Technical InformationSMA SMART HOMECompatibility List for the Sunny Home Manager 2.0ENGLISHSMASmartHomeCompatibilityHM-20-TI-en-11 Version 1.1

Table of ContentsSMA Solar Technology AGTable of Contents1Content and Structure of this Document.32Monitoring .42.1Energy Monitoring.42.1.1Energy Meter.42.1.1.1SMA Energy Meter.4Radio-Controlled Sockets .42.1.2.12.1.2.2Radio-controlled sockets from Edimax.Radio-controlled sockets from AVM .44Temperature Monitoring .42.1.22.22.2.1AVM Temperature Display .4Meter Monitoring and Status Display.5Smart Home Control Equipment .63.1Radio-Controlled Sockets .63.1.13.1.2Radio-controlled sockets from Edimax .Radio-controlled sockets from AVM.66Relay.63.2.162.333.24Moxa Relay.Electrical Loads .74.1Home appliances .74.1.1Dishwasher .74.1.1.14.1.1.2Dishwasher from Bosch .Dishwasher from Siemens.78Clothes dryer .94.1.24.1.2.14.1.2.24.1.3Washing machine . 104.1.3.14.1.3.24.1.4Heat pumps . 15Heating elements from MYPV . 15E-mobility . 154.3.1Charging stations for electric vehicles . 154.3.1.14.3.1.2Charging stations from SMA. 15Charging stations from Mennekes . 16Energy Generators and Storage Systems. 175.15.25.32Heat Pumps with SG-Ready Interface.Heat pumps from AEG Haustechnik.Heat pumps from Stiebel Eltron .Heat pumps from Tecalor .Vaillant Heat Pumps.Heating elements . 154.2.2.15Washer-dryer from Bosch. 11Washer-dryer from Siemens . 11Space- and Water Heating. 114.2.14.3Washing machine from Bosch . 10Washing machine from Siemens . 10Washer-dryer. 114.1.4.14.1.4.24.2Clothes dryer from Bosch .9Clothes dryer from Siemens . 10SMA PV Inverters. 17SMA Battery Inverters . 17SMA Hybrid Inverters. 18SMASmartHomeCompatibilityHM-20-TI-en-11Technical Information

1 Content and Structure of this DocumentSMA Solar Technology AG1Content and Structure of this DocumentThis document provides an overview of products that are compatible with the use of Sunny Home Manager 2.0(HM-20): Monitoring products Load control products Products for energy generation and storageMonitoring productsThe Sunny Home Manager supports simple monitoring of different values without using these values for direct control.This information is visualized in Sunny Portal.Load control productsAs an energy manager for systems equipped with PV systems, the Sunny Home Manager offers solutions for loadcontrol of devices from different manufacturers. Loads can include, for example, appliances for the household, heatingand hot water preparation as well as e-mobility.In principle there are the following types of load control for this: Indirect control, e.g. via a radio-controlled socket or a relayRadio-controlled sockets and relays enable communication with a wide range of devices that cannot be controlledby the Sunny Home Manager via a direct data connection. Direct control, e.g. via the an EEBus or SEMP interfaceLoads with a direct data connection to the Sunny Home Manager can be included in energy management withoutdetailed configuration. The Sunny Home Manager automatically exchanges all load-relevant information directlywith the appliances in the household and includes the load optimally in the planning process. Direct control via the SG-Ready interfaceWhen connecting a load with electronic control input (e.g. SG Ready or trigger input), the control input signalswill be supplied by a relay with a floating switching output. The load is hard-wired to the power supply andalways has power. The control input is activated via the relay of the actuator and the load starts.Products for energy generation and storageThe Sunny Home Manager receives the data of the energy generated by the PV system directly from the connectedSMA inverters. If third-party inverters or other generators are also installed in the PV system, the Sunny Home Managertakes over the measurement data for the generated energy from an intermediate energy meter.Battery inverters can temporarily store the energy generated by the PV system and make it available when needed.The Sunny Home Manager makes it possible to optimally schedule and use this temporarily stored energy.Additional InformationSMA offers the option to use the protocol interface SEMP under ormation on the EEBus communication interface and the EEBus protocol you find under https://www.eebus.org/Technical 3

