MDI

Transcription

MDIMini Dental ImplantsProduct Catalogue

MDI Mini Dental ImplantsMDI Mini Dental ImplantsTable of ContentsSystem Benefits & FeaturesMini Dental Implant SystemSystem Benefits & Features . 1How to Get Started with the MDI Sys tem . 2As the demand for dentures continues to boom, there has never been a better time to start offering the MDI treatment plan in your practice.Mini Dental Implants1.8 mm Diameter Implants .2.1 mm Diameter Implants .2.4 mm Diameter Implants .3.0 mm Diameter Implants .3456Introduced in 1999 as the IMTEC Sendax MDI System, the MDI Mini Dental Implant System is a global market leading small diameter implantsystem, and has quickly become one of the hottest dental products on the market. To the thousands of doctors using the system, it’s no secretwhy the MDI system is so popular: results.Indications: Long-Term Full Denture Stabilization Long-Term Partial Denture Stabilization Long-Term Splinted Fixation of BridgesProstheticsMetal Housings .O-Rings .Lab Analogs & Restorative Copings for 1.8 mm, 2.1 mm & 2.4 mm Implants .Lab Analogs & Restorative Copings for 3.0 mm One-Piece Implants .7778In addition for MDI 3.0 mm implant: Long-Term Fixation of Single CrownsBenefits: Minimally invasive procedureInstruments & DriversSite Preparation . 9Drivers, Wrenches, Ratchet Extension & Adapters . 9 Often no grafting necessary Immediate load in most cases Very cost effective for the dental practice Very affordable for denture patientsSurgical & Restorative Kit & AccessoriesSurgical & Prosthetic Kit . 10Patient Demonstration Models . 10ACCESS Toothbrush . 10MDI is not the only small diameter implant system available but there are plenty of reasonswhy it is a global market-leading system and has been for years:Features:Prosthetic Flow Chart1.8 mm, 2.1 mm & 2.4 mm Implants . 123.0 mm Implants . 13 Implants are placed through a small pilot hole,not into a full osteotomyImplant Surgical ProtocolsMandibular Denture Stabilization . 14Maxillary Denture Stabilization . 16 Attachment designs for customized retentionfor each caseDirect Restorative Protocol . 18 Original retention can be restored by simplychanging an O-RingIndirect Restorative Protocol . 21 A market leading small diameter implant training program Implant designs for stability in soft and densebone (essential for immediate loading) Attachment designs that forgive up to 30 divergencebetween two implants3.0 mm Implant ProtocolsSurgical Protocol . 22Impression & Temporization Protocol . 241

MDI Mini Dental ImplantsHow to Get Started with the MDI System1.8 mm Diameter ImplantsMDI offers market-leading small diameter implant continuing education solutions. MDI Certification Courses areaffordable one-day seminars or mini-residencies lead by some of the most experienced small diameter implantclinicians in the world. Contact your MDI Mini dental implant representative to learn more about MDI Certificationseminars.Ø 1.8 mm10 mm 13 mm 15 mmOB-10.OB-13.OB-15.OB-18.Collared O-BallImplantsO-BallImplantsØ 1.8 mm18 mmProsthetic Head4 mmPolishedTransgingival Collar2.5 mmThread Length10 mm13 mm15 mm18 mmØ 2.7 mmØ 1.8 mmS1810OB.S1813OB.S1815OB.Ø 1.8 mmS1818OB.Classic O-BallImplantsProsthetic Head4 mmPolished Threads2 mm10 mm13 mm15 mm18 mmThread LengthØ 1.8 mmØ 1.8 mmMDI Certification Seminars Offer:SquareHeadImplants10 mm 13 mm 15 mm 18 mmSH-10.CollaredSquare HeadImplantsSH-13.SH-15.SH-18.1.8 mmProsthetic Head4 mmPolishedTransgingival Collar2.5 mmThread LengthØ 2.7 mm10 mm13 mm15 mm18 mm Expert instructors Hands-On Practice with realistic anatomical models (yours to keep)Ø 1.8 mm Group discussion Opportunity to review potential MDI case diagnostics with your instructorMDI Certification Mini-Residencies Offer: Expert instructors LIVE surgical demonstration by your instructor in their clinic Group discussion Opportunity to review potential MDI case diagnostics with your instructor23

