Proudly Made In The U.S.A. Warranty - ADA SOLUTIONS

Transcription

5-YearWarrantyProudly Made inthe U.S.A.Cast-In-Place (wet-set)Replaceable Tactilewww.adatile.com 800-372-0519

Cast-In-Place (wet-set)Replaceable Tactile2

Proudly Made inthe U.S.A.In stock colorsWhite37875Brick Red20109Yellow33538Blue15187Safety Red31350Seattle Yellow23594US Patents**www.adatile.com/patentsBlack37038Dark Gray36081Clay Red221443

Cast-In-Place Replaceable TactileInstallation ProcedureBe sure to read and understand all of these instructions before you begin.A.B.C.The physical characteristics of the concrete shall be as specified in the contractdocuments while maintaining a slump range of 4-7 inches to permit the solidplacement of the ADA Cast-In-Place Replaceable Tactile Unit (ADAREP) in thewet cement.The concrete shall be poured and finished level, true and smooth tothe required dimensions prior to the placement of the ADAREP unit.Place the ADAREP unit 6-8 inches from the curb line. Working in agrid pattern, tamp the ADAREP unit into the wet concrete using a rubbermallet and a piece of wood. Continue this process until all of the air hasbeen released, and the ADAREP unit surface is flush with the surrounding area.IMPORTANT: Avoid striking the surface of the ADAREP unit directly.D. Following the placement, the ADAREP unit elevation should be checked toE.F.Pull-Strength6200 P.S.I.the adjacent surface with a straight edge. The ADAREP unit elevation shouldbe consistent with the Contract Drawings and Specifications. Any requiredadjustments must be made prior to the time when the concrete begins to set.Important Notice to Installer: To allow for expansion and contraction,after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continousrun, be sure to space each unit 1/8” apart.When you are confident that the ADAREP unit is in place and no further adjustments are needed, place a cinder block on both ends, if necessary, to hold theADAREP unit in place while the concrete sets.G. During and after the ADAREP unit installation, as well as the concrete curingstage, no walking or external forces can be placed on the ADAREP unit. The areamust be protected from pedestrian traffic until concrete is cured. The ADAREPWarning Surface will be ready for pedestrian traffic within 2-4 hours.H. Be sure to remove plasticprotective covering from the faceof the ADAREP Unit once theconcrete is cured.*Not recommended or warrantied forasphalt installation.Do not cut Cast-In-Place Replaceable Tactile. Use an appropriatesized tactile or Radius Tactile to fit the requirement.Contact manufacturer for more details.4www.adatile.com 800-372-0519PRODUCT SIZES2’x3’ 2’x4’ 2’x5’3’x4’ 3’x5’APPLICATIONFresh PourConcrete Ramps& Replacement

Cast-In-Place Replaceable Tactile(WET-SET)Replacement ProcedureBe sure to read and understand all of theseinstructions before you begin.A.B.C.Lift the existing composite bolt cap from each anchor location on theADA Cast-In-Place Replaceable Tactile unit (ADAREP) with a flat headscrew driver.Remove the existing 1/2” x 1½” heavy duty steel bolts and washers fromeach anchor location on the ADAREP unit with a ratchet. Save & reuse.Tap around all sides of the ADAREP unit and across the middle with arubber mallet, working in a grid pattern.D. Pry the existing ADAREP unit from the concrete ramp with a smallprybar, working around the edges until it can be lifted cleanly away.E.F.Be sure to remove all small debris and dust from the existing impressionin the concrete ramp.IMPORTANT: Be careful not to get debris into anchor locations.Replace new ADAREP unit, of same size and orientation, into impressionin concrete ramp. Lightly tamp down the ADAREP unit with a rubbermallet and a piece of wood. Continue this process until the ADAREP unitis set firmly into existing impression in concrete ramp.IMPORTANT: Avoid striking the ADAREP unit directly.G. Bolt existing 1/2” x 1½” heavy duty steel bolts and washers back into eachanchor location on new ADAREP unit.H. Snap a new composite bolt cap provided, into each anchor locationon the ADAREP unit. The ADAREP unit is ready for pedestriantraffic immediately after installation is complete.View additional photos, drawings andspecifications on our website: www.adatile.com.Call (800) 372-0519 with any questions.US Patents**www.adatile.com/patentswww.adatile.com 800-372-05195

