TA-SCOPE - Reece Group

Transcription

TA-SCOPEInstrumentsBalancing instrument

IMI TA / Measuring tools / TA-SCOPETA-SCOPETA-SCOPE is a tough, effective balancing instrument for measuringand documenting of differential pressure, flow, temperature and powerin hydronic systems. Robust, accurate and easy-to-use, TA-SCOPEdelivers quicker, more cost-efficient balancing and enables rapidtroubleshooting. TA-SCOPE links effortlessly to the HySelect PCsoftware gaining the maximum benefit from recorded data andenabling professional report writing and automatic software upgrades.Technical descriptionFunctions:TA-SCOPE is a balancing instrument formeasuring and documenting of differentialpressure (Δp), flow, temperature andpower in hydronic systems.Measurement range:Total pressure:TA-SCOPE max. 1 600 kPaTA-SCOPE HP max. 2 500 kPaDifferential pressure:TA-SCOPE 0 - 500 kPaTA-SCOPE HP 0 - 1 000 kPaRecommended pressure range duringflow measurements:TA-SCOPE 1 - 500 kPaTA-SCOPE HP 3 - 1 000 kPaTemperature liquid mediummeasurement:-20 C – 120 CMeasurement deviation:Differential pressure:TA-SCOPE 0.1 kPa or 1% of reading,whichever is the highestTA-SCOPE HP 0.2 kPa or 1% of reading,whichever is the highestFlow: as for differential pressure valvedeviationTemperature: 0.2 C2Battery capacity, operating andcharge times:Handheld unit:- battery capacity: 4 400 mAh- operating time (with backlight on): 25 h- charge time to full capacity: 6-7 hDpS-Visio (Dp sensor unit):- battery capacity: 1 400 mAh- operating time (continuousmeasurements): 25 h- charge time to full capacity: 2.5 hLogging time (in sleep mode): 100 daysIngress protection:Handheld unit (in wireless mode): IP64Dp sensor unit (in wireless mode): IP64Safety pressure and temperature probe: IP65Digital temperature sensor: IP65Ambient temperature for theinstrument:During operation and charging: 0 – 40 CDuring storage*: -20 – 60 C*) Do not leave water in the sensor whenthere is a risk of freezing.Humidity:Ambient humidity: max. 90%RHCharger:Input voltage: 100-240 VACInput frequency: 50-60 HzConnectors: EU/UK/US/AUCase dimensions:TA-SCOPE Premium case:LxWxH 430x285x170 mmTA-SCOPE case:LxWxH 335x290x150 mm

ConstructionTA-SCOPE consists of two main components:Handheld unit – computer-based unit programmed with the TA valve characteristics. Straightforward functions with easy-to-followinstructions on the colour display.Differential Pressure Sensor unit – the DpS-Visio communicates wirelessly with the Handheld and has an OLED display forshowing its status, measured data and other information.TA-SCOPE automatically performs calibration when needed. The design of the sensor unit and a short flow-through duringcalibration eliminate measurement errors caused by insufficient venting of the measuring device.Hydronic functionsQuick MeasureStraightforward function to measure flow, differential pressure (Δp), temperature and power. To be used when onlyone or a few valves are of interest. The function does not require any predefinition of network or module.Hydronic NetworksComplex networks created in HySelect are easily downloaded to TA-SCOPE. Use a network for measuring andbalancing at any time; during commission, for control and inspection. All hydronic functions can be applied to aselected valve from a Hydronic Network.BalancingThe powerful TA-Wireless and TA-Diagnostic methods for balancing hydronic systems.TA-Wireless makes use of two Dp sensors with wireless technology to easily perform balancing of a hydronic module.With TA-Diagnostic, you measure all valves in a module. The method calculates a Dp diagnostic for the module andcorrect valve openings to attain design flows.TroubleshootingSoftware wizards take you step-by-step through the process of locating and diagnosing problems and errors inhydronic systems, e.g., Dp (Δp) analysis.Data LoggingMeasurement during a predetermined period of time to analyse any fluctuations in flow, differential pressure (Δp),temperature and power. The logged data is stored and listed or displayed as a graph, both in TA-SCOPE andHySelect.Support functionsFluidSettings of fluid in the system to be explored and diagnosed. Water is the most common fluid in hydronic systems butwater with various additives can also be handled by TA-SCOPE.Hydronic calculatorPerform calculations based on the relationship between flow, differential pressure (Δp), Kv value, power anddifferential temperature (ΔT). The function also gives guidance in selecting pipes and valves when designing hydronicsystems and enables unit conversions.SettingsManage adjustments regarding the instrument and appearance of information from the Settings function.InformationDisplays information like software version, last calibration and battery details on Handheld, Dp Sensor and alsoTemperature Sensor when connected.3

