OPERATOR’S MANUAL FORGEN-2000-iMM0/0DM0GENERATORCAUTIONRISK OF INJURY! READ ENTIRE MANUAL BEFOREOPERATING! THIS MANUAL IS AN IMPORTANT PART OFTHE GENERATOR AND MUST REMAIN WITH THIS UNIT! Copyright 2015, Mi-T-M Corporation Operator’s Manual37-1334-E/F/S-0308191

IntroductionTHANK YOU for purchasing a Mi-T-M product.READ THIS MANUAL carefully to learn how to operateand service your machine correctly. Failure to do so couldresult in personal injury or equipment damage.THIS MANUAL SHOULD BE CONSIDERED a permanentpart of your machine and should remain with the machinewhen you sell it.MEASUREMENTS in this manual are given in bothmetric and customary U.S. unit equivalents. Use onlycorrect replacement parts and fasteners. Metric and inchfasteners may require a specific metric or inch wrench.RIGHT HAND AND LEFT HAND sides are determined byfacing the control panel end of the machine.The SERIAL NUMBER is located in the Specification orIdentification Numbers section. Accurately record all thenumbers to help in tracing the machine should it be stolen.Your dealer also needs these numbers when you orderparts. File the identification numbers in a secure placeoff the machine.WARRANTY is provided from your dealer for customerswho operate and maintain their equipment as describedin this manual. The warranty is explained on the warrantycertificate shown in this manual.This warranty provides you the assurance that yourdealer will back products where defects appear withinthe warranty period. Should the equipment be abused,or modified to change its performance beyond the originalfactory specifications, the warranty will become void.THIS SPARK IGNITION SYSTEM COMPLIES WITHCANADIAN ICES-002.CE SYSTÈME D’ALLUMAGE PAR ÈTINCELLE ESTCONFORME À LA NORME NMB-002 DU CANADA.WARNINGWARNING: This product can expose you tochemicals including Lead, which is known tothe State of California to cause cancer and birthdefects or other reproductive harm. For moreinformation go to www.P65Warnings.ca.gov2WARNINGWARNING: This product can expose you tochemicals including carbon monoxide, which isknown to the State of California to cause birthdefects or other reproductive harm. For moreinformation go to www.P65Warnings.ca.govOperator’s Manual

IntroductionNOTICEFEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL WARRANTYare applicable to only those engines / generators complied with EPA (Environmental Protection Agency) and CARB(California Air Resources Board) emission regulations in the U.S.A.NOTICETo the engines / generators exported to and used in the countries other than the U.S.A., warranty service shall beperformed by the distributor in each country in accordance with the standard Mi-T-M engine / generator warrantypolicy as applicable.AIR INDEXTo show compliance with California emission regulations, a hang tag has been provided displaying the Air Index leveland durability period of this engine.The Air Index level defines how clean an engine’s exhaust is over a period of time. A bar graph scaled from “0” (mostclean) to “10” (least clean) is used to show an engine’s Air Index level. A lower Air Index level represents cleanerexhaust from an engine.The period of time (in hours) that the Air Index level is measured is known as the durability period. Depending on thesize of the engine, a selection of time periods can be used to measure the Air Index level (see below).Descriptive TermModerate:Applicable to Emissions Durability Period50 hours (engine from 0 to 80 cc)125 hours (engine greater than 80 cc)Intermediate:125 hours (engine from 0 to 80 cc)250 hours (engine greater than 80 cc)Extended:300 hours (engine from 0 to 80 cc)500 hours (engine greater than 80 cc)Notice: This hang tag must remain on the engine or piece of equipment, and only be removed by the ultimate purchaserbefore operation.Operator’s Manual3

ContentsPageSafety . 5Safety Signs . 12Controls . 14Preparing the Generator . 17Operation . 22Troubleshooting . 28Service . 29Storage . 33Specifications . 34Wire Diagram . 35Warranty . 36All information, illustrations and specifications in this manual are basedon the latest information available at the time of publication. The right isreserved to make changes at any time without notice.4Operator’s Manual

