System 1* Version 6.81Optimization and Diagnostics SoftwareDescriptionSystem 1* Software is a patented, modular machinery management platform forprocess and equipment optimization, condition monitoring and eventdiagnostics. The client/server-based architecture is both scalable and flexible.This allows you to focus on your most critical needs and then continue to expandyour system by adding new application packages and system extenders.System 1 software integrates all of this into a single system, with a single displayenvironment and common database structure.The System 1 platform enables operators, equipment engineers, processengineers, instrument technicians, and other plant personnel to quickly identify,evaluate, and respond to important events to optimize the business impact. Thisincreases equipment availability and reliability, and reduces maintenance costs.A growing suite of specially-designed application packages exists to meet theneeds of individual plant equipment and users. These packages supplement theSystem 1 Platform and support high-resolution data acquisition, trending,alarming, exception reporting, and user notification.The highly modular architecture of the System 1 software facilitates theexpansion of data acquisition capabilities and the addition of machinery/assetmanagement tools. These tools provide connectivity to the Snapshot* forWindows CE portable data collector, TDXnet*, TDe and TDI communicationsprocessors, 1701 FieldMonitor* system, OPC, Modbus devices, DynamicScanning Module for the Trendmaster* Pro system, and Essential Insight.mesh*.System 1 software also provides a suite of System Extender* applications tocomplement and expand the capability of the system. These applications includeoptions for CMMS Interfaces (SAP PM and MRO Maximo interfaces), DataExporters (OPC A&E, OPC DA, and OLE Automation), Event Relay Card software,Smart Notifier, State-Based Analysis, AnomAlert* motor and generator anomalydetection, and The Bearing Expert software. In addition, the Decision Support*Studio with Rule Logic Results allows users to embed their domain knowledgeinto the system. These extender applications permit the system to evaluate realtime data, generate sophisticated alerts and alarms, and produce intelligentadvisories that deliver Actionable Information* data to designated users.The System 1 platform employs Microsoft Server technology for dataacquisition and Decision Support functionality. It also uses a specializedMicrosoft SQL database design for fast data storage, event capture and history,equipment properties and configuration information. The system provides avariety of industry standard interfaces to integrate with control and automationapplications. System 1 software has been developed specifically for theMicrosoft Windows XP/Vista/7/2003/2008 operating systems to provide userswith a familiar interface and significant installed base of these industry standardoperating systems.Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 1 of 15

Table 1: The System 1 ApplicationPackagesApplication NameTurbo MachineryHydro MachineryElectrical/MultilinAssetsWind zationPortable DataCollectorEssentialInsight/TrendmasterProStatic DataManagementLubricant AnalysisData ImportFunctionAdvanced on-line conditionmonitoring and diagnosticsoftware package for criticalrotating machinery applications.Features sophisticated vibrationdiagnostics capabilities.Advanced on-line machinecondition monitoring anddiagnostic software package forhydro turbines and generators.Included specialized diagnosticstools and measurement support.Advanced on-line electricalequipment condition monitoringand diagnostic software packagefor motors, generators, andtransformers.Advanced on-line machinecondition monitoring anddiagnostic software package forwind turbines.Advanced on-line mechanical andperformance condition monitoringand diagnostic software packagefor critical reciprocating machineryapplications. Includessophisticated Pressure-Volumeanalysis capabilities.Provides plots associated