IMI TA / Measuring tools / TA-SCOPECase contentsTA-SCOPE PremiumTA-SCOPE Premium case is a larger robust partitioned case.Compared to the normal case, it includes:- Combined safety pressure and temperature probe allowingautomatic correction for fluid temperature and easier powermeasurement,- A large set of accessories,- Extra space for a second (optional) differential pressure sensorand tools.1. Handheld unit (Hh)2. Dp Sensor unit (DpS-Visio)3. Digital Temperature Sensor (DTS)4. Measuring hoses, 500 mm, red/blue5. Safety pressure and temperature probe (SPTP)6. Safety pressure probes (SPP)7. Measuring hoses with twin needle, 150 mm8. Flashlight9. Mirror10. Chucks for older valves, red/blue11. Allen Keys 3 mm/5 mm12. Spanner for measuring points on older valves13. Presetting tool TBV-C, -CM, (-CMP)14. Spare filters and O-rings for hoses (4 pcs)15. Chain for mounting16. Neckstrap17. Multi-charger for Handheld and Dp Sensor(s)(EU, UK, US, AU/NZ)18. USB cable for charging;Hh - Multi-charger19. USB cable for connection/charging;Hh - DpS-VisioPC - DpS-VisioDpS-Visio - Multi-charger20. USB cable for connection;Hh - PC21. Cable wrapping22. Case23. USB stick with user manual and HySelect software24. Calibration certificates for DpS-Visio, DTS and SPTP25. Quick Guide26. SPTP/SPP stickers27. Guarantee/Service/Calibration form4x421232425222627

TA-SCOPETA-SCOPE case is a robust partitioned case. It is smallerand contains a reduced set of accessories compared to thePremium case.1. Handheld unit (Hh)2. Dp Sensor unit (DpS-Visio)3. Digital Temperature Sensor (DTS)4. Measuring hoses with probe5. Multi-charger for Handheld and Dp Sensor(s)(EU, UK, US, AU/NZ)6. USB cable for charging;Hh - Multi-charger7. USB cable for connection/charging;Hh - DpS-VisioPC - DpS-VisioDpS-Visio - Multi-charger8. USB cable for connection;Hh - PC9. Allen Keys 3 mm/5 mm10. Presetting tool TBV-C, -CM, (-CMP)11. Spare filters and O-rings for hoses (4 pcs)12. Case13. Calibration certificates for DpS-Visio and DTS14. Quick Guide15. Guarantee/Service/Calibration formx4155

IMI TA / Measuring tools / TA-SCOPETA-SCOPE Premium / TA-SCOPE HP PremiumTA-SCOPE GermanyAustralia/New ZealandBelgiumCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeSwitzerlandDenmarkSpainFinlandFranceGreat BritainInternational versionItalyJapanKoreaLatin AmericaMiddle EastNetherlandsNorwaySouth AsiaSwedenTurkeyUSAChina (simplified Chinese)Taiwan (traditional Chinese)EANArticle 101731879400120652 199-00652 199-02352 199-02452 199-01052 199-01152 199-01252 199-01352 199-02552 199-02252 199-00352 199-00952 199-00552 199-00752 199-01552 199-00252 199-02152 199-01652 199-02652 199-01852 199-01752 199-00852 199-00452 199-01952 199-00152 199-02752 199-01452 199-02052 199-029*) Version Market related product range. All instrument versions include all of the above languages.QuickGuide included. User manual available on USB stick.6

TA-SCOPE HP GermanyAustralia/New ZealandBelgiumCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeSwitzerlandDenmarkSpainFinlandFranceGreat BritainInternational versionItalyJapanKoreaLatin AmericaMiddle EastNetherlandsNorwaySouth AsiaSwedenTurkeyUSAChina (simplified Chinese)Taiwan (traditional Chinese)EANArticle 109731879400130552 199-10652 199-12352 199-12452 199-11052 199-11152 199-11252 199-11352 199-12552 199-12252 199-10352 199-10952 199-10552 199-10752 199-11552 199-10252 199-12152 199-11652 199-12652 199-11852 199-11752 199-10852 199-10452 199-11952 199-10152 199-12752 199-11452 199-12052 199-129*) Version Market related product range. All instrument versions include all of the above languages.QuickGuide included. User manual available on USB stick.7

IMI TA / Measuring tools / TA-SCOPETA-SCOPE / TA-SCOPE ia/GermanyAustralia/New ZealandBelgiumCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeSwitzerlandDenmarkSpainFinlandFranceGreat BritainInternational versionItalyJapanKoreaLatin AmericaMiddle EastNetherlandsNorwaySouth AsiaSwedenTurkeyUSAChina (simplified Chinese)Taiwan (traditional Chinese)EANArticle 509731879401030752 199-20652 199-22352 199-22452 199-21052 199-21152 199-21252 199-21352 199-22552 199-22252 199-20352 199-20952 199-20552 199-20752 199-21552 199-20252 199-22152 199-21652 199-22652 199-21852 199-21752 199-20852 199-20452 199-21952 199-20152 199-22752 199-21452 199-22052 199-229*) Version Market related product range. All instrument versions include all of the above languages.QuickGuide included. User manual available for download on www.imi-hydronic.com.8

