V:\Technical\ARTWORK\Fitting & Wiring\Word Files COMPLETE\442073 W.docSentinelKinetic MVHR RANGEUser InstructionsStock Ref. N 443028L408449408451Kinetic VKinetic B RightKinetic B LeftKinetic BH RightKinetic BH LeftKinetic FH RightKinetic FH LeftKinetic Plus B RightKinetic Plus B LeftKinetic High Flow RightKinetic High Flow LeftSEE PAGE 16 FOR SPARE FILTERSPLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.442073 W.docCopyright 2009 Vent-Axia Limited. All rights reserved.

SAFETY INFORMATION AND CONTENTSIMPORTANT SAFETY INFORMATIONContentsPLEASEREAD THESEPLEASE READ THESEINSTRUCTIONSCAREFULLYINSTRUCTIONS CAREFULLYBEFORE USINGTHE THEUNIT. UNIT.BEFOREUSING1. This appliance is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities, orlack of experience and knowledge, unlessthey have been given supervision orinstruction concerning use of the applianceby a person responsible for their safety.Young children should be supervised toensure that they do not play with theappliance.2. Do not attempt to remove the covers ofthis unit. High Voltage is present in this unit.IMPORTANT SAFETY INFORMATION . 2NEW PROPERTY FILTER MAINTENANCE . 2Product Description3Sentinel Kinetic Sentinel Kinetic F Sentinel Kinetic Plus & SentinelKinetic High Flow . 3Control Unit Display . 6Powering Up the Unit . 8Startup Screens . 8Operation and Monitoring9Overview . 9User Menu Screens . 10Boost & Purge Screens. 12Status Message Screens . 13Maintenance15Caring for the Unit. 15Filter Maintenance . 1512 Monthly Maintenance . 15Troubleshooting17NEW PROPERTY FILTER MAINTENANCEDiagnosing a Problem. 17When fitted to a new build property thesupply and exhaust filters should bechecked at one month intervals for the firstsix months.Appendix One: Control Mode 02 Description18Overview . 18Airflow Mode Selection . 18Appendix Two: Spare Filters19DisposalThis product should not be disposed of withhousehold waste. Please recycle wherefacilities exist. Check with your local authorityfor recycling advice.Software Ver 39Sentinel Kinetic MVHR User Instructions2

Technical SpecificationProduct DescriptionSentinel Kinetic Sentinel Kinetic F Sentinel Kinetic Plus & Sentinel Kinetic High FlowThe Vent-Axia Sentinel Kinetic, Sentinel Kinetic F, Sentinel Kinetic Plus & Sentinel Kinetic High FlowMechanical Ventilation/Heat Recovery (MVHR) are heat recovery units designed for the energy efficientventilation of houses and similar dwellings, conforming to the latest requirements of the Building Regulationsdocument F 2010.The units are designed for continuous 24 hour exhaust ventilation of stale moist air from bathrooms, toilets andkitchens. As the stale air is extracted, a heat exchanger within the unit transfers up to 90% of the heat into thesupply air entering the bedrooms and lounge.Fig 1: Sentinel Kinetic Right handedFig 2: Sentinel Kinetic F, Sentinel Kinetic Plus and High FlowRight handedFig 3: Sentinel Kinetic Left handedSentinel Kinetic MVHR User InstructionsFig 4: Sentinel Kinetic F, Sentinel Kinetic Plus and High FlowLeft handed3

Technical SpecificationSentinel Kinetic Range Summer By Pass Models.The Sentinel Kinetic B, BH, FH, Plus B, Plus BH and High Flow are fitted with a Summer By Pass (SBP) and willprovide energy-free cooling when the house temperature and ambient temperature allows.Note that the volume of air provided by this ventilation system is a fraction of that required for space heating orspace cooling and will not in itself be sufficient to cool a room. It will however, provide a contribution and make adifference.There are three operating modes, Normal, Evening Purge and Night-time purge.Normal Mode.Air flow rate is determined by sensors, boost and timing settings, otherwise is normal rate.If the room is warmer than the set (shown as "indoor") temperature (i.e. you need the room to be cooler) and theoutdoor air is cooler than the actual room temperature (i.e. the outdoor air could cool your room) then the SBP willopen and the unit will supply cooler air to your room.Note that the above only applies whilst the outdoor air temperature is above 14 C (adjustable) in order to preventcold draughts.The set ("indoor") temperature should be set 2 or 3 degrees higher than the central heating thermostat and 2 or 3degrees below any air conditioning thermostat if fitted. This will prevent any clash between the separate systems.Evening purge Mode.Intended for use as the outdoor temperature cools in the evening, but reverts to normal control after a set time sothat any increase in noise is avoided overnight.Air flow rate is always at boost.The bypass closes and the purge stops if the temperature conditions described in Standard Mode are no longermet or 5 hours after the bypass opened.Night-time purge Mode.Intended for use as the outdoor temperature cools in the evening and continues through the night when cooling isa higher priority than any increase of noise. Note that the air noise in your system is influenced by the ductingdesign and layout and the size and type of vents used in the rooms. If improvements are required speak to yourinstaller.Air flow rate is boost.The bypass closes and the purge stops if the temperature conditions described in Standard Mode are no longermet.Sentinel Kinetic MVHR User Instructions4

