UV-VIS Spectrophotometer UV-2600i UV-2700i - Shimadzu

Transcription

C101-E169UV-VIS SpectrophotometerUV-2600iUV-2700i

D o n’t M iss Any P ieceo f t he Pu zzleUV-i SelectionUV-1900iUV-2600i/2700iUV-3600i PlusSolidSpec -3700i

Perfect for a Wide Variety of ApplicationsS pe ctral eval u ati o n fu n c ti o n e na ble s unique pa ss/ f a il judgm e nt f or qua lit y co n tro l .D ur ing m e a s u remen ts , d ata c an b e aut om a t ica lly se nt t o E x ce l in r e a l t im e f or using mac ro st o a ut om a t ica lly obt a in de sir e d val u es .Measures Slight Differences in AbsorbanceS ca la bilit y t o ne a r -inf r a r e d m e a suremen t.U lt ra-l o w s tray l i g h t en able s m e a sur e m e nt s dow n t o a bsor ba nce v a lue s of 8 Ab s .Enables Compliance with ER/ES Regulations and Stronger Data Management.Conf igur a ble a s sy st e m f or pr e v e nt ing da t a t a mp eri n g .E f f i c i en tl y p reven ts d ata tam pe r ing f r om e nt ir e se r ie s of a na ly t ica l pr oce s s s tep s .

Single monochromator UV-2600iDouble monochromator UV-2700iExtensive Selection of Application Programsfor a Wide Variety of ApplicationsThe functionality of the UV-2600i / 2700i can be freely expanded to suit the measurement objective. By accommodating a wealth ofaccessories, the system can address any user’s applications and a variety of situations. In addition, with intuitive operations, anyone caneasily obtain the data required.UV-2600i UV-2700iEnvironmentElectricity, Electronics, and OpticsHigh-level absorbance measurements for polarization filmsUV-2600i UV-2700iFEHexavalent chromium quantitationFEQuantitation of total phosphorus and total nitrogenin river water, lakes, and marshesFETurbidity measurementsEFQuantitation of iron, copper, arsenic, ammonia,and other substances in waterFETransmittance measurementsfor window glass and window glass filmsEFReflectance measurements for paints and building materialsEFEFAbsolute reflectance measurements for anti-reflective filmsEFTransmittance measurements for functional filmsEETransmittance measurements for solar cell cover glassEFBand gap measurements and diffuse reflectancemeasurements for semiconductor materialsEFAbsolute reflectance measurements for highly reflective mirrorsEFChemicalsTransmittance and reflectance measurementsfor various types of filmsEThin film thickness measurementsEEPlastic transmittance measurements,reflectance measurements, and color measurementsEFFMedicines, Cosmetics, and the Life SciencesRaw material confirmation testsEEEnzyme reaction measurementsEEProtein and nucleic acid quantitationFECosmetic color measurementsand ultraviolet screening measurementsEFEvaluation of optical properties of nanoparticlesEFConstructionTextilesTextile transmittance and reflectance measurements,and ultraviolet screening measurementsTextile color measurementsEFEvaluation of cellulose nanofibers (CNF)EFQuantitation of vitamins, food additives, and mineralsFEQuantitation of phenolsleached from containers and packing agentsFEFoodsE: excellent F: fairA ut om at e d D a t a P r o c e s s i n gAfter spectra are measured, data processing can be performed andresults displayed automatically according to a customized evaluationmethod. Multiple evaluation criteria can be configured.The method used to calculate evaluation values can be selected from a variety of 33 standardevaluation methods (arithmetic calculations, peak/valley, area, or statistical calculations) or customized.Pass/fail criteria can also be selected from eight types (such as pass if greater than or equal to, lessthan or equal to, greater than, or less than a specified value).4PreviousLabSolutions UV-VisChecked/decided by lookingat peak values or spectra.Decided by softwarebased on data.By specifying various evaluationcriteria for measurement results,spectra judgments can be madeautomatically.123SampleMeasures anddetermines pass/fail resultat the same time.123FAIL PASS PASS

