Geberit Assisted Toilet Pre-Installation Instructions

Transcription

SafetyTarget groupThe Geberit product is only to be installedby a qualified installer in accordance withthe installation instructions and thecurrent safety regulations.Geberit Assisted ToiletPre-Installation InstructionsProper useThePre-InstallGeberit AquaClean8000plus Care isInstructionsdesigned for cleaning the anal and vaginalPlease see the below for instructions to prepare site for installation.area.It may only be used as a complete solution.All electrical connections are to be carried out by a qualified electrician. AC Power to be tested andavailable in advance of OpeMed engineers arrival. All flooring must be level and complete. All walls mustDANGERbe decorated and complete.Electric shock hazardSHThe device may only be operated atpower outlets or fixed connections5 this height, proceed to step B.Information: The factory setting for the seat height is 445 mm. If you wish 40to5–52usewithprotectiveearthing.If thecustomerwishesthe seat height to be different from the factory setting, proceed to step A.SHSH40 5–52 544 5Installation dimensionsSH230 VESD44 5 30mm3Please note:0mm 8877m 55660m90m9m8mm8022140m0m0m 44Cold water supply can be placed anywhere in the specifiedarea.16dFuserusp20m0m 443{Fuse Spur can be installed outside of the toilet. Please note,distance is limited as there is only 700mm flex (see pages 3 - 5).We recommend placing the Fuse Spur above or tothe side of the cold water supply or to use awaterproof connector under the toilet and extend theflex to the outside of the bathroom or elsewhere to theFuse Spur.!If the soil / waste pipe is positioned through floor, ensure140mm from centre of pipe to wall (see page 2). Waste pipecan be 90mm or 110mm.mD58137-003 09-2015964.812.00.0 (05)Clockhouse, Dogflud Way,Farnham, Surrey - GU9 7UDwww.opemed.net101252 758 858info@opemed.net

Waste PIpe:The Diagram below shows the positioning of the waste outlet.ø 12 mm420010 1ø 12 mmø 12 mm20220440 100110 122Determine the height ofthe outlet pipe withthe seat height: Select the appropriatedimension for Y depending on the set frameheight.Determine the1 height ofthe outlet pipe withDetermine the height of the outlet pipe withthe seat height:8 Select the appropriatethe seat height: Select the appropriateSH Ydimension for Y depending on the set framedimension for Y depending on the40set5 frame21height.height.1188x8)xxD 14 15 16 17 18 19 20 21) 9 12 9 11 8 10 7 96X 17 2 16 4 41513–285D (1D 22 23 24 25 26 27 285 64 54 43 32 21X 148 6 715D16 17 18 19 20 21D 14 15 16 17 18 19 20 21249 812 97 118 7 62 16 4169 11159 121315 1310 96 10 9XX 171755A27 2832 2133Clockhouse, Dogflud Way,Farnham, Surrey - GU9 7UDD58137-001 10-2012964.812.00.0 (03)AAwww.opemed.net2YY814-2D (14–28)D24 2528D 222223 2324262527 26X 8 6 675 654 544 43 432 231X 8 7 6 5 4Y814-2–2D (143ENOnly for sideways soil connection: OutletOnly for sideways soil connection: Outletbend can also be fitted in a Left or Rightbend can also be fitted in a Left or Rightposition.position.111Only for sideways soil connection: Outletbend can also be fitted in a Left or Rightposition.42 544 5546SHH55484038555504240555524442 546 554448 554650 554852 AA01252 758 858info@opemed.net5

Electrical Connection:-The Geberit AquaClean requires a 5amp 230V AC 50Hz power supply. The powerconnection must be made in an area that is kept free from moisture or connected via aIPX4 waterproof socket with isolation switch be decorated and complete.The Diagram below shows the recommended positioning of the IP rated fuse spur.The electrical connection of Geberit AquaClean may only be installed by skilledpersons in accordance with the local regulations.The following recommendations apply according to DIN VDE 0100-701:2008-10.The country-speciÞc conditions for Austria and Switzerland are taken into accounttherein.Installation in rooms with bath tub or shower tray- The Geberit AquaClean models correspond to protection degree IPX4 and mayonlybe installed outside of the edge of the tub or tray. Please Note: The followingmeasurements are in Centimeters (cm)60606060Protection area around the bath tubProtection area around the shower tray1. Hidden connectionIPX4a) with unswitched fused spurClockhouse, Dogflud Way,Farnham, Surrey - GU9 7UDb) with Þxed connection via junction box(at least IPX4, Geberit AquaClean may be closerthan 60 cm to the edge of the tub or tray)www.opemed.net301252 758 858info@opemed.net

2. Visible connectionfusespudrfusespudrGeberit AquaClean complete solutionGeberit AquaClean enhancement solutionInstallation in rooms with showers without tray- The power outlet has to be installed outside the protection area.120120120120120120Protection area around the shower without tray(with(with Þxedfixed showershower head)head)³ 120 cmProtection area around the shower without tray(with(with ßexibleflexible hose)hose)³ 120 cmfusespudrGeberit AquaClean complete solutionClockhouse, Dogflud Way,Farnham, Surrey - GU9 7UDfusespudrGeberit AquaClean enhancement solutionwww.opemed.net401252 758 858info@opemed.net

Geberit AquaClean in the protective areaApproach: Construct a Þxed shower partition with a height of 225 cm between shower andWC system. This will mean that the WC system is outside the protective area.Non-conforming installation of the Geberit AquaClean models will then be possible.120120* In the case of shower partitions with heights less than 225 ontal (encompassing radius) and vertical (thread measure) direction must be maintained.120³ 120120³ 120225*a) Minimum distance, horizontalClockhouse, Dogflud Way,Farnham, Surrey - GU9 7UDb) Minimum distance, verticalwww.opemed.net501252 758 858info@opemed.net

Product data sheetTechnical dataProtection classIProtection degreeIPX4Nominal voltage230 V ACMains frequency50-60 HzPower consumption1000 WPower consumption standby / with heating switchedon1/9 WCable length0.7 mFlow pressure 1-10 bar1 barOperating temperature10-40 ¡ CWater temperature, adjustment range10-39 ¡ CWater temperature, factory setting37 ¡CDryer temperature, factory setting45 ¡CFlush volume, factory setting 6and 3 l0.13 l/sSpray time 20sMaximum load WC seat150 kgScope of deliveryWater supply connection set with angle stop valve, reinforced braided hose and screw connectionSpray shieldNozzle cleaner, 400 mlCleaning setConnection set for WC, ¿9 0 mmCover plate for remote control compartmen tRemote control with LC display, wall-mounted case and batteries, LR03 (AAA )Fastening materialArticleArt. no.Colour / Surface185.200.11.1white alpineThis product is supplied with the Geberit AquaClean nozzle cleaner and the GeberitInformation, instructions and measures for handling hazardous substances safely can befound in the appendix or at www.geberit.co.uk .AccessoriesAccessory overview: Water supply and electrical connection for Geberit concealed cisternsClockhouse, Dogflud Way,Farnham, Surrey - GU9 7UDwww.opemed.net601252 758 858info@opemed.net

Geberit Assisted Toilet Pre-Installation Instructions www.opemed.net Clockhouse, Dogflud Way, Farnham, Surrey - GU9 7UD 01252 758 858 1 info@opemed.net Cold water supply can be placed anywhere in the specified area. Please note: If the soil / waste pipe is positioned through floor, ensure 140mm from centre of pipe to wall (see page 2). Waste pipe