tothermodynamic performance data(note: the PerformanceVisualization Application Packagedoes not include the calculation ofthermodynamic data). Optionalpre-engineered calculationtemplates (Bently PERFORMANCE*software) are available formachines such as gas turbines,compressors, pumps, steamturbines, and generators.Portable walk-around applicationsupporting the Snapshot family ofportable data collectors. Thisincludes a two-channel, onechannel IS, and PDA portables foroperator rounds.Supports both EssentialInsight.mesh and Bently Nevada*Trendmaster Pro online scanningsystems intended for managingessential and balance-of-plantmachinery.Provides a suite of plots to managestatic data collected using industrystandard protocols, as well as fromBently Nevada protection systems.Provides tools to import and viewlube oil analysis reports, analysisalerts, analysis diagnostics to beused in data correlation and assetcondition monitoring.Table 2: The System 1 System ExtenderApplicationsApplication NameCMMS Interfaces(MAXIMO and SAP)13Rule Logic ResultsState-Based AnalysisSmart NotifierEvent Relay Card andSoftwareThe Bearing ExpertGEnyusFunctionProvides an interface to selectComputerized MaintenanceManagement Systems. Includesability to link to CMMS assets, viewwork history, Manual workrequest, and Automated workrequest.Decision Support rules use inputsand generate outputs (events,calculations, etc.). In order forrules to be processed, Rule LogicResults must be available in thesystem. This provides scaleablereal-time rule processing.State-based monitoring providesmore sophisticated diagnostics ofmachines, with the ability todefine machine states that cancontrol data storage, filter plotdata, and help correlate processdata with machinery data.Smart Notifier is a stand-aloneapplication that filters eventsmuch like Notification Plans butcollects them in one place whereeach user can check on events forwhich he or she is responsible.The Event Relay Notificationcomponent can trip a relay inresponse to an event of aspecified type, severity and assetlocation. Works with the DecisionSupport Application.Enhances configuration ofmachines with rolling elementbearings by providing a bearingdatabase. Identifies keyparameters based onManufacturer, model ordimension of the bearing.Software works with System 1Configuration. Install on theConfiguration computer.GEnyus provides anomalydetection for GE Oil & GasReciprocating Compressors byleveraging OEM design andperformance expertise. Detectedanomalies are available throughSystem 1 Display.Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 2 of 15

Rightrax Corrosion &Erosion MonitoringAnomAlertEnables on-line conditionmonitoring of critical fixedassets (piping and vessels) viaRightrax wall thicknessmeasurements, data logging,and communicationsinfrastructure. Data can bedisplayed, stored, and plottedas trends and managed viaSystem 1 alarms.Enables data collection viaOPC from the AnomAlertEnterprise Server (AES). Youmust order 390125-01 for theAES software. Reference DataSheet 286754-01 forinformation regardingordering the AnomAlerthardware.Table 3: The System 1 Data ImportersTypeFunctionTDI TransientProvides dynamic, static, transientand steady state data from a 3500TDI channel. There is no need topurchase a separate TDI Enabler.Applies to all TDI channels with awaveform enabled for transient datacollection. (Exceptions are forchannels used in ReciprocatingCompressor and Hydro applications– see below.)Provides dynamic, static and steadystate data from a 3500 TDI channel.There is no need to purchase aseparate TDI Steady State Enabler.Applies to all TDI channels with awaveform enabled for steady statedata collection. (Exceptions are forchannels used in ReciprocatingCompressor and Hydro applications– see below.)Provides dynamic, static and steadystate data from a 3500 TDI channelused in Reciprocating Compressorapplications. There is no need topurchase a separate TDI Enabler.Applies to all TDI channels on the3500/70M, 72M and 77M monitors.Provides dynamic, static