7SR11 & 7SR12 Settings & Instruments Guide - Siemens

Transcription

ReyrolleProtectionDevices7SR10 ArgusOvercurrent Relay

2020 Siemens Protection Devices2

7SR10 Argus ContentsContentsTechnical Manual Chapters1.Description of Operation2.Settings & Instruments Guide3.Performance Specification4.Data Communications5.Installation6.Commissioning and Maintenance7.Applications GuideThe copyright and other intellectual property rights in this document, and in any model or article produced from it(and including any registered or unregistered design rights) are the property of Siemens Protection Devices. Nopart of this document shall be reproduced or modified or stored in another form, in any data retrieval system,without the permission of Siemens Protection Devices, nor shall any model or article be reproduced from thisdocument unless Siemens Protection Devices Limited consent.While the information and guidance given in this document is believed to be correct, no liability shall be acceptedfor any loss or damage caused by any error or omission, whether such error or omission is the result ofnegligence or any other cause. Any and all such liability is disclaimed. 2020 Siemens Protection Devices

7SR10 Description of Operation7SR10Description of OperationDocument Release HistoryThis document is issue 2020/03. The list of revisions up to and including this issue is:2020/03Seventeenth Issue2020/03Sixteenth Issue2019/12Fifteenth Issue2019/05Fourteenth Issue2019/01Thirteenth Issue2018/07Twelfth Issue2018/06Eleventh Issue2017/09Tenth Issue2017/07Ninth Issue2017/04Eighth Issue2017/03Seventh Issue2016/11Sixth Issue2015/09Fifth Issue2015/06Fourth Issue2015/03Third Issue2015/02Second Issue2013/11First IssueThe copyright and other intellectual property rights in this document, and in any model or article produced from it(and including any registered or unregistered design rights) are the property of Siemens Protection Devices. Nopart of this document shall be reproduced or modified or stored in another form, in any data retrieval system,without the permission of Siemens Protection Devices, nor shall any model or article be reproduced from thisdocument unless Siemens Protection Devices Limited consent.While the information and guidance given in this document is believed to be correct, no liability shall be acceptedfor any loss or damage caused by any error or omission, whether such error or omission is the result ofnegligence or any other cause. Any and all such liability is disclaimed. 2020 Siemens Protection Devices

7SR10 Description of OperationSoftware Revision History (7SR1002/7SR1003)2019/122437H80001R4k-2fFirmware Maintenance2019/012437H80001 R4j-2eFirmware Maintenance2018/052437H80001 R4h-2dFirmware Maintenance2017/092437H80001 R4d-2cData Communications improvements2017/042437H80001 R4c-2bMinor modification in Analog2016/112437H80001 R4b-2bSupport for Reydisp manager tool2015/092437H80001 R4b-2aAddition of AR variants2015/062437H80001 R4b-1f81THD function added2015/032437H80001 R4b-1eAddition of non-directional SEF device variants2015/022437H80001 R4b-1dFirst Maintenance2013/112436H80015 R2d-1aFirst ReleaseSoftware Revision History (7SR1004)2020/032437H80008R4k-1cAddition of Directional Sensitive Earth Fault (67SEF) –Measured 3V0/I0-Φ2019/122437H80008R4j-1cFirmware Maintenance2019/052437H80008 R4j-1b50AFD, 50LC, ITHD, Wattmetric functions added2018/062437H80008 R4h-1aFirst ReleaseHardware Revision History (7SR1002/7SR1003)2019/087SR10/EESecond Release2015/017SR10/DDFirst ReleaseHardware Revision History (7SR1004)2019/087SR10/EESecond Release2018/077SR10/DDFirst ReleaseThe copyright and other intellectual property rights in this document, and in any model or article produced from it(and including any registered or unregistered design rights) are the property of Siemens Protection Devices. Nopart of this document shall be reproduced or modified or stored in another form, in any data retrieval system,without the permission of Siemens Protection Devices, nor shall any model or article be reproduced from thisdocument unless Siemens Protection Devices Limited consent.While the information and guidance given in this document is believed to be correct, no liability shall be acceptedfor any loss or damage caused by any error or omission, whether such error or omission is the result ofnegligence or any other cause. Any and all such liability is disclaimed. 2020 Siemens Protection Devices

