Technical Data Guide707 27 26Fluid-Applied MembraneAir BarriersMasterSeal AWB 660 Vapor permeable air/water-resistive barrierFORMERLY ENERSHIELD HPDESCRIPTIONPACKAGINGMASTERSEAL AWB 660 5-gallon pail (18.9 L) pailACCESSORIESMasterSeal AWB 971 FIB: 4": 4" x 180 ft (101.5 mm x 54.8 m) roll 6": 6" x 180 ft (152.4 mm x 54.8 m) roll 9": 9" x 180 ft (228.5 mm x 54.8 m) roll 56 MasterSeal AWB 975 FIB pieces perdispenser boxMasterSeal AWB 970 FIB 4: 4" x 100'(10.2 cm x 30.5 m) rolls - 9 rolls per cartonMasterSeal AWB 970 FIB 9: 9"x 100'(22.9 cm x 30.5 m) rolls - 4 per cartonMasterSeal AWB 950 P 19 liter (5 gallon)pails, 3.8 liter (1 gallon) bottles with4 bottles per cartonMasterSeal AWB 960 AC 0.95L (1 quart)plastic bottles with 8 bottles per cartonMasterSeal AWB 900 20 oz. propak with20 propaks per cartonSHELF LIFEMasterSeal AWB 660 has 2 years shelf lifewhen properly storedSTORAGEStore in unopened containers in clean, dryplace protected liquid system componentsfrom freezing. Store at no less than 4 C(40 F) and below 49 C (120 F). Protectfrom extreme heat and direct sunlight. Donot stack pallets.VOC CONTENT17 g/l, or 0.14 lbs/gal less water andexempt solvents per ASTM D2369 (basedin part on EPA method 24).SOLIDS74%COLORGrayMasterSeal AWB 660 is a one-component, fluid-applied vapor permeable air/water-resistivebarrier. This waterproof, resilient coating may be spray-, roller-, or brush-, or trowel- applied directlyto approved above grade wall substrates. It provides excellent secondary moisture protection behindmost wall claddings including brick, siding and metal panels.APPLICATION/APPROVED SUBSTRATEFor use over the following exterior wallsubstrates:Poured concrete/unit masonry, pouredconcrete/unit masonry treated withMasterSeal AWB 600 FL , ASTM C1177type sheathings, including DensGlass or DensElementexterior sheathing, eXP sheathing, GlasRoc sheathing, Securock glass-mat sheathing, Weather Defense Platinum sheathing, GreenGlass sheathing,PermaBase cement-board by NationalGypsum and other cement-boards (ASTMC1325 Type A Exterior), untreated ExposureI or exterior plywood sheathing (grade C-D orbetter), untreated Exposure I OSB, gypsumsheathing (ASTM C79/ASTM C1396), Fireresistive sheathing such as MagTec, LPFlameBlockDo not use MasterSeal AWB 660 forbelow-grade applications or on surfacessubject to water immersionCoverageSubstrate ASTM C1177 Type Sheathing450 ft2 (41 m2) per pailCement Board500 ft2 (46 m2) per pail Plywood*265 ft2 (24 m2) per pail Oriented Strand Board (OSB)265 ft2 (24 m2) per pail Concrete Masonry Units (CMU)*Standard Weight 265 ft2 (24 m2) per pailMedium Weight 180 ft2 (17 m2) per pailLight Weight 125 ft2 (12 m2) per pail Poured Concrete*46 m2 (500 ft2) per pail Concrete / Masonry with MasterSeal AWB 600 FL46 m2 (500 ft2) per pail Embed Sheathing Fabric4" Sheathing Fabric: 630 ft (192 m) per pail6" Sheathing Fabric: 420 ft (128 m) per pail9" Sheathing Fabric: 280 ft (85 m) per pail *Roll or spray / backroll for optimum coveragerate. Other application methods may provideless coverage. Actual results may varydepending on surface porosity, roughness,moisture uptake or other factors. ote:NMasterSeal AWB 971 FIB saturated withMasterSeal AWB 660, when applied permanufacturer instructions, self gauges to a30-40 mil thickness.A brand ofwww.master-builders-solutions.com/en-us