Electricity, Electronics,and OpticsBand Gap Measurements forSemiconductorsConstructionWindow Glass TransmittanceMeasurementsThe diffuse reflection spectra for two types of semiconductors (red line:Two types of window glass were measured utilizing the ISR-2600PlusCuln0.5Ga0.5Se2, blue line: CulnSe2) used as solar cell materials have beenintegrating sphere. The sample shown by the red line is highlymeasured using the ISR-2600Plus integrating sphere. It is evident that thetransparent to near-infrared light at 800 nm or more.absorption edge (position where the reflectance drops) differs dependingon the sample. This difference signifies a difference in the band gap* forThe sample shown by the blue line, however, is apparently not verytransparent to near-infrared light.these samples. (The samples were provided by Wada Laboratory, Facultyof Science and Technology, Ryukoku University.)The band gaps for the samples were calculated utilizing the Taucmethod. The results obtained were 1.27 eV for Culn0.5Ga0.5Se2 (red line)and 0.99 eV for CulnSe2 (blue line).* The term band gap refers to the energy difference between the top of the valenceband, which is full of electrons, and the bottom of the conduction band, which doesnot contain electrons.ChemicalsThickness Measurements of Cling FilmsTextilesEvaluation of CNFUndulating interference waveforms sometimes occur if light is passedAn ISR-2600Plus integrating sphere was used to measure the totalthrough a film. The film thickness of a sample can be determined bytransmittance spectrum of cellulose nanofiber (CNF). Depending on theusing these interference waveforms. The black line shows transmittanceraw materials used, spectra can vary, transparency can vary, and spectraldata for polyvinylidene chloride film, the red line for nylon film, and thetendencies in the ultraviolet region can vary.blue line for polypropylene film.By using the optional thickness calculation software, the interferencewaveforms were calculated to be 10.0 μm, 17.0 μm, and 21.4 μm,Transmittancerespectively.(Caution) The sample’s refractive index must be entered for the film thicknesscalculation.WavelengthLife SciencesDNA and Protein MeasurementsFoodsVitamin MeasurementsThe red and blue lines are the absorption spectra for dsDNA and BSAThis shows the absorption spectra for riboflavin (vitamin B2). The sample(bovine serum albumin), respectively. The concentration values are 45concentrations are, in order from the highest absorbance, 0.08, 0.04,ng/μL for dsDNA and 2.2 mg/mL for BSA.0.02, and 0.01 mg/mL.UV-2600i/UV-2700iUV-VIS Spectrophotometer5

Single monochromator UV-2600iScalability to near-infrared measurementA key feature of the UV-2600i single monochromator system is its measurement wavelength range.By using the optional ISR-2600Plus Integrating Sphere attachment, the measurement wavelengthrange can be extended from 220 nm to 1400 nm, significantly expanding its applications.Integrating Sphere EnablesMeasurements to 1400 nmWider Measurement Wavelength RangeU V - 2 6 0 0iThe UV-2600i is also equipped with Shimadzu’s proprietary185Lo-Ray-Ligh grade diffraction grating, which achieves high900 nmefficiency and low stray light levels. By installing the ISR-2600PlusUV-2600i ISR-2600Plustwo-detector integrating sphere, the 300 nm to 1100 nmwavelength range of conventional models can be extended toU V- 2 6 0 0 i2201400 nm1400 nm. In addition, the UV-2600i achieves a significant noisereduction, and can accommodate measurements of solar cellanti-reflective films and polycrystalline silicon wafers.Tr a nsm it t a nce M eas ur em ent s of Pol yc r ys t al li n e S i l i co n U si n g th e I S R - 2 6 0 0 P l u s50.0U V- 2 6 0 0 iMirror M3MaskRef. light40.030.0T%Mirror M220.090 8 Mask10.00.0500.0 600.060 mm dia.integrating sphere800.01000.0nm1200.01400.0This is a transmittance measurement of polycrystalline silicon.Since the system is capable of measurements to 1400 nm, thetransmission characteristics of the band gap region (near 1000 nm)are clearly evident.6ISR-2600Plus Integrating Sphere AttachmentSample lightMirror M1

