – 500 kVA robust three-phase powerprotection with adaptability to meet the uniquerequirements of medium to large data centers,buildings, and critical industrial processes2 schneider-electric.com Flexible and very adaptable Strong electrical features Intuitive monitoring Parallel capabilities Synchronization to external source High-availability architecture components

Features and benefitsHigh availability, high performanceThe EPS 7000 is the facility manager’s top uninterruptiblepower supply (UPS) choice with full front access and allcritical serviceable components reachable within minutes,not hours. These UPS modules allow IT and facilitiesmanagers to respond to increasing demands placed onpower infrastructure in growing facilities by offering N 1capabilities. The EPS 7000 was the first in the industry toincorporate a 100-percent-rated static switch on outputof UPS inverter with no mechanical contactors, which canage and weaken during UPS operation. Energy efficiencyis a key feature for the EPS 7000 with up to 94 percentsystem efficiency at full load. EPS 7000 provides pureflexibility, with auxiliary equipment such as parallelinggear, external maintenance bypass, critical bussynchronization, bottom entry cabinets, and distributionto meet specific site configuration while maximizingefficiency and output power quality.EPS 7000Availability Higher power density Low kVAR filter Redundant parallel logic Integrated output isolation transformerManageability Adaptable configurations Advanced battery management Remote power monitoring Built-in modbusServiceability Front‑access design Modular rectifier and inverter subassembly Intuitive standard graphical displayOptions Input galvanic isolation Battery cabinet Bypass cabinet Bottom entry cabinetEconomy Low installation costs Reduced footprint Low CapEx solutionSimplified installation Top entry standard Comprehensive installation proceduresApprovals UL1778 CULTypical applications Data center Industrial Healthcare Petrochemical UtilitySupport and service Extended warranty plans Worldwide field service organization Available project management servicesschneider-electric.com 3

EPS 7000 featuresDigital power quality inverterUsing a unique technology called Digital Power Quality Management, the invertermaintains precision voltage regulation under all operating conditions. The key tothe superior performance lies in the speed and resolution of the waveform, which isgenerated by up to eight pulses per millisecond, allowing the waveform to be tightlycontrolled. The waveform is constantly compared to a real‑time reference sine wave.If the sine wave deviates from the reference sine wave, the gain of the inverter outputis adjusted, creating a “correction” pulse maintaining a “power quality envelope”that is /-1 percent of a perfect sine wave. A free-switching frequency acceleratesduring periods of major variations for better regulation. By optimizing the switchingfrequency, the EPS 7000 is also able to minimize switching losses and maintain ahigh efficiency level even at lower loads.Digital power quality logicDigitalwave formcorrectionFeedbackon waveform qualityReal-time referencesine waveAnother benefit of the high-resolution control topology is that harmonic distortionreflected from the loads is practically eliminated.UPS input filter technologyThe technology used to maintain the input power factor and avoid leading powerfactor (PF) loads is an important consideration. Many other large UPS modules relyon disengaging the input filter capacitors with a contactor at lower loads wherethe UPS risks becoming a leading PF load. Switching capacitors will create largenotches and disturbances on the utility bus. Furthermore, the system is relying on amechanical contactor. Our system is based strictly on a solid state inductor assemblybalancing the effect of the capacitors — a safe and reliable technology.Free-frequencyswitchingQuality bandwith variations 1%Output voltage curveUp to 8 commutationsper millisecondChargerInput filter4 schneider-electric.com

EPS 7000 featuresSolid state disc SCR transfer switchEPS 7000 uses large hockey puck silicon-controlled rectifiers (SCRs) in its static bypass.The ability to clear faults safely is dictated by the capacity of the static bypass switch.Because these SCRs can tolerate quick fault currents over 20 times that of the UPS rating,they can safely use the fault‑clearing power of the utility to clear the fault without anydamage to the UPS.Many other UPS modules typically use lower-current brick-type SCRs on their static switchesthat are only momentary rated and rely on an overlap contactor to carry the current.Because fault current rises so quickly, it can often exceed the rating of these momentarySCRs before the contactor has a chance to engage. The fault clearing capability of the UPSis regulated by capacity of the static bypass switch. The EPS 7000 uses a robust disc SCRstatic bypass switch that is able to clear instantaneous fault current over 20 times the nominalrating of the UPS. The EPS 7000 bypass is 100 percent continuous duty rated, making itmore reliable than systems that pair smaller, momentary bypass switches.Fault tolerantOutput faults are common events on any UPS system. Even a small downstream devicefault may take four or five cycles before a distribution circuit breaker opens. This meansthat the UPS module must be capable of clearing the fault. Insulated-gate bipolartransistors (IGBTs) used in the inverters simply are not designed to sustain faults. The keyto managing faults is to firstly protect the inverter by current limiting it from fault conditions— and then safely make a seamless transfer to utility via the static bypass switch. Theresult is that the load will stay protected and the UPS will remain intact.Static switchMomentary switchStatic switchContinuous duty switchNew standard graphical user interfaceThe advanced graphical interface for the EPS 7000 UPSsystem features a 12-inch high-contrast TFT LCD touchscreen. Delivering features including animated mimicdiagrams, alarm event logs, trending, component levelstatus, and more, the interface presents UPS statusinformation in an easy-to-read graphical format. Guidedby a clear menu, users can navigate through all screensto explore system level information on multimodulesystems drilling right down to module and componentlevel information. Operator procedures simplify the use ofthe UPS, contributing to an overall increase in reliability bymitigating user errors.schneider-electric.com 5

