Pressure / Temperature Chart

Transcription

Pressure / temperature chart(continued)General dataCompatibilityAny pipe from which are fitted out with Bürkertadaptor S022 (see separate data sheet)Materials HousingCoverSealsFixed connector/cableglandNutWetted part materials Sensor holderProbeSee exploded view, oppositeStainless steel 1.4561 (316L), PPSPPSEPDMPA66Probe120 mm Bürkert pH or ORP probe Type 8203or any combined 120 mm pH or ORP probe,without temperature sensor, with PG13.5 head,S7/S8 connectorTemperature sensorPt1000 integrated within the holderElectrical connections1x 5-pin M12 male fixed connector,or Terminal strip via 1x cable gland M16x1.5Recommended connectioncable for terminal stripShielded cable(Measuring data acc. to CEI 664-1/VDE 0110(4.97))0.25 up to 1.5 mm20.25 up to 1.5 mm20.25 up to 1.5 mm20.25 up to 0.75 mm24 to 8 mmPVC (PVDF on request)PVDF, Stainless steel 1.4571 (316Ti)See probe specific technical data Solid H05(07) V-UFlexible H05(07) V-KWith wire end ferruleWith plastic collar ferruleDiameterStandards, directives and approvalsProtection classIP65, IP67, NEMA 4X and NEMA 6P, with M12cable plug or cable gland tightened or obturatedand cover properly mounted and securedStandard and directives EMCPressureEN 61000-6-2, EN 61000-6-3Complying with article 3 of §3 from 97/23/CEdirective.*EN 60068-2-6 / EN 60068-2-27Vibration / Shock* For the 97/23/CE pressure directive, the device can only be used under following conditions(depend on max. pressure, pipe diameter, type of probe and fluid).Envelope Dimensions [mm](continued)869486.556.5Ø 59.5161514131211109876543210BAPVDFPVCPVDF-200 20 40 60 80 100 120 140 T CApplication range of a 8202 ELEMENT neutrino transmitter:A: with PVDF nut (on request)B: with PVC nutThe measures have been made at an ambient temperature of 60 C,without probe.Application range of a 8202 ELEMENT neutrino transmitter(without probe)- with PVC nut with S022 adaptorP (bar)1615Metal141312111098PVC 76PP543210-10 10 30 50- with PVDF nut with S022 adaptorP (bar)16151413Metal12111098PVC PP7654PVC32PP10-10 10 30 50 70 90(T C) 110 130 T C49.5276.519921356Pressure(bar)8202 ELEMENT neutrinoTechnical DataØ75G1"1/2375

Ordering Chart8202 ELEMENT neutrinoDescriptionCompact transmitter:sensor holder with integratedPt1000 electronic module with coverVoltage supply12 - 36 V DCOutput1 x 4 - 20 mANut materialPVCElectrical connection5-pin M12male fixed connectorCable glandItem no.561 685561 686AccessoriesDescriptionOne Ø 46x2 mm EPDM seal for 120 mm probe holder (with instruction sheet)Item no.559 169EPDM seal for cover/housing sealing561 752Probe holder with PVC nut560 947pH-probe -10.40 C, 0 - 6 bar, pH 0 - 14 - PLASTRODE pH 120 mm560 377pH-probe 0. 80 C, 0 - 6 bar, pH 0 - 14 - FLATRODE pH 120 mm561 025pH-probe -10.60 C, 0 - 6 bar, pH 2 - 14 - LOGOTRODE pH 120 mm427 114pH-probe 0.130 C, 0 - 6 bar, pH 0 - 14 - UNITRODE PLUS pH 120 mm560 376pH-probe 0.130 C, 0 - 16 bar, pH 0 - 14 - CERATRODE pH 120 mm418 319Redox potential-probe 0.80 C, 0 - 6 bar, -2000 . 2000 mV - FLATRODE ORP 120 mm561 027Redox potential-probe -10.50 C, 0 - 6 bar, -2000. 2000 mV - LOGOTRODE ORP 120 mm560 379Redox potential-probe 0.130 C, 0 - 6 bar, -2000. 2000 mV - UNITRODE PLUS ORP 120 mm560 378Storage solution for probe (KCl 3M), 500 ml418 557Cleaning solution set for probe, 3 x 500 ml560 949Buffer solution, 500 ml, pH 4418 540Buffer solution, 500 ml, pH 7418 541Buffer solution, 500 ml, pH 10418 543Buffer solution, 500 ml, Redox potential 475 mV418 5555 pin M12 female straight cable plug with plastic threaded locking ring, to be wired917 1165 pin M12 female straight cable plug moulded on cable (2 m, shielded)438 680NoteFor a complete transmitter the following items must be ordered:– Transmitter, Type 8202 ELEMENT neutrino– pH or ORP probe, Type 8203– INSERTION Adapters (see Type S022)376Sensor versionNone