Technical SpecificationModels 438342 - Sentinel Kinetic V without summer bypass.438222 - Sentinel Kinetic B Right right handed with summer bypass.438222L - Sentinel Kinetic B Left left handed with summer bypass.443319 - Sentinel Kinetic BH Right right handed with summer bypass and integral humidity sensor.443319L - Sentinel Kinetic BH Left left handed with summer bypass and integral humidity sensor.408167 - Sentinel Kinetic FH Right right handed with summer bypass and integral humidity sensor.408169 - Sentinel Kinetic FH Left left handed with summer bypass and integral humidity sensor.443028 - Sentinel Kinetic Plus B Right right handed with summer bypass and integral humidity sensor.447938 - Sentinel Kinetic Plus B Left left handed with summer bypass and integral humidity sensor.408449 - Sentinel Kinetic High Flow Right right handed with summer bypass and integral humidity sensor.408451 - Sentinel Kinetic High Flow Left left handed with summer bypass and integral humidity sensor.Accessories 441838 441865 437827 441780 442367 442368 443283 447340 409761 -Sentinel Kinetic Plug-in integral humidity sensorWireless enable kit (consists of wireless receiver and one wireless switch).Additional wireless switch (up to four may be connected).Vent-Wise accessory pack – requires sensors.Monza System Cooker Hood 600mm wideLatina System Cooker Hood 900mm wideWired Remote Control.Opto-CouplerSpigot Adaptor Kit 200mm (High Flow)A range of sensors can be used to manage system demand and control the ventilation rate. These include an internalhumidity sensor, humidity sensors for independent mounting in rooms, wireless receiver and wireless boost switches,CO2 sensor, Ventwise sensors, manual switches and pull cords. For these alternative control options, see www.ventaxia.comSentinel Kinetic MVHR User Instructions5

Technical SpecificationControl Unit DisplayThe Control Unit is located at the front of the Sentinel Kinetic unit. The Control Unit provides the user interfacefor commissioning and monitoring purposes.Figure 3: Control UnitDisplayThe main display is an LCD with automatic backlight,which is turned off to minimise power consumptionwhen the unit is operational (see Overview on page 9).Normal Airflow30%ButtonsFour buttons on the Control Unit provide the controls for configuring and monitoring the unit.Table 1: Control Unit ButtonsButtonFunctionPress to adjust settings and press to save settings.Press to go to the above screen or to increase a parameter value. Pressand hold for more than 2 seconds for fast scrolling.Press to go to the next screen or to decrease a parameter value. Press andhold for more than 2 seconds for fast scrolling.Press to activate Boost mode.No. of pressesBoost action(Control Mode 01)1Boosts for 30 minutes2Boosts for 60 minutes3Boosts continuously4Back to Normal flow ratePress and hold for 5 seconds to activate Purge mode. (Press and hold for5 seconds to cancel Purge).N.B Additional airflow modes are available from thebutton when Control Mode 02 is selected in thestart-up screens see Appendix One for further details.Sentinel Kinetic MVHR User Instructions6