7SR10 Description of OperationContentsSection 1: Introduction . 91.1 Current Transformer Circuits. 91.2 External Resistors . 91.3 Description . 91.4 Ordering Options . 101.5 Functional Diagram . 121.6 Terminal Diagram . 131.6.1Terminal Diagram with Control Push Buttons . 13Section 2: Hardware Description. 152.1 General . 152.2 Front Fascia . 162.2.1Front Fascia with Control Push Buttons . 162.3 CB Open/Close . 162.4 Power Supply Unit (PSU) . 172.5 Connectors. 182.5.1Connectors with Control Push Buttons . 182.6 Relay Information . 182.7 Operator Interface . 202.7.1Liquid Crystal Display (LCD) . 202.7.2LCD Indication . 202.7.3Standard Keys . 202.7.4Protection Healthy LED . 212.7.5Indication LEDs . 212.8 Current Inputs . 212.9 Voltage Inputs . 222.10 Binary Inputs . 222.11 Binary Outputs (Output Relays) . 222.12 Virtual Input/Outputs . 232.13 Self Monitoring . 242.13.1 Protection Healthy/Defective . 25Section 3: Protection Functions . 263.1 Current Protection: Phase Overcurrent (67, 51, 50). 263.1.1Directional Control of Overcurrent Protection (67) . 263.1.2Instantaneous and DTL Overcurrent Protection (50) . 273.1.3Time Delayed Overcurrent Protection (51). 283.1.4Current Protection: Voltage Controlled Overcurrent (51V) . 303.2 Current Protection: Derived Earth Fault (67N, 51N, 50N) . 313.2.1Directional Control of Derived Earth Fault Protection (67N) . 313.2.2Instantaneous and DTL Derived Earth Fault Protection (50N) . 323.2.3Time Delayed Derived Earth Fault Protection (51N) . 333.3 Current Protection: Measured Earth Fault (67G, 51G, 50G) . 353.3.1Directional Control of Measured Earth Fault Protection (67G) . 353.3.2Instantaneous and DTL Measured Earth Fault Protection (50G) . 363.3.3Time Delayed Measured Earth Fault Protection (51G) . 373.4 Current Protection: Sensitive Earth Fault (67SEF, 51SEF, 50SEF) . 383.4.1Directional Control of Sensitive Earth Fault Protection (67SEF) . 383.4.2Instantaneous and DTL Sensitive Earth Fault Protection (50SEF) . 393.4.3Directional Sensitive Earth Fault (67SEF) – Measured 3V0/I0-Φ . 413.4.4Time Delayed Sensitive Earth Fault Protection (51SEF) . 423.4.5Current Protection: High Impedance Restricted Earth Fault - (64H) . 443.4.6Current Protection: Cold Load (51C). 443.4.7Current Protection: Negative Phase Sequence Overcurrent - (46NPS) . 453.4.8Current Protection: Under-Current (37) . 463.4.9Current Protection: Thermal Overload (49) . 473.4.10 Current Protection: Line Check 50LC,50G LC, and 50SEF LC – Only software option ‘C’ . 493.4.11 Protection: Arc Flash Detector (50 AFD) . 513.4.12 Voltage Protection: Phase Under/Over Voltage (27/59). 523.4.13 Voltage Protection: Negative Phase Sequence Overvoltage (47NPS) . 53 2020 Siemens Protection DevicesChapter 1 Page 3 of 86

