Product Guide2015Oil-fired andsolar thermalheating and hot water solutionsNEWGreenstarComfortcontrols1

The complete WorcesterGreenstar oil-firedproduct rangeOur market-leading Greenstar oil-fired condensingboilers are part of the Worcester total systemsolutions package. The Heatslave and Danesmoorboiler series combine both Worcester’s renownedquality and reliability, with improved installationease, innovative servicing features, and enhancedenergy efficiency. For many, Worcester is theinstaller’s choice, and with state-of the- art trainingfacilities as well as award-winning technical support,you can be sure that you will have everything yourequire to meet your customers’ heating and hotwater needs. In the 2014 Which? survey, Worcestercustomers with a Greenstar oil-fired boiler wererecognised as being the most satisfied.In this easy-to-use pocket guide, you will findessential information on every Greenstar oil-firedheating and hot water appliance currently availablefrom the Worcester range, as well as informationabout our Greenskies solar thermal solutions.This includes technical data such as dimensions,outputs, flue options, accessories, productcodes and much more – all laid out clearly andconcisely, with the aid of diagrams, tables and acomprehensive contents page.Energy Saving productrecommended by theEnergy Saving Trust.Solar compatibleGreenstore Cylindercompatible2Seasonal efficiency is given as theSEDBUK number. The value is usedin the UK Government’s StandardAssessment Procedure (SAP) for energyrating of dwellings. The test data fromwhich it has been calculated has beencertified by a notified body as indicated.

ContentsFlue terminal positioning6-7Condensing oil-fired boilersFloor standing combiFloor standing systemGreenstar Heatslave II8-9Greenstar Heatslave II External10 - 11Greenstar Danesmoor System12 - 13Greenstar Danesmoor System Utility14 - 15Greenstar Danesmoor System External 16 - 17Floor standing regularGreenstar Danesmoor18 - 19Greenstar Danesmoor Utility20 - 21Greenstar Danesmoor External22 - 23Wall mounted regularGreenstar Danesmoor WM24 - 25Floor standing regularGreenstar Utility26 - 27Plume management systemPlug-in controls2828 - 31AccessoriesGreenstar oil-fired boiler accessories32 - 36Greensource HydrolightSplit Air to Water heat pumps37Solar thermal panelsGreenskies Solar-Lux38 - 43Greenskies Solar-Lifestyle44 - 51Greenskies Solar-Lito52 - 57Greenstore unvented cylinder seriesGreenstore unvented cylinder series58 - 59Greenstore solar compatible unvented cylinder series60 - 61Useful contactsOther Bosch companies62 - 6363Conversion tables64 - 65Consumer & technical literature66 - 67Worcester training68 - 71Useful numbers723

Worcester and you.Making a difference.As part of the Bosch Group,Worcester products aredesigned and manufacturedto provide customers with the highest levelsof quality and reliability which are synonymouswith the Bosch name throughout the world.Worcester is a part of Europe’s largest supplier ofheating products, and with our UK-based resources,as well as the Bosch Group’s global infrastructure,we can offer you the value-added solutions youdeserve. Worcester employs a nationwide networkof Service Engineers and technically trained FieldSales Managers supported by an experiencedtechnical services team which is able to providecomprehensive support and advice from designingsystem layouts through to installation.4

The reception and main entranceat our Worcester headquartersWorcester is dedicated to providing energy efficientgas- and oil-fired condensing boilers, as well as anextensive range of renewable technologies. All ofour products have been developed and introducedwith the aim of helping the UK to achieve theGovernment’s efficiency targets.“At Worcester we recognise the vital role you play inthe specification and installation of energy efficientappliances in homes across the UK. We will continueto invest in our products, people, facilities and addedvalue services to ensure you have all you requirein order to deliver only the best solutions to yourcustomers’ requirements.”Carl Arntzen,Managing Director,Bosch Thermotechnology Ltd.5

