Magna-CapMagnetic Attachment SystemProduct Catalogue

MAGNA-CAPMagna-Cap is a titanium-based Magnetic Attachment System based on a closed-fieldmagnetic attraction between small, split pole prosthesis magnets and magnetisableimplant fixtures and root abutments.The high strength of the S-Range magnet is the result of a unique internal pole splitting slot.The slot more effectively separates the poles of the magnets, reducing the merging of themagnetic fields and thus dramatically increasing the breakaway forces.The innovative features of the Technovent Magna-Cap system are:--Closed field magnetic system - the magnet is in denture/prosthesis not in the patient.-An innovative lip design with pre-determined movement tolerances, which providescontrolled prosthesis stability whilst still allowing the stress-breaking advantages ofmagnetic attachments to function.-Simple application technique.-Components have low profile for optimum bone support and simple patient hygienecontrol.-Magnet unit is a split-pole construction design, with proven internal and externalcorrosion resistance.-Autoclaveable using normal autoclave cycle.-CE marked and manufactured to the highest standards of the EC directive.-FDA approved for the USA (510K).

PO ST K EEPER S FIT TED TO R O OTRoot PreparationPrepare flat root face just above gingival level.Prepare a post cavity using Root Face Drill.Undercut counterbore cavity with an inverted cone bur (#5).Direct Fit PostAdjust the post length sothat the keeper fullycontacts the root face.Fitting the PostFit the post keeper inthe root with suitablebonding adhesive material.A Seating Tool is used forsafe handling.Cast Post Copings with InsertEnlarge thecounterbore cavity.Use an impressiontechnique to prepare alaboratory model.The surface element of the Insert Keeperis left exposed above the wax-up forretention in the casting investment.Use precious metal alloy with castingtemperature of 800 C.Fitting the cast Insert KeeperFit the cast Insert Keeper with asuitable dentine/metal bondingadhesive material.Use suitable restorative materialto seal exposed root dentine and theouter conditioned surface of the keeper.A Seating Tool is used for safehandling.

MAG N AC A P O R MAG N A B U TMEN T?MagnacapMagnabutmentImplant has spacer abutment in place.Fitted direct to implant fixturePlace the Magnacap/Magnabutment into a matchingsize Hand/Latch Capfit Tool so that the tool markerscoincide with the flats of the keeper.Screw the Magnacap/Magnabutment into the implantabutment/implant fixture until firmly seated using10-20 Ncm tightening torque.IMPRESSION MAGNETPlace the Impression Magnet directly onto theMagnacap/Magnabutment/ Root Keeper during impression.Lip ensures centralisation without the need for the locator ring.LO C ATO R R IN G SYSTEMPlace the lip element of the magnet into the recessed side of themagnetic alloy ring.Seat the assembly on the Magnacap/Magnabutment/RootKeeper to ensure that the prosthesis magnet does not move andremains centralised on the Keeper during lab processing of theprosthesis or direct pickup technique. Remove after curing.Clean and autoclave sterilise after use.

L A B O R ATO RY FA B R IC ATED OVER D EN TU R ESW ITH MAG N E TS IN - SITUIMPRESSION MAGNETTRANSFER MAGNETPlace a Mini/Maxi Transfer orImpression Magnet on thematching size Magnacap/Magnabutment/Root Keeper.Take an impression withTransfer/Impression Magnetsin place.Seat Lab Analogue Abutmentsonto the Transfer/ImpressionMagnets and cast a modelusing hard stone plaster.When the model is set remove theTransfer/Impression Magnets from the impression.Clean, disinfect and autoclave sterilise for re-use.If using the Locator Ring System, place this andthe prosthesis magnet on the replica keeper in theRemove the Locator Ring after processing.Check that there is no resin on the magnet surface.

S-R A N G E AU R IC U L A R MAG N E T SYSTEMEar Magnetwith O RingModifiedMagnacapTechnovents’ new and innovative Auricular Magnet System retains all of theoutstanding features of the original Magnacap System but also has the followingadditional benefits giving it distinct advantages in comparison to conventionalmechanical retention:-S-Range strength magnet retention coupled with a mechanical safety lockwhich overcomes the problems of lateral displacement.-Ease of positioning due to magnetic location.-Low impact forces on implant due to the retention of stress breaking tolerance.-Reduced height (2.7mm) prosthesis magnet.-Novel new Magnacap design ensures O-Ring safety lock engages closer tofitting surface of the magnet.-In normal use prosthesis held in place solely by magnetic retention withmechanical retention only activated if needed.