2 Monitoring2SMA Solar Technology AGMonitoring2.1Energy MonitoringIn energy monitoring, the entire energy flows in the household are recorded. Both the amount of energy generated bythe PV system and the energy consumption of connected loads can be measured.2.1.1Energy Meter2.1.1.1SMA Energy MeterThe Sunny Home Manager supports the following energy meter:ProductFirmware versionSMA Energy Meter 10from 1.0.4.RSMA Energy Meter 20from 2.0.4.R2.1.2Radio-Controlled SocketsThe measuring function of the radio-controlled sockets can be used to record the energy consumption of individualelectrically connected loads, e.g. household appliances.2.1.2.1Radio-controlled sockets from EdimaxFor the compatibility of the Wi-Fi radio-controlled sockets from Edimax with the Sunny Home Manager (from version2.2), the firmware versions of the devices must be taken into account:ProductFirmware versionSP-2101Wup to 2.08SP-2101W V2from 1.00SP-2101W V3from 4.042.1.2.2Radio-controlled sockets from AVMThe Sunny Home Manager (from version 2.3) supports AVM radio-controlled sockets in combination with a FRITZ!Boxwith DECT function. The FritzOS version of the FRITZ!Box must be taken into account:ProductFritzOS versionFRITZ!DECT 200from 5.5FRITZ!DECT 210from 6.02.22.2.1Temperature MonitoringAVM Temperature DisplayThe Sunny Home Manager (from version 2.5) supports the display of the device temperature in combination with aFRITZ!Box with DECT function. The FritzOS version of the FRITZ!Box must be taken into account:ProductFritzOS versionRadio-controlled socket FRITZ!DECT 200from 5.5Radio-controlled socket FRITZ!DECT 210from 6.0Radiator regulators FRITZ!DECT 301from al Information

2 MonitoringSMA Solar Technology AG2.3Meter Monitoring and Status DisplayThe current status of the grid supply and the grid feed-in can be displayed via an LED lamp and thus support you inyour load control.The Sunny Home Manager (from version 2.7) supports AVM LED lamps in combination with a FRITZ!Box with DECTfunction. The FritzOS version of the FRITZ!Box must be taken into account:ProductFritzOS versionLED lamp FRITZ!DECT 500from 7.2Technical 5

3 Smart Home Control Equipment3SMA Solar Technology AGSmart Home Control EquipmentVia a compatible radio-controlled socket or a compatible relay, a variety of devices that cannot communicate directlywith the Sunny Home Manager can be connected to and switched by the Sunny Home Manager.3.13.1.1Radio-Controlled SocketsRadio-controlled sockets from EdimaxFor the compatibility of the Wi-Fi radio-controlled sockets from Edimax with the Sunny Home Manager 2.0 (from version 2.2), the firmware versions of the devices must be taken into account:ProductFirmware versionSP-2101Wup to 2.08SP-2101W V2from 1.00SP-2101W V3from 4.043.1.2Radio-controlled sockets from AVMThe Sunny Home Manager (from version 2.3) supports AVM radio-controlled sockets in combination with a FRITZ!Boxwith DECT function. The FritzOS version of the FRITZ!Box must be taken into account:ProductFritzOS versionFRITZ!DECT 200from 5.5FRITZ!DECT 210from 6.03.23.2.1RelayMoxa RelayThe Sunny Home Manager (from version 2.5) supports the following relays from Moxa:ProductCommunication standardMoxa ioLogik E 1214*Modbus* Currently, only relay output 1 of the possible 6 relay outputs of the Moxa 1214 can be used, e.g. for SG Ready devices such as Technical Information

4 Electrical LoadsSMA Solar Technology AG4Electrical LoadsThis list contains a selection of electrical loads which, according to the manufacturers, can communicate directly orindirectly with the Sunny Home Manager and has been compiled according to the manufacturers' specifications.Not all devices have been tested by SMA in conjunction with the Sunny Home Manager.4.14.1.14.1.1.1Home appliancesDishwasherDishwasher from BoschThe following dishwashers from Bosch are equipped with a communication module that supports connection to theSunny Home h Series EGermanyEEBusSBA88TD36EGermanyEEBusBosch Series 8Technical 7