Flue terminal positioningAll measurements in millimetresConventional 6Note All measurements are the minimum clearances required. Terminals must be positioned so as to avoid combustionproducts entering the building. In spite of the dimensionsgiven here, the terminal must not be closer than 300mm tocombustible material. In the case of a thatched roof, thisdimension should be doubled. Terminals must be positioned so that products of combustiondo not enter or accumulate around the building. Terminals must be at least 1.8 metres from an oil storage tankunless a wall with at least 30 minutes fire resistance, whichextends 300mm wider and higher than the tank, is installed.Key to illustration61.600mm distance to a boundary, unless it will cause anuisance. BS 5410: Part 1 recommends that care is takenwhen siting terminals in relation boundaries.2.600mm below eaves and balconies; this can be reducedto 75mm, as long as the flue terminal is extended to clearany overhang.7

2m1m52mm11104mmVelux ordormer window600109Drainpipe122,50014ExternalOil Boiler300300133.600mm horizontally or vertically to an opening, air brick oropening window.4.1,500mm vertically from a terminal on the same wall.5.750mm horizontally from a flue on the same wall.6.300mm to an internal or external corner.7.Minimum 600mm straight flue before any bend on aconventional flue.8.750mm between a vertical structure and a flue terminal.9.1,000mm below a Velux or dormer window, 300mm above orto either side of the Velux or dormer window or any openingon a sloping roof.10. 600mm above the highest point of an intersection with a roof.11. Any flue must fall back towards the boiler by 3 or 52mm forevery metre of flue so that the condensate drains back to theboiler for disposal.12. 300mm to any vertical sanitary pipe work or drain pipe.13. Flue clearance must be at least 300mm above ground orbalcony level. Terminal guards must be fitted if the flue is lessthan 2 metres from the ground or if a person could come intocontact with flue terminal.14. 2,500mm between terminals facing each other.7

Floor standing condensing combi boilersGreenstar Heatslave II Front:600mm*Note: Although clearance abovethe Heatslave range is stated to be300mm, a removable worktop maybe placed directly above the boiler,allowing 10mm clearance.600mm520mmBoiler output Flow rate** Boiler(kW)(l/min)weightSEDBUK20052009Oil burnerPart no.Greenstar Heatslave II 12/1812 to 1815†124kg 90.4% 89.4%Riello7 716 100 129RDB2.2*Greenstar Heatslave II 18/2518 to 2518†126kg 90.2% 89.2%Riello7 716 100 130RDB2.2*Greenstar Heatslave II 25/3225 to 3222†128kg 90.0% 89.0%Riello7 716 100 131RDB2.2**Suitable for kerosene (28 sec oil) only**Maximum flow rate to produce a 40 C temperature rise over a 90l draw off†Restricted DHW flow rateControl optionsPart no.DescriptionIntelligent controls7 716 192 065#FR10 Intelligent Room Thermostat7 716 192 764Outdoor weather sensorDigital, wireless programmers & room thermostats7 733 600 003Comfort plug-in twin channel programmer7 733 600 001Comfort I RF wireless room thermostatand plug-in twin channel programmer7 733 600 002Comfort II RF wireless programmable roomthermostat and plug-in RF receiver#For use with third party 230V timer only.8

SolarcompatibleFlue lengthsMaximum flue High level horizontal5,000mm5,000mm5,000mmRear exit horizontal6,000mm6,000mm6,000mmSide exit 0mm*8,000mm*Plume management5,000mm5,000mm4,000mmNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.*Flue damper (7 716 190 101) required when vertical flue length exceeds 6m.Horizontal and vertical fluing optionsComponentsPart no.Description125mm diameter7 716 190 064 Standard telescopic flue kit (460 - 670mm)7 716 190 062 Short telescopic flue kit (360 - 460mm)7 716 190 103 Vertical flue kit (1,080mm)7 716 190 033 1,000mm extension (960mm)7 716 190 097 600mm extension7 716 190 034 90 flue bend7 716 190 035 45 flue bend (pair)7 716 190 105 Infill plate kit (for high level horizontal flues)7 716 190 101 Flue damper7 716 191 090 Flashing – flat roof7 716 191 091 Flashing – pitched roof7 716 190 050 Stainless steel flue terminal guardConventional flue7 716 190 104 Conventional flue adaptor kitPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)Oilfit flexible flue kit7 716 190 076 Oilfit flexi flue kit (8m)7 716 190 077 Oilfit flexi flue kit (12m)7 716 190 068* Telescopic extension7 716 190 066* 1,000mm extension kit7 716 190 067* 500mm extension kit7 716 190 069* 45º bend7 716 190 074 Wall cover plate kit*Stainless steel9