S-R A N G E AU R IC U L A R MAG N E T SYSTEMCO MPATA B ILIT Y G U ID EVISTAFIXGENERATION 2 R-SAURICULARMAGNACAPBMC2-OR-SSTANDARD/CONSOLE ABUTMENT*GENERATION 2 IMPLANT*(90430/90432/90438/90*Available fromVISTAFIXGENERATION 3 SYSTEMS-RANGEMAGNETAURICULARMAGNETMLL2-OR-SNEW GENERATION AURICULAR3 MAGNACAPMAGNACAPVF-MC1-SVF-MC2-OR-SVF-MC2-SNEW VXA ABUTMENT*GENERATION 3 IMPLANT*VXI300 (3mm/4mm)

S-R A N G E AU R IC U L A R MAG N E T SYSTEMAU R IC U L AR MAG N AC APS FO R VISTAFIX G EN ER ATIO N 2 & 3IMPL AN T SYSTEMS ( A)Auricular Maxi Magnacaps to fit on the Abutment fixture of both Vistafix 2 and Vistafix 3 Implant Abutments.Must be used in conjunction with Auricular Magnet (MLL2-OR-S). xi Magnacap for Vistafix 2Maxi Magnacap for Vistafix 3Height2.7mm3.2mmDiameter5.26mm5.26mmAU R IC U L AR MAG N E T ( B)Excellent magnetic strength coupled with a mechanical backup reduces lateral displacement.Use in conjunction with either B-MC2-OR-S or VF-MC2-OR-S. Non-sterile.CodeMLL2-OR-SDescriptionAuricular MagnetHeight2.7mmDiameterFitting surface 5.5mmExternal (widest)N OTE: CO MPATIBL E WITH CO R R ESPO N D IN G L AB AN ALO G U E C APS ( VF- L AC 2 - O RAN D B- L AC 2 - O R ) . N O LO C ATO R R IN G N EED ED.(A(B

S-R A N G E MAG N AC A PSA B U TMEN T K EEPER TH AT FITS D IR EC TLY O N TO A N IMPLA N T A B U TMEN TN O BEL BIO C AR E EX TER N AL H EX ( BR AN EMAR K) / CO C H L EARVISTAFIX G EN ER ATIO N 2 MAG N AC AP ( A)Non-sterile.CodeB-MC1-SB-MC2-SDescriptionMini MagnacapMaxi MagnacapHeight2.1mm2.1mmDiameter4.4mm5.1mmCO C H L EAR VISTAFIX G EN ER ATIO N 3 MAG N AC APNon-sterile.CodeVF-MC1-SVF-MC2-SDescriptionMini MagnacapMaxi MagnacapHeight2.1mm2.1mmDiameter4.4mm5.1mmN O BEL BIO C AR E MU LTIU N IT MAG N AC AP ( i MagnacapMaxi MagnacapHeight2.1mm2.1mmDiameter4.4mm5.1mmASTR A 4 5 U N I- ABU TMEN T MAG N AC AP ( C )Non-sterile.CodeA-MC1-SA-MC2-SDescriptionMini MagnacapMaxi MagnacapHeight2.1mm2.1mmDiameter4.4mm5.1mmSTR AU MAN N MAG N ACAP ( R C PIL AR MU LTIBASE) ( D )Non-sterile.CodeS-MC2-SDescriptionMaxi ameter4.4mm5.1mmMED ICO N BASIC PO ST MAG N AC APNon-sterile.CodeP-MC1-SP-MC2-SDescriptionMini MagnacapMaxi Magnacap( A)( B)(C)(D)