Every drop counts. With TwinPowertechnology, high efficiency in in-vitrodiagnostic is effortless. The advantages:fewer reagents are required becausethe internal volume of the solenoidvalves has been reduced to an absolute8202 ELEMENT neutrinoIVD madesimple.minimum. Energy consumption is lessbecause two smaller solenoid coils sharethe work in the valve, making this systemmore durable and reliable than previoussystems.The 6624 TwinPower: So muchcleverness in such a small space.More minimum – hardly possible.We make ideas flow.www.burkert.com377

8222 ELEMENTConductivity transmitter with removable operating unit Intuitive menu structure Removable programming puck Data upload / download via puck Diagnostic functionPlease see adaptersConductivity transmitter with programmable outputs. Conductivity andtemperature output via single or dual analog 4-20 mA. Two transistor outputs are also included. Transmitters are engineered for a wide scope ofmeasuring ranges and can be delivered in 2-wire or 3-wire configurations.Intelligent, integrated, beautiful design fits perfectly with an assortment ofeasily configured fittings.Envelope Dimensions [mm](see datasheet for details)Technical DataTechnical data (Pipe conductivity meter)Fluid pressure maxPN16 (232 PSI) (see Pressure/Temperaturechart)Ambient temperature-10 C to 60 C (14 to 140 F) (operating andstorage)Relative humidity 85%, without condensationElectrical dataPower supply4 outputs meter (3-wire)12 - 36 V DC, filtered and regulatedCurrent consumption withsensor4 outputs meter (3-wire) 1 A (with the 2 transistors loads) 5 mA (at 12 V DC without transistors load,without current loop)Reversed polarity of DCProtectedVoltage peakProtected0.20.10.50.00210.005C 1.0C 2500120050100205102C 0.010.51-20 C to 100 C (-4 to 212 F) restricted by theused adaptorrestriction with adaptor S022 in:- PVC: 0 C to 50 C (32 to 122 F)- PP: 0 C to 80 C (32 to 176 F)- Metal: -20 C to 100 C (-4 to 212 F)0.020.010.050.20.1120.5C2440 C to 50 C (32 to 122 F)Environment378B700.2Medium temperature with G 1½” PVC nut connectionwith G 1½” PVDF nut connectionnoneor according to a predefined graph (NACl orultra pure water)or according to a graph defined especially foryour processA970.050.1Temperature compensation-40 C to 130 C (-40 to 266 F)0.1 C (0.18 F) 1 C (1.8 F)10 C (i.e 10 C to 20 C (50 to 68 F) corresponding to 4. 20 mA)0.02Temperature measurement Measuring rangeInternal resolutionAccuracyMinimal temperature range50.05 mS/cm. 10 mS/cm1 nS/cm 3% of measured value2010DN25 to DN110 (DN 25 with reduction)Conductivity measurement Measuring rangeResolutionAccuracy50Pipe diametersewagewaterThe electrode is selected according to the measuring range and medium by using this table.