SafetyRECOGNIZE SAFETY INFORMATIONThis is the safety alert symbol. When you see this symbolon your machine or in this manual, be alert to the potentialfor personal injury.Follow recommended precautions and safe operatingpractices.UNDERSTAND SIGNAL WORDSA signal word--DANGER, WARNING or CAUTION--is usedwith the safety-alert symbol. DANGER identifies the mostserious hazards.DANGER or WARNING safety signs are located nearspecific hazards. General precautions are listed onCAUTION safety signs. CAUTION also calls attention tosafety messages in this manual.FOLLOW SAFETY INSTRUCTIONSCarefully read all safety messages in this manual andsafety signs on your machine. Keep safety signs in goodcondition. Replace missing or damaged safety signs.Be sure new equipment components and repair partsinclude the current safety signs. Replacement safetysigns are available from your Mi-T-M Customer ServiceRepresentative.C AUGNI NWA R GS INNR N I UAL S .WANMAINTHEN GSR N I UAL S .WAANMTHETIONS INIONSAU TUA LOCMANHES ININOTIONO NS SAU TA LSICTOA NUAUALEMOCA N U INHMTONSHEO T AU T I O A LSUOCMANHEOTLearn how to operate the machine and how to use controlsproperly. Do not let anyone operate without instruction.Keep your machine in proper working condition.Unauthorized modifications to the machine may impair thefunction and/or safety and affect machine life.If you do not understand any part of this manual andneed assistance, contact your Mi-T-M Customer ServiceRepresentative.Operator’s Manual5

CARBON MONOXIDE - POISONOUS GASUse generator outdoors, away from open windows, vents, or doors.Keep generator at least 1 meter (3 feet) away from any structure orbuilding during use.Generator exhaust contains carbon monoxide - a poisonous gasthat can kill you. You CAN NOT smell or see this gas.Never use a generator in enclosed or partially-enclosed spaces.Generators can produce high levels of carbon monoxide very quickly.When you use a portable generator, remember that you cannot smellor see carbon monoxide. Even if you can’t smell exhaust fumes, youmay still be exposed to carbon monoxide.If you start to feel sick, dizzy, or weak while using a generator, get to freshair RIGHT AWAY. DONOT DELAY. TheDANGERDANGERcarbon monoxideUsing a generator indoors CAN KILL YOU IN MINUTES. L'utilisation d'un groupe électrogène àl'intérieur PEUT VOUS TUER ENfrom generators canGenerator exhaust contains carbon monoxide. This is a QUELQUES MINUTES.poison you cannot see or smell.rapidly lead to fullLe gaz d'échappement du groupeélectrogène contient de l'oxyde deincapacitation andcarbone. C'est un gaz toxique que l'ondeath.ne peut pas voir ou sentir.If you experienceNe JAMAIS utiliser à l'intérieur d'unemaison ou d'un garage, MÊME SI lesserious symptoms,portes et fenêtres s'ont ouvertes.NEVER use inside a home Only use OUTSIDE and farget medical attentionor garage, EVEN IF doors away from windows, doors, N'utiliser qu'à l'EXTÉRIEUR et bien éloignéand vents.and windows are open.des fenêtres, portes, et conduits d'aération.immediately. Informmedical staff thatcarbon monoxidepoisoning is suspected. If you experienced symptoms while indoors,have someone call the fire department to determine when it is safeto re-enter the building.NEVER operate the generator in an explosive atmosphere, nearcombustible materials or where ventilation is not sufficient to carryaway exhaust fumes. Exhaust fumes can cause serious injury ordeath.NEVER use a generator indoors, including in homes, garages,basements, crawl spaces, and other enclosed or partially-enclosedareas, even with ventilation. Opening doors and windows or usingfans will not prevent carbon monoxide build-up in the home.Follow the instructions that come with your generator. Locate the unitoutdoors and away from doors, windows, and vents that could allowthe carbon monoxide gas to come indoors.ONLY run generator outdoors and away from air intakes.NEVER run generator inside homes, garages, sheds, or other semienclosed spaces. These spaces can trap poisonous gases EVEN IFyou run a fan or open doors and windows.If you start to feel sick, dizzy, or weak while using the generator, shutif off and get fresh air RIGHT AWAY. See a doctor. You may havecarbon monoxide poisoning.Install battery-operated carbon monoxide alarms or plug-in carbonmonoxide alarms with battery back-up in your home, according to themanufacturer’s installation instructions. The carbon monoxide alarmsshould be certified to the requirements of the latest safety standardsfor carbon monoxide alarms. (UL 2034, IAS 6-96, or CSA 6.19.01).Test your carbon monoxide alarm frequently and replace deadbatteries.6PELIGROUtilizando un generador adentroPUEDE MATARLE EN MINUTOS.El escape de generador contienemonóxido de carbono. Este es ungas tóxico que usted no puede ver nipuede oler.Nunca utilice dentro de un hogar ni elgaraje, INCLUSO SI puertas yventanas estén abiertas.Solo utilice AFUERAS y lejos deventanas abiertas, las puertas, ydescargas.34-1916/083012Operator’s Manual