S-R A N G E MAG N A B U TMEN TSA B U TMEN T K EEPER TH AT FITS D IR EC TLY O N TO A N IMPLA N T FIX TU R EN O BEL BIO C AR E EX TER N AL H EX( BR AN EMAR K) MAG N ABU TMEN T ( A)SterileDescriptionMini MagnabutmentMaxi R AU MAN N MAG N ABU TMEN T ITI ( B)Non-sterileDescriptionMini MagnabutmentMaxi MagnabutmentCodeS-MA1-SS-MA2-SCO C H L EAR VISTAFIX G EN ER ATIO N 2 MAG N ABU TMEN TNon-sterileCodeE-MA1-SE-MA2-SDescriptionMini MagnabutmentMaxi MagnabutmentHeight3.6mm3.6mmDiameter4.4mm5.1mmSO U TH ER N IMPL AN TS MAG N ABU TMEN T FO R IE, IT AN DEX TER N AL H EX ( H X) IMPL AN T FIX TU R mmDescriptionMini MagnabutmentMaxi MagnabutmentMini MagnabutmentMaxi MagnabutmentMini MagnabutmentMaxi MagnabutmentDiameter4.4mm5.1mm4.4mm5.1mm4.4mmSTR AU MAN N EX TR A O R AL MAG N ABU TMEN ionMini MagnabutmentMini MagnabutmentMaxi MagnabutmentMaxi Magnabutment(BDiameter4.4mm4.4mm5.1mm5.1mm

S- R A N G E PR O STH ESIS MAG N E TSN O N - L IPPED PR O STH ESIS MAG N E TNon-lipped Magnets are ideal for Denture applications. Split-pole design with an airtight corrosion ionMini Micro MagnetMicro MagnetMini MagnetMidi MagnetMaxi N11.5NMIN I MIC R O MAG N E T ( MM0 - S)MIC R O MAG N E T ( M0 - S)MM0 - S H EIG H T 1 .8 5 MMM0 - S H EIG H T 1 .9 9 MMD IAME TER 4 .5 MMMIN I MAG N E T ( M1 - S)M1 - S H EIG H T 3 .2 MMD IAME TER 4 .5 MMMID I MAG N E T ( M2 - S)M2 - S H EIG H T 3 .2 MMD IAME TER 5 .5 MMMAXI MAG N E T ( M3 - S)M3 - S H EIG H T 3 .9 MMD IAME TER 5 .5 MM

S- R A N G E PR O STH ESIS MAG N E TSPR O STH ESIS L IP MAG N E T( A)Lip Magnets provide controlled prosthesis stability (lip additional 0.6mm height). Split-pole design with anairtight corrosion seal. ionMini Micro Lip MagnetMicro Lip MagnetMini Lip MagnetMidi Lip MagnetMaxi Lip 4.5mm4.5mm4.5mm5.5mm5.5mmBreakaway Force3.8N4.2N6.5N10.5N11.5NPR O STH ESIS LO N G L IP MAG N E T( BLong Lip Magnets provide extra stability against external displacement forces (lip additional 1.2mm height).Split-pole design with an airtight corrosion seal. Non-sterile.CodeMLL3-SDescriptionMaxi Long Lip MagnetHeight3.90mmDiameter5.5mmBreakaway Force11.5NSIL ICO N E R E TEN TIVE MAG N E T ( CProsthesis Magnet with a retentive ring. Split-pole design with an airtight corrosion seal. Non-sterile.CodeML3-SRMLL3-SR( A)DescriptionMaxi Lip SR MagnetMaxi Long Lip SR MagnetHeight3.90mm3.90mm( B)Diameter5.5mm5.5mmBreakaway Force11.5N11.5N(C)OTH ER SPEC IA LISED MAG N E T SYSTEMSMU LTI- PU R PO SE MAG N E TExtremely powerful attachment for multicomponent assemblies. Attachment comprises of two paired magnets.Each magnet has a flange for retention within the prosthesis. Non-sterile.CodeMPMSDescriptionMulti-Purpose MagnetHeight2.6mm eachDiameter9.4mmBreakaway Force6.5N