Tr ansm it t ance/ R ef l ec t anc e M eas ur em ent s of Mu l ti l a y e r D i e l e ctri c F i l m W h i l e V a ry i n gAngle of Inciden c e Us i ng Var i abl e Angl e M ea su re me n t U n i t fo r MP C - 2 6 0 0 AIncident angleBlack: 0 Red: 5 Blue: 12 Green: 30 Violet: 45 Variable Angle Measurement UnitU V- 2 6 0 0 iIncident angleRed: 5 Blue: 12 Green: 30 Violet: 45 These measurement results from a multilayer dielectric film show the transmittance onthe left and reflectance on the right.The results confirm that varying the incident angle changes the center wavelength oftransmitted and reflected light.UV-2600i/UV-2700iUV-VIS Spectrophotometer7

Lo-Ray-Ligh gradediffraction gratingAchieves Ultra-Low Stray Light,Enabling 8 Abs MeasurementsA b so rb a n ce L i n e a ri tyU V- 2 7 0 0 iCalibration Curve9.08.0In the case of a device equipped with a general double monochroma6.0Abs.tor, the absorbance that can be covered is about 5 to 6, but theUV-2700i offers a range to 8 Abs, with a transmittance value of0.000001 % (1 part in 100 million). This system achieves high-level4.02.0absorbance measurements with incomparable precision. In addition tomeasuring even high-concentration samples as is, eliminating the need0.00130260390520Concentration (mg/L)to dilute samples, the system can be applied to evaluating the transmis-This shows the relationship between the absorbance and theconcentration of an aqueous potassium permanganate solution.Good linearity is evident to 8 Abs.sion characteristics of polarization films. Wavelengths in the 400 nm to650 nm range can be measured to 8 Abs.9.09.08.08.06.06.0Abs.Abs.Spe ct r al Com pari s on of Aqueous Pot as s i um P e rma n g a n a te S o l u ti o n s4.0500.0nmUV-2700i84.02.02.00.0400.0U V- 2 7 0 0 i600.0700.00.0400.0500.0nm600.0700.0General double monochromator system

Double monochromator UV-2700iMeasures Slight Differences inAbsorbanceEquipped with a double monochromator that achieves ultra-low stray lightlevels, the UV-2700i is optimal for measuring low transmittance samples, suchas polarization films used for LCD panels. The UV-2700i is capable of 8 Absmeasurements, and can make accurate transmittance measurements to 1 partin 100 million, accommodating a variety of sample measurements.Exa m ple of P ola r i z at i on F i l m M eas ur em ent6.000UV-2700iWith the rotating film holder(photograph below), two filmEquipped with Shimadzu's ProprietaryLo-Ray-Ligh Grade Diffraction Gratingsamples can be set on the sameAbs.4.0002.000optical axis. In this example, theShimadzu's proprietary Lo-Ray-Ligh grade diffractionpolarization film is rotated in thegrating enables the high precision of theplane, and the transmittance isUV-2600i/2700i. In the diffraction grating productionmeasured when the film transmitsprocess, new proprietary manufacturing methodsand blocks light.have been developed for Shimadzu's holographictechnology. By optimizing the etching process, wehave successfully manufactured extremely low straylight diffraction gratings while maintaining y. With this newly designed optical systemequipped with a doubleLo-Ray-Ligh monochromator,the UV-2700i achievesunparalleled ultra-lowstray light levels.Rotating film holder (optional)UV-2600i/UV-2700iUV-VIS Spectrophotometer9

