ComEd HVAC Incentives Worksheet

Transcription

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Directions: Please save a copy of this form to your computer by selecting “File/Save As” before entering text andnumbers. Then fill in your information electronically and select “Save.” Note that this form requires Adobe Reader version 11.0 to function properly. Download the most recent version of Adobe Acrobat Reader DC athttp://get.adobe.com/reader.General Specifications1. Pre-application is required; review instructions on the standard incentives application form. Wait fora reservation letter before starting your project.2. Building energy management measures are available in the energy management incentiveworksheet.ChillersSpecifications and Eligible Equipment1. This incentive is only applicable to systems used for space cooling. Process cooling systems are not eligible for thisincentive, but may be eligible for a custom incentive. Visit ComEd.com/Custom for more information. Will the proposed chiller(s) be used for space cooling only?YesNo2. Must have a rated kW/ton for the Integrated Part Load Value (IPLV) that is less than the qualifying efficiency.3. Efficiency rating must be based on AHRI Standard 550/590 (I-P)-2018 for IPLV conditions and not based onfull-load conditions.4. Must qualify for either IECC 2018 Path A or B efficiency, but will receive incentives based on qualifyingefficiencies below.5. The chillers must meet ARI standards 550/590-2018, be UL listed, and use a minimum ozone-depletingrefrigerant that complies with local codes (e.g., HCFC or HFC).6. The AHRI net capacity value should be used to determine the chiller tons.7. A manufacturer’s specification sheet with the rated kW/ton-IPLV or COP-IPLV and nominal tonnage mustaccompany the application. The specification sheet must also break out the kW/ton values at 100%, 75%, 50%, and25% load per AHRI Standard 550/590 (I-P)-2018.8. Redundant chillers are not eligible for incentives Will the proposed chiller(s) be used as a redundant chiller(s)?(A redundant chiller is estimated to run less than 500 hours a year).Customer Name:1YesNo

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Water-Cooled Chiller 5 for IPLV improvement per ton*New or replacement water-cooled chiller (centrifugal, scroll/helical-rotary, reciprocating).CentrifugalSIZE CATEGORYMINIMUM QUALIFYING EFFICIENCY 300 tons0.550 kW/ton-IPLV efficiency300 - 399 tons0.520 kW/ton-IPLV efficiency 400 tons0.500 kW/ton-IPLV efficiency*Efficiency incentive is paid for an efficiencyrating above the qualifying efficiency. Theincentive is 5.00 per 0.01 kW/ton IPLV forwater-cooled chillers.Scroll or helical-rotary (screw)SIZE CATEGORYMINIMUM QUALIFYING EFFICIENCY 75 tons0.600 kW/ton-IPLV efficiency75 - 149 tons0.560 kW/ton-IPLV efficiency150 - 299 tons0.540 kW/ton-IPLV efficiency300 - 599 tons0.520 kW/ton-IPLV efficiency 600 tons0.500 kW/ton-IPLV efficiencyReciprocatingSIZE CATEGORYMINIMUM QUALIFYING EFFICIENCY 75 tons0.600 kW/ton-IPLV efficiency75 - 149 tons0.560 kW/ton-IPLV efficiency150 - 299 tons0.540 kW/ton-IPLV efficiency300 - 599 tons0.520 kW/ton-IPLV efficiency 600 tons0.500 kW/ton-IPLV efficiencyAir-Cooled Chiller 6 for IPLV improvement per ton*New or replacement air-cooled chiller.SIZE CATEGORYMINIMUM QUALIFYING EFFICIENCY 150 tons0.876 kW/ton-IPLV efficiency 150 tons0.857 kW/ton-IPLV efficiency2*Efficiency incentive is paid for an efficiencyrating above the qualifying efficiency. Theincentive is 6.00 per 0.01 kW/ton IPLV forair-cooled chillers.