24.21.14.Cast-In-Place Replaceable TactileBBPATENT PENDING1.25034.286InlineDomePatternVIEW-D15 - EQUAL SPACESDOME GEOMETRYNOTE: US PATENT PENDING APPEARS ONTOP SIDE OF PART AS SHOWN.AIR VENTS AROUND THEOUTSIDE EDGES OF PANELVIEW -BPANEL DIMENSIONSCAP COVER.045 HIGHTYP.ADA Cast-In-PlaceReplaceableTactile units (ADAREP) are available in 24” x 36”,.900DIA. TYP.60.000 .50024” x 48”, 24” x DIA.60”,TOP36”x48”and36”x 60”sizes. ADAREP units may also be customOF DOMES1.375DIA.(4)configured to accommodate specific projectrequirements. ADAREP units measure1.125DIA.(4)¼” nominal thickness and feature a ⅜” thickx 1” wide perimeter “flange.”0.6250(4)0.875(4).090 DEG. POINTSRecessedAnchorLocation2.350In accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raisedtruncated domes with a diameter of nominal 0.9”, a height of nominal 0.2” and acenter-to-center spacing of 00.6252.350A durable exterior grade homogenous glass, carbon and fiberglass reinforcedcomposite material which is colorfast and UV stable. The color of the ADAREP unitis uniform throughout and does not rely on any type of paintR0.250coating to achieve color stability. Standard colors include: FederalTYP.Yellow, Seattle Yellow, White, Brick Red, Clay Red, Safety Red, Blue, Dark Gray and Black. For superior wheelchair, walkerHEX HEAD BOLTS & WASHER 4-PL.and shopping cart mobility, truncated domes have a center-to-center (horizontally and vertically) spacing of 2.35 inches.PHYSICAL CHARACTERISTICSCompressive StrengthFlexural StrengthWater AbsorptionSlip ResistanceFlame Spread IndexSalt SprayChemical Stain TestingAbrasion ResistanceAccelerated WeatheringTensile StrengthLoad Bearing at 16,000 lbs.Freeze/Thaw/Heat28,900 psi29,300 psi.07%1.18 Dry, 1.05 Wet20No Change (200 hours)No Deterioration549Delta E 5.0 (2,000 hours)11,600 psiNo DamageNo DisintegrationASTM D 695ASTM D 790ASTM D 570ASTM C 1028ASTM E 84ASTM B 117ASTM 1308ASTM C 501ASTM G 155ASTM D 638AASHTO-H20ASTM C 10265-YearWarrantyINCIDENTALSFasteners: ½” x 1½”heavy duty steelbolts and washers.Anchors: 1½” corrosionresistant concrete inserts.WARRANTYADAREP units shall be guaranteed in writingfor a period of five (5) years from date of contract’sfinal completion. The guarantee includes breakage anddeformation of the tactile warningsurface material.6www.adatile.com 800-372-0519ColorThroughout