and steadystate data from a 3500 TDI channelused in Hydro applications. There isno need to purchase a separate TDIEnabler. Applies to TDI channels onthe 3500/46M that have waveformsenabled.TDI Steady StateTDI Recip SteadyStateTDI HydroTDe TransientTDe Steady StatePortable DataCollector PointsTrendmaster ProPointsDCS/HistorianTagsEssentialInsight.mesh StaticPoints.EssentialInsight.meshDynamic Points.Bently NevadaMonitor StaticChannelsDynamic Channels(Non TDI/TDe)Electrical/MultilinDevicesProvides dynamic, static, transientand steady state data from a 3300TDe channel. There is no need topurchase a separate TDe Enabler.Applies to all TDe channels with awaveform enabled for transient datacollectionProvides dynamic, static and steadystate data from a 3300 TDe channel.There is no need to purchase aseparate TDe Steady State Enabler.Applies to all TDe channels with awaveform enabled for steady statedata collection.Provides dynamic and static datafrom portable data collector devices.Provides dynamic and static datafrom a Trendmaster Pro system.Provides data from OPC and Modbusdevices.Provides static temperature andvibration data from an EssentialInsight.mesh network.Provides dynamic vibration datafrom an Essential Insight.meshnetwork.Provides static data from channelson Bently Nevada monitors that donot have a waveform enabled.Provides dynamic and static datafrom communications processorsother than 3500 TDI and 3300 TDe.Applies to channels that havewaveforms enabled.Provides all static and dynamic data(if dynamic data is applicable)collected from a Multilin device.Supported Multilins include: G60Generator Management Relay*, 489Generator Management Relay*,269Plus Motor Management Relay*,369 Motor Management Relay*, 469Motor Management Relay*, M60Motor Management Relay, PowerQuality Meter (PQM), T60Transformer Management Relay*,T35 Transformer ManagementRelay*, 745 TransformerManagement Relay*, and 750Transformer Management Relay*products.Table 4: The System 1 Data ExportersTypeFunctionData ExportersExports real-time data from System1 to the DCS, Historians, etc.Includes OPC A&E, OPC DA and OLE.Exports real-time data andconfiguration information fromYokogawa PRM Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 3 of 15

System 1 to Yokogawa’s PlantResource Manager (PRM) softwarevia OPC interface.Table 5: Additional System ComponentsApplicationNameData AcquisitionDatabase (SQLServer)Display andConfigurationFile BasedConfigurationSystem ntsFor demanding online DAQ (DataAcquisition) installations, westrongly recommend that you usean approved and tested servergrade computer. For a list ofapproved servers, please contactyour local Sales and Servicerepresentative.FunctionCommunicates and acquires datafrom many sources.Stores all historical machinery data,asset information, system hardware,and enterprise configuration.Displays all data on any connecteddata acquisition or databasestation. Configures the systemhardware and software.Allows rapid configuration of largenumber of process points byimporting/exporting to MicrosoftExcel. (System1 v6.81 supports Excelversion 2003 and greater.)Provides system administration andsystem health & performancefunctionality.Provides access to an EssentialInsight.mesh wireless networkwithin System 1. One license permanagement gateway (wirelessnetwork) is required.For limited portable, orDisplay/Configurationinstallations, the followingrequirements are therecommended minimum for theSystem 1 software to operate. Ifyour system does not meet theserequirements, the performance ofthe application may not beacceptable, and in some casesthe software will not run properly.We strongly recommend that youcontact your local Sales andService representative for a list oftested and approvedworkstations.The System 1 client/server architecture allows you toplace Display (client) stations anywhere within yourplant’s Local Area Network (LAN), Wide Area Network(WAN), or Remote Access Server, providing the abilityto display and share data with one or more dataacquisition (server) stations.System 1 software can share data with plant controland automation systems using OPC, or OLEAutomation protocols. Trendmaster Pro DSM canexport data to control and automation systemsusing Modbus. Data exporters that provideformatted output of all static variables and statusdata support a network interface. System 1 softwaresupports time-synchronization with other systems(e.g., process control or machine control systems)using appropriate computer peripherals andsoftware available from GE.2.83 GHz Intel Xeon processor2 GB RAM250 GB hard disk driveAvailable USB portDVD-ROM drive256 MB video cardOperatingSystem13Data Acquisition;Database (Microsoft SQLServer 10, 12) SoftwareWindows Server 2003 SP2Windows Server 2008 SP2Windows Server 2008 R2 x6415Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 4 of 15

Display; Configuration;Data Acquisition (SmallSnapshot Only) SoftwareSnapshot PortablePortable ISSnapshot Clipboard* via PDAWindows XP SP 3Note:Windows Vista SP2Windows 7Windows Server 2003 SP2Windows Server 2008SP213Windows Server 2008 R2 x6415Number ofsimultaneousDisplay/Configurationclients for DataAcquisition /SQL ServerStationWindowsServer 2003/Windows Server2008Maximum number ofCommunicationsProcessors (CP)/Equivalent FieldMonitorunits per dataacquisition station:12Maximum number ofTrendMaster Pro DSMsper data acquisitionstation:150Virtually unlimited simultaneousclients restricted by licenses/CALsWindows XP / Vista/Windows 710 simultaneous clients restrictedby licenses/CALsNote:See Snapshot Clipboard datasheet, part number 162458-01,for additional devices.When ordered from GE, server operating systems comewith 5 Client Access Licenses (CALs). Further, serveroperating system licenses are restricted to only be usedfor GE applications or in support of GE applications.Supported HardwareSystems may support the following hardwaredepending on the ordered Application Packages.System limitations are listed below.Supported MonitorSystems andCommunicationProcessor Types:3500, 3300, 2201, 1701TDI, TDXnet, TDIXconnX*, TDeSupportedPortable/ScanningTypes:Trendmaster Pro DSMEssential Insight.meshMaximum number ofnodes in an EssentialInsight.mesh network:100Maximum number ofpoints ( 100 nodes X 4points per node) in anEssential Insight.meshnetwork:400Maximum number ofEssential Insight.meshnetworks supported perDAQ (without exceeding2500 total points perDAQ limit):5Maximum number ofModbus devices perdata acquisition station:150Maximum number ofFieldMonitor units perdata acquisition station:36 (3 FieldMonitor units 1TDXnet CP)Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 5 of 15

Maximum number ofSnapshot devices perdata acquisition station:Unlimited5000 events/secondHigh RangeServer (requires4GB RAM)25,000 tags/DAQ serverNote: 1 Snapshot DAQ per EnterpriseMaximum number ofconfigurable machinetrains:UnlimitedMaximum number ofconfigurable portablepoints per enterprise:SQL Server onHigh RangeServer (requires4 GB RAM)Maximum trend filelengthUnlimited; dependent on availablesystem hard drive space.20,000 portable pointsNote: 1 Snapshot DAQ per EnterpriseMaximum number ofconfigurableonline/scanning points(includes TrendmasterPro, EssentialInsight.mesh andcommunicationprocessor points) perdata acquisition station:2500 total combinedonline/scanning pointsMaximum number ofconfigurable points perenterprise:45,000 (Limited only by themaximum number of points perdata acquisition station)Maximum number oflube test results:20,000:Total portable points luberesults may not exceed 20,000Data HistorianMaximum Limits(Process Data Only)Mid-RangeServer5,000 configured tags/DAQ serverSQL Server onMid-RangeServerMaximum number ofsystem/alarm eventsper data acquisitionstationUnlimited; dependent on availablesystem hard drive space.Maximum number ofconcurrent viewableevents10,000 events viewable withinevent list.Network SupportEthernetNetwork TransportProtocolsTCP/IPDisplay PlotsYou can select the following plots from stored data,Alarm Event Data, or Baseline Data. You can alsoconfigure Display to show only the applicable plotsfor any given application package. Current values Bargraph Machine train diagram Alarm/System event list Trend / Multivariable trend Tabular list Timebase (with option for superpositionof baseline data)Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 6 of 15