Enables Compliance with ER/ES Regulations andStronger Data ManagementLabSolutions UV-Vis SoftwareEnables higher productivity and provides for a more convenient analytical environment.Setting ParametersS m oot h Ope rabilityFrom Measurement to Data OutputFo u r M eas u rem e n t Mo d e sI m p r o v e d P r o d u ct i v i t y o fDa t a An a l y si s O p e r a t i o n sFour separate measurement modes: spectral, quantitative,Data analysis and data output operations can be performed at thephotometric, time-course, automatic measurement (optional)same time (simultaneously) as data measurement. Time spentenable measurements to be performed using intuitiveoutputting or analyzing data can also be reduced by simultaneouslyoperations.sending data to an Excel spreadsheet in real time or saving data astext. The software can also automatically perform post-processing ofmeasured data, such as processing/correcting spectra, and performpass/fail judgments of measurement results (automatic spectralevaluation).Instrument parameter settings can be specified via panels that areseparate from the measurement window. The control panelsFinish measurementIn s tru men t C on t r o l P a n e lStart measurementFour Measurement Mode Windowsinclude various functionality that is laid out for superior visibility.sponding parameter settings window.Finish measurementsfor multiple samplesEach measurement window connects seamlessly to the corre-Analyze data in Excel concuconcurrentlyently with data measurement(Excel data analysis real-time transfer function)Also easily transfer data to external data analysis software(simultaneous text saving and matrix output functions)10

Data ManagementAutomatic Spectral Evaluation(Spectral Evaluation Function)S t r o n g e r Da t a Ma n a g e m e n tBy specifying various evaluation criteria for measurement results,ideal solutions for saving data in a database with sophisti-spectra judgments can be made automatically.cated security functionality and compliance with ER/ES-re-In addition to regular file management in folders on a PC,lated regulations are also available (optional LabSolutionsDB UV-Vis and LabSolutions CS UV-Vis software).D at abas e M anagem entManaging data in a database can prevent the overwritingor deletion of analysis data. Furthermore, during postrunanalysis, the data can be managed using version numbers,so there are no concerns about overwriting the data.PostrunanalysisAnalysisVer. 1PostrunanalysisVer. 2Ver. 3R e d u ce s o p e ra to r e r r or s .V alidat ion Sof t w ar eEquipment performance can be easily checked in dailyinspections and when data accuracy becomes a concern. TheIn the report creation window, reports can either be prepared baseduser can select confirmation of instrument performanceon a previously specified report format or freely laid out based onindicators as per JIS K0115 General rules for molecularvarious parameters, data, or other elements.absorptiometric analysis, as well as the general test methods inthe Japanese Pharmacopeia and various EP and USPinspections. (Order inspection jigs and reagents separately.)UV-2600i/UV-2700iUV-VIS Spectrophotometer11

Stronger Data ManagementComprehensive DataIntegrity ComplianceThe system enables full compliance with data integrityrequirements, not only for chromatography equipment,but also UV-VIS spectrophotometers and other spectralanalysis instruments.LabSolutions CS/DB UV-Vis provides compliance for regulations concerning electronic record keeping and electronic signatures requiredby FDA 21 CFR Part 11 and other regulations stipulated by Japan’s Ministry of Health, Labour and Welfare (ER/ES regulations). Additionally, since the software supports laboratory networking, analytical results from a broad variety of analytical instruments used in thelaboratory, including LC, LCMS, GC, GCMS, ICPMS, FTIR, RF, EDX, TOC, and PPSQ and so on, can be managed centrally from a server.Client PC*23iPad *Laboratory or officeLabSolutions server1Acquisition *controller PCLCGCGCMSLCMSICPMSAAUVFTIRTOCRFThermal PPSQ Balance Agilent LC Agilent GCanalyzerPowder andparticle size analyzerEDXCombine with Multi-Data Registration license to enable integrated management of these instruments’ data.CBM-201m Other VendorLC/GCFile acquisition capableNetwork System: LabSolutions CSLabSolutions CS can freely access all instruments on the analytical network, so that all analytical data is managed on the network serverand the data can be loaded to any computer connected to the network. This is especially recommended for customers that have manyusers and want to manage data on a server together with LC, GC, FTIR, UV, RF, EDX, TOC, PPSQ, and other data for ER/ES compliance.Standalone Database System: LabSolutions DBThis configuration does not require a network connection and is ideal for customers that want to manage all data on one computerfor ER/ES compliance only.*1 The acquisition control PC controls analytical instruments. It can also be used to send analytical instructions and perform postrun analysis, just like a client PC.*2 If a terminal service is used, then LabSolutions software does not need to be installed on client PCs.*3 If an iPad is used, then XenApp from Citrix must be installed.12