Pressure/Temperature chartOutput TransistorCurrentProtected for transistor outputsconfigurable as sourcing or sinking (respectively both as PNP or NPN), open collectormax. 700 mA, 0.5 A max. per transistor if the 2transistor outputs are wiredoutput NPN: 0.2 - 36 V DCoutput PNP: V power supply4. 20 mA programmable as sourcing or sinking,configurable in the same mode as transistor:sourcing or sinking,max. loop impedance: 1100 W at 36 V DC;610 W at 24 V DC; 100 W at 12 V DCResponse time (10% - 90%) 150 ms (standard)4 outputs meter (3-wire)General dataCompatibilityMaterials Housing/coverSeals/ScrewsFixed connector mountingplateFixed connectorDisplay/navigation keyNutWetted part materials Conductivity sensorElectrodeAny pipe which are fitted out with Bürkert adaptor S022 (see separate data sheet)Stainless steel 1.4561, PPS / PCEPDM / Stainless steelStainless steelBrass nickel platedPC / PBTPVC or PVDFPt1000 (316Ti) integrated in the sensorDisplay (accessories)Grey dot matrix 128x64 with backlightingConnection d and directives EMCPressureVibration / ShockApprovals UL-Recognized forUS and Canada0 20 40 60 80 100 T CApplication range of a 8222 ELEMENT conductivity meter:A: with PVDF nut (on request)B: with PVC nutThe measures have been made at an ambient temperature of 60 C.1x 5-pin M12 male 1x 5-pin M12 female fixedconnectorsApplication range of a 8222 ELEMENT conductivity meter- with PVC nut with S022 adaptorP (bar)161514131211109876543210-10Shielded cableStandards, directives and approvalsProtection classABPVDF, stainless steel 1.4571 (316Ti)Stainless steel 1.4571 (316Ti ) for cell constantC 0.01 or C 0.1 or graphite for cell constantC 1.0Temperature sensorElectrical connections4 outputs meter (3-wire)Pressure(bar)8222 ELEMENTShort circuitIP65 and IP67 with M12 cable plug mountedand tightened and cover fully screwed downEN 61000-6-2, EN 61000-6-3Complying with article 3 of §3 from 97/23/CEdirective.*EN 60068-2-6 / EN 60068-2-2761010-1 CAN/CSA-C22 No.61010-1MetalPVC PP 10 30 50(T C)- with PVDF nut with S022 adaptorP (bar)161514131211109876543210MetalPVC PPPVCPP-10 10 30 50 70 90 110 T C379

Ordering ChartNut material8222 ELEMENTPVCCell constantC 0.01Electrical connection5-pin M12 male and 5-pin M12 femaleItem No559 619C 0.15-pin M12 male and 5-pin M12 female559 615C 1.05-pin M12 male and 5-pin M12 female559 611C 0.015-pin M12 male and 5-pin M12 female559 621C 0.15-pin M12 male and 5-pin M12 female559 617C 1.05-pin M12 male and 5-pin M12 female559 613PVDFAccessoriesDescriptionDisplay/programming moduleItem No559 168Electrical connector, 5-pin M12 male, plug only560 946Electrical connector, 5-pin M12 male, 2 m prewired559 177Electrical connector, 5-pin M12 female, plug only917 116Electrical connector, 5-pin M12 female, 2 m prewired438 680NoteFor a complete transmitter the following items must be ordered:– Transmitter, Type 8222 ELEMENT– Display/programmer module– INSERTION Adapters (see Type S022)– M12 cable socket, cable connector (only cable socket for a 4-20 mA current output, cable and cable connector for two 4-20mA current outputs)380

Dimensions [mm] of conductivity meter Type 3.8C 1C 0.1C 0.018222 ELEMENTØ 6522C 17097381