D EN TA L AT TAC H ME N TS A N D ACC ESSO R IESPO ST KEEPERFits directly to a root abutment prepared with a Root Face Drill.CodePK1PK2DescriptionMini Post KeeperMaxi Post KeeperHeight1.1mm1.1mmDiameter4.4mm5.1mmIN SER T KEEPERFor cast-on techniques, soldering and multi-component assemblies. Non-sterile.CodeIK1IK2DescriptionMini Insert KeeperMaxi Insert KeeperHeight0.8mm0.8mmDiameter4.4mm5.1mmR O OT FAC E D R IL LTitanium Drill with 1.2mm diameter lead to prep area precise 2.5mm x 2.0mm recesscavity in a dental root for accurate seating of a mini/maxi Post Keeper. Non-sterile.CodeRFD-0DescriptionRoot Face DrillHeight2.5mmDiameter2.5mmSEATIN G TO O LHand held tool with surface magnet to sit root keepers and for general handling ofMagnacap. Non-sterile.CodeSTODescriptionSeating ToolHeight17.0mmDiameter5.5mmH AN D C APFIT TO O LHand held insertion tool used to fit Magnacaps and Magnabutments.In-built magnet provides safe handling. Non-sterile.CodeCF1CF2DescriptionMini Hand Capfit ToolMaxi Hand Capfit ToolHeight17.0mm17.0mmDiameter6.0mm6.5mmL ATC H C APFIT TO O LInsertion tool for use in torque controlled hand piece to fit Magnacapsand Magnabutments. Non-sterile.CodeCF3CF4DescriptionMini Latch Capfit ToolMaxi Latch Capfit ToolHeight17.0mm17.0mmDiameter6.0mm6.5mm

L A B O R ATO RY ACC ESS O R IESTR AN SFER MAG N E TA colour coded magnet used with a pick-up impression technique (lip 0.6mm). Non-sterileCodeMT1MT2DescriptionMini Transfer MagnetMaxi Transfer MagnetHeight3.2mm3.9mmDiameter4.5mm5.5mmL AB AN ALO G U E C AP N O BEL BIO C AR E EX TER N AL H EXAN D CO C H L EAR VISTAFIX G EN ER ATIO N 2A colour coded Magnacap replica for laboratory models. Non-sterile.CodeB-LAC1B-LAC2DescriptionMini MagnacapMaxi MagnacapHeight2.1mm2.1mmDiameter4.4mm5.1mmL AB AN ALO G U E C AP FO R CO C H L EAR VISTAFIX G EN ER ATIO N 3A colour coded Magnacap replica for laboratory models. Non-sterile.CodeVF-LAC1VF-LAC2DescriptionMini MagnacapMaxi MagnacapHeight2.1mm2.1mmDiameter4.4mm5.1mmL AB AN ALO G U E C AP FO R AU R IC U L AR SYSTEMA colour coded Magnacap replica for laboratory models. Non-sterile.CodeB-LAC2-ORVF-LAC2-ORDescriptionMaxi MagnacapMaxi MagnacapHeight2.7mm3.2mmDiameter5.26mm5.26mmL AB AN ALO G U E ABU TMEN TAn abutment replica for laboratory models. Non-sterile.CodeLAA1LAA2DescriptionMini Lab AbutmentMaxi Lab AbutmentHeight2.5mm3.5mmDiameter4.4mm5.1mmLO C ATO R R IN GTemporary locator used during processing of magnets into a prosthesis. Non-sterileCodeLR1LR2LR-LL2DescriptionMini Locator RingMaxi Locator RingLong Lip Locator RingIMPRESSION MAGNETReplaces the use of the Transfer Magnet and Locator Ring. Design ensures greaterretention within silicone impression ini Impression MagnetMaxi Impression MagnetAuricular Impression Magnet

C U STO M PA R TS A N D SPEC IA L O R D ER ITEMSTechnovent also offers a service to produce custom made attachments foritems that do not fall within our stock sizes.A variety of different height magnacaps and magnabutments can beproduced for implant systems in addition to specialised platform systemse.g. Branemark Narrow/Wide platforms.When ordering custom/special order items, a prescription form must becompleted which will require the following information:-Implant system and platform typeAbutment diameter (Mini/Maxi)Abutment heightPatient reference for custom deviceAny other relevant informationPlease contact us for a copy of the prescription form which can befaxed/emailed/posted to you.IF YO U N EED FU R TH ER IN FO R MATIO NO R AD D ITIO N AL TEC H N IC AL H EL PPL EASE EMAIL :MAR K .WATER S@ TEC H N O VE N T.CO MORK ATH .L EAC H @ TEC H N O VEN T.CO M

Technovent Ltd5 York ParkBridgend,CF31 3TBTel: 44 (0)1656 768566www.technovent.cominfo@ technovent.com