MDI Mini Dental Implants2.1 mm Diameter ImplantsØ 2.1 mm2.4 mm Diameter Implants10 mm 13 mm 15 mm18 mmProsthetic HeadIOB-10.IOB-13.IOB-15.IOB-18.Collared O-BallImplantsO-BallImplantsØ 2.4 mmØ 1.8 mmClassic O-BallImplantsS1813IOB.S1815IOB.Thread Length10 mm13 mm15 mm18 mm4 mmPolished Threads2 mmMOB-13.MOB-15.Ø 1.8 mmProsthetic Head4 mmPolishedTransgingival Collar2.5 mmThread Length10 mm13 mm15 mm18 mmØ 2.7 mmO-BallImplantsØ 2.4 mmS1810MOB. S1813MOB. S1815MOB.10 mm13 mm15 mm18 mmMOB-18.Collared O-BallImplantsØ 1.8 mmProsthetic HeadMOB-10.Ø 2.7 mm2.5 mmS1818IOB.18 mm4 mmPolishedTransgingival CollarØ 2.1 mmS1810IOB.10 mm 13 mm 15 mmClassic O-BallImplantsThread LengthØ 1.8 mmS1818MOB.Prosthetic Head4 mmPolished Threads2 mm10 mm13 mm15 mm18 mmThread LengthØ 2.1 mmØ 2.4 mmØ 2.4 mmSquareHeadImplants10 mm 13 mm 15 mm 18 mmMSH-10.CollaredSquare HeadImplantsMSH-13.MSH-15.MSH-18.1.8 mmProsthetic Head4 mmPolishedTransgingival Collar2.5 mmThread Length10 mm13 mm15 mm18 mmØ 2.7 mmØ 2.4 mm45

MDI Mini Dental Implants3.0 mm Diameter ImplantsØ 3.0 mm3.0 mm Diameter Implants9 mm 11 mm 13 mmMII-MOB9.MII-MOB11.MII-MOB13.MII-MOB15.MDI Radiographic TransparenciesØ 1.8 mm15 mmProsthetic Head* Radiographic Transparency for MDI Implants with Collar3.8 mmØ 3.0 mmPolished Transgingival Collar2.5 mmThread Length9 mm11 mm13 mm15 mm Radiographic Transparency for MDI Implants without Collar Radiographic Transparency for 3.0 mm MDI Implants1.8mm3.8 mm2.4mm2.1mm1.8mm2.4mm2.1mm7mmMental um spacing toaccomodate metal m13mm13mm13mm120%Implant diameter in mm -13mm9 mm11 mm13 mm15 mm1.8mm15mmThread Length2.4mm2.1mm15mm1.5 mm1.8mm15mmPolished Transgingival Collar2.4mm2.1mm7mmMental ForamenØ 3.0 mm15mmMANDIBLEFine threadProsthetic Head*15mmMII-OB13.5mmMinimum spacing toaccomodate metal housings15mmMII-OB15.MII-OB11.100%Implant diameter in mm -18mmMII-OB9.O-Ball with Collar - 1.8mm, 2.1mm & 2.4mm18mm15 mmMini Dental ImplantsØ 1.8 mm18mm9 mm 11 mm 13 mmMDIØ 3.0 mm*TiN Coating on Prosthetic Head18mmO-BallImplantsMDI provides radiographic transparencies at no charge.Ask your MDI implant representative for details.18mmMAXILLAAggressivethreadØ 3.0 mmImplant diameter in mm mm10mm10mmThread Length9 mm11 mm13 mm15 mm10mm2.5 mm13mmPolished Transgingival Collar13mm4.8 mm13mmProsthetic Head*Ø 3.0 mm1-800-634-2499www.3MESPE.com/implants3M and ESPE are trademarks of 3M or 3M ESPE AG. Used under license in Canada.70-2013-0372-7MDI Implant Selection GuideØ 3.0 mm*TiN Coating on Prosthetic Head9 mm 11 mm 13 mmMII-T9.MANDIBLEFine threadMII-T11.MII-T13.MII-T15.Bone Density*Ø 1.8 mm15 mmProsthetic Head*4.8 mmØ 3.0 mmPolished Transgingival Collar1.5 mmThread Length9 mm11 mm13 mm15 mmØ 3.0 4mm7mmMental ForamenØ 1.8 mm15mmMII-MT9.2.1mm5mmMinimum spacing toaccomodate metal housings18mm15 mm18mm9 mm 11 mm 13 mm18mmØ 3.0 mm125%* D1 Very Dense Bone* D4 Very Soft BoneNR Not RecommendedSoft-Tissue DepthBuccolingual WidthImplant TypeD1D2D3D4 2 mm 2 mm4 mm 4 mm 5.5 mm 6 mmØ 1.8 mm with Collar33NRNRNR33333Ø 1.8 mm without Collar33NRNR3NR3333Ø 2.1 mm with Collar33NRNRNR3NR333Ø 2.1 mm without Collar33NRNR3NRNR333Ø 2.4 mm with CollarNR33NRNR3NRNR33Ø 2.4 mm without CollarNR33NR3NRNRNR33Ø 3.0 mm with Collarfor maxillaNR33NR33NRNR33Ø 3.0 mm with Collarfor mandible33NRNR3NRNRNR337