Technical SpecificationPerformanceAirflowSentinel KineticSentinel Kinetic FSentinel Kinetic PlusSentinel Kinetic High FlowMaximum, FID,Maximum, FID,Maximum, FID,Maximum, FID,290 m3/h335 m3/hLowdefault 20%Normal default 30%Boost default 50%Purge 100%500 m3/hLowdefault 20%Normal default 30%Boost default 50%Purge 100%650 m3/hLowdefault 20%Normal default 30%Boost default 50%Purge 100%Lowdefault 20%Normal default 30%Boost default 50%Purge 100%Sound Levels20 dB(A) (normal)(@ 3 m)TBC24 dB(A) (normal)28 dB(A) (normal)34 dB(A) (boost)35 dB(A) (boost)36 dB(A) (boost)PowerAC Voltage Input220-240 V AC (single phase)AC FrequencyInput50 Hz nominalSupply Fuse3 A (located in fused spur)Product Fuse2 A (located on main PCB)Rated Power150 W (max.)180 W (max.)190 W (max.)360 W (max.)Height (excludingspigots)550 mm550mm630 mm630 mmWidth (excludingspigots)550 mm555mm775 mm775 mmDepth285 mm350mm524 mm including filterflap hinge protrusion524 mm including filter flaphinge protrusionWeight15 kg19 kg24 kg38 kg125 mm125 mm150 mm180 mmPhysicalSpigot diameterCondensate pipediameter22 mmEnvironmentalIP RatingIP22OperatingTemperature-20 C to 45 CAir IntakeTemperatureAs aboveOperatingHumidity0% to 95% RHStorageTemperature-20 C to 45 CStorage Humidity0% to 95% RHSoftware VersionV39For all other technical details, please see the Product Catalogue or our website at www.vent-axia.com.Sentinel Kinetic MVHR User Instructions7

Starting UpPowering Up the UnitSwitching On(The unit is designed to run continuously)To switch the unit on:1.Switch on the power at the mains supply isolator feeding the unit.2.Following switch-on, the fan motors will start and the Control Unit will display a series of startup screens,described below.Switching OffTo switch the unit off: at the unit’s local isolator, turn the power off.Startup ScreensSentinel Kinetic Version ScreenThe Sentinel Kinetic Version screen displays thefirmware version number for 3 seconds.V--No adjustments are possible on this screen.Language ScreenThe Language screen displays the language used forthe screens. It is typically displayed for 5 seconds, orlonger if changing the setting.LanguageEnglishControl Mode ScreenSelects between Control Mode 01 operation describedherein and the alternative Control Mode 02 describedin Appendix One.Control Mode01Airflow Units ScreenThe Airflow Units is a percentage of the unit’smaximum flow.Airflow Units%Wireless Control ScreenThe Wireless Control screen automatically displayswhether the wireless boost control switch is fitted. It istypically displayed for 3 seconds.Wireless ControlNot FittedHumidity Sensor ScreenThe Humidity Sensor screen displays whether thehumidity sensor is fitted. It is typically displayed for3 seconds.Sentinel Kinetic MVHR User InstructionsHumidity SensorNot Fitted8

Operation and MonitoringOperation and MonitoringOverviewWhen the Sentinel Kinetic unit has been installed and commissioned it should require no further intervention in order to operate,unless external switches are used to control on/off/boost, etc, or BMS control requires user action.Start-up ScreensV-LanguageEnglishControl Mode01Airflow Units%Press for BoostBoost Airflow50%Purge100 %120 mStatusWireless ControlNot FittedDryout Mode168 hHumidity SensorNot FittedDefrost ActiveAirflow ModeRoom Too ColdFan OffUser MenuNormal Airflow30%BMSFan OffCVP ControlSwitched OffPress for 5 sSet ClockMon 12:30Low Airflow20%Low Speed – If timer selectedon installation.Cooker Hood100 %Summer ModeOnIndoor Temp25 COutdoor Temp14 CTimeout after 2 mSentinel Kinetic MVHR User Instructions9

Operation and MonitoringUser Menu ScreensFrom the Normal Airflow screen, press thebutton to access the rest of the User Menu screens.Changing the value of a setting (if adjustable) is typically a 3-step procedure:1.Press2.orbuttons to adjust the value. To scroll quickly, press and hold theUse themore than 2 seconds.3.Pressto select the setting (the setting will flash).orbuttons foragain to enter the new settings and move to the next screen.To return to the Normal Airflow screen, press thebutton repeatedly or press and hold thebutton for 5seconds. Alternatively, the Normal Airflow screen will be restored if no buttons are pressed for two minutes(timeout). Settings are stored in a the memory and will be retained in the event of mains power supply failure.Low Airflow / Normal Airflow / Boost Airflow ScreenWhen the start-up screens are finished, the Low orNormal scre

443028 Kinetic Plus B Right 443028L Kinetic Plus B Left 408449 Kinetic High Flow Right 408451 Kinetic High Flow Left PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. SEE PAGE 16 FOR SPARE FILTERS . SAFETY INFORMATION AND CONTENTS Sentinel Kinetic MVHR User Instructions 2 IMPORTANT SAFETY INFORMATION PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THE UNIT