8222 ELEMENT neutrinoConductivity meter without display and operating unit Analog 4-20 mA output Universal process connection Three cell constants for covering a widemeasuring range Temperature compensatedmeasurementPlease see adaptersThe Bürkert ELEMENT neutrino meter, Type 8222, is a compact devicedesigned for measuring the conductivity of fluids.Envelope Dimensions [mm](see datasheet for details)Technical DataPipe conductivity meterPipe diameterDN25-110 mm (DN 25 mm with reduction)Conductivity measurement Measuring rangeAccuracy0.05 µS/cm to 10 mS/cm 3% of measured valueTemperature measurement Measuring rangeAccuracy-40 ºC to 130 ºC 1 ºCTemperature compensation Cell constants C 0.1 or 1Cell constants C 0.01according to a NaCl graphaccording to an ultra pure water graphCBAMedium temperature* with G 1½” PVC connection nut 0 ºC to 50 ºCwith G 1½” PVDF connection nut -20 ºC to 100 ºC restricted by the used(on request)adaptorwith G ¾” ext. threadedconnectionrestriction with adaptor S022 in:- PVC: 0 ºC to 50 ºC - PP: 0 ºC to 80 ºC- Metal: -20 ºC to 100 ºC-20 ºC to 100 ºC restricted by the usedadaptorrestriction with adaptor S022 in:- PVC: 0 ºC to 50 ºC- PVDF: 0 ºC to 100 ºC- metal: -20 ºC to 100 ºCFluid pressure maxPN16 (see pressure / temp. chart)4-20 mA output accuracy 1%Technical dataEnvironmentB75C183(continued)Ambient temperature-10 C to 60 C (14 to 140 F)(operating and storage)General dataRelative humidity 85%, without condensationCompatibilityAny pipe which are fitted out with Bürkertadaptor S022 (see separate data sheet)Materials HousingCoverSealsFixed connectorNutWetted part materials Temperature sensorConductivity electrodesSee exploded view, oppositeStainless steel 1.4561 (316L), PPSPPSEPDMPA66PVC (PVDF on request)Temperature sensorPt1000 (316Ti) integrated in the sensorElectrical dataPower supply12 - 36 V DC, filtered and regulatedCurrent consumption withsensor 25 mAReversed polarity of DCProtectedVoltage peakProtectedOutput CurrentResponse time (10% - 90%)382A874. 20 mAmax. loop impedance: 1100 W at 36 V DC;610 W at 24 V DC; 100 W at 12 V DC5 s (standard)PVDF, stainless steel 1.4571 (316Ti)Stainless steel 1.4571 (316Ti ) for cellconstant C 0.01 or C 0.1 or graphite forcell constant C 1.0

Pressure/temperature chart(continued)Electrical connections1x 5-pin M12 male fixed connector,or terminal strip via 1x cable gland M16x1.5Recommended connectioncable for terminal stripShielded cable(Measuring data acc. to CEI 664-1/VDE0110 (4.97))0.25 to 1.5 mm20.25 to 1.5 mm20.25 to 1.5 mm20.25 to 0.75 mm24 to 8 mm Solid H05(07) V-UFlexible H05(07) V-KWith wire end ferruleWith plastic collar ferruleDiameterStandards, directives and approvalsProtection classIP65, IP67, NEMA 4X and NEMA 6P withM12 cable plug or cable gland tightened orobturated and cover properly mounted andsecuredStandard and directives EMCPressureEN 61000-6-2, EN 61000-6-3Complying with article 3 of §3 from 97/23/CE directive.*EN 60068-2-6 / EN 60068-2-27Vibration / CPVDF-200 20 40 60 80 100 120 140 T CApplication range of a 8222 ELEMENT neutrino conductivity meter:A : with PVDF nut (on request) or G¾” external threaded connectionB : with PVC nutThe measures have been made at an ambient temperature of 60 C.8222 ELEMENT neutrinoTechnical 1050* For the 97/23/CE pressure directive, the device can only be used under following conditions(depend on max. pressure, pipe diameter and fluid).C 1.0Application range of a 8222 ELEMENT neutrino conductivity meter- with PVC nut with S022 adaptorP (bar)161514131211109876543210-10C 5001200501002010520.510.20.050.10.02C 0.01SewageThis diagram shows the ranges of the different cell constants of the sensors.MetallPVC PP 10 30 50(T C)- with PVDF nut (on request) with S022 adaptorP (bar)16151413Metall12111098PVC PP7654PVC32PP10-10 10 30 50 70 90 110 130 T C- with G ¾ threaded connection with S022 adaptorP (bar)161514131211109876543210MetallPVCPVC-10 10 30 50 70 90 110 T C383

Envelope Dimensions [mm](see datasheet for details)8656ø16ø24ø24ø24C 1C 1C 0.1C 0.1C 0.0122C 0.01 C 186.5Ø 59.578787878ø16ø2422C 1Ø 055638456183183183ø16ø2486.586183ø16ø2456.5Ø 59.5Ø7578Ø75183Ø 59.511956.511956.58786.5788786.51838222 ELEMENT neutrinowith a G 1½” union connection nutø16ø16ø16ø16ø24ø24ø24ø24G3/4"G3/4"44C 1C 1C 0.144C 0.1C 0.0138C 0.01 C 138C 156