SAFETY WARNING WHEN REFUELINGGasoline is extremely flammable and its vapors can explode ifignited.Observe all safety regulations for the safe handling of fuel. Handlefuel in safety containers. If the container does not have a spout, usea funnel.Do not overfill the fuel tank, leave room for the fuel to expand.Do not refill fuel tank while the engine is running. Before refuelingthe generator, turn it off and let it cool down. Gasoline spilled on hotengine parts could ignite.Fill the tank only on an area of bare ground. While fueling the tank,keep heat, sparks and open flame away. Carefully clean up anyspilled fuel before starting engine.Always fill fuel tank in an area with plenty of ventilation to avoidinhaling dangerous fumes.NEVER store fuel for your generator in the home. Gasoline, propane,kerosene, and other flammable liquids should be stored outside of livingareas in properly-labeled, non-glass safety containers. Do not storethem near a fuel-burning appliance, such as a natural gas water heaterin a garage. If the fuel is spilled or the container is not sealed properly,invisible vapors from the fuel can travel along the ground and can beignited by the appliance’s pilot light or by arcs from electric switchesin the appliance.Operator’s Manual7

ELECTRICAL HAZARDSTHE GENERATOR (STATOR WINDING) IS ISOLATED FROM THEFRAME AND FROM THE AC RECEPTACLE GROUND PIN.ELECTRICAL DEVICES THAT REQUIRE A GROUNDEDRECEPTACLE PIN CONNECTION WILL NOT FUNCTION IF THERECEPTACLE GROUND PIN IS NOT FUNCTIONAL.CAUTION: NOT FOR INTERRUPTING CURRENT.This product must be grounded. If it should malfunction or breakdown,grounding provides a path of least resistance for electric current toreduce the risk of electric shock.DANGER - IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OFELECTROCUTION. CHECK WITH A QUALIFIEDELECTRICIAN OR SERVICE PERSON IF YOU ARE INDOUBT AS TO WHETHER THE UNIT IS PROPERLYGROUNDED.This generator is equipped with a grounding terminal for yourprotection. Always complete the ground path from the generator to anexternal ground source as instructed in the section labeled “GroundingInstructions” in the Preparation section of this manual.The generator is a potential source of electrical shock if not kept dry.Keep the generator dry and do not use in rain or wet conditions. Toprotect from moisture, operate it on a dry surface under an open,canopy-like structure. Dry your hands if wet before touching thegenerator.Plug appliances directly into the generator. Or, use a heavy duty,outdoor-rated extension cord that is rated (in watts or amps) at leastequal to the sum of the connected appliance loads. Check that theentire cord is free of cuts or tears and that the plug has all three prongs,especially a grounding pin.NEVER try to power the house wiring by plugging the generator intoa wall outlet, a practice known as “back feeding”. This is an extremelydangerous practice that presents an electrocution risk to utility workersand neighbors served by the same utility transformer. It also bypassessome of the built-in household circuit protection devices.If you must connect the generator to the house wiring to powerappliances, have a qualified electrician install the appropriate equipmentin accordance with local electrical codes. Or, check with your utilitycompany to see if it can install an appropriate power transfer switch.For power outages, permanently installed stationary generators arebetter suited for providing backup power to the home. Even a properlyconnected portable generator can become overloaded. This may resultin overheating or stressing the generator components, possibly leadingto a generator failure.8Operator’s Manual

IMPORTANT SAFETY INSTRUCTIONSWARNING: To reduce the risk of injury, read this operator’smanual completely before using. When using this product, thefollowing basic precautions should always be followed:1. Read all the instructions before using the product.C AUGN INWA R GS INNR N I UAL S .WANMAINTH EN GSR N I UAL S .WANMATH ET IONINON S SUT IALO CA MA NUINHEINON S SOTUT ION S SALUT IO CA MA NUALO CA MA NU INHESOTHEI ONOTSUTLAO CA MA NUHEOT2. Do not enclose the generator nor cover it with abox. The generator has a built-in forced air coolingsystem, and may become overheated if it is enclosed.If generator has been covered to protect if from theweather during non use, be sure to remove it and keep itwell away from the area during generator use.3. Operate the generator on a level surface. It is notnecessary to prepare a special foundation for thegenerator. However, the generator will vibrate on anirregular surface, so choose a level place without surfaceirregularities.If the generator is tilted or moved during operation, fuelmay spill and/or the generator may tip over, causing ahazardous situation.Proper lubrication cannot be expected if the generatoris operated on a steep incline or slope. In such a case,piston seizure may occur even if the oil is above theupper level.4. Pay attention to the wiring or extension cords from thegenerator to the connected device. If the wire is underthe generator or in contact with a vibrating part, it maybreak and possibly cause a fire, generator burnout, orelectric shock hazard. Replace damaged or worn cordsimmediately.5. Do not operate in rain, in wet or damp conditions, orwith wet hands. The operator may suffer severe electricshock if the generator is wet due to rain or snow.6. If wet, wipe and dry it well before starting. Do not pourwater directly over the generator, nor wash it with water.7. Be extremely careful that all necessary electricalgrounding procedures are followed during each andevery use. Failure to do so can be fatal.8. NEVER try to power the house wiring by plugging thegenerator into a wall outlet, a practice known as “backfeeding”. This is an extremely dangerous practice thatpresents an electrocution risk to utility workers andneighbors served by the same utility transformer. Italso bypasses some of the built-in household circuitprotection devices.If you must connect the generator to the house wiring topower appliances, have a qualified electrician install theappropriate equipment in accordance with local electricalcodes. Or, check with your utility company to see if it caninstall an appropriate power transfer switch.9. No smoking while charging a battery. The battery emitsflammable hydrogen gas, which can explode if exposedto electric arcing or open flame. Keep the area wellventilated and keep open flames / sparks away whencharging a battery.Operator’s Manual9