TA-SCOPE nyAustralia/New ZealandBelgiumCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeCentral Eastern EuropeSwitzerlandDenmarkSpainFinlandFranceGreat BritainInternational versionItalyJapanKoreaLatin AmericaMiddle EastNetherlandsNorwaySouth AsiaSwedenTurkeyUSAChina (simplified Chinese)Taiwan (traditional Chinese)EANArticle 304731879401210352 199-30652 199-32352 199-32452 199-31052 199-31152 199-31252 199-31352 199-32552 199-32252 199-30352 199-30952 199-30552 199-30752 199-31552 199-30252 199-32152 199-31652 199-32652 199-31852 199-31752 199-30852 199-30452 199-31952 199-30152 199-32752 199-31452 199-32052 199-329*) Version Market related product range. All instrument versions include all of the above languages.QuickGuide included. User manual available for download on www.imi-hydronic.com.9

IMI TA / Measuring tools / TA-SCOPEAdditional equipmentDp sensor unit (DpS-Visio)The handheld unit (Hh) can communicatewith several Dp sensor units (DpS-Visio).Establish communication by connectingthe cable (included in the TA-SCOPEcase) between the handheld unit and theDp sensor unit.Included: 2 measuring hoses 500 mm,2 identification rings, 2 safety pressureprobes (SPP) and 1 charging cable.Measuring hoseFor use with SPP and SPTPVersionEANArticle No7318794034204731879403430352 199-97152 199-972EANArticle No7318793998507731879399860652 199-95352 199-954Length [mm]EANArticle No150731879398590352 199-999EANArticle No731879399830952 199-951EANArticle No731879399840852 199-952EANArticle NoStandardHP (highpressure)0-500 kPa0-1000 kPaLength [mm]500500RedBlueMeasuring hose with twin needleSafety pressure probe (SPP)For use with measuring hoses52 199-953/-954 and extended hoses52 199-997/-998.Safety pressure and temperature probe (SPTP)For use with measuring hoses52 199-953/-954 and extended hoses52 199-997/-998.Cable wrappingTo keep SPTP cable and hose together310 355-01Digital temperature sensor (DTS)10EANArticle No731879398350352 199-941

AccessoriesMeasuring hoseWith shut-off valveLength [m]EANArticle 580452 199-99552 199-99652 199-99752 199-998EANArticle No73187940449067318794045002311 074-61311 074-60EANArticle No73187937413017318794044807309 206-01311 062-62Length [m]EANArticle No5731879398540852 199-9940.50.533RedBlueRedBlueMeasuring hose with measuring needle, angleHose and needle can’t be disconnected.Length [m]0.50.5 09.2018RedBlueFilterSpare part to measuring hoses 09.201810.2018 10.2018 1 pc4 pcExtension cable for digital temperatur sensorMeasuring nippleThread connections G1/2 and G3/4Measuring nippleExtension 60 mmCan be installed without draining of thesystem.EANArticle NoG1/2G3/47318793536808731879353690752 197-30352 197-304LEANArticle No60731879281280452 179-006EANArticle No7318793787507307 635-62EANArticle No73187937866097318793786708309 748-60309 748-61Measuring needle, angleChucksFor older valves and TA-BVSRedBlue11

IMI TA / Measuring tools / TA-SCOPEABCIdentification rings“DpS 1” and “DpS 2” for marking theDpS-Visio when using TA-Wireless.To be placed on measuring hoses.DpS 1DpS 2Multi-chargerWith 4 USB plugs.Excl. charging cables.EU, UK, AU, USEANArticle No310 399-01310 399-02EANCablesTo connect or charging different devicesArticle No311 100-01EANCabel AHandheld - Multi-chargerCabel BHandheld - DpS-Visio /PC - DpS-Visio /DpS-Visio - Multi-chargerCabel CHandheld - PC /Handheld - DpS (up to08.2017)Article No310 397-027318794045101310 278-027318793996305310 278-01The products, texts, photographs, graphics and diagrams in this document may be subject toalteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most upto date information about our products and specifications, please visit www.imi-hydronic.com.7-5-6 TA-SCOPE ed.5 06.2019

Hh - PC 9. Allen Keys 3 mm/5 mm 10. Presetting tool TBV-C, -CM, (-CMP) 11. Spare filters and O-rings for hoses (4 pcs) 12. Case 13. Calibration certificates for DpS-Visio and DTS . NO Norway 7318793987501 52 199-104 SAS South Asia 7318793989000 52 199-119 SE Sweden 7318793987303 52 199-101 TR Turkey 7318793999900 52 199-127