7SR10 Description of Operation3.4.143.4.153.4.163.4.173.4.18Voltage Protection: Neutral Overvoltage (59N) . 53Voltage Protection: Under/Over Frequency (81) . 55Power Protection: Power (32) . 56Power Protection: Sensitive Power (32S) . 57Power Protection: Power Factor (55) . 58Section 4: Auto-Reclose (79) Optional Function . 594.1.1Overview . 594.1.2Auto Reclose sequences . 614.1.3Autoreclose Prot’n Menu . 624.1.4Autoreclose Config Menu . 624.1.5P/F Shots sub-menu . 634.1.6E/F Shots sub-menu . 634.1.7SEF Shots sub-menu . 634.1.8External Shots sub-menu . 634.2 Quick Logic . 664.3 Manual CB Control . 674.4 Circuit Breaker (CB) . 68Section 5: Supervision Functions . 705.1 Circuit Breaker Failure (50BF) . 705.2 2nd Harmonic Block/Inrush Restraint (81HBL2) Phase Elements Only . 715.3 Total Harmonic Distortion Supervision (81I THD) . 715.4 VT Supervision (60VTS) . 725.5 CT Supervision (60CTS) . 745.5.160CTS-I. 745.5.260CTS . 745.6 Broken Conductor (46BC) . 755.7 Trip/ Close Circuit Supervision (74TCS & 74CCS) . 75Section 6: Other Features . 776.1 Data Communications . 776.1.1Communication Ports . 776.2 CB Maintenance . 806.2.1Output Matrix Test . 806.2.2CB Counters . 806.2.3I2t CB Wear . 816.3 Data Storage . 816.3.1General . 816.3.2Demand . 816.3.3Event Records . 826.3.4Waveform Records . 826.3.5Fault Records. 826.3.6Energy Storage . 836.3.7Disk Activity Warning . 836.4 Metering . 846.5 Operating Mode . 846.6 Control Mode . 856.7 Real Time Clock . 856.7.1Time Synchronisation – Data Communication Interface . 856.7.2Time Synchronisation – Binary Input . 856.8 Settings Groups . 856.9 User Specific Curves. 866.10 Confirmation ID (Password Feature). 86 2020 Siemens Protection DevicesChapter 1 Page 4 of 86

7SR10 Description of OperationList of FiguresFigure 2-1Figure 2-2Figure 2-3Figure 2-4Figure 2-5Figure 2-6Figure 2-7Figure 2-8Figure 2-9Figure 2-10Figure 2-11Figure 3-1Figure 3-2Figure 3-3Figure 3-4Figure 3-5Figure 3-6Figure 3-7Figure 3-8Figure 3-9Figure 3-10Figure 3-11Figure 3-12Figure 3-13Figure 3-14Figure 3-15Figure 3-16Figure 3-17Figure 3-18Figure 3-19Figure 3-20Figure 3-21Figure 3-22Figure 3-23Figure 3-24Figure 3-25Figure 3-26Figure 3-27Figure 3-28Figure 3-29Figure 3-30Figure 3-31Figure 3-32Figure 3-33Figure 3-34Figure 4-1Figure 4-2Figure 4-3Figure 4-4Figure 5-17SR10 Argus Overcurrent Relay with Control Push Buttons. 167SR10 Non-Directional and Directional Overcurrent Relay with Connectors . 18Relay Rating Label. 19Fascia Relay Rating Label . 19Close up of Relay Identifier . 20LED Indication Label . 21Binary Input Logic . 22Binary Output Logic . 23Start-up Counter Meter . 24Unexpected Restarts Lockout Text . 24Start-up Events . 25Logic Diagram: Directional Control of Overcurrent Protection (67) . 27Logic Diagram: Instantaneous and DTL Overcurrent Protection . 28Logic Diagram: Time Delayed Overcurrent Protection . 29Logic Diagram: Voltage Controlled Overcurrent Protection . 30Logic Diagram: Directional Control of Derived Earth Fault Protection. 31Logic Diagram: Instantaneous and DTL Derived Earth Fault Protection . 32Logic Diagram: Time Delayed Derived Earth Fault Protection . 34Logic Diagram: Directional Control of Measured Earth Fault Protection . 35Logic Diagram: Instantaneous and DTL Measured Earth Fault Protection . 36Logic Diagram: Time Delayed Measured Earth Fault Protection (51G) . 37Logic Diagram: Directional Control of SEF Protection (67SEF) . 39Logic Diagram: 7SR1003 Instantaneous and DTL SEF Protection . 39Logic Diagram: 7SR1004 Instantaneous and DTL SEF Protection . 40Logic Diagram: 7SR1004 Directional Sensitive Earth Fault – Measured 3V0/I0-Φ . 41Logic Diagram: 7SR1003 Time Delayed SEF protection . 42Logic Diagram: 7SR1004 Time Delayed SEF Protection . 43Logic Diagram: High Impedance REF (64H) . 44Logic Diagram: Cold Load Settings (51C) . 45Logic Diagram: Negative Phase Sequence Overcurrent (46NPS) . 46Logic Diagram: Phase Current Inputs Undercurrent Detector (37) . 47Logic Diagram: Earth Current Inputs Undercurrent Detector (37G) . 47Logic Diagram: Sensitive Earth Current Inputs Undercurrent Detector (37SEF). 47Logic Diagram: Thermal Overload Protection (49) . 48Logic Diagram: 50G Line Check Elements (50G LC). 49Logic Diagram: 50SEF Line Check Elements (50SEF LC) . 49Logic Diagram: 50 Line Check Elements (50LC) . 50Logic Diagram: Arc Flash Detector (50 AFD) . 51Logic Diagram: Under/Over Voltage Elements (27/59) . 52Logic Diagram: NPS Overvoltage Protection (47) . 53Logic Diagram: Neutral Overvoltage Element (59N) . 54Logic Diagram: Under/Over Frequency Detector (81). 55Logic Diagram: Power Protection (32) . 56Logic Diagram: Sensitive Power Protection (32S) . 57Logic Diagram: Power Factor Protection (55) . 58Typical AR Sequence with 3 Inst and 1 Delayed trip . 61Basic Auto-Reclose Sequence Diagram . 65Sequence Diagram: Quick Logic PU/DO Timers (Counter Reset Mode Off) . 66Logic Diagram: Circuit Breaker Status . 69Logic Diagram: Circuit Breaker Fail Protection (50BF) . 70 2020 Siemens Protection DevicesChapter 1 Page 5 of 86

