Full Line Of Radiation Shielding Products

Transcription

FULL LINE OFRADIATION SHIELDING PRODUCTSLEAD LINED SHEET ROCK SUBMITTALRadiation Protection Products (RPP)manufactures and distributes a full lineof radiation shielding products. Theyinclude Lead Lined Doors (solid corewood, lead lined, and steel strapped),Lead Lined Drywall (otherwise knownas Lead Lined Sheetrock or Lead LinedGypsum Wallboard) and Lead LinedPlywood, Leaded X-ray Glass, LeadLined Frames for borrowed lites anddoors, pass boxes and many other leadproducts.Radiation Protection Products uses onlythe finest quality material and exercisesthe best quality control possible.We offer a top quality line of leadshielding products at a competitiveprice with delivery to satisfy your needs.For additional information concerningRPP’s products or services, pleasecontact us toll free at:888-746-4777 PHONE866-554-8445 FAXLead Backed ProtectionGypsum BoardProducts,Type: RPP-LBGRRP-LBGRadiationInc.RadiationProtection LinedProducts,Inc.Type:RPP-LeadDrywallType RPP-Lead Lined Drywall (5/8 in thick) leadbacked gypsum panels (lead having a purity of99.9% meeting the Federal Specification QQL-201f, Grade "C") for use in Design Nos. U301,U305, U404, U411, U415, U419, U423, U424, U435,U438, U445, U465, U469, U493, V438, V439, V477,V478, V479, V490, V498, V499, W410.ALL SHIELDINGPRODUCTS PROVIDEDMEET THE FOLLOWINGSPECIFICATIONS:Sheet LeadSheet Lead shall meet or exceedthe Federal Specification QQL-201 FGrade C and ASTM B749-03 StandardSpecification for Lead and Lead AlloyStrip, Sheet and Plate Products, seeNCRP reports #33, #35, #49 and#147. Includes NCRP #151.Gypsum BoardGypsumboardBoardshallshallmeetor exceedGypsummeetor exceedASTMA82.27,USDAFederalSSL 30D TypeCASTM1396,C36CAN/CSAA82.27,III Grade X. SS-L-30D, Type III, Grade X.SpecificationLeaded GlassLeaded Glass shall meet or exceedFederal Specification DD-G-451.Radiation Protection Products manufactures all lead shielding products inaccordance with Lead Industries HandBook and all NCRP Applicable Reports(#33, #35, #39, #40, #49 and #147)and NBS, HB. #114.Cassette Transfer CabinetsCassette Transfer Cabinets shall meet orexceed MIL-C-3673 (DM).Wood and Plastic Laminate DoorsAll Wood Doors shall meet or exceedthe ANSI/NWMA Industry StandardI.S.I.-80, I.S.I.4-80, NCRP Report #49.TERMS ANDCONDITIONS OF SALESPrices in U.S. DollarsPrices are in U.S. dollars, F.O.B. factory,Chapel Hill, Tennessee, unless otherwise specified. Prices, specifications,and terms of sales are subject tochange without notice. All orders aresubject to review prior to acceptance.TermsNet 30 days on established accountswith approved credit. Visa/MasterCard.CreditNew accounts, pending credit approval,may be immediately expedited byenclosing a check, wire transfer or creditcard. To facilitate opening of accounts,please forward your bank and four (4)trade references. Tax-exempt or ResaleCertificate required if applicable.MinimumMinimum invoice of 500.00. Ordersunder 500.00 may require paymentby Visa or MasterCard.Ordering/PurchasingYour purchase order or contract isrequested on all orders. All ordersshould be confirmed and clearly marked“Confirmation—Do Not Duplicate.”ShipmentUnless detailed shipping instructions arespecified on all orders, we reserve theright to choose the method of transportation and to make partial shipments, ifnecessary.Packaging/Set Up ChargeSpecial packaging quoted as extra.Set up charges may be applicablewith certain fabrications.ReturnsReturn merchandise will be acceptedonly with prior written authorization.Freight charges must be prepaid.1000 Superior Boulevard, Suite 310 Wayzata, MN 553911.888.RiNGRPP (1.888.746.4777) TOLL FRee FAX: 1.866.554.8445www.radiationproducts.comserving the nation's lead needs for over 50 years with a full line of radiation shielding products