Technical Data GuideMasterSeal AWB 660MasterSeal AWB 660 complies with the air barrier requirements of the Massachusetts State Energy CodeFeaturesBenefitsICC ESR-3209 Evaluation ReportConfirms compliance with IBC, IRC, and IECL requirementsABAA evaluatedApproved for projects requiring ABAA specifications and quality assurance 1% of allowable air leakage per ASTM E2357 Air Leakage of Buildingassemblies testEasily meets air tightness requirements defined by ASHRAE 189.1, ASHRAE 90.1and ABAAMeets ASTM D1970 nail sealability requirements with and without sheathing fabricSelf sealing performanceOne component, low-VOC formulationEasy to apply, meets VOC requirements in all 50 statesNonflammable as appliedWorkplace safetyMineral oil and plasticizer freeWill not dry out or crack due to loss of oil / plasticizer over timeWater basedCleans up with water; solvents and citrus based cleaners not requiredTough, abrasion resistantRugged membrane resists damage after installationApproved for use with MASTER BUILDERS SOLUTIONS EIFS and stucco systemsFull system warranty, seamless membrane for buildings with multiple claddingsLow temperature performance with MasterSeal AWB 960 ACExtends minimum application temperature to -4 C (25 F)180 day outdoor exposure ratingFlexible construction schedulingTEST DATAPROPERTYRESULTSTEST METHODAir Leakage of Air Barrier Assemblies0.0007 l/s.m2 (0.0001 cfm/ft2) @ 75 Pa (1.57 psf) positive/post conditioning0.0014 l/s.m2 (0.0003 cfm/ft2) @ 75 Pa (1.57 psf) negative/post conditioningASTM E 2357Air Permeance of Building Materials0.0049 l/s.m2 @ 75 Pa (0.00098 cfm/ft2 @ 1.57 psf)(.00098 cfm/ft(2) @ 1.57 psfASTM E 2178Rate of Air Leakage0.0185 l/s·m2 @ 75 Pa (0.0037 cfm/ft2 @ 1.57 psf)ASTM E 283Water Vapor Transmission18 Perms (grains/Hr. in Hg. ft2) @ 10 mils wet film thickness14 Perms (grains/Hr. in Hg. ft 2) @ 20 mils wet film thicknessASTM E 96 Method BPull-Off Strength of CoatingsPass - Min. 110 kPa (15.9 psi) or substrate failure (Tested over exterior gypsumsheathing, ASTM C1177 glass-mat sheathing, cement board, OSB, plywood; pvcand galvanized flashing)ASTM D 4541Nail Sealability(without Sheathing Fabric)Pass - No water penetration at galvanized roofing nail penetration under 127 mm (5")head of water after 3 days at 4 C (40 F)ASTM D 1970Compound Stability(Elevated Temperature)No flowing, dripping or drop formation up to 177 C (350 F)ASTM D 5147 Section 15Surface BurningClass A Flame Spread ( 25)Class A Smoke Developed Spread ( 450)ASTM E 84Radiant Heat Multi-Story TestsPassed using numerous wall assemblies. Engineering analyses available upon request.NFPA 285Fire ResistanceWill not add or detract from the rating of a fire resistive wall assemblyASTM E 119/UL 263Drainage Efficiency99%ASTM E 2273

Master Builders C-ES AC 212: Acceptance Criteria for Water-Resistive Coatings used as Water-Resistive Barriers over Exterior SheathingPROPERTYRESULTSTEST METHODNo cracking at joints or interface of flashingNo cracking at joints or interface of flashingNo cracking at joints or interface of flashingNo water penetration after 90 min @ 299 Pa (6.24 psf) Tested over OSBand gypsum sheathingASTM E 1233 Procedure AASTM E 72ICC-ES AC 212ASTM E 331No cracking or bond failure to substrateNo cracking or bond failure to substrateNo water penetration at 55 cm (21.7") water column for 5 hoursICC-ES AC 212ICC-ES AC 212AATCC 127-1985Freeze-ThawNo sign of deleterious effects after 10 cycles (Tested over exterior gypsum sheathing,ASTM C1177 glass-mat sheathing, cement board, OSB, plywood)ASTM E 2485 (Method B)Water ResistanceNo sign of deleterious effects after 14 day exposure (Tested over exterior gypsumsheathing, ASTM C1177 glass-mat