Pe r t inent In forma tion isM a n a g e d f o r Eve r y P r o j e c tManagement can be suited to tasks!Project ALabSolutions DB UV-Vis and CS UV-Vis provide a projectLabSolutionsservermanagement function enabling management suited toProject Btasks and system operations. This function enablesequipment and user management, security policy, andProjectdata processing to be set on a project by project basis,Access OKAdatathereby improving the efficiency of data searches andProjectBmanagement tasks.dataAccess OKAuthorizationOnly shows data related to the project for more convenient data searching.Visualizat ion of a S e rie s of Analy si s O p e r a t i o n sCreating a report set* provides visibility of the individual analyticaloperations involved in the overall analytical process. When analyticaloperations are visible, it is easier to check for operating errors, whichhelps improve the efficiency and reliability of checking processes.Sample information* Report sets include test methods and test results for a series of samples analyzed,and also a corresponding operation log (a record of all operating events from loginto logout), which is automatically extracted from the data and summarized in asingle report.Analysis reportReport Set*Operation historyAnalysis condition Data historyData FileAnalysis SequenceOptionalEnsuring data integrity requires a system that shows no data manipulation has occurred. Shimadzu has achieved this through the introduction ofits Analysis Sequence for spectrometers. Using the Analysis Sequence, it is possible to verify that the full chain of analysis has been carried outaccording to an experimental protocol (or SOP).The LabSolutions Analysis Sequence (optional) provides a three-step workflow:1. A sequence is put together according to a given experimental protocol (or SOP). See the flow below for reference.2. The operator conducts analysis in the order shown by the sequence file.3. After analysis, a report set is created from the sequence file used in the analysis. The experiment leader uses thereport set to review the data chain generated by the sequence.Until now, a problematic issue with data integrity in spectrometers has been the existence of orphan data (data which is isolated and notreviewed, despite being used in the analysis). However, the LabSolutions Analysis Sequence option not only meets the requirements for dataintegrity by preventing the creation of orphan data, but also allows for highly efficient spectrometer operation.Creation of SequenceRun SequenceBackground MeasurementsRun LabSolutions UV-VisMeasure Standard SampleConnect the Instrument and InitializeBackground MeasurementsOperations that are notincluded in the sequence cannotbe implemented.Sample MeasurementsPrevention of Orphan DataMeasure Sample 01Measure Sample 02Measure Sample 03UVOperations Not Includedin the AnalysisSequence FileUV-2600i/UV-2700iUV-VIS Spectrophotometer13

Optional SoftwareAn autosampler can be used to automate analysis inorder to avoid the trouble of having to replace cellsand enable simultaneous analysis of many samples.Measurement s Automate d with Automatic ControlAutomatic control satisfies needs of customers that want to link the spectrophotometer to non-Shimadzu instruments or operate thespectrophotometer from the LabSolutions UV-Vis software without operator intervention.Automatic Control of Shimadzu U V I n s trument sAutomatic control functionality is used by LabSolutions UV-Vis toUsing this functionality enables automated system analysis,successively perform operations automatically in order of thepermits execution of specific operations, such as start/stopassigned commands, without an operator having to click buttonsoperations that do not require an operator performing theor enter characters in software windows with a mouse oroperations in a window, and can achieve a system that preventskeyboard.human errors.② Read③ExecuteUV-2600i/2700iLabSolutionsUV-Vis④ ResponseCommand fileResponse file① Commands⑤ ConfirmationHost systemCommands are text files that can be used to configure specialized systems. By placing simple text files that contain a list of commands in a folder,LabSolutions UV-Vis automatically reads the commands contained in the file, loads the parameter settings file, performs baseline corrections, measuresthe spectrum, or performs other processes automatically.14