Ordering ChartCompact conductivitymeter with a G 1½” unionconnection nutVoltage supply12 - 36 V DCOutput4 - 20 mASensor versionC 0.01C 0.01C 0.01Nut materialPVCPVCPVCElectrical connection5-pin M12male fixed connectorCable glandsItem no.561 6615-pin M12male fixed connectorCable glands561 6635-pin M12male fixed connectorCable glands561 665561 662561 664561 666AccessoriesDescriptionItem no.EPDM seal for cover/housing sealing561 752EPDM seal for conductivity meter with G ¾” external thread / S022 adaptor sealing*561 955Calibration solution, 300 ml, 5 mS440 015Calibration solution, 300 ml, 15 mS440 016Calibration solution, 300 ml, 100 mS440 017Calibration solution, 500 ml, 706 mS440 018Calibration solution, 500 ml, 1413 mS440 0195 pin M12 female straight cable plug with plastic threaded locking ring, to be wired917 1165 pin M12 female straight cable plug moulded on cable (2 m, shielded)438 6808222 ELEMENT neutrinoDescription* Important!To ensure the tightness between the meter, with G 3/4” thread, and the S022 INSERTION adapter, only this O-ring should be used.NoteFor a complete transmitter the following items must be ordered:– Transmitter, Type 8222 ELEMENT neutrino– INSERTION Adapters (see Type S022)385

8228Inductive conductivity meter Configurable outputs: up to 2 transistorand up to 2 analogue 4. 20 mA outputs Removable backlighted display Simulation of process values and diagnostic functions Sensor-versions available with PEEK,PVDF or PPPlease see fitting S020The analysis gauge, Type 8228, includes a detachable display module. Thisis used for setup, configuration and calibration or required as a processvalue display. For temperature calibration, a temperature sensor is includedas standard.Envelope Dimensions [mm]97(see datasheet for details)7065706526,526,597100 μS/cm.2 S/cm0.1 μS/cm (2% of the measured value 5 μS/cm) 2% (0.2% of the measured value 2 μS/cm)from 3 s (without filter) to 40 s (with slow filter)Temperature measurement Measuring rangeResolutionMeasuring uncertaintyResponse time t90-40 C to 150 C (-40 to 302 F)0.1 C (0.18 F) 1 C (1.8 F) 280 s (without filter)Temperature compensation– none or– according to a predefined graph(NaCl, NaOH, HNO3 or H2SO4) or– according to a graph defined especially for yourprocessMedium temperature withconductivity sensor in-15 C to 100 C (5 to 212 F) PVDF0 C to 80 C (32 to 176 F)PP-15 C to 130 C (5 to 266 F)PEEKTemperature limits may depend on the material the S020 fitting used is made of.Refer to the relevant data sheet or instruction manual and the pressure/temperaturediagram of the fluid on page 3. If the temperature ranges given for the deviceand the fitting are different, use the most restrictive range.Fluid pressure (max.)with conductivity sensor inPN6 (87 PSI) PVDF, PPPN10 (145 PSI)PEEKPressure limits may depend on the material the S020 fitting used is made of. Referto the relevant data sheet or instruction manual and the pressure/temperaturediagram of the fluid on page 3. If the temperature ranges given for the deviceand the fitting are different, use the most restrictive range.Environment386Ambient temperature-10 C to 60 C (14 to 140 F) (operating andstorage)Relative humidity 85%, without condensationHeight above see levelMax. 2000 mTechnical Data246DN15 to 400Conductivity measurement Measuring rangeResolutionMeasurement deviationLinearityRepeatabilityResponse time t90246Pipe diameter154168Complete device data (Fitting conductivity meter)154168Technical Data(continued)General dataCompatibilityMaterials Housing / CoverSeal / ScrewsFixed connector holderM12 fixed connectorDisplay / Navigation keyNutWetted part materials Sensor holderSealAny pipe which are fitted out with Bürkert INSERTION Fitting S020 (see corresponding data sheet)Stainless steel 1.4404, PPS / PCEPDM / Stainless steelStainless steel 1.4404 (316L)Brass nickel platedPC / PBTPCPP, PVDF or PEEKFKM (standard) or EPDM (option)Temperature sensorIntegrated in the sensorDisplay (accessories)Grey dot matrix 128x64 with backlightingElectrical connections 2 outputs meter (3-wire)4 outputs meter (3-wire)Connection cable1x 5-pin M12 male fixed connector,1x 5-pin M12 male 1x 5-pin M12 female fixedconnectorsShielded cable, ø 3 to 6.5 mm; max. 0.75 mm2 crosssection

