AlcolyzerBeer Analyzing System::: Unique Density & Concentration Meters

Highly AccurateResults for all BeersThe Alcolyzer Beer Analyzing System is the successor ofthe Alcolyzer Plus Beer Analyzing System. It consists of anAlcolyzer Beer ME module, DMA M density meter andXsample 122 sample changer or Xsample 22 filling unit.The system measures all types of beers, including non-alcoholicbeers, beer mixtures, RTD (ready to drink) alcoholic beverages,fermenting beers, and also cider and molasses (bioethanol). Thepatented near infrared (NIR) measuring method (US 6,690,015,AT 406711) of the Alcolyzer Beer ME module eliminatesthe influence of other sample ingredients on the alcoholmeasurement, therefore guaranteeing highly accurate results.The Xsample 122 sample changer automatically fills up to24 samples into the measuring system. For routine work, theDMA 4500 M density meter is the right choice. DMA 5000 M issuitable for research work due to its even higher accuracy. Thewhole system is operated via a touchscreen on the DMA Mmaster instrument.One Sample - All ParametersThe Alcolyzer Beer Analyzing System determines the alcoholcontent, and further parameters such as density, originalextract, real extract, degree of fermentation, calorie contentand optionally also color, viscosity, pH and turbidity - all in onemeasuring cycle, all from one single sample.The modular concept enables the easiest and most reliablemeasurements and adjustments. You always have the option toupgrade your system step-by-step by adding all the parametersyou need - now and in the future.Equipped for the futureAnton Paar has longstanding experience in the brewing industryand works closely with customers to meet their needs. Teamsof researchers are dedicated to improving existing Anton Paarproducts and developing new ones. This means you will benefitfrom your Alcolyzer Beer Analyzing System as an innovative andmodular product for many years to come.

Standardized, Accurateand Easy to UseThe heart of the system is the patented, selectivealcohol measurement: A narrow, highly alcohol-specificrange of the NIR spectrum is evaluated with a speciallydeveloped, highly stable high-resolution spectrometerand suitable algorithms.In this particular spectral range the influence of otherbeer ingredients is so small that Alcolyzer Beer MEobtains extremely accurate alcohol results. Due to itsselectivity and linearity, the measuring method onlyrequires adjustment with water and an alcohol/watersolution. One single adjustment is valid for all sampletypes. The time and work required for adjustment istherefore minimal.The measuring method has been checked andapproved by MEBAK and corresponds to the EBCand ASBC standards.User-friendlyAll Anton Paar's Generation M instruments providehighly reliable measurement combined with state-of-theart features. You can connect USB instruments such asa keyboard, mouse, printer, bar code reader or externaltouchscreen.The Alcolyzer Beer Analyzing System has a LIMSconnection. Data can be exported via a USB flashdrive, printer, RS-232 or Ethernet (LAN); reports can becreated in common formats such as PDF, TXT and XLS.Each user logs on to a defined user level anddocuments work steps as required. The special featuresof DMA M (U-ViewTM, FillingCheckTM) ensure traceabledocumentation. Sources of error are recognized early.

EverythingUnder ControlA new generation asthe master4 DMA M as the master instrument4 Full control: U-View ,FillingCheck , ThermoBalanceTM4 User interface in more than 10languages including Chinese andJapaneseSo easy44444Fully automatic sample changerEasy adjustmentPractically maintenance-freeSecure due to different user levelsLIMS connectionEverything covered4 All standards: MEBAK, EBCand ASBC4 Methods for alcohol measurementwhen manufacturing bioethanol(molasses) and whisky (wash)More at any time4444Color, pH, viscosity and turbidityBar code readerCO2 and O2Xsample 510 automated packagesampler for glass bottles, PETbottles and cans

Technical DataMeasuring rangeAlcohol content0 %v/v to 12 %v/vOriginal extract0 Plato to 30 PlatoExtract content0 %w/w to 20 %w/wDensity0 g/cm3 to 3 g/cm3Color (optional)0 EBC to 120 EBCpH (optional)0 pH to 14 pHViscosity (optional)0.3 mPa.s to 10.000 mPa.sTurbidity (optional)0 EBC to 100 EBC(values up 200 EBC are displayed)Repeatability s.d.Alcohol content0.01 %v/vOriginal extract0.03 PlatoExtract content0.01 %w/wDensity0.00001 g/cm3 (DMA 4500 M)0.000001 g/cm3 (DMA 5000 M)Temperature controlTemperature control, turbiditySample volumeColor (optional)0.1 EBCpH (optional)0.02 pH (in the range 3 pH to 7 pH)Viscosity (optional)0.1 %Turbidity (optional)0.02 EBCIntegrated Peltier thermostat0.01 C Repeatability s.d. in the range -5 C to 40 Capprox. 30 mL degassed sample per measurementTypical measuring duration per sampleapprox. 4 minutes (incl. filling)Sample throughputapprox. 15 samples per hourDimensions (L x W x H)482 mm x 730 mm x 446 mm(19 in x 28.7 in x 17.6 in)WeightPower supplyInterfaces35.7 kg (78.7 lbs)AC 100 to 240 V; 50 to 60 Hz; 50 to 80 VA4 x USB, Ethernet, VGA, CAN, RS-232

Subject to change without notice01/14 C83IP001EN-D

DMA 4500 M density meter is the right choice. DMA 5000 M is suitable for research work due to its even higher accuracy. The whole system is operated via a touchscreen on the DMA M master instrument. One Sample - All Parameters The Alcolyzer Beer Analyzing System determines the alcohol content, and further parameters such as density, original