OptionalAutosampler Used for Continuous Analysisof Up to 360 SamplesIf used in combination with an ASX Series autosampler for automatic analysis,up to 360 samples can be automatically analyzed continuously. Furthermore,PreviousUV-Vis [Automatic Analysis]100 samples/day360 samples before noonthe spectral evaluation function can be used to navigate the entire processfrom measurement to data analysis.SelectautomaticanalysisIntuitively understandable rack display ensuresoperations from analysis to specifying settingscan be performed confidently for all specifiedanalyses.SetparametersettingSetting windowAutomatic analysis application screenMeasure,quantify,analyze dataEither the quantitation mode, spectrum mode, or photometricmode can be selected for continuous analysis. In combinationwith the spectral evaluation function, it is also possible to quicklydetermine pass/fail results visually after measuring multiplesamples.For automatic multianalyte analysis of 240 analytesASX-560 Autosampler(P/N 211-94230-01)Sample containers and number of samples:10, 50-mL containers (standard samples)or 240, 14-mL containers360, 7-mL containers (rack sold separately)160, 20-mL containers (rack sold separately)84, 50-mL containers (rack sold separately)Size: W580 D550 H620 mm (main unit)(including sample probe)UV Automatic Analysis SystemASX-560 UV-2600i Sipper UnitFor automatic multianalyte analysis of 120 analytesASX-280 Autosampler(P/N 211-94412)Sample containers and number of samples:10, 50-mL containers (standard samples)or 120, 14-mL containers180, 7-mL containers (rack sold separately)80, 20-mL containers (rack sold separately)42, 50-mL containers (rack sold separately)Size: W355 D550 H620 mm (main unit)(including sample probe)UV-2600i/UV-2700iUV-VIS Spectrophotometer15

Optional SoftwareOptional software adds various data analysis functions to the spectral evaluation function in LabSolutions UV-Vis.Pass/fail criteria can also be specified for data analysis results.C o l o r C al culation Sof t war e(P/N 207-24528-91)This software is used to calculate the color value of measured substances based onmeasured spectra. It can also display color diagrams, such as by plotting color coordinates inan XYZ color system or plotting CIELAB lightness index or color coordinate values. It includes the major calculation parameters, such as the XYZ color system, CIELAB,CIELUV, Munsell color system, mentalism, yellowness, whiteness, and color difference. Colors relevant to JIS and ASTM standards can be calculated.* Measurement illuminants, viewing angle, and other parameters can be specified for thevarious types of calculation.Film T h i c k n e s s C a l c u l a t i o n S of t wa r e(P/N 207-25804-91)This software is used to calculate film thickness from measured spectra based on theinterference interval method. (Calculating the film thickness requires entering therefractive index of the sample.) The interference interval method calculates the film thickness based on the intervalbetween interference peaks (or valleys). The incident angle and wavelength range forfilm thickness calculations and peak (or valley) detection parameters can be specified.U PF C alculation Sof t war e(P/N 207-25806-91)This software is used to calculate ultraviolet protection factor (UPF) values based onmeasured spectra. It can calculate UPF, UVA, UVB, and ultraviolet protection values for either UVA and UVB. Values relevant to JIS, DIN, BS, AATCC, AS/NZAA, or GB/T standards can be calculated.*Automate d A n a l y s i s S of t wa r e(P/N 207-25807-91)This software controls the ASX-560/280 autosampler.CETAC connection kit is required to connect the device to the ASX separately.Solar Radiation C al culation Sof t wa r e(P/N 207-25805-91)This software is used to calculate solar transmittance/reflectance based on measured spectra. It includes major calculation parameters, such as visible light transmittance/reflectance,total light transmittance/reflectance, near-infrared reflectance, ultraviolet ray transmittance, CIE damage factor, and skin damage factor. Parameters relevant to JIS, ISO, and GB/T standards can be calculated.*16* For more details about applicable standards, contact Shimadzu.