VIEW -BDIA. TOP OF DOMES.450.090 DEG. POINTS.045 HIGH TYP.0.24534.286.900DIA. TYP.VIEW -B3 x SIZEDIA.(8)1.125DIA.(8)1.37560.000 SECTION A-ASIDE VIEW15 - EQUAL SPACES0.221.2009 - EQUAL SPACES24.00021.60014.4001.200VIEW-D0.967TOP VIEW0.5001.2500.2000.722www.adatile.com 800-372-05190.062HEX HEAD BOLTS & WASHER 8-PL.TYP.R0.250*www.adatile.com/patentsANOTE: U.S. Patents*CAP COVERUS PATENT # 7,779,5810.6250(8)A0.875(8)2.350VIEW - " D" 2 x SIZEFIELD DOT 7 DOME LAYOUT2.350AIR VENTS LOCATED ONTHE ENDS OF THE TWS UNITTACTILE WARNING SURFACEVIEW2436NV8REPPART NO.DATEwww.adatile.com(800)372-0519P.O. Box 3N.Billerica, Ma. 01862ADA-REP2436DRAWING NO.WET SET ADA STD REPLACEABLE TACTILEWARNING SURFACE UNIT8-BOLT LOCATIONS2.350" IN LINE TRUNCATED DOME PATTERNPART SIZE 24" x 36"PLANS AND DETAILSPROJECTSMC .429Cast-In-Place Replaceable Tactile24”x36” (610 x 914mm) Tile2.35” (59.7 mm) Dome Spacing7

Cast-In-Place Replaceable Tactile24”x48” (610 x 1219mm) Tile2.35” (59.7 mm) Dome Spacing0.2459.14291.25018.286.900DIA. (8)48.00020.5712.2869.142945.714TOP VIEW20 - EQUAL SPACESSIDE VIEWCAP COVERSECTION A-A60.000 1.375TYP.R 0.250HEX HEAD BOLTS & WASHER 8-PL.US PATENT # 7,779,581AAIR VENTS LOCATED ONTHE ENDS OF THE TWS UNIT*www.adatile.com/patentsNOTE: U.S. Patents*2.350VIEW - " D" 2 x SIZEFIELD DOT 7 DOME LAYOUT2.350AVIEW-D0.2000.722DIA. TYP.0.875(8)VIEW -B.090 DEG. POINTS.045 HIGH TYP.450DIA. (8)1.1250.6250(8)0.250(8)DIA. TOP OF DOMES0.500VIEW -B 3 x SIZEBOTTOMVIEWTACTILE WARNING SURFACESMC COMPOSITEMATERIALTRADEPROJECT2448NV8REPPART NO.DATEWET SET ADA REPLACEABLE TACTILEWARNING SURFACE UNIT8-BOLT LOCATIONS2.350" IN LINE TRUNCATED DOME PATTERNPART SIZE 24" x 48"PLANS AND DETAILSADA-REP2448DRAWING NO.www.adatile.com(800)372-0519P.O. Box 3N.Billerica, Ma. 01862www.adatile.com 800-372-051980.220.0621.2009 - EQUAL SPACES24.00021.60014.4001.2000.967

1.2009 - EQUAL SPACESVIEW -B0.2450.967DIA. TOP OF DOMES.450.090 DEG. POINTS.045 HIGH TYP.24.00021.60014.4001.200VIEW-D1.250.900DIA. TYP.0.22DIA.(11)VIEW -B 3 x SIZEDIA.(11)1.1251.37560.000 57.143CAP COVERSECTION B-BSIDE VIEW25 - EQUAL SPACESTOP VIEW13.7140.875(11)6.3140.50060.000TYP.R0.250HEX HEAD BOLTS & WASHER 11-PL.18.2866.314US PATENT # 7,779,581VIEW - " D" 2 x SIZEFIELD DOT 7 DOME LAYOUT2.350AIR VENTS LOCATED ONTHE ENDS OF THE PANEL*www.adatile.com/patentsNOTE: U.S. Patents*B2.350B0.2000.722www.adatile.com 800-372-05190.0620.6250(11)BOTTOM VIEWTACTILE WARNING SURFACE2460NV11REPPART NO.DATEwww.adatile.com(800)372-0519P.O. Box 3N.Billerica, Ma. 01862ADA-REP2460DRAWING NO.WET SET ADA REPLACEABLE TACTILEWARNING SURFACE UNIT11-BOLT LOCATIONS2.350" IN LINE TRUNCATED DOME PATTERNPART SIZE 24" x 60"PLANS AND DETAILSPROJECTSMC -In-Place Replaceable Tactile24”x60” (610 x 1524mm) Tile2.35” (59.7 mm) Dome Spacing9