EPS 7000 optionsInput isolation transformerSeismic complianceEPS 7000 has the capability to include a matching inputisolation transformer cabinet within the UPS lineup.Integrating the transformer directly into the lineup moduleprovides all the benefits of galvanic isolation, including avery robust buffer between the utility and the critical load.EPS 7000 modules are compliant with IBC 2006 (International Building Code)and OSHPD. Proper sizing and placement of seismic brackets is imperative inadequately restraining equipment against seismic effects. EPS 7000seismic mounts and restraints are designed to provide strength during anevent. EPS 7000 installation drawings will guide you in proper installation.OptionsEPS 7000 single module Input isolation transformerMaintenance bypass cabinet (optional) Output distributionQ3BP External maintenance bypassThis feed required for 3CB maintenance bypass only Bottom cable entrySource 2 input Remote alarm status panelQ4SThis feed not required with 3CB maintenance bypass Seismic anchors Simple network management protocol (SNMP)/network management card Battery monitoringRectifierSource 1 input Continuous-duty and momentary-dutystatic switch cabinets (SSCs)Input CBInputfilter Critical bus synchronization moduleRS232/RS485JBus interface Battery itchQF1battery disconnectSingle or dual input configurations availableEPS 7000 parallel module with System SSCThis feed required for 3CBmaintenance bypass onlyQ3BPThis feed required for 2CBmaintenance bypass onlyUPS 1Rectifier al)Q5NTo criticalloadInput filterSystemSSCUPS 2Inputswitchboard(optional)RS232/RS485JBus interface6 schneider-electric.comRemote alarmstatic panel(optional)Remotesummary alarmpanel (optional)Note: SSC can parallel up tosix modules up to 4000 AQ5NCriticalload

Specific technical advantagesBattery managementEnergy efficient for significant cost savingsBatteries represent a significant investment inany UPS system — often half the cost. They also havethe highest risk of failure of any component. TheEPS 7000’s battery management system performs twocritical functions. First, it collects all the relevant inputsto display the most accurate time remaining. Then, byincorporating key details such as battery temperature,the EPS 7000 rectifier continually optimizes the chargevoltage to maximize battery life.The energy efficiency of the EPS 7000 is extremely high,especially at lower loads where redundant UPS modulesoperate. The result is often energy cost savings thatusually exceed the cost of the UPS module in as little asthree to five years compared to leading brands.Full output voltage regulationover entire range of the battery Core efficiency up to 94 percent High efficiency maintained over lowerload levels where most UPS modules operate Potential energy cost savings that can equalthe value of the UPS in as little as a few years100%The EPS 7000 uses a 480 V DC bus. As a result of theDC bus closely matching the AC output voltage, the UPSis able to maintain the output voltage regulation over thewhole operating range of the battery. Some UPS modulesthat use lower DC buses (using fewer batteries in series)may experience decaying output voltage as the batteryvoltage/DC bus drops during discharge. This means thatthe EPS 7000 UPS will be able to maintain perfect voltageregulation over the full range of the battery.93%Energysavings0%NonoptimizedIGBT UPS efficiency35/40%100%schneider-electric.com 7