R adiation S H I E L D I N GLead Lined drywallRadiation Protection Products uses onlyFire Code Sheetrock products.Lead Lined Drywall (also referred toas Lead Lined Sheetrock or Lead LinedGypsum) is supplied with lead liningbonded to 1/2" or 5/8" drywall.Custom sizes for Lead Lined Drywallare quoted upon request. We alsoprovide lead lining bonded to specialtydrywall such as moisture and moldresistant board. Lead Lined Drywall issupplied with 2" strips of the same leadthickness and height and 3/8" diameterlead discs.Installation InformationLead Lined Drywall consists of a singleunpierced sheet of lead laminated tothe specified thickness of drywall.The bonding is accomplished with acontinuous layer of mastic adhesive.The Lead Lined Drywall should befastened at a minimum of 8" oncenter at the edges of each sheet, andat a minimum of 12" on center at theintermediate studs with normal drywallscrews. 2" wide strips of sheet leadof the same lead thickness should beapplied to each of the joint studs usinga standard type of construction adhesive, prior to installing the Lead LinedDrywall. These strips of sheet lead willprovide the necessary 1" overlap withthe adjoining sheets. Each fastener willbe covered with a lead disc 3/8" indiameter and equal in thickness tothe lead laminated to the sheetrockto eliminate the possibility of radiationleakage at the point of fastening. Theyshould be applied using a fast dryingconstruction adhesive.Refer to the drawings here for thetypical methods of installing andfastening lead laminated drywall.FASTENERS 8"O.C. AT EDGESCEILING HEIGHTdrywall12" O.C. ATINTERMEDIATE STUDSLEAD LINED GYPSUM BOARDTO HEIGHT INDICATEDFOR LEAD THICKNESSES THAT EXCEED1/8" PLEASE REFER TO OUR LEADLINED PLYWOOD PAGE.You may also call us directly to determine if layering lead is an option.3/8" LEAD DISC3/8"DIAM.LEADDISCSABOVE 7'-0"5/8"LEADLINEDGYPSUMBOARDLEAD LINED3/8" DIAM.LEAD DISCS5/8" LEAD LINEDGYP. BD.2" WIDESTRIPS-SAMETHICKNESSAS GYPSUM BD.LEAD LININGSTEEL STUDS@ 16" O.C.GYPSUM BOARDTO 7'-0"A.F.F.2" WIDE STRIPS-SAME THICKNESSAS GYPSUM BD. LEAD LININGGYPSUM BOARD DETAILOUTSIDE CORNERSTEEL STUDSSTEEL STUDS@ 16" O.C.INSIDE CORNERSTEEL STUDSSTL STUDS @ 16" O.C.5/8" LEAD LINED GYP. BD.WALL DETAILSHIMS NEEDED@Shims(optional)INTERMEDIATE STUDS2" WIDE STRIPS @ GYP.BD. JOINTS (SAMETHICKNESS AS LEADLINING)1000 Superior Boulevard, Suite 310 Wayzata, MN 553911.888.ringrpp (1.888.746.4777) Toll Free Fax: 1.866.554.8445www.radiationproducts.comserving the nation's lead needs for over 60 years with a full line of radiation shielding products

radiation shieldingLead AnglesLEAD ANGLESSave on Labor."Easy Installation"This leak-proof, Lead Angle systemprovides complete coverage of gammarays.and eliminates LEAD STRIPS andDISCS for all Lead Lined Drywall andLead Lined Plywood applications.cornerdetailLEAD ANGLEGYPSUMBOARDSTEEL STUDOur Leak-Proof Lead Angles areavailable in all lead requirements andall heights.Available only at Radiation ProtectionProducts, Inc2-1/4" x 1-1/2" LEAD ANGLESHEET METALSCREWSHEET ROCK SCREWLEADGYPSUM BOARDPATENTED1000 Superior Boulevard, Suite 310 Wayzata, MN 553911.888.ringrpp (1.888.746.4777) Toll Free Fax: 1.866.554.8445www.radiationproducts.comserving the nation's lead needs for over 50 years with a full line of radiation shielding products