Floor standing condensing external combi boilersGreenstar Heatslave IIExternal seriesClearancesAbove600mmFront600mmRH/LH flue outleton opposite side 10mm950mmRH flue outleton rear85mmLH flue outleton rear10mmRear flue outlet on side 150mm770mm640mmRear rear flue outlet2,500mmIt is strongly recommended that theflue terminal faces away from wallsto reduce the possibility of wettingoccurring.Boiler output Flow rate** Boiler(kW)(l/min)weightSEDBUK20052009Oil burnerPart no.Greenstar Heatslave II External 12/1812 to 1815†151kg 90.4% 89.4%Riello7 716 100 138RDB2.2*Greenstar Heatslave II External 18/2518 to 2518†154kg 90.2% 89.2%Riello7 716 100 139RDB2.2*Greenstar Heatslave II External 25/3225 to 3222†158kg 90.0% 89.0%Riello7 716 100 140RDB2.2**Suitable for kerosene (28 sec oil) only**Maximum flow rate to produce a 40 C temperature rise over a 90l draw off†Restricted DHW flow rateControl optionsPart no.DescriptionIntelligent controls7 716 192 065#FR10 Intelligent Room Thermostat7 716 192 764Outdoor weather sensorDigital, wireless programmers & room thermostats7 733 600 003Comfort plug-in twin channel programmer7 733 600 0011Comfort I RF wireless room thermostatand plug-in twin channel programmer7 733 600 0021Comfort II RF wireless programmable roomthermostat and plug-in RF receiver#For use with third party 230V timer only.1 Must be used with Comfort Wall Plate Kit 7 733 600 039.10

SolarcompatibleFlue lengthsMaximum flue lengthsExternal mPlume management kitNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.Horizontal and vertical fluing optionsBoiler comes with standard horizontal flue kit.A 90º bend is required when fluing to the side.ComponentsPart no.Description125mm diameter7 716 190 034Internal 90 flue bend(used inside boiler when fluing to side)7 716 190 050 Stainless steel flue terminal guardPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)11

Floor standing condensing system boilersGreenstar DanesmoorSystem seriesClearancesAbove: 10mm(annual service)Above: 300mm(maintenance & repair)855mm370mmBoiler weight5mmRight:5mmFront:600mmThe appliance is suitable foran under-worktop installationproviding that the worktop abovethe boiler (min. 10mm clearance)is removable for maintenanceand repair.600mmBoiler output(kW)Left:SEDBUK20052009Oil burnerPart no.Greenstar Danesmoor System 12/1812 to 1895kg93.2% 91.1%RielloRDB2.2*7 716 100 135Greenstar Danesmoor System 18/2518 to 2598kg93.0% 90.9%RielloRDB2.2*7 716 100 136Greenstar Danesmoor System 25/3225 to 32102kg92.8% 90.7%RielloRDB2.2*7 716 100 137*Suitable for kerosene (28 sec oil) onlyControl optionsPart no.7 716 192 03312DescriptionDigital plug-in 7 day twin channel programmer

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue High level horizontal5,000mm5,000mm5,000mmRear exit horizontal6,000mm6,000mm6,000mmSide exit 0mm*8,000mm*Plume management5,000mm5,000mm4,000mmNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.*Flue damper (7 716 190 101) required when vertical flue length exceeds 6m.Horizontal and vertical fluing optionsComponentsPart no.Description125mm diameter7 716 190 064 Standard telescopic flue kit (460 - 670mm)7 716 190 062 Short telescopic flue kit (360 - 460mm)7 716 190 103 Vertical flue kit (1,080mm)7 716 190 033 1,000mm extension (960mm)7 716 190 097 600mm extension7 716 190 034 90 flue bend7 716 190 035 45 flue bend (pair)7 716 191 105 Infill plate kit (for high level horizontal flues)7 716 190 101 Flue damper7 716 191 090 Flashing – flat roof7 716 191 091 Flashing – pitched roof7 716 190 050 Stainless steel flue terminal guardConventional flue7 716 190 104 Conventional flue adaptor kitPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)Oilfit flexible flue kit7 716 190 076 Oilfit flexi flue kit (8m)7 716 190 077 Oilfit flexi flue kit (12m)7 716 190 068* Telescopic extension7 716 190 066* 1,000mm extension kit7 716 190 067* 500mm extension kit7 716 190 069* 45º bend7 716 190 074 Wall cover plate kit*Stainless steel13