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Incentive Calculation for Water-Cooled and Air-Cooled ChillersEQUIPMENT TYPE INSTALLEDIPLVEFFICIENCY OFUNIT INSTALLED(kW/TON)(A)UNIT SIZE(TONS)(B)NUMBER OFUNITSINSTALLED(C)INCENTIVE PERIPLVIMPROVEMENT(D)IPLV IMPROVEMENTBELOW CODEREQUIREMENT(AxBxCxDx100)INCENTIVEexample: centrifugal chiller0.440200.001 5.000.11 11,000INCENTIVE SUBTOTAL 3

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Chiller with integrated VSDOil-free Bearing Chiller* 100 per ton**New or replacement water-cooled chiller with integratedVSD for centrifugal chillers up to 1,250 tons and screwchillers up to 550 tons. Larger chillers may be eligible forcustom incentives. 200 per ton**New or replacement water-cooled chillerwith oil-free bearings and VSD up to 1,250tons. Chillers over 1,250 tons may be eligiblefor custom incentives.Specifications1. The chiller full load efficiency rating (kW/ton FL) must be based on AHRI Standard 550/590-2018 and beless than or equal to the baseline efficiencies shown below.2. The chillers must meet AHRI standards 550/590-2018, be UL listed, and use a minimum ozone-depletingrefrigerant that complies with local code(e.g., HCFC or HFC).3. The AHRI net capacity value should be used to determine the chiller tonnage.4. A manufacturer’s specification sheet with the rated kW/Ton or COP must accompany the application.5. If a VSD or oil-free bearing based chiller is being installed, the project is only eligible for this incentive andnot the water-cooled chiller measure.6. Chiller must qualify under either IECC 2018 Path A or Path B efficiency requirements.7. If a chiller operating on 4160V supply is being installed, it would not be eligible for this measure, but it maybe eligible for custom incentives.CHILLER TYPEHelical-RotaryScrewCentrifugalSIZE (Tons)BASELINE IECC 2018 Path ABASELINE IECC 2018 Path B 750.75 kW/ton FL0.78 kW/ton FL75 to 1490.72 kW/ton FL0.75 kW/ton FL150 to 2990.66 kW/ton FL0.68 kW/ton FL300 to 5990.61 kW/ton FL0.625 kW/ton FL600 0.56 kW/ton FL0.585 kW/ton FL 1500.61 kW/ton FL0.695 kW/ton FL150 to 3000.61 kW/ton FL0.635 kW/ton FL300 to 3990.56 kW/ton FL0.595 kW/ton FL 4000.56 kW/ton FL0.585 kW/ton FLEQUIPMENT TYPE INSTALLEDexample: integrated VSD chiller(B)(A)UNIT SIZE (TONS)INCENTIVE PER TON(AxB)INCENTIVE200.00 100.00 20,000*This measure was previously known as a magnetic bearing chiller.**Eligibility and incentives are based on IL Statewide TechnicalResource Manual Version 10.0 draft and may be subject to change.4

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Variable Speed Drive on HVAC Chiller 60 per tonVariable-speed drives (VSDs) installed on an existing chiller (where applicable).Specifications1. The installation of a VSD must accompany the permanent removal or disabling of any throttling devices.2. New chillers with integrated VSDs are not eligible for this incentive, but may be eligible for the water andair-cooled chiller incentives.3. This measure cannot be used in conjunction with the energy management system measure.4. Chillers with existing VSDs and process chillers are not eligible for this incentive.APPLICATION DESCRIPTION(A)SIZE (TON)(B)NUMBER INSTALLED(C)INCENTIVE PER TON 60.00 60.00 60.00 60.00INCENTIVE SUBTOTAL 5(A x B x C)INCENTIVE