Cast-In-Place Replaceable Tactile36”x48” (914 x 1219mm) Tile2.35” (59.7 mm) Dome SpacingA1.14318.28636.000PART O.A.PART O.A.20.571CAP COVERAAIR VENTS AROUND THEOUTSIDE EDGES OF PANEL1.14313.50013.50048.0002.28645.71420 - EQUAL SPACESB-BSIDE VIEWSECTIONDIA. (12)1.375TYP.R 0.250HEX HEAD BOLTS & WASHER 12-PL.U.S. Patents**www.adatile.com/patents2.350BOTTOM VIEWVIEW - " D" 2 x SIZEFIELD DOT 13 ON DOME LAYOUT2.35033.750VIEW-D0.24560.000 DIA. (12)1.1250.875(12)VIEW-B.900DIA. TYP.0.500.090 DEG. POINTS.045 HIGH TYP.0.2000.722.4500.0620.562VIEW -B 3 x SIZEQT'YSEE MATERIAL LISTPART NO.PART NO.MATERIAL LISTITEM DESCRIPTION3214SCALEAS NOTEDFULL SIZETRADEDETECTABLE WARNING SURFACEPROJECTMATERIALREV. NO.WET SET ADA REPLACEABLE TACTILEWARNING SURFACE UNIT2.375" IN LINE TRUNCATED DOME PATTERNPART SIZE 36" x 48"PLANS AND DETAILSDRAWING NO.www.adatile.com(800)372-0519P.O. Box 3N.Billerica, Ma. 01862www.adatile.com 800-372-0519100.6250(12)0.250(12)DIA. TOP OF DOMES0.9671.12515 - EQUAL SPACES1.125

www.adatile.com 800-372-0519.450.090 DEG. POINTS.045 HIGH TYP.0.245DIA. TOP OF DOMESVIEW-B0.967.900DIA. TYP.0.562VIEW -B 3 x SIZEDIA. (12)1.125DIA. (12)1.37560.000 SECTION B-BSIDE VIEW57.14320 - EQUAL SPACESCAP COVERHEX HEAD BOLTS & WASHER 12-PL.TYP.R 0.25016.000AIR VENTS AROUND THEOUTSIDE EDGES OF PANEL1.14313.500"B"13.50033.75036.000PART O.A.1.12515 - EQUAL 286*www.adatile.com/patentsU.S. Patents*2.350VIEW - " D" 2 x SIZEFIELD DOT 13 ON DOME LAYOUT2.350"B"0.2000.7220.6250(12)BOTTOM VIEWAS NOTEDFULL SIZEPART NO.SEE MATERIAL LISTQT'Ywww.adatile.com(800)372-0519P.O. Box 3N.Billerica, Ma. 01862DRAWING NO.REV. NO.WET SET ADA REPLACEABLE TACTILEWARNING SURFACE UNIT2.375" IN LINE TRUNCATED DOME PATTERNPART SIZE 36" x 60"PLANS AND DETAILSPROJECTMATERIALPART NO.MATERIAL LISTTRADEDETECTABLE WARNING SURFACESCALE4321ITEM DESCRIPTION(WET-SET)0.250(12)16.000Cast-In-Place Replaceable Tactile36x60” (914 x 1524mm) Tile2.35” (59.7 mm) Dome Spacing11

Product Information / Submittalwww.adatile.com 800-372-05194/13

5-Year the U.S.A. warranty Cast-In-PlaCe (wet-set) RePlaCeable taCtIle. Cast-In-PlaCe (wet-set) RePlaCeable taCtIle 2. Proudly Made in the U.S.A. In stock colors Blue 15187 Yellow 33538 Seattle Yellow 23594 Safety Red 31350 Dark Gray 36081 Clay Red 22144 Black 37038 White 37875 Brick Red 20109 US Patents*