MDI Mini Dental ImplantsProstheticsProstheticsMetal HousingsLab Analogs & Restorative Copings for MDI 3.0 mm One-Piece ImplantsØ Diameter3.5 mm4.75 mmMH-2.Micro Metal Housing3.1 mm4.3 mmMH-3.O-Cap3.1 mm4.0 mmO-Rings4.75 mm4.3 mm4 mmMH-1.MH-2.MH-3.O-BallHeadMII-TLALab Analog – O-Ball & Tapered AbutmentLAOB.0Blockout ShimsReplacement O-Ring – For Metal Housing0550-01.TaperedHead3.1 mmMetal Housing3.1 mmMH-1.3.5 mmHeightS1010.Standard MH-1 MDI O-Ring (10 pack)0550-25.Standard MH-1 MDI O-Ring (25 pack)MDI 3.0 mm Hybrid Lab analog for tapered headLAOB.0MDI 3.0 mm lab analog for O-Ball headRestorative Copings – O-BallBlockout Shims (Pack of 25)Standard MH-1 MDI O-Ring0550-10.MII-TLATrim to appropriate length2921.2924.S4118.2921.MDI 3.0 mm O-Ball Impression Coping2924.MDI O-Ball Immediate Temporization CapS4118.MDI Impression & Waxing Coping**Compatible with O-Ball & Square Head Implants.0550-01.9 mmReplacement O-Ring – For Micro Metal Housing & O-Cap0351-01.Micro MH-2 MDI O-Ring0351-10.Micro MH-2 MDI O-Ring (10 pack)0351-25.Micro MH-2 MDI O-Ring (25 pack)Restorative Copings – Tapered AbutmentS1010.0351-01.2920T.2923T.2922T.2920T.MDI 3.0 mm Tapered Abutment Impression Coping2923T.MDI Tapered Abutment Immediate Temporization Cap2922T.MDI Tapered Abutment Waxing CopingLab Analogs & Restorative Copings for 1.8 mm, 2.1 mm & 2.4 mm ImplantsLab Analogs – O-Ball & Square Head5118.MDI O-Ball Prosthetic Head AnalogLAOB.MDI Collared Standard O-Ball AnalogLASH.MDI Collared Standard Square Head AnalogRestorative Copings – O-Ball2921.MDI 3.0 mm O-Ball Impression Coping2924.MDI O-Ball Immediate Temporization CapS4118.LAOB.LASH.2921.2924.S4118.MDI Impression & Waxing Coping**Compatible with O-Ball & Square Head Implants85118.9