4 Electrical Loads4.1.1.2SMA Solar Technology AGDishwasher from SiemensThe following dishwashers from Siemens are equipped with a communication module that supports connection to theSunny Home ens atibilityHM-20-TI-en-11Technical Information

4 Electrical LoadsSMA Solar Technology AGSeriesProductSoldCommunicationstandardSiemens X878D26PEEuropeEEBus4.1.24.1.2.1Clothes dryerClothes dryer from BoschThe following dryers from Bosch are equipped with a communication module that supports connection to theSunny Home h Home usWTX87K90GermanyEEBusWTX87K80GermanyEEBusBosch Series 8Technical 9

4 Electrical Loads4.1.2.2SMA Solar Technology AGClothes dryer from SiemensThe following dryers from Siemens are equipped with a communication module that supports connection to theSunny Home ens avantgardeWT47X940EUGermany, AustriaEEBusSiemens iQ800WT7YH701Germany, AustriaEEBus4.1.34.1.3.1Washing machineWashing machine from BoschThe following washing machines from Bosch are equipped with a communication module that supports connection tothe Sunny Home h Home usWAV28K40GermanyEEBusWAV28M40GermanyEEBusBosch Series 84.1.3.2Washing machine from SiemensThe following washing machines from Siemens are equipped with a communication module that supports connectionto the Sunny Home ens avantgardeWM14U840EUGermany, AustriaEEBusWM14U940EUGermany, AustriaEEBusWM14VL40Germany, AustriaEEBusWM14VM40Germany, AustriaEEBusWM14VMG1Germany, AustriaEEBusSiemens nical Information

4 Electrical LoadsSMA Solar Technology AGSeriesProductSoldCommunicationstandardSiemens iQ800WM14VG40Germany, AustriaEEBusWM16XE90Germany, AustriaEEBusWM16XF90Germany, AustriaEEBusWM4YH748Germany, AustriaEEBusWM4YH749Germany, AustriaEEBusWM4YH7W0Germany, AustriaEEBusWM6YH842Germany, AustriaEEBusWM6YH891Germany, AustriaEEBus4.1.44.1.4.1Washer-dryerWasher-dryer from BoschThe following washing machines with dryer function from Bosch are equipped with a communication module thatsupports connection to the Sunny Home h Series 6WDU28512Germany, Austria, LuxembourgEEBusWDU28592Germany, Austria, LuxembourgEEBus4.1.4.2Washer-dryer from SiemensThe following washing machines with dryer function from Siemens are equipped with a communication module thatsupports connection to the Sunny Home ens iQ500WD14U512Germany, Austria, LuxembourgEEBusWD14U592Germany, Austria, LuxembourgEEBus4.24.2.1Space- and Water HeatingHeat pumpsHeat pumps are divided into three different types. This has an influence on the type of connection to theSunny Home Manager.ON/OFF heat pumps are heat pumps whose compressor runs with a constant speed during operation and draws aconstant level of power. There are three control options for ON/OFF heat pumps: Control via radio-controlled sockets Direct control via the SG-Ready interface of the heat pump Direct control via a communication standard (SEMP or EEBus)Technical 11

4 Electrical LoadsSMA Solar Technology AGInverter heat pumps are heat pumps where the rotating speed of the compressor during operation is controlled in sucha way that, in accordance with the available temperature profile, an optimum performance level is achieved. The heatpump control is able to adjust the energy consumption according to the situation. There are two control options forinverter heat pumps: Direct control via the SG-Ready interface of the heat pump Direct control via a communication standard (SEMP or EEBus)Integral systems as well as air-to-water heat pumps and brine-to-water heat pumps perform the function of ventilation inaddition to space- and water heating. They can be controlled by the Sunny Home Manager if they communicate via acommunication standard.According to the manufacturer, the heat pumps listed below can be controlled directly by the Sunny Home Manager.4.2.1.1Heat Pumps with SG-Ready InterfaceTypeProductPart numberCommunicationstandardRelayMoxa ioLogik E 1214EIO-E1214ModbusModels that have an SG Ready interface can be found in the SG Ready database: /sg-ready-datenbank/4.2.1.2Heat pumps from AEG N/OFF heat pumpWPT220 ELRadio-controlledsocket300 ELRadio-controlledsocket300 EL ityHM-20-TI-en-11Technical Information