Radiation shieldingFor cut outs and penetrationsWhen installing lead lined drywall(lead lined sheetrock, lead linedgypsum), all cut outs and penetrationswill require sheet lead to ensurecontinuous shielding throughout theroom. Additional sheet lead can besupplied to easily allow for the propershielding of penetrations such asreceptacles, light switches, ducts andtelephone/data cablesLEAD LININGOUTLET BOXLEAD LINEDDRYWALLLEAD FOR OUTLET BOXESLEAD G. BDLEAD G. BDLEAD G. BDVERTICAL DUCTBACK OF DUCT LEAD LINEDRETURN DUCTLEAD WRAPPIPE PENETRATIONLEAD WRAPTHRU DUCT WRAP(TYP) PIPE WRAPWALL DUCT DETAIL1000 Superior Boulevard, Suite 310 Wayzata, MN 553911.888.ringrpp (1.888.746.4777) Toll Free Fax: 1.866.554.8445www.radiationproducts.comserving the nation's lead needs for over 50 years with a full line of radiation shielding products

pure lead productssheet leadRadiation Protection Products uses only thepurest lead available for our Sheet Lead andLead Bricks. Absolutely no refining takes placeat our facility, making us one of the cleanest,most environmentally friendly radiation shieldingproviders in the industry, providing you with thehighest quality sheet lead available.If you have any questions about the SheetLead we can provide, please contact RadiationProtection Products.Nominal Sheet LeadSizes and Weights*ActualThicknessApp. Thickness in InchesPoundsPer Sq. Ft.DecimalFraction11 1/2.0156.02341/64 - .5mm3/1282.03121/322 1/2.03915/128 - 1.0 mm3.04683/643 1/2.05477/1284.06251/16 - 1.58mm5.07815/64 - 2.1mm6.09373/32 - 2.5mm7 01* The weights given apply to common lead only.Other types of lead, such as antimonial or hardlead, weigh slightly less for a given thickness.1000 Superior Boulevard, Suite 310 Wayzata, MN 553911.888.ringrpp (1.888.746.4777) Toll Free Fax: 1.866.554.8445www.radiationproducts.comserving the nation's lead needs for over 50 years with a full line of radiation shielding products

partial list of j o b sfurnished by rppJobLocationContractorBay Care Med CenterGreen Bay, WIM.A. Mortenson Co.Montgomery General HospitalOlney, MDH.B.E. Co.Cleveland ClinicWooster, OHMarshall ErdmanFort Defiance Health CareFort Defiance, AZBorder Glass & AluminumEmpire Lath & PlasterFlintco ConstructionElmdorf Air Force BaseAnchorage, AKM.A. MortensonMayo ClinicRochester, MNMulachy DrywallMayo ClinicRochester, MNM.A. MortensonMayo ClinicRochester, MNWeis BuildersHazardous Devices SchoolRedstone Arsenal, ALTravis Air Force BaseTravis AFB, CANewberg-BrindersonNastasi & AssociatesMontefiore Medical CenterBronx, NYTurner ConstructionV.A. Medical HospitalMinneapolis, MNM.A. Mortenson Co.Regional Medical CenterFayetteville, ARVVP America Inc. dba Binswanger GlassGE Test CellsWaukesha, WIOlympic Wall SystemsCessna AirlinesWichita, KSNorthwest AirlinesMinneapolis, MNPhillips Medical SystemsScarborough, OHSyncorHicksville, NYU.S.L.E. BaseSand Island, HIPaglia EngineeringSmith HospitalValdosta, GABrasfield & GorriV.A. HospitalAnn Arbor, MIP.J. DickMcMinnville Community HospitalMcMinnville, ORMcDevitt Street BovisMary Washington HospitalFredricksburg, VACentex Rodgers1000 Superior Boulevard, Suite 310 Wayzata, MN 553911.888.ringrpp (1.888.746.4777) Toll Free Fax: 1.866.554.8445www.radiationproducts.comserving the nation's lead needs for over 50 years with a full line of radiation shielding products

We also provide lead lining bonded to specialty drywall such as moisture and mold resistant board. lead lined Drywall is supplied with 2" strips of the same lead thickness and height and 3/8" diameter lead discs. installation information lead lined Drywall consists of a single unpierced sheet of lead laminated to the specified thickness of drywall.