MDI Mini Dental ImplantsInstruments & DriversSurgical & Restorative Kit & AccessoriesSite PreparationSurgical & Prosthetic Kit1325.Ridge Mapping CaliperS1011.1.1 mm MDI Surgical Drill (Sterile)2000.15 mm Irrigated Drill ExtenderS1807.Includes: 1.1 mm MDI Surgical Drill (3 pcs.) 1.3 mm MDI Surgical Drill MDI Winged Thumb Wrench MDI Ratchet Adapter Short MDI Ratchet Adapter Long MDI Small Surgical Box Graduated Torque Wrench (including 8071.)Optional2020.Locator DrillS1013.1.3 mm MDI Surgical Drill2.0 mm MDI Surgical DrillS1015.1.5 mm MDI Surgical DrillS1026.2.6 mm MDI Surgical .For use with MDI 3.0 mm Implants2012-01.MDI Surgical & Prosthetic Drivers, Wrenches, Ratchet Extension & AdaptersPatient Demonstration ModelsS9032.MDI Winged Thumb WrenchSMDI-001. MDI Model Clear Acrylic Base8010.Ratchet Wrench8070.Graduated Torque Wrench (including 8071.)SMDI-003. MDI Model Maxilla BaseSMDI-004. MDI Model Pink Acrylic BaseS7015.MDI Ratchet Adapter LongS7011.MDI Ratchet Adapter MediumS7007.MDI Ratchet Adapter Short8071.MDI Torque Wrench Replacement Socket (for 8070.)SMDI-001.SMDI-003.7 mmS9032.8070.8010.SMDI-004.13 mmS7015.109 mmS7011.5 mmS7007.8071.11

MDI Mini Dental ImplantsProsthetic Flow Chart1.8 mm, 2.1 mm and 2.4 mm ImplantsCollared O-Ball ImplantsClassic O-Ball ImplantsCorresponds withLab Analog LAOB.Corresponds withLab Analog 5118.1.8 mmdiameterOB-10.OB-13.OB-15.OB-18.3.0 mm Implants2.1 mmdiameterIOB-10.IOB-13.IOB-15.IOB-18.10 mm13 mm15 mm18 mm2.4 mmdiameter10 mm13 mm15 mm18 mmMOB-10.MOB-13.MOB-15.MOB-18.1.8 mmdiameterS1810OB.S1813OB.S1815OB.S1818OB.Collared O-Ball Analog2.1 mmdiameter10 mm13 mm15 mm18 mmS1810IOB.S1813IOB.S1815IOB.S1818IOB.Corresponds withLab Analog LASH.10 mm13 mm15 mm18 mmS1810MOB.S1813MOB.S1815MOB.S1818MOB.Classic O-Ball AnalogSH-10.SH-13.SH-15.SH-18.10 mm13 mm15 mm18 mmMaxillaAggressive threadMandibleFine threadMaxillaAggressive threadMandibleFine thread3.0 mmdiameter3.0 mmdiameter3.0 mmdiameter3.0 mmdiameter9 mm2.4 mmdiameter1.8 mmdiameter2.4 mmdiameterTaper Abutment ImplantsO-Ball ImplantsCollared Square HeadImplants11 mm13 mm15 II-MOB13.MII-MOB15.9 mm11 mm13 mm15 mm9 mm11 mm13 mm15 mmMII-OB9.MII-OB11.MII-OB13.MII-OB15.9 mm11 mm13 mm15 1.MII-T13.MII-T15.Blockout ShimCollared Square Head AnalogS1010.Metal Housings5118.LAOB.O-Ball Restorative gsMetal -Rings0550-01.120351-01.BlockoutShimO-Ball essionCopingTapered xingCoping0351-01.O-Ball/Square Head WaxingCopingS1010.2921.Tapered Abutment Restorative ing Coping13