7SR10 Description of OperationFigure 5-2Figure 5-3Figure 5-4Figure 5-5Figure 5-6Figure 5-7Figure 5-8Figure 5-9Figure 6-1Figure 6-2Figure 6-3Figure 6-4Figure 6-5Figure 6-6Figure 6-7Logic Diagram: Harmonic Block Feature (81HBL2) . 71Logic Diagram: Total Harmonic Distortion Supervision Element (81I THD) . 72Logic Diagram: VT Supervision Function (60VTS). 73Logic Diagram: CT Supervision Function (60CTS) . 74Logic Diagram: CT Supervision Function (60CTS) . 74Logic Diagram: Broken Conductor Function (46BC) . 75Logic Diagram: Trip Circuit Supervision Feature (74TCS) . 75Logic Diagram: Close Circuit Supervision Feature (74CCS) . 76Communication to Front USB Port . 77Connect Icon . 77Port Selection in Connection Manager. 78System Information Icon . 78System Information Icon . 79Communication to Multiple Devices from Control System using RS485 . 80Energy Direction Convention . 83 2020 Siemens Protection DevicesChapter 1 Page 6 of 86

7SR10 Description of OperationList of TablesTable 2-1 Summary of 7SR10 Argus Overcurrent Relay Configurations . 15Table 6-1 Operation Mode . 84 2020 Siemens Protection DevicesChapter 1 Page 7 of 86

7SR10 Description of OperationSymbols and NomenclatureThe following notational and formatting conventions are used within the remainder of this document: Setting Menu LocationMAIN MENU SUB-MENU Setting:Elem name -Setting Setting value:value Alternatives:[1st] [2nd] [3rd] 2020 Siemens Protection DevicesChapter 1 Page 8 of 86

7SR10 Description of OperationSection 1: IntroductionThis manual is applicable to the following relay: 7SR10 Overcurrent RelayGeneral Safety Precautions1.1!1.2!1.3Current Transformer CircuitsThe secondary circuit of a live CT must not be open circuited. Non-observance of this precaution canresult in injury to personnel or damage to equipment.External ResistorsWhere external resistors are connected to the relay circuitry, these may present a danger of electricshock or burns, if touched.DescriptionThe 7SR10 Overcurrent relay is developed by using the latest generation of hardware technology and is availablein multiple variants depending on power supply, binary input/output configuration, voltage input, and datacommunication facility. 7SR10 is a member of Siemens Reyrolle protection devices Argus product family.The 7SR10 overcurrent relay consists of non-directional functions and with additional voltage inputs providingdirectional functions (based on the ordering option).The 7SR10 Overcurrent relay is housed in a 4U high, size 4 non draw-out case and these

7SR11 & 7SR12 Settings & Instruments Guide - Siemens . Delayed).