sheathing, cement board, OSB, plywood)ASTM D 2247Tensile Bond 103 kPa (15 psi) Tested over exterior gypsum sheathing, ASTM C1177 glassmatsheathing, cement board, OSB, plywood, CMU; pvc and galvanized flashingASTM C 297Tensile Bond(before & after freeze-thaw) 103 kPa (15 psi) avg; no failure of the lamina after 10 cycles freeze-thaw(Tested over various substrates)ASTM C 297Sequential Testing1. Structural2. Racking3. Restrained Environmental Conditioning4. Water PenetrationSequential Testing - Weathering1. UV Light Exposure2. Accelerated Aging3. Hydrostatic PressureICC-ES AC 148: Acceptance Criteria for Flexible Flashing MaterialsPROPERTYRESULTSTEST METHODNo No cracking or bond failure to substrateNo cracking or bond failure to substrateNo water penetration at 55 cm (21.7") water column for 5 hoursICC-ES AC 148ICC-ES AC 148AATCC 127-1985ASTM D3330 Method FAfter UV ExposureAfter Accelerated AgingAfter Elevated Temperature ExposureAfter Water ImmersionTested over ASTM C1177 glass-mat sheathing, OSB, plywood, pvc and uncoatedaluminumPassPassPassPassNail Sealability after Thermal CyclingPassASTM D 1970 (Modified),AAMA 711Tensile Strength after UV ExposureAll samples meet the minimum requirement of 3.5N/mm (20 lbs/in)ASTM D 5034, AAMA 711Cold Temperature PliabilityNo cracking after bending around a 25 mm (1") mandrel after 2 hour exposure to-18 C (0 F)ASTM D 1970, AAMA 711Resistance to PeelingNo signs of distress or failure after 24 hours of exposure at room temperature,50 C (122 F), 65 C (149 F), 80 C (176 F)AAMA 711Sequential Testing – Weathering1. UV Light Exposure2. Accelerated Aging3. Hydrostatic Pressure TestPeal AdhesionASTM D3330 Method FASTM D3330 Method FASTM D3330 Method FASTM D3330 Method F

Technical Data GuideMasterSeal AWB 660MIXING1. Use directly from original packaging or prepare in a container that isclean and free of foreign substances. Do not use a container whichhas contained or been cleaned with a petroleum-based product.2. Mix MasterSeal AWB 660 with a clean, rust-free paddle and drilluntil thoroughly blended. Dilution of MasterSeal AWB 660 is notrecommended.3. Additives other than MasterSeal AWB 960 AC are not permitted.4. Close container when not in use.5. Clean tools and equipment with water immediately after use. Driedmaterial can only be removed mechanically.APPLICATIONJOB CONDITIONSTo apply MasterSeal AWB 660 at ambient temperatures below4 C (40 F) but greater than -4 C (25 F), thoroughly blend 1 fullquart of MasterSeal AWB 960 AC with one full 5- gallon pail of applyMasterSeal AWB 660. When using MasterSeal AWB 960 AC,extended drying time can be expected. Do not apply MasterSeal AWB 660 to frozen or frost-laden substrates.Do not apply MasterSeal AWB 660 in ambient temperaturesbelow 4 C (40 F) or onto substrates below 4 C (40 F) unlessMasterSeal AWB 960 AC is used.Walls shall be capped to prevent moisture and precipitation fromentering wall during construction.Limit the weather exposure of apply MasterSeal AWB 660 to amaximum of 180 days.SURFACE PREPARATIONSubstrate shall be dry, clean, sound and free of release agents,paint or other residue or coatings. Verify substrate is flat, free offins or planar irregularities greater than 6.4 mm in 3 m (1/4” in 10’).Unsatisfactory conditions shall be reported to the general contractorand corrected before application of apply MasterSeal AWB 660.EQUIPMENTUse a 20 mm (3/4”) nap roller or paint brush. If spraying, refer toSpray Application of apply MasterSeal AWB 660 / MasterSeal AWB660 I/ MasterSeal AWB 