4 Electrical LoadsSMA Solar Technology AG4.2.1.3Heat pumps from Stiebel EltronThe following heat pumps are able to use the SEMP data protocol in conjunction with the Stiebel Eltron ISG web andthe EMI software module or can be operated with the Sunny Home Manager in conjunction with a ionstandardON/OFF heatpumpsStiebel WWK220 electronicSMA radio-controlledsocket300 electronicSMA radio-controlledsocket300 electronic SOLSMA radio-controlledsocket221 electronicSMA radio-controlledsocket301 electronicSMA radio-controlledsocket301 electronic SOLSMA radio-controlledsocket303/403 (Integral/SOL) from manufacture date 08/2008SEMP303/404 (SOL)SEMP304/404 TrendSEMP504SEMP10 I, IK, ACSEMP13/20 A basicSEMP13-23 E / coolSEMP34/47/57SEMP15/25 A(C)(S)SEMP20-66 / HTSEMP04-16 / coolSEMP04-13 / coolSEMPIntegral systemsAir-to-water heatpumpsBrine-to-water heatpumpsStiebel LWZStiebel WPLStiebel WPFStiebel WPCTechnical 13

4 Electrical Loads4.2.1.4SMA Solar Technology AGHeat pumps from TecalorThe following heat pumps are able to use the SEMP data protocol in conjunction with the Tecalor ISG web and theEMI software module or can be operated with the Sunny Home Manager in conjunction with a radio-controlled F heatpumpsTecalor TTA220 electronicSMA radio-controlledsocket300 electronicSMA radio-controlledsocket300 electronic SOLSMA radio-controlledsocket221 electronicSMA radio-controlledsocket301 electronicSMA radio-controlledsocket301 electronic SOLSMA radio-controlledsocket303/403 (Integral/SOL) from manufacture date 08/2008SEMP304/404 (SOL)SEMP304/404 TrendSEMP504SEMP10 I, IK, ACSEMP13/20 A basicSEMP13-23 E / coolSEMP34/47/57SEMP15/25 A(C)(S)SEMP10-16 MSEMP20-66 / HTSEMP04-16 / coolSEMP04-13 / coolSEMPIntegral systemsAir-to-water heatpumpsBrine-to-water heatpumpsTecalor THZTecalor TTLTecalor TTFTecalor cal Information

4 Electrical LoadsSMA Solar Technology AG4.2.1.5Vaillant Heat PumpsThe Vaillant heat pumps have to be connected to the local network (router) via a Vaillant communication unit (VR 920or VR 921). The Sunny Home Manager from firmware version 2.2 supports the following Vaillant heat pumps (as ofJanuary 2021):TypeSeriesProductSoldAir-to-water heatpumpsaroTHERMVWL /2VWL /3Germany, Austria, Belgium, DenEEBusmark, Finland, Luxembourg, NetherEEBuslands, Sweden, SwitzerlandVWL /5EEBusGermany, Austria, Belgium, DenEEBusmark, Finland, Luxembourg, NetherEEBuslands, Sweden, SwitzerlandAir-to-water heatpumpsaroTHERM SplitVWL /5aroTHERM plusVWL /6Heat pumpsflexoCOMPACTexclusiveVWL /4flexoTHERM exclusiveVWL /4recoCOMPACTexclusiveVWL /5versoTHERMplusVWL /5Air-to-water heatpumps installed indoors4.2.2CommunicationstandardGermany, Austria, Belgium, DenEEBusmark, Finland, Luxembourg, Netherlands, Sweden, SwitzerlandEEBusGermany, Austria, Belgium, DenEEBusmark, Finland, Luxembourg, Netherlands, Sweden, SwitzerlandEEBusHeating elements4.2.2.1Heating elements from MYPVNot compatible in case of setting a direct meter communication when configuring the Sunny Home Manager.ProductCommunication standardAC ELWA-ESEMPAC ThorSEMPAC Thor 9sSEMP4.34.3.14.3.1.1E-mobilityCharging stations for electric vehiclesCharging stations from SMAThe Sunny Home Manager (from version 2.8) supports a maximum of 3 SMA EV Charger per PV system.SeriesProductCommunication standardSMA EV ChargerEVC7.4-1AC-10*SEMPEVC22-3AC-10*SEMP* From version 1.2.x.RTechnical 15