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Variable Speed Drive on Fan or Pump 90 per HPInstallation of a VSD on an HVAC fan or pump 200 HP or less.Specifications and Eligible Equipment1. The VSD must be installed with automatic control technology.2. Installation of the VSD must accompany the permanent removal or disabling of existing flow control devices.3. VSD must be installed on a chilled water pump, hot water pumps and cooling tower fans.4. The following VSD applications are not eligible. Please indicate below if your project includes any of them:Does your project includethese applications? Replacement of an existing VSDYesNo VSD installed on equipment which operates less than 1200 hours per yearYesNo VSD installed on redundant/backup motorsYesNoYesNo VSD installed in place of multi-speed flow control equipment (e.g., two-speed coolingtower fans) VSD installed for the sole purpose of “soft-starting” motorsYesNo VSD installed on pumps where affinity laws are not in effect, such as sump pumpsYesNo5. The following VSD applications are not eligible for this incentive but may be eligible for custom incentive. Pleaseindicate below if your project includes any of them:Does your project includethese applications?YesYesNoNo YesNo VSD installed in place of variable pitch blade flow control equipmentVSD installed for the purpose of reducing motor speed to a single set point and notmodulateVSD installation in a process load is not eligible for this incentive but may beeligible for a custom incentive.6. If new construction, VSDs required by code are not eligible.7. This measure cannot be used in conjunction with the energy management system measure.6

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022FAN OR PUMP ID TAGe.g. supply fan #1INSTALLATION CONTROLSTYPE CODE BEFORE VSDFROM TABLE 1FROMTABLE 2SFADDFAN TYPEFROMTABLE 3ESTIMATEDANNUALOPERATINGHOURSBI3,432(A)(B)MOTOR NOMINAL MOTORHORSEPOWER QUANTITY(MUST BE 200)50.00(C)INCENTIVEPER HPAxBxCINCENTIVE 90 4,500.001 90.00 90.00 90.00 90.00 90.00 90.00 90.00 90.00INCENTIVE REQUESTED Incentive cannot exceed 100 percent of the incremental measure cost and 75 percent of the total project cost and mustmeet all program terms and conditions.PLEASE DESCRIBE HOW THE VSD IS BEING MODULATED:Table 1: VSD Installation TypeTable 2: Control Before VSDTable 3: Fan TypeSFA - HVAC supply air fanRFA - HVAC return air fanBEF - Building exhaust fanMAF - Make-up air fanCTF - Cooling tower fanBDF - HVAC boiler draft fanCDWP - Condenser water pumpCHWP - Chilled water pumpFWP - Boiler feed water pumpHWP - Hot water pumpFM - Other HVAC fan (specify):DD - Discharge damperIGV - Inlet guide vanesOCV - Outlet control/throttle valveBV - BypassONF - On/offMISC - Other (specify):BI - Backward inclined fanFC - Forward curve fanMISC - Other (specify):PM - Other HVAC pump (specify):7

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Chilled Water Reset Controls 5 per tonInstall chilled water reset controls on existing chillers to allow them to operate at higher chilled water temperaturesduring periods of low cooling loads. The existing chilled water system must have a constant chilled water temperatureof 45 F or less.Specifications1.2.3.4.Only water and air-cooled chillers are eligible for this measure.Chillers with existing control strategies are not eligible for this measure.The control strategy must use a temperature reset of at least 5 F.A copy of the chiller’s mechanical drawings or operation plans must accompany the application to verify thatbaseline requirements are met.5. This measure cannot be used in conjunction with the energy management system measure.APPLICATION DESCRIPTION(A)UNIT SIZE (TONS)(B)NUMBER INSTALLED(C)INCENTIVE PER TON 5.00 5.00 5.00 5.00INCENTIVE SUBTOTAL 8(A x B x C)INCENTIVE