Guide to Selecting AccessoriesIn order for UV-Vis and NIR spectrophotometers to perform their full functions, it is necessary to select the appropriate accessories for the application field and sampleproperties. A wide variety of accessories are available to support a wide range of applications, from basic measurement such as transmission and relative/absolutereflection measurement, to multi-sample and micro-sample measurement. Please refer to the UV-VIS Series Accessories handbook (C101-E070) for details.Liquid SamplesSamplesMeasurement Method and ConditionsAccessoriesStandard Sample Compartment 10 mm CellSample volume: 2.5 mL min.Micro-volume measurement1 mL min.Semi-Micro Cell Micro Cell Holder with Mask500 μL min.Micro Cell Micro Cell Holder with Mask50 μL min.Super-micro Cell Super-micro Cell HolderFor automatically measuring samples in multiple cellsSamples with high absorbance, but that are difficult to dilute (short optical path measurement)Samples with low absorbance, but that are difficult to concentrate (long optical path measurement)For automaticallymeasuring samplesTransparent in multiple cellsSamplesFor uremeasurement)Long-Path Cell (20, 30, 50, 100 mm) Long-Path Rectangular Cell HolderNormal measurementMulti-Cell Sample Compartment (sample volume: 2.5 mL min.)Small sample volumes (50 μL min.)MMC-1600 8/16 Series Micro Multi-Cell Holders and CellsRequires temperature controlCPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner(sample volume: 2.5 mL min.)Temperature-controlled with water circulationConstant-Temperature Cell Holder NTT-2200P Constant-Temperature Water ormal measurementTCC-100 Thermoelectrically Temperature-Controlled Cell HolderFor automatically measuring samples in multiple cellsCPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell PositionerTm analysis or variable temperature measurementS-1700 Thermoelectric Single Cell HolderRequires temperature control (constant-temperature water circulation)AutomaticallyTemperature control not necessarysupplies sampleto flow cellsRequires accurate Requires temperature control(constant-temperature water circulation)(automatic analysis) control ofaspiration volume. Temperature control not necessaryFor automating measurement of multiple samplesSuspensionSamplesMMC-1600 8/16 Series Micro Multi-Cell Holders and CellsShort-Path Cell (1, 2, 5 mm) Spacer for Short-Path Cell160C Sipper Unit NTT-2200P160L/160T/160U Sipper Unit (Select type based on liquid volume.)Syringe Sipper CN NTT-2200P (Select flow cell based on liquid volume.)Syringe Sipper N (Select flow cell based on liquid volume)Sipper Unit or Syringe Sipper ASC-5 Auto Sample ChangerWavelength range: 240 nm min.Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)Absorption measurementof suspension samplesFor measuring UV region above 190 nmSolidSpec-3700iDUVTurbidity measurementLight transmitted light turbidity measurement(commonly used measurement method)10/50 mm Cell Long-Path Rectangular Cell Holder(Optical path length of cell depends on test method.)Integrating sphere turbidity measurementIntegrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)Solid SamplesSamplesMeasurement Method and ConditionsLess than 3 mm thickTransmittance measurementSmoothSurfaceSamples*Relative specularreflectancemeasurementRequires a large integrating sphereIntegrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)(due to ISO compliance and other reasons).Large sample size (over 100 mm square)Large-Sample Compartment (MPC-2600A/603A or SolidSpec-3700i) Glass Sample Holder for MPC series/SolidSpecNormal measurementSpecular Reflectance Measurement Attachment (5 incident angle)Large sample size (over 100 mm square)SolidSpec-3700i Large Specular Reflectance Measurement Attachment (5 incident angle)5 incident angle measurementAbsolute specular12 /30 /45 incident easurementVariable incident angle measurementRelative diffusereflectancemeasurementTransmittance measurementRoughSurfaceSample**More than 3 mm thickRelative tAccessoriesStandard Sample Compartment Film Holder, Cell Type Sample Holder,Glass/Film Holder for Standard Sample CompartmentIntegrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)Absolute Specular Reflectance Attachment (ASR-3105) (Requires a Large-Sample Compartment andBIS-3100/3700/603 Sample Base Plate Integrating Sphere Set separately).Absolute Specular Reflectance Attachment (ASR-3112, ASR-3130, ASR-3145) (Requires a Large-SampleCompartment, BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set, a

During measurements, data can be automatically sent to Excel in real time for using macros to automatically obtain desired values. Measures Slight Differences in Absorbance Scalability to near-infrared measurement. Ultra-low stray light enables measurements down to absorbance values of 8 Abs.