Orbit / Timebase (with option forsuperposition of baseline data) Orbit (with option for superposition ofbaseline data) Shaft average centerline Spectrum / Full spectrum (with optionfor superposition of baseline data)3060/00 System 13060/00-AXX X vs. YA: Waterfall / Full waterfall01 Polar/Acceptance region Bode0203 Cascade / Full cascade Reciprocating compressor plots Rod position Crank angle waterfall Crank angle overlay3060/01 System 1 Software and Licenses3060/01-AXX-BXX-CXX-DX-EXX-FXX-GXX Compressor mapsA: Exhaust gas temperature (EGT) Performance map Rotor stator profile Rotor shape9899 Hydro air gapNote: Phasor Histogram OctaveLanguagesSystem1 clients – Display, Configuration, SmartNotifier and DAQ Connection manager – have beentranslated into 10 non-English languages. Alanguage license is per Enterprise. The supportedoperating system for non-English translations is theEnglish version of Microsoft Windows. The OnlineHelp system is available only in English. Chinese (Simplified) Japanese Korean Spanish (European) German French (France) Russian Italian Finnish SwedishOrdering InformationStep 1Order Type9899New order (DVD, key, binder,Microsoft Excel)Expansion order (license key)Core System 1 software (DVDand binder)Replacement licenses (key)Update (DVD)Step 2 (Software)Order Type010203B:C:D:F:Option A is for information onlyand is the value chosen underStep 1.License Protection Type00None01USB key diskCustomer Type01Not available02AllQuantityXXNumber of new Enterpriseorders, from 1 to 10.Example: 1 1 order1 0 10 ordersNote:E:New order (DVD, key, binder,Microsoft Excel)Expansion order (key only)Core System 1 software (DVDand binder)Replacement licenses (key)Update (DVD)Training Accessories00010203Option D determines the quantityof new Enterprise orders (sets ofDVDs, binders, and MicrosoftExcel) and applies only to theOption A -01 option.NoneMachine Library CBTData Acquisition CBTMachine Library and DataAcquisition CBTTraining VoucherSpecifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 7 of 15

G:XXNumber of training vouchers,from 1 to 10.Example: 0 1 1 voucher1 0 10 vouchersXXNumber of printed manual,from 1 to 10.Example: 0 1 1 printed set1 0 10 printed setsNote:Printed manuals include thefollowing: the System 1 SoftwareInstallation Quick Start Guide andSystem 1 Software OperationsQuick Start Guide.B:C:D:Turbo MachineryXXXHydro MachineryXXXF:G:Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesNumber of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesElectrical/Multilin AssetsX X X Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesI:Static Data ManagementX X X Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesJ:Lubricant Analysis Data ImportX X X Number of new licenses, from0 to100Example: 0 0 0 0 licenses1 0 0 100 licenses3060/12 Display3060/12-AXXXXX-BXXXXXA:Number of Diagnostic Display Client Access LicensesXXXXXNumber of licenses, from0 to unlimitedExample: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licenses9 9 9 9 9 Unlimited licenses perEnterpriseB:Not Available3060/13 Data Export3060/13-AXXX-BXXX-CXXX-DXXX-EXXX-FXXA:OPC A&EWind TurbinesXXXE:Essential Insight/TM ProX X X Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesPrinted Manuals3060/10 Enterprise Application -HXXXIXXX-JXXXA:H:Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesReciprocating CompressorsX X X Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesPerformance VisualizationX X X Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesPortable Data CollectorsX X X Number of new licenses, from0 to 100.Example: 0 0 0 0 licenses1 0 0 100 licensesB:XXXNumber of licenses, from 0 to100.Example: 0 0 0 0 licenses1 0 0 100 licensesXXXNumber of licenses, from 0 to100.Example: 0 0 0 0 licenses1 0 0 100 licensesOPC LegacyC:OPC Legacy to A&E UpgradeX X X Number of licenses, from 0 to100.Example: 0 0 0 0 licenses1 0 0 100 licensesD:Not AvailableE:OLEXXXNumber of licenses, from 0 to100.Example: 0 0 0 0 licenses1 0 0 100 licensesSpecifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 8 of 15