665/ MasterSeal AWB 600 FL technicalbulletin for spray application equipment and application instructions.Note: If using roller application, it is necessary to pre-wet thesynthetic roller pad with water and spin out the excess water. Thepre-wetting only needs to be done once at the start of application.Framed Construction technical bulletin or apply MasterSeal AWBApplication Guidelines for Flashing Rough Openings on Concreteand Masonry Construction technical bulletin.3. A. I mmediately place and center MasterSeal AWB 971 FIB overwet MasterSeal AWB 660 at knot holes and check cracks thatmay exist in plywood or OSB. Completely saturate MasterSeal AWB 971 FIB with MasterSeal AWB 660. B. I f using roller, brush, or trowel application, allow to dry to thetouch before applying MasterSeal AWB 660 to entire wallsurface. If spraying, “wet on wet” application is acceptable.4. Refer to Spray Application of MasterSeal AWB 660 / MasterSeal AWB 660 I/ MasterSeal AWB 665/ MasterSeal AWB 600 FLtechnical bulletin for spray application equipment and applicationinstructions.5. A. Apply MasterSeal AWB 660 to DensGlass exterior sheathing,eXP sheathing, GlasRoc sheathing, Securock glass-matsheathing, Weather Defense Platinum sheathing, GreenGlass sheathing, PermaBaseTM cement-board by National Gypsumand other cementboards (ASTM C1325 Type A Exterior), gypsumsheathing (ASTM C79/ASTM C1396) and concrete with a 20 mm(3/4”) nap roller, stainless steel trowel, brush or spray gun to aconsistent, minimum 10 wet mil thickness that is free of voidsand pin holes. A fully loaded roller pad is required to obtain aconsistent, minimum 10 wet mil thickness.B. Apply MasterSeal AWB 660 at a minimum of 10-mil wet filmthickness on concrete/masonry substrates that have received afully cured application of MasterSeal AWB 600 FL Block Filler.For concrete/masonry substrates that have not been treatedwith MasterSeal AWB 600 FL Block Filler, two (2) minimum10-mil applications of MasterSeal AWB 660 are required. Note:Lightweight CMU or other CMU with high porosity may requireadditional MasterSeal AWB 660 to produce an acceptable result.C. Apply MasterSeal AWB 660 to plywood and OSB sheathingusing a 20 mm (3/4”) nap roller or spray to a consistent,minimum 10-mil wet film thickness. Visually inspect to determinewhether the sheathing surface is fully coated and free of voidsand pinholes. Repair as re required to produce a continuouscoating. Apply a second 10 ml wet film coat of MasterSeal AWB660 to produce a total wet film thickness of 20-mils.D. Visually inspect the MasterSeal AWB 660 for voids, pinholes,surface deficiencies, etc. Repair deficiencies and areas that arenot intact. Apply additional MasterSeal AWB 660 as necessarysuch that MasterSeal AWB 660 is free of voids, pinholes, etc.All sheathing joints, terminations, inside and outside cornersmust be reinforced with 4” or 9” MasterSeal AWB 971 FIB orMasterSeal AWB 970 FIB 4 or 9.PROCEDURE1. Substrate shall be of a type acceptable by Master BuildersSolutions and shall be installed per substrate manufacturer’sinstructions and local code requirements.2. Apply MasterSeal AWB 660 and/or apply MasterSeal AWB 900Liquid Flashing Membrane to fasteners, sheathing joints, andrough openings as outlined in apply MasterSeal AWB ApplicationGuidelines for Joint Treatment and Flashing Rough Openings onDrying TimeAllow to dry completely, typically 2 to 4 hours at 25 C (77 F) and50% relative humidity. Protect from rain and from temperatures lessthan 4 C (40 F) until dry.