MDI Mini Dental ImplantsImplant Surgical ProtocolsMandibular Denture Stabilization3Use the Winged Thumb Wrench to thread the implant into placeuntil the wrench becomes difficult to turn.Preoperative PlanningIMPORTANT: If no significant resistance is met during this mid-stage ofinsertion, the prognosis for the implant reaching its full potential is doubtful.The patient’s bone at this site possibly lacks the required density forpredictable success.After patient selection and evaluation protocols have been completed, the number of MDI implants required (minimum of four)is determined and thoroughly discussed with the patient. The patient’s lower denture is then fabricated or modified, followedby identification of appropriate implant sites. After site selection, the MDI implants should be placed at least 5 mm apart.For mandibular placement, the implants should be placed beginning at least 7 mm anterior to the mental foramen.1Site Preparation Entry points for each MDI implant are marked onthe patient’s tissue.Use of the Winged Thumb Wrench2S9032.Use of vial cap Finger Driver4 Open the MDI implant vial.**1.8 and 2.1 mm diameter implants: Carry implant to the site using the vial cap (It can be usedas a carrier to the patient’s mouth, as well as a beginningsurgical driver.) The 1.1 mm Pilot Drill is delicately placed over the entrypoint and lightly pumped up and down until the corticalplate is penetrated. No incision is necessary in most cases. After inserting the implant into the pilot opening throughthe attached gingiva, rotate clockwise while exertingdownward pressure. In extremely dense bone an extended penetrationmay be required. Optionally, a 1.3 mm MDI drill (S1013.)may be necessary to further widen the drill channel. This procedure initiates the self-tapping process and isused until noticeable bony resistance is encountered. The Ratchet Wrench or Graduated Torque Wrenchwill then finalize the insertion process. Grasp the wrench (with the directional arrow facing clockwise)and engage the square neck of the Ratchet Adapter into thesquare opening of wrench. This final stage of MDI implant placement requires slow,carefully controlled ratchet turns. The ideal implant position allows the abutment headto protrude from the gingival soft tissue at its full lengthbut with no neck or thread portions visible.MDI TorqueRecommendations3.0 mm diameter MDI implants require use of Ø 2.0 mmSurgical drill (2012-01.). Optionally, in dense bonea Ø 2.6 mm Surgical drill (S1026.) may be necessaryto widen the drill channel. Do not exceed 45 Ncmduring implant placement. Advance the implant with the Torque Wrench to aminimum of 35 Ncm to allow immediate load. A minimum of 35 Ncmof resistance upon finalinsertion is recommendedfor immediate load. The average depth is one-third to one-half thethreaded length of the implant.Use of the Ratchet or GraduatedTorque Wrench with Ratchet Adapter If a resistance of at least 35 Ncm cannot be reached a temporarysoft-loading without metal housings is r ecommended.CAUTION IN DENSE BONE: If torque exceeds 45 Ncm unscrew the implantand deepen the drill hole to 2/3 of implant length. Recommended motor RPM 900 –1200S7007.8010.8070.5Final Implant PositioningA minimum of 4 MDI implants is required to stabilize a full lowerdenture.S1011.S1013. 2012-01. S1026.IMPORTANT: The removable o-ring attachments inside an over-denturewill not loosen an integrated MDI Implant. A loose implant is one that didnot fully integrate into the bone. The primary reason for non-integration isover-instrumentation of the bone. The MDI implant utilizes a fully self-tappingprotocol. It demands that the implant bite into the bone and advance itselffrom the initial point to completion. The procedure requires torquing forcesthat progress from the Finger Driver to the Winged Thumb Wrench to Ratchetor Torque Wrench with the Ratchet Adapter.Vial cap finger driver is provided with the implant packaging.**All MDI Implants are delivered sterile.Ideal Implant Position1415

MDI Mini Dental ImplantsImplant Surgical ProtocolsMaxillary Denture Stabilization3 Use of the Winged Thumb WrenchInsertion continues with the Winged Thumb Wrench.1Site Preparation2Entry points are made with the Pilot Drill (Item S1011.)by perforating the cortical plate.Use of the Finger DriverInsertion of the MDI implant begins with thevial cap and continues with the Finger Driveruntil more torque is necessary.S9032.4Use of the Ratchet or GraduatedTorque Wrench with the Ratchet AdapterTo verify initial stability is sufficient for each implant, connectthe Graduated Torque Wrench and confirm at least 35 Ncm ofresistance.If there is less than 35 Ncm of resistance – which might frequently be the case in maxillar bone – a temporary s oft-loadingwithout metal housings is recommended.2.4 mm diameter MDI implants require use of the1.1 mm Pilot Drill (Item S1011.).

MDI Mini Dental Implants Prosthetics Metal Housings MH-3. MH-2. MH-1. Metal Housing Micro Metal Housing O-Cap Ø Diameter 4.75 mm 4.3 mm 4.0 mm 3.5 mm 3.1 mm 3.1 mm Height 9 mm S1010. Blockout Shims Trim to appropriate length S1010. Blockout Shims (Pack of 25) Lab Analogs & Restorative Copings for 1.8 mm, 2.1 mm & 2.4 mm Implants 2921. 2924 .