Floor standing condensing utility system boilersGreenstar DanesmoorSystem Utility seriesClearancesAbove: 10mm(annual service)Above: 300mm(maintenance & repair)855mm370mmBoiler weight5mmRight:5mmFront:600mmThe appliance is suitable foran under-worktop installationproviding that the worktop abovethe boiler (min. 10mm clearance)is removable for maintenanceand repair.600mmBoiler output(kW)Left:SEDBUK20052009Oil burnerPart no.Greenstar Danesmoor System Utility 12/1812 to 1895kg93.2% 91.1%RielloRDB2.2*7 716 100 147Greenstar Danesmoor System Utility 18/2518 to 2598kg93.0% 90.9%RielloRDB2.2*7 716 100 148Greenstar Danesmoor System Utility 25/3225 to 32102kg92.8% 90.7%*Suitable for kerosene (28 sec oil) only14RielloRDB2.2*7 716 100 149

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue High level horizontal5,000mm5,000mm5,000mmRear exit horizontal6,000mm6,000mm6,000mmSide exit 0mm*8,000mm*Plume management5,000mm5,000mm4,000mmNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.*Flue damper (7 716 190 101) required when vertical flue length exceeds 6m.Horizontal and vertical fluing optionsComponentsPart no.Description125mm diameter7 716 190 064 Standard telescopic flue kit (460 - 670mm)7 716 190 062 Short telescopic flue kit (360 - 460mm)7 716 190 103 Vertical flue kit (1,080mm)7 716 190 033 1,000mm extension (960mm)7 716 190 097 600mm extension7 716 190 034 90 flue bend7 716 190 035 45 flue bend (pair)7 716 191 105 Infill plate kit (for high level horizontal flues)7 716 190 101 Flue damper7 716 191 090 Flashing – flat roof7 716 191 091 Flashing – pitched roof7 716 190 050 Stainless steel flue terminal guardConventional flue7 716 190 104 Conventional flue adaptor kitPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)Oilfit flexible flue kit7 716 190 076 Oilfit flexi flue kit (8m)7 716 190 077 Oilfit flexi flue kit (12m)7 716 190 068* Telescopic extension7 716 190 066* 1,000mm extension kit7 716 190 067* 500mm extension kit7 716 190 069* 45º bend7 716 190 074 Wall cover plate kit*Stainless steel15

Floor standing condensing external system boilersGreenstar DanesmoorSystem External seriesClearancesFlue orientation from front(mm)950mm565mmBoiler *50**2,500*Above600600600Front600600600*From end of flue terminal allow2,500mm clearance.**200mm if using a high level terminalexiting through the rear panel.780mmBoiler output(kW)KeyLeftSEDBUK20052009Oil burnerPart no.Greenstar Danesmoor System External 12/1812 to 18108kg93.2% 91.1%RielloRDB2.2*7 716 100 150Greenstar Danesmoor System External 18/2518 to 25111kg93.0% 90.9%RielloRDB2.2*7 716 100 151Greenstar Danesmoor System External 25/3225 to 32115kg92.8% 90.7%*Suitable for kerosene (28 sec oil) only16RielloRDB2.2*7 716 100 152

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue lengthsExternal mPlume management kitHorizontal and vertical fluing optionsBoiler comes with standard horizontal flue kit.A 90º bend is required when fluing to the side.ComponentsPart no.Description125mm diameter7 716 190 034Internal 90 flue bend(used inside boiler when fluing to side)7 716 190 050 Stainless steel flue terminal guardPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)17