Technical DataPressure/temperature chart(continued)Electrical data12 - 36 V DC, 10% oscillation rate, filtered andregulated, SELV (safety extra low voltage) circuit witha non dangerous energy levelCurrent consumptionwith sensor 25 mA (at 12 V DC and without the consumptionof the 4. 20 mA output)Reversed polarity of DCProtectedVoltage peakProtectedShort circuitProtectedOutput TransistorCurrent (3-wire)Uncertainty of the outputvalueResponse time(10% - 90%)Polarized, galvanically insulatedconfigurable through wiring and through parameterizing as sourcing (PNP) or sinking (NPN)output NPN: 1 - 36 V DC, max. 700 mA (or 500 mAmax. per transistor if both transistor outputs arewired)output PNP: V supply voltage, max. 700 mA (or500 mA max. per transistor if both transistor outputsare wired)4. 20 mA configurable through wiring and throughparameterizing as sourcing or sinking, 22 mA toindicate a fault (can be parametered)max. loop impedance: 1100 W at 36 V DC;610 W at 24 V DC; 100 W at 12 V DC1% of the full scaleP (bar)1211109876543210APEEK8228Supply voltagePVDFPP-200 20 40 60 80 100 120 140T ( C)A: Application range for complete device (conductivity meter witheither PP, PVDF or PEEK sensor inserted into a Stainless steelS020 fitting)150 ms (default value)Standards, directives and approvalsProtection class acc. toEN 60529IP65 and IP67 with M12 connectors plugged in andtightened and electronic module cover fully screweddownStandard and directives EMCPressureVibration / ShockEN 61000-6-2, EN 61000-6-3 and Annex1,EN 61326-1-7 (Table 2)Complying with article 3 of §3 from 97/23/CEdirective.*EN 60068-2-6 / EN 60068-2-27Ordering ChartHolder materialPPPVDFPEEKOutput1 x transistor NPN/PNP 1 x 4 to 20 mA2 x transistor NPN/PNP 2 x 4 to 20 mA1 x transistor NPN/PNP 1 x 4 to 20 mA2 x transistor NPN/PNP 2 x 4 to 20 mA1 x transistor NPN/PNP 1 x 4 to 20 mA2 x transistor NPN/PNP 2 x 4 to 20 mASeal materialFKMElectrical connection5-pin M12 connectorItem No566 601FKM5-pin M12 male connector 5-pin M12 female connector5-pin M12 connector566 6025-pin M12 male connector 5-pin M12 female connector5-pin M12 connector566 6045-pin M12 male connector 5-pin M12 female connector566 606FKMFKMFKMFKM566 603566 605Note for ordering chart:For a complete conductivity unit the following items must be ordered:- Transmitter Type 8228- INSERTION Fitting Type S020Further versions and information see datasheet type 8228.Options UL and CSA approvals Preparameterized conductivity meters387

8311Pressure transmitter / Switch Pressure measurement and switch inone device Switch for alarm or event logging Bar graph display for local monitoring Continuous or on/off control 2-wire transmitterProgrammable pressure sensor with switching and transmitting functions.It has a large display with bar graph and simple menu guided controls.Connection to the process with standard stainless steel connection. Theprocess value can be transmitted to a PLC via a 4-20 mA signal.Envelope Dimensions [mm](see datasheet for details)Sensor connection G 1/2”BATechnical DataGeneral dataMaterialsHousing, coverFront panel folio / ScrewsCable plug/MultipinMaterials wetted partsSealPC, 20% glass fibrePolyester / Stainless steelPAStainless steelFKM (EPDM option)Sensor elementCeramic cell (Al2O3)Service life of pressure cellMin. 100 million cyclesElectrical connectionsAdjustable 5-pin M12 connector for 5-pinSocket (included)Voltage supply cable50 m, shielded, 0.14 up to 0.5 mm2 max.Complete device data (pipe electronic module)Pipe diameterAny pipe with sensor connection 1/2”Measuring rangeup to 1, 2, 5, 10, 20 or 50 barMedium temperature-20 up to 100 CCD( 100 C for an ambient temperature of max. 40 C)Typical accuracyTransmitter 2-wire versionfor 0 C T 70 Cfor -20 C T 0 Cfor 70 C T 100 CSwitch version 1% of F.S.* 1% 0.03% of F.S.* / C 1% 0.03% of F.S.* / C 1.5% of F.S.*Typical repeatabilityTransmitter 2-wire versionSwitch version 0.06% 0.25%* F.S. Full scale388ABCD54549218Options Cable plug, Type 2508, acc. to EN 175301-803 Outputs: Relay 3 A/250 or 3 A/30 V DC