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022SEHA Tier 1 Room Air Conditioner 30 per tonA through-the-wall or built-in self-contained unit that is two tons (24,000 Btu/h) or less.Qualifying Efficiency:SIZE (Btu/h)EER 8,000 ( 0.67 tons) 12.18,000-13,999 (.67-1.2 tons) 12.014,000-19,999 (1.3-1.7 tons) 11.820,000-24,000 (1.67-2 tons) 10.3Specifications1. Must meet SEHA Tier 1 minimum qualifying efficiencies from the CEE, shown above.2. Disposal of existing unit must comply with local codes and ordinances.Package Terminal AC (PTAC) / Package Terminal Heat Pump (PTHP) 30 per tonA through-the-wall or built-in self-contained PTAC or PTHP that is two tons (24,000 Btu/h) or less.Qualifying Efficiency:EQUIPMENT TYPEPROGRAM QUALIFYING EFFICIENCYPTAC (Cooling mode)14.0 - (0.300 x Cap/1,000)EERPTHP (Cooling mode)14.0 - (0.300 x Cap/1,000)EERPTHP (Heating mode)3.7 - (0.052 x Cap/1,000)EERSpecifications1. Only units that have an EER greater than or equal to the efficiencies listed above qualify for the incentive.2. EER must be rated per AHRI 310/380.3. PTAC and PTHPs are eligible for standard or instant discount incentives. Customers who receive a ComEdEnergy Efficiency Program instant discount through a participating distributor for PTACs or PTHPs are noteligible to receive a standard incentive or vice versa.Room Air Conditioner and PTAC/PTHP Incentive CalculationAPPLICATION DESCRIPTION(A)EFFICIENCY OF UNITINSTALLED (EER) UNIT SIZE (TONS)(B)NUMBER INSTALLED(C)INCENTIVE PER TON 30.00 30.00 30.00 30.00INCENTIVE SUBTOTAL 9(A x B x C)INCENTIVE

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Guest Room Energy Management SystemSpecifications and Eligible Equipment1. Sensors must be controlled by automatic occupancy detectors or key cards.2. During unoccupied periods, the default setting for controlled units should differ by at least five degrees from theoperating set point.3. Incentive is per guest room controlled, rather than per sensor, for multi-room suites.4. Systems with networked control qualify for this incentive.5. Replacement or upgrades of existing occupancy-based controls are not eligible for this incentive.Note: Your gas company may offer an additional prescriptive or custom rebate for this measure. VisitNicorGasRebates.com, PeoplesGasRebates.com or NorthShoreGasRebates.com for more information.Guest Room Energy Management System (Electric Resistance Heat/AC) Number of 65 per guest roomNew installation of a temperature setback control system for individualguest rooms with electric heat and air conditioning.Guest Room Energy Management System (Heat Pump Heating/AC) 65 per guest roomNew installation of a temperature setback control system for individualguest rooms with heat pump heating and electric air conditioning.Guest Room Energy Management System (Natural Gas or No Heat/AC) 25 per guest roomNew installation of a temperature setback control system for individualguest rooms with natural gas heat and electric air conditioning.10units:Total coolingtons controlled:INCENTIVESUBTOTAL:Number ofunits:Total coolingtons controlled:INCENTIVESUBTOTAL:Number ofunits:Total coolingtons controlled:INCENTIVESUBTOTAL:

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Demand Controlled Ventilation 40 per 1,000 square feetRetrofit of an existing building ventilation system with controls that modulate outside air ventilation based onreal-time occupancy.Specifications and Eligible Equipment1. Conditioned space must be kept between 65 F and 78 F during operating hours (except for garages).2. System must currently have a fresh air requirement equal to or greater than 10 percent of supply airrequirements.3. For conditioned interior spaces, carbon dioxide sensors must be installed in conjunction with fully functioningeconomizers with zone level sensors or return system sensors.4. For garage spaces, fans must modulate the ventilation airflow based on pollutant concentrations (primarilycarbon monoxide) in the space.5. The incentive is calculated per square foot of area controlled, so a floor plan must be submitted with the preapproval application.6. This measure cannot be used in conjunction with the energy management system measure.7. Residential space cannot be included in the claimed square footage.Note: Your gas company may offer an additional prescriptive or custom rebate for this measure. VisitNicorGasRebates.com, PeoplesGasRebates.com or NorthShoreGasRebates.com for more information.Description:Size (sq.ft.):INCENTIVE SUBTOTAL:Restroom Exhaust Fan Occupancy Sensor 10 per fanInstallation of occupancy sensors on a stand-alone restroom exhaust fan with existing control from a manual switchthat is either tied or not tied to the lighting.Specifications and Eligible Equipment1. Existing restroom exhaust fan must be 0.6 amps to 2.0 amps.2. The occupancy sensor must automatically shut off the exhaust fan after a specified period of time whenno occupancy is detected.3. The fans cannot be controlled by any existing building automation system.4. Manual timers controlling the exhaust system do not qualify.5. The existing exhaust volume flow rate must be at least 75 cfm per toilet room fixture.Number of units:INCENTIVE SUBTOTAL:11