Floor standing condensing regular boilersGreenstar Danesmoorregular seriesClearancesAbove: 10mm(annual service)Above: 300mm(maintenance & repair)855mm370mmBoiler weight5mmRight:5mmFront:600mmThe appliance is suitable foran under-worktop installationproviding that the worktop abovethe boiler (min. 10mm clearance)is removable for maintenanceand repair.600mmBoiler output(kW)Left:SEDBUK20052009Oil burnerPart no.RielloRDB2.2*7 716 100 132RielloRDB2.2*7 716 100 133RielloRDB2.2*7 716 100 134Greenstar Danesmoor 12/1812 to 1886kg93.2% 91.1%Greenstar Danesmoor 18/2518 to 2589kg93.0% 90.9%Greenstar Danesmoor 25/3225 to 3293kg92.8% 90.7%*Suitable for kerosene (28 sec oil) onlyControl optionsPart no.7 716 192 03318DescriptionDigital plug-in 7 day twin channel programmer

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue High level horizontal5,000mm5,000mm5,000mmRear exit horizontal6,000mm6,000mm6,000mmSide exit 0mm*8,000mm*Plume management5,000mm5,000mm4,000mmNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.*Flue damper (7 716 190 101) required when vertical flue length exceeds 6m.Horizontal and vertical fluing optionsComponentsPart no.Description125mm diameter7 716 190 064 Standard telescopic flue kit (460 - 670mm)7 716 190 062 Short telescopic flue kit (360 - 460mm)7 716 190 103 Vertical flue kit (1,080mm)7 716 190 033 1,000mm extension (960mm)7 716 190 097 600mm extension7 716 190 034 90 flue bend7 716 190 035 45 flue bend (pair)7 716 191 105 Infill plate kit (for high level horizontal flues)7 716 190 101 Flue damper7 716 191 090 Flashing – flat roof7 716 191 091 Flashing – pitched roof7 716 190 050 Stainless steel flue terminal guardConventional flue7 716 190 104 Conventional flue adaptor kitPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)Oilfit flexible flue kit7 716 190 076 Oilfit flexi flue kit (8m)7 716 190 077 Oilfit flexi flue kit (12m)7 716 190 068* Telescopic extension7 716 190 066* 1,000mm extension kit7 716 190 067* 500mm extension kit7 716 190 069* 45º bend7 716 190 074 Wall cover plate kit*Stainless steel19

Floor standing condensing regular utility boilersGreenstar DanesmoorUtility regular seriesClearancesAbove: 10mm(annual service)Above: 300mm(maintenance & repair)855mm370mmBoiler weight5mmRight:5mmFront:600mmThe appliance is suitable foran under-worktop installationproviding that the worktop abovethe boiler (min. 10mm clearance)is removable for maintenanceand repair.600mmBoiler output(kW)Left:SEDBUK20052009Oil burnerPart no.RielloRDB2.2*7 716 100 141RielloRDB2.2*7 716 100 142RielloRDB2.2*7 716 100 143Greenstar Danesmoor Utility 12/1812 to 1886kg93.2% 91.1%Greenstar Danesmoor Utility 18/2518 to 2589kg93.0% 90.9%Greenstar Danesmoor Utility 25/3225 to 3293kg92.8% 90.7%*Suitable for kerosene (28 sec oil) only20

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue High level horizontal5,000mm5,000mm5,000mmRear exit horizontal6,000mm6,000mm6,000mmSide exit 0mm8,000mm*Plume management5,000mm5,000mm4,000mmNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.*Flue damper (7 716 190 101) required when vertical flue length exceeds 6m.Horizontal and vertical fluing optionsComponentsPart no.Description125mm diameter7 716 190 064 Standard telescopic flue kit (460 - 670mm)7 716 190 062 Short telescopic flue kit (360 - 460mm)7 716 190 103 Vertical flue kit (1,080mm)7 716 190 033 1,000mm extension (960mm)7 716 190 097 600mm extension7 716 190 034 90 flue bend7 716 190 035 45 flue bend (pair)7 716 191 105 Infill plate kit (for high level horizontal flues)7 716 190 101 Flue damper7 716 191 090 Flashing – flat roof7 716 191 091 Flashing – pitched roof7 716 190 050 Stainless steel flue terminal guardConventional flue7 716 190 104 Conventional flue adaptor kitPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)Oilfit flexible flue kit7 716 190 076 Oilfit flexi flue kit (8m)7 716 190 077 Oilfit flexi flue kit (12m)7 716 190 068* Telescopic extension7 716 190 066* 1,000mm extension kit7 716 190 067* 500mm extension kit7 716 190 069* 45º bend7 716 190 074 Wall cover plate kit*Stainless steel21

