Interact ReadyluminaireDesign-in GuideInteract Ready luminairesfor connected Cities

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 2Table of Contents1About this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Safety Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Interact Ready connector nodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Interact Ready connector node with 20 mm screw thread interface . . . . . . . . . . . . . . 4Interact Ready connector node with 4-pin Zhaga interface . . . . . . . . . . . . . . . . . . . . . . 4Interact Ready connector node with 7-pin NEMA interface . . . . . . . . . . . . . . . . . . . . . . 43Luminaire requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Interact Ready connector node with 20 mm screw thread interface . . . . . . . . . . . . . . 7Mechanical assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Electrical assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Interact Ready Connector node with 4-pin Zhaga interface . . . . . . . . . . . . . . . . . . . . . . 9Mechanical assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Electrical assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Interact Ready connector node with 7-pin NEMA interface . . . . . . . . . . . . . . . . . . . . . 11Mechanical assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Electrical assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Thermal limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 31About this guideThis document provides guidelines for the assembly ofthe Interact Ready connector node into or onto a streetlighting luminaire.General information pertaining to protection againstelectrical shock, fire, and injury to persons can be foundbelow.The subsequent configuring and programming of theInteract Ready luminaire is described in the User Guide ofthe Interact Ready luminaire configurator.Safety warnings and instructions to be taken into accountduring design-in and manufacturing:The servicing and repair of the Interact Ready luminaireis described in the Service manual for Interact Readyluminaires.It includes the following Interact Ready connector nodes: Interact Ready connector node assembled intoluminaire.LLC7252, LLC7253 (combined with LLC7240) Interact Ready connector node twist-locked onto aluminaire with SR dimmable LED driver and universalsocket. LLC7270, LLC7271 for 4-pin socket conform Zhaga book 18LLC7280 for 7-pin NEMA socket conform ANSI C136.41Safety NoticeIt is important to read ALL safety informationand instructions provided in this manual and anyaccompanying documentation before installing andoperating the products described herein. Act according allcautions and warnings during installation and use of thisproduct.Safety symbols used throughout this manual are asfollows:C CautionAdvising of potential damage.B WarningAdvising of potential injury or death to persons. Do not use products with damaged or defectivecontacts or housings Do not service the luminaire when the mains voltage isconnected Do not use damaged products Cap off all unused wires to prevent accidental contact The luminaire manufacturer is responsible for its ownluminaire design and has to comply with all relevantsafety standards

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 42Interact Ready connector nodesThe Interact Ready connector node is a luminaire-baseddevice that connects a luminaire to the Interact Cityconnected street lighting and management software viathe mobile network.Each Interact Ready connector node contains amodem for mobile communication, a GPS receiver forautomatic location, and a photocell for ambient lightdetection.Interact Ready connector node with 4-pin ZhagainterfaceApplies to connector nodes LLC7270 (dark grey) andLLC7271 (light grey).This connector node is intended for new or upgrade ofluminaires with 4-pin socket conform Zhaga book 18 andSR dimmable LED driver. The connector node is twistlocked onto the socket.Interact Ready connector node with 20 mm screw threadinterfaceApplies to connector nodes LLC7252 (dark grey) andLLC7253 (light grey). These connector nodes require theauxiliary power unit (LLC7240).This connector node is intended for new luminaires withDALI dimmable LED driver. The connector node is fixed tothe luminaire using the 20mm screw thread.Interact Ready connector node with 7-pin NEMAinterfaceApplies to connector node LLC7280 (light grey).This connector node is intended for new or upgrade ofluminaires with 7-pin NEMA socket conform ANSI C136.41and SR dimmable LED driver. The connector node is twistlocked onto the socket.The Interact Ready connector node LLC725x and auxiliarypower unit LLC7240 are packaged separately.DescriptionInteract Readyconnector nodeLuminaire –node interfaceLED drivercontrol methodInteract Ready connector nodewith 20mm screw thread interfaceLLC7252, LLC725320 mm holeDALIInteract Ready connector nodewith 4-pin Zhaga interfaceLLC7270, LLC72714-pin socket conformZhaga book 18SRInteract Ready connector nodewith 7-pin NEMA interfaceLLC72807-pin NEMA socketconform ANSI C136.41SR

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 53Luminaire requirementsThe preferred position of the Interact Ready connectornode is on top of the luminaire, so the connector nodehas a clear view of the sky (open line of sight to the GPSsatellites in the sky). The tilt angle of the connector nodeshould be below 20 , taking into account all the differentpossible mounting angles of the luminaire on the pole.Max. tilt angle 20 Min. distance 1mMetal luminaireFor post-top luminaires, the Interact Ready connectornode can also be positioned inside the luminaire foraesthetical purpose. In case of a metal top cover, theblocking view angle of the sky by the metal top covershould be below 90 . In case of a plastic cover, theconnector node can be positioned directly behind theplastic cover.Max. tilt angle 20 Metal coverPlastic coverMin. distance 1mMax.blockingangle 90