Technical Data (continued)Electrical dataStandards, directives and approvalsPower supply12-30 V DC , filtered and regulatedProtection classOvervoltage protectionYes, for power supply and for transistor outputsStandards and directivesEMC 30 mA ( 700 mA max. per transistor output used) 750 mA (with load - PNP output configuration) 80 mA (with load - Relay version)OutputTransmitter 2-wire versionopen collector, 2 NPN or 2 PNP, 700 mA max.,Transistor (programmable)NPN: [(V ) minus 0.5 VDC] - 0 VDCPNP: 0.5 VDC - (V )protected against short circuit4-20 mA, Loop resistance: 800 Ω at 30 V DC,Process value550 Ω at 24 V DC, 300 Ω at 18 V DC(For more details, see instruction manual)Switch versionTransistor (programmable)Optional relay (programmable)Reversed polarity of DCopen collector, NPN / PNP, 700 mA max.,NPN: 0.2 - 30 VDC ; PNP: (V )protected against short circuitNormally open/normally closed3 A / 250 V AC or 3 A / 30 V DC (relay)Low voltagePressureVibrationShockTransmitter version: EN 50081-1, 61000-6-2Switch version: EN 50081-1 ,50082-2Transmitter version: EN 61010-1Switch version: EN 61010-1Complying with article 3 of §3 from 97/23/CEdirective.*EN 60068-2-6EN 60068-2-278311Current consumptionTransmitter 2-wire versionSwitch versionIP65 with connector plug-in* For the 97/23/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid).Type of fluidConditionsFluid group 1, §1.3.aDN25 onlyFluid group 2, §1.3.aDN 32, orDN 32 and PN*DN 1000Fluid group 1, §1.3.bDN 25, orDN 25 and PN*DN 2000Fluid group 2, §1.3.bDN 200Protected (for power supply and all outputs)EnvironmentAmbient temperature0 up to 60 C (operating and storage)Relative humidity 80%, non condensatedMain featuresDisplayWorking mode of alarm outputsLarge digital display with 8 characters(4 digital and 4 alphanumeric characters)- 2 switching modes for the output, either hysteresis or window,inverted or notHysteresis modeBar graph (always activated)Transistor Hysteresis, invertedONTransistor Hysteresis, not invertedON3 keys to go through the menus andprogram the deviceSoftware main featuresSwitch and transmitter- International measuring units- 10-segment bar graph- Teach-In for an improved accuracy- Simulation mode to test the programming of the switchingpoints, in dry conditionsTransmitter- Simulation mode to test the programming of 4-20 mA output,in dry conditions- Display and storage of min/max value- Protection by code against unauthorized access- Reset function to default parameters- Alarm output programmable as internal default alarmOFFOLOOHIOFFOLOOHIWindow modeTransistorWindows, invertedONOFFOLOOHITransistorWindows, not invertedONOFFOLOOHI- Programmable delay before switching- Output available as transistor NPN or PNP, relay (up to 3A)- Outputs can be programmed as internal default alarm.389

Ordering ChartPressurerangeElectricalconnectionOutputBurst Pressure[bar]Max. Pressure[bar]Item no.Sensor connection G 1/242557 93474444 5071210444 5062520444 5035040444 504120100444 5058311Transmitter0-1Free positionable 5-pin, M120-2Free positionable 5-pin, M120-5Free positionable 5-pin, M120 - 10Free positionable 5-pin, M120 - 20Free positionable 5-pin, M120 - 50Free positionable 5-pin, M121)4 - 20 mA 2 NPN or2 PNP 1)4 - 20 mA 2 NPN or2 PNP 1)4 - 20 mA 2 NPN or2 PNP 1)4 - 20 mA 2 NPN or2 PNP 1)4 - 20 mA 2 NPN or2 PNP 1)4 - 20 mA 2 NPN or2 PNP 1)PNP standard, can be change in NPN with jumpers on electronic boardAccessories5-pin M12 female cable connector with plastic threaded locking ringItem no.917 1165-pin M12 female connector moulded on cable (2 m, shielded)438 680Description390