Floor standing condensing external regular boilersGreenstar DanesmoorExternal regular seriesClearancesFlue orientation from front(mm)950mm565mmBoiler *50**2,500*Above600600600Front600600600*From end of flue terminal allow2,500mm clearance.**200mm if using a high level terminalexiting through the rear panel.780mmBoiler output(kW)KeyLeftSEDBUK20052009Oil burnerPart no.Greenstar Danesmoor External 12/1812 to 1899kg93.2% 91.1%RielloRDB2.2*7 716 100 144Greenstar Danesmoor External 18/2518 to 25102kg93.0% 90.9%RielloRDB2.2*7 716 100 145Greenstar Danesmoor External 25/3225 to 32106kg92.8% 90.7%*Suitable for kerosene (28 sec oil) only22RielloRDB2.2*7 716 100 146

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue lengthsExternal mPlume management kitHorizontal and vertical fluing optionsBoiler comes with standard horizontal flue kit. A 90ºbend is required when fluing to the side.ComponentsPart no.Description125mm diameter7 716 190 034Internal 90 flue bend(used inside boiler when fluing to side)7 716 190 050 Stainless steel flue terminal guardPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)23

Wall mounted condensing regular boilersGreenstar Danesmoorwall mounted mFront:600mm**20mm to a removable door410mm600mmBoiler output(kW)Boiler weightSEDBUK20052009Oil burnerPart no.RielloRDB 1†7 716 100 124RielloRDB 2.2†7 716 100 125Greenstar Danesmoor WM 12/1812 to 1872kg92.7% 90.7%Greenstar Danesmoor WM 18/2518 to 2572kg92.8% 90.7%†Suitable for kerosene (28 sec oil) onlyControl optionsPart no.7 716 192 03324DescriptionDigital plug-in 7 day twin channel programmer

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue 00mm–80mm5,000mm4,000mmPlume managementNote: For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.For every 90º plume kit bend deduct 1,000mm and 500mm for every 45º plume kit bend.Horizontal and vertical fluing optionsComponentsPart no.Description125mm diameter7 716 190 064** Standard telescopic flue kit (460 - 670mm)7 716 190 062** Short telescopic flue kit (360 - 460mm)7 716 190 103 Vertical BF kit (1,080mm)7 716 190 033 1,000mm extension (960mm)7 716 190 097 600mm extension7 716 190 034 90 flue bend7 716 190 035 45 flue bend (pair)7 716 191 174 Support bracket kit7 716 191 090 Flashing – flat roof7 716 191 091 Flashing – pitched roof7 716 190 050 Stainless steel flue terminal guard**For horizontal fluing a 90º elbow must be orderedPlume management7 716 190 092 Plume management kit7 716 190 093 1,000mm extension7 716 190 095 90 bend7 716 190 094 45 bend (pair)25

Floor standing condensing regular utility boilersGreenstar Utility regular seriesClearancesAbove flue: 300mm*Left:1,012mm10mmRight:10mmFront:600mm*Note: Although clearance abovethe Greenstar Utility range is statedto be 300mm, a removable worktopmay be placed directly above theboiler, allowing 10mm clearance.815mm520mmBoiler output(kW)Boiler weightSEDBUK20052009Oil burnerPart no.RielloRDB 3.2*7 716 100 103RielloRDB 4.2*7 716 100 104Greenstar Utility 32/5032 to 50270kg93.0% 90.7%Greenstar Utility 50/7050 to 70280kg92.5% 90.5%*Suitable for kerosene (28 sec oil) only26