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 6If the Interact Ready connector node cannot be positionedon top of or inside the luminaire according to aboveguidelines, the luminaire shall be connected using theInteract Ready connector kit. The kit is mounted to thepole and requires a drilled hole to bring the cable to thebottom of the pole, where it is connected to the luminaire.The Interact Ready connector node shall be combinedwith a compatible LED driver. The socket-based connectornodes (LLC727x, LLC7280) shall be combined with anSR dimmable LED driver. The connector node withscrew thread (LLC725x) shall be combined with a DALIdimmable LED driver and require the auxiliary power unit(LLC7240). The auxiliary power unit provides the energymeasurement and the low voltage power supply to theconnector node.The full list of compatible and supported LED drivers isdescribed in Interact Ready supported drivers.D NoteIf your luminaire does not meet these requirements,please contact your Signify representative of theInteract Ready program.

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 74Interact Ready connector node with 20 mm screw threadinterfaceApplies to connector nodes LLC7252 (dark grey) andLLC7253 (light grey). These connector nodes require theauxiliary power unit (LLC7240).Mechanical assemblyConnector node Mount the connector node on top of, or inside theluminaire, using a 20 mm hole (between 19.9 millimeterand 22 millimeter) Make sure the white rubber sealing ring 1 is on theoutside of the luminaire and the black rubber ring 2 ison the inside of the luminaire To prevent water ingress or cracking of the screw thread,fix the connector node with the M20 nut 3 and a torquebetween 1.5 and 1.8 Nm To prevent damage to the internal wires due to rotationof the connector node it is advised to make use of theanti-rotation slot, present in the threaded part (referto specification sheet of the Interact Ready connectornode for detailed dimensions)ø 20 mm1 6 mm231.5-1.8 NmFigure 2 Installation instructions for Interact Ready connector node with screwthreadWhen the luminaire surface between the rubber rings isflat and smooth an IP66 rating is possible. When the radiusof curvature near the connector node is 160 mm or higher,the flexible aesthetical ring compresses to visually closethe gap between the connector node and the luminairesurface.Auxiliary power unit Mount the power unit inside the luminaire Fix the power unit with the integrated M8 nut orwith two M4 screws on opposite corners (refer tospecification sheet of the auxiliary power unit fordetailed dimensionsElectrical assemblyThe Interact Ready connector node is suitable for bothclass I and class II luminaires.B WarningDisconnect mains power, when changing wiring.Do not touch any components and wires while poweris on.Wire the Interact Ready connector node, auxiliary powerunit and DALI dimmable LED driver according to belowwiring diagram. Use a solid-core or single-strand wire with a diameterbetween 0.5 and 1.5 mm Separate power lines from control lines where possibleto minimize chance of EMC non-compliance Separate LED/lamp wires from all other internal wires. When the LED driver has DALI and 1-10V interfacewith one wire combined, this combined wire shall beconnected to DA- terminal (grey) of the Interact Readyconnector node Maximum wire length of DALI lines between InteractReady connector node and auxiliary power unit is2 meters Maximum wire length of DALI lines between auxiliarypower unit and LED driver is 2 meters

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 8Power UnitLNLNNoLoDC15VC CDADA DADA DA DA-LNLED driverLNLED driverDA DA-ProgramminginterfaceDA DA-Figure 3 wiring diagram for Interact Ready luminaire fixed Interact Readyconnector nodeA maximum of 3 drivers of the same type can beconnected in parallel to the power box. The total ratedcurrent of connected drivers shall not exceed 4A. The LED/lamp-types shall have identical dimming characteristics.The interface connection wires from the Interact Readyconnector node to the auxiliary power unit and to thedriver(s) provide basic insulation from the mains voltage.A CautionThe Line-out (Lo) and Neutral-out (No) circuits arenot protected from excessive current in case of a faultcondition.