Master Builders CHNICAL SUPPORTConsult the Master Builders SolutionsConstruction Systems Technical ServicesDepartment for specific recommendationsconcerning all other applications. Consultthe Master Builders website, www.masterbuilders-solutions.com/en-us, for additionalinformation about products and systems andfor updated literature.HEALTH AND SAFETYFollow good safety and industrial hygienepractices during handling and installingproducts and systems. Take necessaryprecautions and wear the appropriate personalprotective equipment as needed. Read SafetyData Sheet (SDS) and related literature on thisproduct before specification and/or installation.Solids74% solidsVOC Content17 g/l, or 0.14 lbs/gal less water and exemptsolvents per ASTM D2369 (based in part onEPA method 24)IN CASE OF EMERGENCY: Call CHEMTEL 1 (800) 255-3924 or if outside the US orCanada, 1 (813) 248-0585.Master Builders Solutions Construction Systems US, LLC MBCC Group, Form No.14000239 rev 04/2021 registered trademark of a MBCC Group member in many countries of the worldLIMITED WARRANTY NOTICEMaster Builders Solutions ConstructionSystems US, LLC (“Master Builders”) warrantsthis product to be free from manufacturingdefects and to meet the technical propertieson the current Technical Data Guide, if usedas directed within shelf life. Satisfactoryresults depend not only on quality productsbut also upon many factors beyond ourcontrol. MASTER BUILDERS MAKES NOOTHER WARRANTY OR GUARANTEE,EXPRESS OR IMPLIED, INCLUDINGWARRANTIES OF MERCHANTABILITY ORFITNESS FOR A PARTICULAR PURPOSEWITH RESPECT TO ITS PRODUCTS. Thesole and exclusive remedy of Purchaser forany claim concerning this product, includingbut not limited to, claims alleging breachof warranty, negligence, strict liability orotherwise, is shipment to purchaser ofproduct equal to the amount of product thatfails to meet this warranty or refund of theoriginal purchase price of product that failsto meet this warranty, at the sole option ofMaster Builders. Any claims concerning thisproduct must be received in writing within one(1) year from the date of shipment and anyclaims not presented within that period arewaived by Purchaser. MASTER BUILDERSWILL NOT BE RESPONSIBLE FOR ANYSPECIAL, INCIDENTAL, CONSEQUENTIAL(INCLUDING LOST PROFITS) OR PUNITIVEDAMAGES OF ANY KIND.889 Valley Park Drive, Shakopee, MN ser must determine the suitability of theproducts for the intended use and assumesall risks and liabilities in connection therewith.This information and all further technicaladvice are based on Master Builders’ presentknowledge and experience. However, MasterBuilders assumes no liability for providing suchinformation and advice including the extent towhich such information and advice may relateto existing third party intellectual propertyrights, especially patent rights, nor shall anylegal relationship be created by or arise fromthe provision of such information and advice.Master Builders reserves the right to make anychanges according to technological progressor further developments. The Purchaserof the Product(s) must test the product(s)for suitability for the intended applicationand purpose before proceeding with a fullapplication of the product(s). Performance ofthe product described herein should be verifiedby testing and carried out by qualified experts.FOR PROFESSIONAL USE ONLY. NOT FORSALE TO OR USE BY THE GENERAL PUBLIC.Customer Service 1 (800) 433-9517Technical Service 1 (800) 243-6739

Water based Cleans up with water; solvents and citrus based cleaners not required . positive/post conditioning 0.0014 l/s.m 2 (0.0003 cfm/ft) @ 75 Pa (1.57 psf) negative/post conditioning ASTM E 2357 Air Permeance of Building Materials 0.0049 l/s.m 2 @ 75 Pa (0.00098 cfm/ft @ 1.57 psf) . Restrained Environmental Conditioning 4. Water .