GreenstoreCylindercompatibleSolarcompatibleFlue lengthsMaximum flue lengthsDiameter150mmOrientation32/5050/70High level horizontal2,000mm2,000mmRear exit horizontal3,000mm3,000mmSide exit : For every 90º flue bend deduct 1,000mm and 500mm for every 45º flue bend.Horizontal and vertical fluing optionsComponentsPart no.Description150mm diameter7 716 190 043 Standard horizontal flue kit (880mm)7 716 190 044 Vertical BF kit (1,290mm)7 716 190 045 Flue extension (960mm)7 716 190 046 90 flue bend7 716 190 047 45 flue bend (pair)7 716 190 051 Stainless steel flue terminal guardExternal flues – 150mm diameter7 716 190 060 External flue extension7 716 190 096 External flue 90 bend7 716 190 061 External flue 45 bend (pair)Conventional flue7 716 190 049 Conventional flue adaptor kitOilfit flexible flue kit – 130mm diameter7 716 190 079 Oilfit flexi flue kit (8m)7 716 190 080 Oilfit flexi flue kit (12m)7 716 190 081 Oilfit flexi flue kit (15m)7 716 190 072* Telescopic extension7 716 190 070* 1,000mm extension kit7 716 190 071* 500mm extension kit7 716 190 073* 45º bend7 716 190 075 Wall cover plate kit*Stainless steel27

ControlsNEWGreenstar Heatslave II controlsNEW Greenstar Comfort controlsGreenstar Comfort plug-in twin channel programmer(for use with internal and external models)Part no. 7 733 600 003 Simple menu navigation Heating programme visualisation bar 7-day time control for heating and hot water.Greenstar Comfort I RF wireless room thermostatand plug-in twin channel programmer(for use with internal models)Part no. 7 733 600 001All the features of Comfort PLUS Enhanced load compensation for increased efficiency.No wiring requiredExtremely reliable RF signal. 28

Greenstar Comfort II RF wireless programmableroom thermostat and plug-in RF receiver(for use with internal models)Part no. 7 733 600 002All the features of Comfort & Comfort I PLUS 6 adjustable heating temperatures per daySet programme at the room thermostatRemote access to boiler diagnostic codes. Comfort Wall Plate KitPart no. 7 733 600 03929

Intelligent weather and load compensation controlsFR10 intelligent room thermostat(for use with internal and external models)Part no. 7 716 192 065 Load compensationBoiler output automatically adjusted to precisely meetthe heat demand of the property at maximum efficiencyMaximises the condensing boiler’s operationFor use with a 230V programmer. Not compatible withWorcester Comfort controls.Outdoor weather sensor(for use with internal and external models)Part no. 7 716 192 764 30Monitors external temperatures to offer weathercompensation in combination with the in-built heatcurves of the Greenstar Heatslave II. For use with a 230Vprogrammer. Not compatible with Worcester Comfortcontrols. To be used with a 230V room thermostat.

Greenstar Danesmoor System (kitchen),Danesmoor regular (kitchen) andDanesmoor WM controlsDigital plug-in 7 day twin channel programmerPart no. 7 716 192 033 Plugs into the boiler fascia panel and offers 3 separatetime periods for both heating and hot water.31

The WorcesterCondenseSure siphonWith climate change and extreme weather variationsbecoming increasingly common, and very cold winters withtemperatures as low as -20 C being experienced, practicessuch as externally-run condensate discharge pipework arenow being questioned.A universal fitting for new and existing installationsThe Worcester CondenseSure siphon has been designedto allow a more flexible approach to boiler siting. Althoughdeveloped specifically for Worcester Greenstar gas- andoil-fired boilers, the Worcester CondenseSure can also befitted to any make of condensing boiler for both new andretrofit installations.Ease of installationThe CondenseSure has been designed with ease ofinstallation in mind and is suitable for most boilerapplications. Although it can be clipped to a flow pipeunder a wall-hung boiler, the CondenseSure can also bewall-mounted away from the boiler and connected to thecondensate discharge offering a wide range of installationoptions for oil boilers.FeaturesBenefitsNo power consumptionNo electrical wiringconnection or supply needed,meaning zero running costsNo moving partsNo failure of componentsCan be installed on newor existing installationsSuitable for any gas- oroil-fired condensing boilersCan be attached to 22mm Uses ‘free’ energy from theheating flow pipeworkpipe to heat the condensate32Under boiler or remoteinstallationFlexibilityNo electrical connectionsNo electr

Solar thermal panels Greenskies Solar-Lux 38 - 43 Greenskies Solar-Lifestyle 44 - 51 Greenskies Solar-Lito 52 - 57 Greenstore unvented cylinder series Greenstore unvented cylinder series 58 - 59 Greenstore solar compatible unvented cylinder series 60 - 61 Useful contacts 62 - 63 Other Bosch companies 63 Conversion tables 64 - 65