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 95Interact Ready Connector node with 4-pin Zhaga interfaceApplies to connector nodes LLC7270 (dark grey) andLLC7271 (light grey). These connector nodes have 4-pinmetal contacts conform Zhaga book 18. The Interact Readyluminaire has the mating 4-pin socket conform Zhagabook 18 and a compatible SR dimmable LED driver.Line switchAn Interact Ready luminaire with socket allows for theluminaire to be installed today and the Interact Readyconnector node to be attached at a later date. As longas the connector node is not attached, the luminaire willoperate in stand-alone mode.Mechanical assemblyRefer to the supplier’s application specification for theassembly of the Zhaga socket into the luminaire. If present,remove the sealing cap protecting the socket. Twist-lockthe Interact Ready connector node onto the socket.SR dimmable LED drivers do not support the Line Switchfeature. If a group of stand-alone luminaires need to bedimmed via pilot-line, a separate DALI control device withswitching input for mains voltage shall be used. InteractReady supports the Lunatone DALI MC1L device.Electrical assemblyThe Interact Ready connector node is suitable for bothclass I and class II luminaires.B WarningDisconnect mains power, when changing wiring. Donot touch any components and wires while power ison.Refer to the specification sheet of the socket and LEDdriver for the wire type and A DA 1LNLsLNLED driverLNLED driverNLsLine switch231DA DA 23AUXSRSR AUXSRSR DA DA Intra-luminaire DALI busFigure 5 Wiring diagram for Interact Ready luminaire with separate line switch1LNLNLED driverLNLED driver23123AUXSRSR AUXSRSR Intra-luminaire DALI busFigure 4 Wiring diagram for Interact Ready luminaire with 4-pin Zhaga socket.device

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 10SensorsAn Interact Ready luminaire can have a second, downwardlooking Zhaga socket to enable in-the-field upgrade withsensors (e.g. presence, environmental). The downwardlooking socket is wired similar to the upward lookingsocket (Figure 6)ProgramminginterfaceDA DA 1LNLNLED driverLNLED driver23123AUXSRSR AUXSRSR Figure 6 Wiring diagram for Interact Ready luminaire with two Zhaga socketsA maximum of 4 SR dimmable LED drivers can beconnected in parallel to the connector node. The sameoperating current shall be configured for alike LED drivers.The Interact Ready connector node shall be connected thelow voltage power supply (AUX) of only 1 LED driver.

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 116Interact Ready connector node with 7-pin NEMA interfaceApplies to connector node LLC7280 (light grey). Thisconnector node has 7-pin metal contacts conform ANSIC136.41. The Interact Ready luminaire has the mating 7-pinNEMA socket conform ANSI C136.41 and a compatible SRdimmable LED driver.SensorsAn Interact Ready luminaire can have a second, downwardlooking Zhaga socket to enable field upgrade with sensors(e.g. presence, environmental). The downward lookingsocket is wired like the upward looking socket (Figure 7).Mechanical assemblyRefer to the supplier’s application specification forassembly of the socket into the luminaire. If present,remove the sealing cap protecting the socket. Twist-lockthe Interact Ready connector node onto the socketblackwhiteredLNElectrical assemblyThe Interact Ready connector node is suitable for bothclass I and class II luminaires.LNLED driverAUXSRSR B WarningDisconnect mains power, when changing wiring.Do not touch any components and wires while poweris on.LNLED driverAUXSRSR Refer to the specification sheet of the socket and LEDdriver for the wire type and diameter.ProgramminginterfacebrowngreyvioletDA DA -Figure 8 Wiring diagram for Interact Ready luminaire with NEMA socket for theconnector node and Zhaga socket for sensorblackwhiteredLNLNLED driverAUXSRSR LNLED driverAUXSRSR ProgramminginterfaceDA DA -browngreyvioletIntra-luminaire DALI busFigure 7 Wiring diagram for Interact Ready luminaire with 7-pin NEMA socketA maximum of 4 SR dimmable LED drivers can beconnected in parallel to the connector node. The sameoperating current shall be configured for alike LED drivers.The Interact Ready connector node shall be connected thelow voltage power supply (AUX) of only 1 LED driver.

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 127Thermal limitationTo achieve optimal lifetime and reliability, it is critical thatthe temperature of the components in the Interact Readyconnector node remain within its rating. The ambienttemperature is a reference for temperatures of the criticalinternal components.LLC7240 9137 003 xxxCityTouch OLC POWERLNLoNoNCDA-DA DA-tcDA C-LLC725XC Refer to the specification sheet of the Interact Readyconnector node for the temperature ratings.DC15VFor the auxiliary power unit, the case temperature (Tc) isa reference for the temperatures of the critical internalcomponents. The location of the Tc point is identified onthe product label.

Interact Ready luminaires forconnected CitiesDesign-in GuidePage 138CertificatesThe Interact Ready connector node is CE and ENECcertified. It meets the requirements of EMC and GSM/GPRS spurious emissions: IP66, as specified in IEC60529 Radio spectrum according ETSI EN 301 511 EMC according CISPR22These certificates can be re-used and will be providedon request.

Version 1, 30 August 2018 2018 Signify Holding. All rights reserved. Specifications are subject to change withoutnotice. No representation or warranty as to the accuracy or completeness of the informationincluded herein is given and any liability for any action in reliance thereon is disclaimed.Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.All other trademarks are owned by Signify Holding or their respective owners.www.lighting.philips.com