IMPORTANT SAFETY INSTRUCTIONS10. Engine becomes extremely hot during and for some timeafter operation. Keep combustible materials well awayfrom generator area. Be very careful not to touch anyparts of the hot engine especially the muffler area orserious burns may result.C AUGN INWA R GS INNR N I UAL S .WANMAINTH EN GSR N I UAL S .WANMATH ET IONINON S SUT IALO CA MA NUINHEINON S SOTUT ION S SALUT IO CA MA NUALO CA MA NU INHESOTHEONTOUT IA LSO CA MA NUHEOT11. Keep children and all bystanders at a safe distance fromwork area.12. It is absolutely essential that you know the safe andproper use of the power tool or appliance that you intendto use. All operators must read, understand and followthe tool / appliance owners manual. Tool and applianceapplications and limitations must be understood. Followall directions given on labels and warnings. Keep allinstruction manuals and literature in a safe place forfuture reference.13. Use only “LISTED” extension cords. When a tool orappliance is used outdoors, use only extension cordsmarked “For Outdoor Use”. Extension cords, when not inuse should be stored in a dry and well ventilated area.14. Always disconnect tools or appliances when not in use,before servicing, adjusting, or installing accessories andattachments.SAVE THESE INSTRUCTIONS10Operator’s Manual

WEAR PROTECTIVE CLOTHINGWear close fitting clothing and safety equipmentappropriate to the job.Wear a suitable hearing protective device such asearmuffs or earplugs to protect against objectionable oruncomfortable loud noises.Operating equipment safely requires the full attention ofthe operator. Do not wear radio or music headphones whileoperating machine.PREPARE FOR EMERGENCIESKeep a first aid kit and fire extinguisher handy.Keep emergency numbers for doctors, ambulance service,hospital and fire department near your telephone.Be prepared if a fire starts.INSPECT GENERATORBe sure all covers, guards and shields are tight and inplace.Locate all operating controls and safety labels.Inspect power cord for damage before using. There is ahazard of electrical shock from crushing, cutting or heatdamage.SERVICE GENERATOR SAFELYBefore servicing the generator, disconnect all equipmentand allow unit to cool down.Service generator in a clean dry flat area.Make sure the engine is stopped before starting anymaintenance servicing or repair.Operator’s Manual11

SAFETY SIGNSIn accordance with the European requirements (eec Directives), the specified symbols as shown in the following tableare used for the products and this instructions manual.PrfrH max12Read the operator's instruction manual.Fire, open light and smokingprohibited.Stay clear of the hot surface.Caution, risk of electric shock.Exhaust gas is poisonous.Do not operate in an unventilated room.Do not connect the generator tothe commercial power lines.Stop the engine before refueling.HOT, avoid touching the hot areas.ON(power and Engine)IN-position of abistable push controlEngine start(Electric start)OFF(power and Engine)Protective earth(ground)Engine stopAlternating currentFuseDiesel fuelDirect currentEngine oilFastPlus ;positive polarityAdd oilSlowMinus ;negative polarityBattery chargingconditionRunOUT-position of abistable push controlChoke ;cold starting aidStopCOSCOPContinuous powerRated frequency (Hz)UrRated voltage (V)IrRated current (A)Maximum site altitudeabove sea-level (m)T maxMaximum ambienttemperature ( )mMass (kg)Rated power (kW)rRated power fact

need assistance, contact your Mi-T-M Customer Service Representative. 6 Operator’s Manual CARBON MONOXIDE - POISONOUS GAS Use generator outdoors, away from open windows, vents, or doors. Keep generator at least 1 meter