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Kitchen Demand Ventilation Controls (New or Retrofit) 400 per exhaust fan HPInstallation of new or retrofit commercial kitchen demand ventilation controls that vary the ventilation based oncooking load and/or time of day.Specifications and Eligible Equipment1. Control system must include: Temperature sensor in the hood exhaust collar and/or an optic sensor on the end of the hood Variable speed drive on the exhaust fan that will vary the rate of exhaust to what is needed Variable speed drive on the makeup air unit, if applicable Only applicable to replacement of existing equipment, not applicable for new construction2. Incentive is based on exhaust fan HP only (not makeup air fan HP). VSDs on the makeup air fan do not qualifyfor an additional incentive.Note: Your gas company may offer an additional prescriptive or custom rebate for this measure. VisitNicorGasRebates.com, PeoplesGasRebates.com or NorthShoreGasRebates.com for more information.DESCRIPTIONSIZE(HP)INCENTIVE SUBTOTAL Wireless Pneumatic Thermostat 100 per thermostatReplacement of an existing pneumatic thermostat with a new wireless pneumaticthermostat with a direct digital-to-pneumatic signal for control of such end devices as VAVboxes, fan powered boxes, reheat coils, fan coils and radiant heat.Square feet controlled:Specifications and Eligible Equipment1. Wireless pneumatic thermostat system must be new and include: Central time control for setback of space temperature Minimum setback space temperature of at least 8 F in both heating and airconditioning mode Minimum setback period of more than 2,200 hours per year2. System must include central control interface for all thermostats to set the spacetemperature setpoints for both heating and air conditioning mode.3. Thermostat may allow for manual override of space temperature setpoints but mustbe reset to central control setpoints after all setback periods.4. Thermostat must include auto-calibration feature to eliminate drift to better maintainspace temperature setpoint.12Number of units:INCENTIVE SUBTOTAL:

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Air-Side Economizer 50 per tonAn air-side economizer brings cooler outside air into a building to reduce the amount of mechanical cooling required.Incentives are available for retrofitting existing air-handling units, rooftop units and split-direct expansion systemsdesigned without the capability for 100 percent outside air and exhaust.Specifications and Eligible EquipmentNew dampers and controllers must be installed on an existing system.System must compare return and outside air temperatures.Control of the economizer can be either a comparison of dry-bulb temperature or enthalpy.System must be set to introduce outside air whenever it will reduce the requirement for mechanical cooling.System must be installed and commissioned by a certified professional.One hundred percent outside air units, such as kitchen or dedicated outdoor units, do not qualify for thisincentive.7. Repairs of existing economizers, and economizers installed on new units, are not eligible for incentives.1.2.3.4.5.6.APPLICATION DESCRIPTIONSIZE (TON)NUMBER INSTALLEDINCENTIVE SUBTOTAL Electronically Commutated Motor (ECM) on Fan-Powered Box 50 per motorInstallation of electronically commutated motor, brushless DC motor or othertype of variable-speed motor on a fan-powered terminal box, fan coil orHVAC supply/return air fan serving both heating and cooling systems.Specifications and Eligible Equipment1. The ECM must be rated for 10 HP or less.2. The ECM must have a controller set to control the motor speed based onthe difference between the indoor temperature and thermostat set point.3. Newly installed variable speed drives are not eligible for this measure.13Number of units:INCENTIVE SUBTOTAL:

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Ground Source Heat Pump 30 per ton per EER above minimum efficiencyInstallation of a new Ground Source Heat Pump in an existing facility, new construction or replacement of existingelectric heating and/or cooling equipment.IECC 2018 Minimum Requirements GSHP RequirementsEquipment TypeSize CategoryRating ConditionMinimum EfficiencyBrine to Air: Ground Loop (Cooling Mode) 135,000 Btu/h77 F entering water14.1 EERBrine to Water: Ground Loop (Cooling Mode) 135,000 Btu/h77 F entering water12.1 EERBrine to Air: Ground Loop (Heating Mode) 135,000 Btu/h32 F entering water3.2 COPBrine to Water: Ground Loop (Heating Mode) 135,000 Btu/h32 F entering water2.5 COPGround Source Heat Pump Incentive CalculationEQUIPMENT TYPE INSTALLEDexample: Brine to Water: Ground LoopEFFICIENCYEFFICIENCYCOOLINGHEATING COPEER164UNIT SIZE(Btu/h)COOLING EFFICIENCYIMPROVEMENT OVERBASELINE (EER)INCENTIVE65,0003.9 633.75INCENTIVE SUBTOTAL 14

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Rooftop Unit 12 per ton per EER above efficiency requirementInstallation of a new Rooftop Unit in an existing facility, new construction or replacement of existing electric heatingand/or cooling equipment.Specifications1. Rooftop units are eligible for standard or instant discount incentives. Customers who receive a ComEdEnergy Efficiency Program instant discount through a participating distributor for a rooftop unit arenot eligible to receive a standard incentive or vice versa.2. For additional roof-top and split system incentives, please see the DX tune-up worksheet at ComEd.com/Worksheets.IECC 2018 Minimum Requirements Cool SystemsEQUIPMENT TYPESIZE CATEGORYHEATING SECTION TYPESUBCATEGORY ORRATING CONDITIONEFFICIENCYREQUIREMENTTEST PROCEDUREAir Conditioners,Air Cooled 65,000 Btu/hAllSingle Package14.0 SEERAHRI 210/240Air Conditioners,Air Cooled 65,000 Btu/h and 135,000 Btu/hElectric Resistance(or None)Single Package12.8 IEERAHRI 340/360Air Conditioners,Air Cooled 65,000 Btu/h and 135,000 Btu/hAll otherSingle Package12.6 IEERAHRI 340/360Air Conditioners,Air Cooled 135,000 Btu/h and 240,000 Btu/hElectric Resistance(or None)Single Package12.4 IEERAHRI 340/360Air Conditioners,Air Cooled 135,000 Btu/h and 240,000 Btu/hAll otherSingle Package12.2 IEERAHRI 340/360Air Conditioners,Air Cooled 240,000 Btu/h and 760,000 Btu/hElectric Resistance(or None)Single Package11.6 IEERAHRI 340/360Air Conditioners,Air Cooled 240,000 Btu/h and 760,000 Btu/hAll otherSingle Package11.4 IEERAHRI 340/360Air Conditioners,Air Cooled 760,000 Btu/hElectric Resistance(or None)Single Package11.2 IEERAHRI 340/360Air Conditioners,Air Cooled 760,000 Btu/hAll otherSingle Package11.0 IEERAHRI 340/360Air Conditioners,Air Cooled 65,000 Btu/hAllSplit System13.0 SEERAHRI 210/240Air Conditioners,Air Cooled 65,000 Btu/h and 135,000 Btu/hElectric Resistance(or None)Split System11.2 EERAHRI 340/360Air Conditioners,Air Cooled 65,000 Btu/h and 135,000 Btu/hAll otherSplit System11.0 EERAHRI 340/360Air Conditioners,Air Cooled 135,000 Btu/h and 240,000 Btu/hElectric Resistance(or None)Split System11.0 EERAHRI 340/360Air Conditioners,Air Cooled 135,000 Btu/h and 240,000 Btu/hAll otherSplit System10.8 EERAHRI 340/360Air Conditioners,Air Cooled 240,000 Btu/h and 760,000 Btu/hElectric Resistance(or None)Split System10.0 EERAHRI 340/360Air Conditioners,Air Cooled 240,000 Btu/h and 760,000 Btu/hAll otherSplit System9.8 EERAHRI 340/360Air Conditioners,Air Cooled 760,000 Btu/hElectric Resistance(or None)Split System9.7 EERAHRI 340/360Air Conditioners,Air Cooled 760,000 Btu/hAll otherSplit System9.5 EERAHRI 340/36015