F:System 1 Enterprise Connection00None01Custom02Yokogawa PRM 3060/14 DAQ3060/14-AXXX-BXX-CXXA:B:C:Data Acquisition LicensesX X X Number of licenses, from 0 to500, up to 10 per EnterpriseExample: 0 0 0 0 licenses5 0 0 500 licensesMicrosoft SQL Server 2008 R2 with 5 CAL12XXNumber of copies of SQLServer with 5 CAL licenses,from 0 to 25Microsoft SQL Server 2008 R2 with 10 CAL12XXNumber of copies of SQLServer with 10 CAL licenses,from 0 to 253060/15 Data XXXXX-NXXXXXExample: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesF:TDe Steady State Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesG:Portable Data Collector Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesH:Trendmaster Pro Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesI:DCS/Historian Tag LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesJ:Bently Nevada Monitor Static Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesA:TDI Transient Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesK:Dynamic Channel (non-TDI/TDe) LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesB:TDI Steady State Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesL:Electrical/Multilin Device LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesC:TDI Recip Steady State Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesM: Essential Insight Static Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesD:TDI Hydro Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesN: Essential Insight Dynamic Channel LicensesXXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesE:TDe Transient Channel LicensesXXXXXNumber of licenses, from0 to 99998Specifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 9 of 15

3060/16 System X-IXXJXX-KXXXA:B:C:D:E:F:CMMS MAXIMO Links1300None0120 links0250 links03100 links04250 links05500 links06Unlimited links per EnterpriseCMMS SAP PM (pre-Version 4.7) Links00None0120 links0250 links03100 links04250 links05500 links06Unlimited links per EnterpriseCMMS SAP PM (Version 4.7) Links00None0120 links0250 links03100 links04250 links05500 links06Unlimited links per EnterpriseRule Logic Results00None0150 results02150 results03250 results04500 results05Unlimited results perEnterpriseState-Based Analysis Machine Trains00None015 machine trains0210 machine trains0320 machine trains0440 machine trains0580 machine trains06100 machine trains07Unlimited machine trains perEnterpriseSmart NotifierXXXXXNumber of clientaccesses, from 0 tounlimitedExample: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licenses9 9 9 9 9 Unlimited accessesG:Event Relay00NoneH:01Relay software02Relay software and hardwareThe Bearing Expert (REB Database) Licenses16XXXXXNumber of licenses, from0 to 99998Example: 0 0 0 0 0 0 licenses9 9 9 9 8 99998 licensesNote: The Bearing Expert softwareworks with System 1 Configuration andis sold on a per user rather thanconcurrent user basis. A single licensefor The Bearing Expert software may notbe shared or used concurrently ondifferent computers. Each user musthave their own license. Please referto The Bearing Expert LicenseAgreement for further details.I:J:K:GEnyus00NoneGEnyus System 1 Extender & GEnyus software011-4 Throws025-6 Throws037-8 Throws049-10 ThrowsGEnyus System 1 Extender only111-4 Throws125-6 Throws137-8 Throws149-10 ThrowsGEnyus Number of CompressorsXXNumber of compressors,from 0 to 50Example: 0 0 0 licenses5 0 50 licensesRightrax Corrosion & Erosion MonitoringXXXNumber of RightraxSensors, from 0 to 999Example: 0 0 0 0 Rightrax Sensors0 5 0 50 RightraxSensors9 9 9 999 RightraxSensorsNote: Rightrax components have ATEXZone II approvals only.L:AnomAlertXXXNumber of AnomAlertDevices, from 0 to 100Note: You must order 390125-01 for the AESsoftware. Reference Data Sheet 286754-01(motors) or 288496-01 (generators) forinformation regarding ordering the AnomAlerthardware.3060/18 Essential Insight.mesh Management Gateways3060/18-AXXXSpecifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 10 of 15