4 Electrical Loads4.3.1.2SMA Solar Technology AGCharging stations from MennekesSeriesProductCommunication standardMennekes AMTRONXtraSEMPPremiumSEMPProfessional*SEMPCharge Control*SEMP* From version ical Information

5 Energy Generators and Storage SystemsSMA Solar Technology AG5Energy Generators and Storage Systems5.1SMA PV InvertersDevice typeSunny BoyFrom inverterfirmware versionSB 3000TL-21 / SB 3600TL-21 / SB 4000TL-21 / SB 5000TL-21 / SB6000TL-212.00.00.R*SB1.5-1VL-40 / SB2.0-1VL-40 / SB2.5-1VL-402.03.01.RSB3.0-1AV-40 / SB3.6-1AV-40 /SB4.0-1AV-40 /SB5.0-1AV-401.02.18.RSB3.0-1AV-41 / SB3.6-1AV-41 / SB4.0-1AV-41 / SB5.0-1AV-41 /SB6.0-1AV-413.10.18.RSB 2500TLST-21 / SB 3000TLST-212.00.27.R*Sunny Tripower STP3.0-3AV-40 / STP4.0-3AV-40 / STP5.0-3AV-40 / STP6.0-3AV-40 /STP8.0-3AV-40 / STP10.0-3AV-4002.11.09.RSTP 50-4001.01.19.RSTP 8000TL-10 / STP 10000TL-10 / STP 12000TL-10 / STP15000TL-10 / STP 17000TL-102.33.02.R*STP 5000TL-20/STP 6000TL-20/STP 7000TL-20/STP 8000TL-20/STP 9000TL-20/STP 10000TL-20/STP 12000TL-202.00.15.RSTP 15000TLEE-10 / STP 20000TLEE-102.10.20.RSTP 15000TL-30 / STP 20000TL-30 / STP 25000TL-3002.80.04.R* This firmware version is the minimum requirement for the function Limiting of the active power feed-in.For inverters without an integrated Speedwire interface, the Speedwire/Webconnect data module SWDM-10 mayalso be required.5.2SMA Battery InvertersDevice typeFrom inverterfirmware versionSunny Boy Stor- SBS2.5-1VL-10ageSBS3.7-10 / SBS5.0-10 / SBS6.0-1002.02.01.RSunny IslandSI 6.0H- / SI 8.0H01.00.xx.RSI3.0M-11 / SI4.4M-111.00.00.R01.00.63.RSI3.0M-11 / SI4.4M-11 / SI6.0H-11 / SI8.0-11With SMA Speedwire data module Sunny Island SWDMSI-NR10SI4.4M-12 / SI6.0H-12 / SI8.0H-1201.00.xx.RSI4.4M-13 / SI6.0H-13 / SI8.0H-133.0x.xx.RTechnical 17

5 Energy Generators and Storage Systems5.3SMA Hybrid InvertersDevice typeSunny BoyFrom inverterfirmware versionSB 3600SE-10 / SB 5000SE-10Sunny Tripower STP5.0-3SE-40 / STP6.0-3SE-40 / STP8.0-3SE-40 /STP10.0-3SE-4018SMA Solar Technology .00.08.RTechnical Information

www.SMA-Solar.com

by the Sunny Home Manager via a direct data connection. Direct control, e.g. via the an EEBus or SEMP interface Loads with a direct data connection to the Sunny Home Manager can be included in energy management without detailed configuration. The Sunny Home Manager automatically exchanges all load-relevant information directly