8311LaboratoryAnalysismade simple.Every drop counts. With TwinPowertechnology, high efficiency laboratoryanalysis is effortless. Fewer reagentsare required because the internal volumeof the solenoid valves has been reducedto an absolute minimum. At the sametime, energy consumption is less becausetwo smaller solenoid coils share thework in the valve, making this systemmore durable and reliable than previoussystems.The 6624 TwinPower: So muchcleverness in such a small space.More minimum – hardly possible.We make ideas flow.www.burkert.com391

8323Pressure Transmitter for general applications Piezoresistive or thin film sensor element Available with flush diaphragm standardor acc. to EHEDG Housing and wetted parts in corrosion-resistant stainless steel Standard signal 4-20 mA for connectionto automation-system Connector plug for fast installation andserviceThe 8323 compact pressure transmitter is designed to cover the majorityof industrial applications in the field of industrial pressure measurementtechnology. High accuracy, compact design, robust con-struction andflexibility make this instrument universal and suitable for different measurement functions. For technical reasons piezoresistive sensor elementis used for measuring ranges up to 16 bar and thin film sensor elementfor the measuring range of 25 bar. Wetted parts are made of stainlesssteel and completely welded. Internal seal elements, which could restrictthe choice of measuring materials, are excluded.Envelope Dimensions [mm]Technical DataPipe diameterStandard versionFlush diaphragm versionAny pipe with sensor connection:G1/2” A acc. to DIN 16288G1” B with O-ring (range up to 1.6 bar)G1/2” B with O-ring (range 1.6 bar)G1” B for EHEDG (all ranges)(see datasheet for details)A110AB75C27BC[Weld-on socket with connection G1/2”B, G1”B]Material - HousingWetted partsStandard versionFlush diaphragm versionEHEDG flush diaphragmInternal transmitting liquidStainless steel 1.4571for flush diaphragm units)Electrical dataElectrical connection4-pin cable plug,Type 2508, acc. to DIN EN175301-803 (included in delivery)Power supply [Vs]10 -30 V DC0 up to 0.1, 0.16, 0.25, 0.4, 0.6, 1.0, 1.6, 2.5, 4.0,6.0, 10.0, 16.0 or 25.0 barReversed polarity of DCProtectedOvervoltage protectionYesShort circuit protectionYesOutputStandard 4-20 mA signal, 2 wiresLoad in Ω (Vs [V] - 10 [V]) / 0.02 [A]Measurement range[Pressure reference relativepressure (atmospheric)]Stainless steel 1.4571 (and 1.4542 with 25 bar)Stainless steel 1.4571, FKM sealStainless steel 1.4571, EPDM sealSynthetic oil (only for pressure range up to 16 bar or(continued)Sensor elementpiezo ( 16 bar) / thin film ( 25 bar)Fluid temperatureStd. versionStd flush diaphragm versionFlush diaphragm EHEDG-20 up to 100 ºC-30 up to 100 ºC-20 up to 150 ºCAdjustability: Zero / span 10%Response time 1 msCompensated T range0 up to 80 ºCTemperature coefficientAverage Tc of zeroStandard versionFlush diaphragm versionAverage Tc of Spanin compensated T rangeAmbient temperatureStandard versionStandard Flush Diaphragm ver.EHEDG Flush Diaphragm ver.-20 up to 80 C (-4 to 176 F)-20 up to 80 C (-4 to 176 F)-20 up to 80 C (-4 to 176 F)Accuracy 0.5% of F.S.* (2-point calibration)1) 0.25% of F.S.* (Best fit calibration, BFSL)1)Sto

Oct 04, 2021 · EMC Pressure Vibration / Shock EN 61000-6-2, EN 61000-6-3 Complying with article 3 of §3 from 97/23/CE directive.* . Application range of a 8202 ELEMENT neutrino transmitter (without probe) - with PVC nut with S022 adaptor 10 9 8 7 6 5 4 3 2 1 0-10 10 30 50 16 15 14 13 11 Metal PVC P