A: Management GatewaysXXXXNumber of managementgateways, from 0-2000B:3060/36 Decision Support3060/36-AXXA:EditionC:01D:DMS Modbus – 100 TagsDMS Modbus – 500 TagsDMS Modbus – 2500 TagsDMS Modbus – 5000 TagsDMS Modbus – 10000 TagsDMS Modbus – 20000 TagsDMS Modbus – 30000 TagsNote:Ordering this option includes theSystem 1 software DVD and DSMlicense key.E:B:Order Type0102Vibration Data OnlyVibration & Process DataXXNumber of communicationsprocessors, up to 12Example: 1 2 12 comm.processorsLicensingF:3060/90 System 1 Languages3060/90-AXX-BXX-CXX-DXX-EXX-FXX-GXXThe supported Operating System is the English version ofMicrosoft Windows.The Online Help system is available only in English.A:Order Type0102New order (CD, key, binder,Microsoft Excel)Expansion order (key sian3rd LanguageNote:A01 and A02 include DVDs, License Key, Binder,Microsoft Excel, Citrix, and the following manuals: the System 1Software Installation Quick Start Guide, System 1 SoftwareOperations Quick Start Guide and the System 1 Data Manager2000 Upgrade Manual.Notes: No language order is required if the desired System 1language is English.Not AvailableAll2nd Language3060/65 Data Manager 2000 Migration3060/65-AXX-BXXA:01021st LanguageOrder Type001005025050100200300NoneUSB key diskCustomer Type3060/56 DSM Modbus Exporter3060/56-AXXA:0001License TypeStudio DeveloperThe following options are ordered separately from the 3060/00catalog number.9899Core Language CD (CD andbinder)Replacement licenses (key)Update (CD)03G:4th LanguageSpecifications and Ordering InformationPart Number 174590-01Rev. AM (07/12)Page 11 of 15

080910ItalianFinnishSwedishB:000304System 1 Software PlatformNote that all on-line systems require MS SQL Standard, which youmay order through the 3010/11 C option or 3060/00. You willneed one Client Access License (CAL) per client computerC:Any computer with a System 1 client or DAQ software thatconnects to a System 1 database running on SQL Server Standardor Enterprise editions must have one Client Access License (CAL)each.D:3010/11 System 1 Software X-JXXKXX-LXX-MXX-NXX-OXXA:System 1 Workstation/Platform (No Monitor Included)00No workstation/platform01Professional workstation (nomonitor) 202Mid-range server DAQ (tower,no monitor)3, 1103Mid-range server DAQ (rack,rack keyboard/drawer, nomonitor)3, 4, 1104High-performance server DAQ(tower, no monitor)3, 7, 1105High-performance server DAQ(rack, rack keyboard/drawer,no monitor)3, 4, 7, 1106Mid-range server DAQ (rack,rack keyboard only, nomonitor)3, 5, 1107Mid-range server DAQ (rack,nokeyboard/drawer, nomonitor)3, 1108High-performance server DAQrack, rack keyboard only, nomonitor)3, 5, 7, 1109High-performance server DAQ(rack, no keyboard/drawer, nomonitor)3, 7, 111064 bit High-performance, lowprofile server DAQ (rack, rackkeyboard/drawer, nomonitor)3, 4, 7, 11, 171164 bit High-performance, lowprofile server DAQ rack, rackkeyboard only, no monitor)3, 5, 7,11, 171264 bit High-performance, lowprofile server DAQ (rack, nokeyboard/drawer, nomonitor)3, 7, 11, 17MonitorE:F:G:H:I:No monitor22” TFT flat panel monitor24” TFT flat panel monitorMicrosoft SQL Server (for servers only)800None03Standard SQL 2008 R2embedded – 5 CALs1004Standard SQL 2008 R2embedded – 10 CALs10Printer00No printer02220V laser (duplex, parallel,and USB)03110V laser (duplex, parallel,USB, and Ethernet)04220V laser (duplex, parallel,USB, and Ethernet)06220V color laser (USB)07110V color laser (USB, andEth

Electrical/Multilin Devices Provides all static and dynamic data (if dynamic data is applicable) collected from a Multilin device. Supported Multilins include: G60 Generator Management Relay*, 489 Generator Management Relay*, 269Plus Motor Management Relay*, 369 Motor Management Relay*, 469 Motor Management Relay*, M60 Motor Management Relay, Power