IBM Power Systems E870 And E880 Technical Overview And .

Transcription

Front coverIBM Power Systems E870 and E880Technical Overview and IntroductionNew modular architecture forincreased reliabilityEnterprise POWER8processor-based serversExceptional memory andI/O bandwidthAlexandre Bicas CaldeiraYoungHoon ChoJames CruickshankBartłomiej GrabowskiVolker HaugAndrew LaidlawSeulgi Yoppy Sungibm.com/redbooksRedpaper

International Technical Support OrganizationIBM Power Systems E870 and E880Technical Overview and IntroductionDecember 2014REDP-5137-00

Note: Before using this information and the product it supports, read the information in “Notices” onpage vii.First Edition (December 2014)This edition applies to the IBM Power E870 (9119-MME) and Power E880 (9119-MHE) Power Systemsservers.This document was created or updated on July 25, 2017. Copyright International Business Machines Corporation 2014. All rights reserved.Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP ScheduleContract with IBM Corp.

ContentsNotices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiTrademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiiPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Authors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Now you can become a published author, too! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Comments welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Stay connected to IBM Redbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ixixxixixiChapter 1. General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Systems overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.1.1 Power E870 server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.1.2 Power E880 server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1.3 System control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.1.4 System nodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.1.5 I/O drawers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.2 Operating environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.3 Physical package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.4 System features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.4.1 Power E870 system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.4.2 Power E880 system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.4.3 Minimum features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.4.4 Power supply features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.4.5 Processor card features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.4.6 Summary of processor features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.4.7 Memory features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201.4.8 System node PCIe slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.5 Disk and media features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.6 I/O drawers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.6.1 PCIe Gen3 I/O expansion drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.6.2 I/O drawers and usable PCI slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241.7 EXP24S SFF Gen2-bay Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251.8 Comparison between models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261.9 Build to order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.10 IBM editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.11 Model upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.11.1 Power E870 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.11.2 Power E880 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.11.3 Upgrade considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281.12 Management consoles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291.13 System racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301.13.1 IBM 7014 model T00 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301.13.2 IBM 7014 model T42 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311.13.3 IBM 7953 model 94Y rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321.13.4 Feature code #0551 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321.13.5 Feature code #0553 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321.13.6 The AC power distribution unit and rack content . . . . . . . . . . . . . . . . . . . . . . . . 32Chapter 2. Architecture and technical overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Copyright IBM Corp. 2014. All rights reserved.iii

2.1 Logical diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2 The IBM POWER8 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.1 POWER8 processor overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.2 POWER8 processor core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.3 Simultaneous multithreading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.4 Memory access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.5 On-chip L3 cache innovation and Intelligent Cache . . . . . . . . . . . . . . . . . . . . . . .2.2.6 Level 4 cache and memory buffer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.7 Hardware transactional memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.8 Coherent Accelerator Processor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.9 Power management and system performance . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2.10 Comparison of the POWER7, POWER7 , and POWER8 processors . . . . . . . .2.3 Memory subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.1 Custom DIMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.2 Memory placement rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.3 Memory activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.4 Memory throughput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.5 Active Memory Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.6 Memory Error Correction and Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3.7 Special Uncorrectable Error handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4 Capacity on Demand. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4.1 Capacity Upgrade on Demand (CUoD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4.2 Power enterprise pools and mobile capacity on demand (Mobile CoD) . . . . . . . .2.4.3 Elastic Capacity on Demand (Elastic CoD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4.4 Utility Capacity on Demand (Utility CoD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4.5 Trial Capacity on Demand (Trial CoD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4.6 Software licensing and CoD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.5 System bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.5.1 PCI Express Gen3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.5.2 Service Processor Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.6 Internal I/O subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.6.1 Blind-swap cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.6.2 System ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7 PCI adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.1 PCI Express (PCIe). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.2 LAN adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.3 Graphics accelerator adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.4 SAS adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.5 Fibre Channel adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.6 Fibre Channel over Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.7 USB adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.8 InfiniBand host channel adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.9 Cryptographic Coprocessor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.7.10 CAPI adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.8 Internal storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.8.1 DVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.9 External I/O subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.9.1 PCIe Gen3 I/O expansion drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.9.2 PCIe Gen3 I/O expansion drawer optical cabling . . . . . . . . . . . . . . . . . . . . . . . . .2.9.3 PCIe Gen3 I/O expansion drawer SPCN cabling . . . . . . . . . . . . . . . . . . . . . . . . .2.10 External disk subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.10.1 EXP24S SFF Gen2-bay Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.10.2 EXP24S common usage scenarios. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ivIBM Power Systems E870 and E880 Technical Overview and 848485858691929297

2.10.3 IBM System Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.11 Hardware Management Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.11.1 HMC code level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.11.2 HMC RAID 1 support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.11.3 HMC connectivity to the POWER8 processor-based systems . . . . . . . . . . . . .2.11.4 High availability HMC configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12 Operating system support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12.1 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12.2 IBM AIX operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12.3 IBM i operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12.4 Linux operating systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12.5 Java versions that are supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.12.6 Boosting performance and productivity with IBM compilers . . . . . . . . . . . . . . .2.13 Energy management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.13.1 IBM EnergyScale technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.13.2 On Chip Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.13.3 Energy consumption estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Chapter 3. Virtualization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1 IBM POWER Hypervisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1.1 Virtual SCSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1.2 Virtual Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1.3 Virtual Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.1.4 Virtual (TTY) console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.2 POWER processor modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.3 Active Memory Expansion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4 Single root I/O virtualization (SR-IOV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4.1 Direct access I/O and performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4.2 Adapter sharing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4.3 Adapter resource provisioning (QoS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4.4 Flexible deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4.5 Reduced costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5 PowerVM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.1 PowerVM edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.2 Logical partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.3 Multiple shared processor pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.4 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.5 Live Partition Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.6 Active Memory Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.7 Active Memory Deduplication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.8 Operating system support for PowerVM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.9 Linux support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.10 PowerVM simplification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.11 Single view of all Virtual I/O servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.12 Virtual Storage Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.5.13 Virtual Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.6 System Planning Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.7 IBM Power Virtualization Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.8 IBM Power Virtualization Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.9 VIOS 2.2.3.51 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.10 Dynamic Partition Remote Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 4. Reliability, availability, and serviceability. . . . . . . . . . . . . . . . . . . . . . . . . . 159Contentsv

vi4.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.1.1 RAS enhancements of POWER8 processor-based servers . . . . . . . . . . . . . . . .4.2 Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.2.1 Designed for reliability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.2.2 Placement of components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3 Processor/Memory availability details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3.1 Correctable error introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3.2 Uncorrectable error introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3.3 Processor Core/Cache correctable error handling . . . . . . . . . . . . . . . . . . . . . .

This edition applies to the IBM Power E870 (9119-MME) and Power E880 (9119-MHE) Power Systems servers. This document was created or updated on July 25, 2017. Note: Before using this information and the product it