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022Is the unit operation based on DX cooling?YesNoAre the proposed rooftop unit(s) intended for space cooling only?Heating Fuel Type:ElectricYesNoGasRooftop Unit Incentive CalculationEQUIPMENT TYPE INSTALLEDexample: rooftop unit #1EFFICIENCYOF UNITINSTALLED(SEER/IEER)HEATING TYPE:ELECTRIC,GAS OR NONE(A)UNIT SIZE(TONS)(B)NUMBEROF UNITSINSTALLED(C)INCENTIVEPER TONPER R/IEER)15Electric72 12.002.2(AxBxCxD)INCENTIVE 369.60 12.00 12.00 12.00 12.00 12.00 12.00 12.00INCENTIVE SUBTOTAL Energy Recovery VentilatorInstallation of Enthalpy Wheel: 0.20 per SCFMInstallation of Enthalpy Plate: 0.10 per SCFMInstallation of energy recovery equipment on existing or new unitary equipment.Design Air Flow ofEnergy RecoveryVentilator (SCFM):Specifications and Eligible Equipment1. Does not apply to wheel-type devices with purge sections, or to sensible-only devicessuch as heat pipes.2. Only applicable for healthcare, multifamily, office or retail facilities. Others may beeligible to receive incentives through Custom.Please select installation type:Enthalpy Wheel16Enthalpy PlateINCENTIVE SUBTOTAL:

HVAC AND VSD INCENTIVES WORKSHEETJanuary 1 through December 31, 2022High Efficiency Pumps and Pumping Efficiency Improvements (Retrofits) 15 per HPImprovement of pump efficiency to optimize the design and control of the current water pumping system. Dependingon the specifc application, possible options include slowing the pumping speed, trimming/replacing the impeller andreplacing the current pump with a more efficient pump.Specifications and Eligible Equipment1.2.3.4.Only water pumps are eligible for this measure.Only pumps up to 20 HP are eligible for this measure; larger HP motors may be eligible for custom incentives.Pumping efficiency must improve by a minimum of 15 percent.If a pump is to be replaced, the new pump must be rated at the same HP as the existing pump.APPLICATION DESCRIPTIONSIZE (HP)NUMBER INSTALLEDINCENTIVE SUBTOTAL GRAND TOTAL INCENTIVE REQUESTEDIncentive cannot exceed 100 percent of the incremental measure cost and 75 percent of the total project cost and mustmeet all program terms and conditions.Terms and conditions apply. Offers are subject to change.Actual savings will vary by customer’s energy usage and rate. Commonwealth Edison Company, 2022The ComEd Energy Efficiency Program is funded in compliance with state law.SHVACWS 110921–117

HVAC AND VSD INCENTIVES WORKSHEET. January 1 through December 31, 202. 2. 5. Variable Speed Drive on HVAC Chiller. 60 per ton. Variable-speed drives (VSDs) installed on an existing chiller (where applicable). Specifications. 1. The installation of a VSD must accompany the permanent removal or disabling of any throttling devices. 2. New .