StruxureWare for Data Centers software suiteAPC by Schneider Electric UPS units and secure power systems are core componentsof any architecture designed for highly critical applications, such as data centers,industry environments, infrastructure, and buildings.TMIntelligent energy management of these systems is enabled by Schneider ElectricEcoStruxure integrated hardware and software system architecture. StruxureWaresoftware applications and suites are a key element of the EcoStruxure architecture.StruxureWare software helps maximize system reliability and optimize operationalefficiency.TMTMStruxureWare for Data Centers software collects and manages real-time informationabout assets, resource use, and operation status throughout the data center life cycle.This data center infrastructure management software fully integrates the EPS 7000 UPS.With full system visibility, managers can monitor and apply this information in order tooptimize data center performance to meet IT-, business-, and service-oriented goals.A comprehensive portfolio of servicesSchneider Electric Critical Power & Cooling Services provides the highest quality services andsolutions by trained and trusted professionals. Our world-class services offer a smart way tobuild, operate, and maintain your critical applications, ensuring the right people, in the rightplace, at the right time.Assembly and start-up serviceRemote Monitoring Service (RMS)Assembly and start-up service by a certified Field Service Engineer(FSE) ensures full factory warranty coverage. A Schneider Electriccertified installation of your solution ensures your equipment is properlyand safely configured for optimal performance. This service features astandard eight-hour, five-day response time, with upgrades availablefor off-business hours.RMS is an economical and easy-to-use Web-based service that lets youquickly respond to environmental or system changes. Trained techniciansprovide secure 24-hour monitoring of your physical infrastructure todiagnose and resolve problems before they become critical.Advantage plansPreventive maintenance on-site examinations of your critical systems aredesigned to prevent problems before they occur and keep your systemrunning at maximum efficiency.Flexible service packages offer hassle-free system maintenance toimprove uptime at a predictable cost. These packages provide yoursystem with the care it needs to operate most efficiently while minimizingdowntime. The Advantage Plus, Prime, Ultra, and Max are full-servicepackages that include technical support, preventive maintenance,quick on-site response, and remote monitoring. Response timeupgrades are available.8 schneider-electric.comPreventive maintenanceOn-site warranty extension serviceIn the event of a system issue, an FSE will arrive on site by the nextbusiness day to isolate, diagnose, and correct the problem in aslittle time as possible, minimizing downtime. Upgrades to even fasterresponse times are available.

Technical specificationsRated power Normal AC inputInput voltage (V)480 ( /- 10% , 3ph 3 wire ground)Frequency (Hz)600 ( /- 10% , 3ph 3 wire ground)60 Hz 5%Power factor0.9THDi (full load)300 kVA (10%), 400 kVA (8%), 500 kVA (7%)Nominal input current (A)371508656322441569Maximum input current (A)453590738404523652Bypass AC inputVoltage (V) /- 10% UPS output voltage (3ph, 3/4 wire ground)Frequency (Hz)Nominal bypass current (A)60 Hz ( /- 0.25 Hz up to 2.0 Hz)361481601289385481OutputOutput voltage (V)480 (3ph 3 or 4 wire ground)600 (3ph 3 or 4 wire ground)Power factor0.9FrequencyUPS output current (A)60 0,75086,000112,000BatteryDC current (max)Overall efficiencySystem efficiency (full load)Full load heat rejection (BTUs)94%59,40093%93%65,00092.5%Environmental conditionsAcoustical noise levelOperating temperature75 dBA at 5 feet0 to 40 C (32 to 104 F)Non-operating-20 to 45 C (-4 to 113 F)Relative humidity0 to 90% (noncondensing)Dimensions and weightsUPS module (lb.)UPS module (W x H x D)Maintenance bypass cabinet (lb.)Maintenance bypass cabinet (W x H x D)Bottom entry cabinet (lb.)Bottom entry cabinet (W x H x D)Transformer cabinet (lb.)6,90069 x 82 x 39 in.54022.75 x 82 x 39 in.19014 x 82 x 39 in.3,600NOTE: Due to continued product enhancements, specifications are subject to change without notice. Data above is for reference only— not construction. Schneider Electric assumes no liability for damages as a result of any data errors or omissions in this document.Consult product guide specifications and installation drawings for further details.schneider-electric.com 9

Schneider Electricemail: esupport@apc.com132 Fairgrounds Road,West Kingston,RI 02892 USAwww.schneider-electric.comNovember 2016 2016 Schneider Electric. All Rights Reserved. Schneider Electric Life Is On is a trademark and the propertyof Schneider Electric SE, its subsidiaries, and affiliated companies. 998-5823 GMA-US BThis document has beenprinted on recycled paper

StruxureWare for Data Centers software collects and manages real-time information about assets, resource use, and operation status throughout the data center life cycle. This data center infrastructure management software fully integrates the EPS 7000 UPS. With full system visibility, managers can monitor and apply this information in order to