Fuels, As Specified In ASTM D975, EN590 And ISO 8217 Www .

Transcription

www.rheotek.comSuitable for measuring gas oils, distillate fuels and dieselfuels, as specified in ASTM D975, EN590 and ISO 8217(marine fuels).The RHEOTEK AKV-diesel is a fully automated viscometer systemsuitable for measuring kinematic viscosity in full compliance with ASTMD445, IP71 & ISO 3104.Automated kinematic Viscometer – key featuresFully complies with ASTM D445Two measuring positionsAKVdieselThe RHEOTEKAKV- dieselprovides a reliableand precise methodfor measuring gasoils, distillate fuelsand diesels at 40ºC.Automatic flow timemeasurements aredetermined in highprecision ASTMUbbelohdeviscometer tubes.Remove cap and pour in samplePrecise ASTM Ubbelohde viscometer tubeswith independent ISO 17025 calibrationReported kinematicviscosity results arein full compliancewith ASTM D455, IP71 & ISO 3104.In-situ solvent cleaning and dryingUser friendly PC control systemThe AKV-dieselsystem is trulycompliant with ASTMD445 – usingstandard apparatusand automating themanual steps set outin the method.Furthermore,independentcalibration providesthe lowest possibleuncertainties ofmeasurement.The AKV system issuitable for otherapplications,including biodiesels.

Features of operation:FULL COMPLIANCE WITH METHODOLOGYDiesel fuels are required to be certified to international standards. These specificationsrequire kinematic viscosity to be measured in accordance with ASTM D445, IP71, or ISO3104. The RHEOTEK AKV-diesel strictly adheres to these methods, complying in everyrespect.Compliance to ASTM D 445 is achieved by using a glass capillary viscometer tube (ASTMUbbelohde design), in an automated assembly with each step of the method preprogrammed. This removes the possibility of deviating from the method, as well asensuring the most precise results.The powerful AKV-diesel software package records all flow time measurements and statesthe precision obtained for each result. Full traceability of measurements is provided.PRINCIPLE OF OPERATIONThe RHEOTEK AKV-diesel uses ASTM Ubbelohde viscometer tubes tomake precise flow time measurements. Each tube is independentlycalibrated with a certified constant, using calibration data produced bythe PSL ISO 17025 accredited laboratory. Samples are loaded into theviscometer, via the unique RHEOTEK filling station. An internal pumppushes the sample up into the capillary tube to position it formeasurement.The sample is released and the flow time is automatically measured bythe NiR optical detectors. On completion of the first run, the sample isonce again pushed up into the capillary tube, and a second consecutiveflow time is measured. The AKV-diesel software will then calculate thekinematic viscosity result.SAFE VACUUM (IN-SITU) CLEANING AND DRYINGOn completion of the measurement process, the AKV-diesel will automatically use a “safevac”system to clean and dry the Ubbelohde viscometer tube using suitable solvents. Thewaste sample and solvent is taken to a waste container, and the system is air dried,leaving it ready for the next sample.OPTIONSSeveral options are available for the AKV-diesel,including the RHEOTEK Smart Sampler. Thiscomprises of a XYZ auto sampler with disposable vials.Up to 52 sample positions.

AKV - dieselSYSTEM CONFIGURATIONSAKV-diesel with two measuring positions(AKV5002S):Modular system consisting of:Visibility bath2 measuring positionsAKV control/cleaning moduleASTM Ubbelohde viscometersAKV software & PC control card.SYSTEM PART NUMBERS:AKV5001S RHEOTEK AKV-diesel with ONE measuring positionAKV5002S RHEOTEK AKV-diesel with TWO measuring positionsAKV5003S RHEOTEK AKV-diesel with TWO measuring positions and XYZ auto samplerREQUIRED OPTIONS:PC systemLaboratory vacuum or vacuum pumpBath oilAKV - ASTM Ubbelohde Tube SizesTube RefAKV-0BAKV-1AKV-1CTube SizeRecommended Viscosity Range*0.005Viscosity range 0.5 to 3 mm²/s, cSt0.010Viscosity range 0.7 to 6 mm²/s, cSt0.030Viscosity range 1.05 to 18 mm²/s, cSt* Permitting use of ASTM D 445 kinetic energy correctionfor automated flow times 200s

www.rheotek.comTechnicalAKV-diesel SpecificationsOperating Temperature ºC40.00ºC (ot her temperatures available onrequest)Kinematic viscosity test methodsViscometer tubeSample volumeSample inductionTest durationCleaningLIMSElectricalManufacturerIP 71, ASTM D 445, ASTM D 446, ISO 3104,ISO 3105ASTM Ubbelohde. Options also for CannonFenske Routine and DIN Ubbelohde. AllViscometers supplied with ISO 1702512 mlSample is poured into a filling station abovethe viscometer - no syringe requiredTypically 12-15 minutes (test result within 5-7minutes)In-situ automatic cleaning. Cleaning solventmiscible with sample followed by dryingsolvent. Optimized cleaning parameters tominimize solvent usage whilst providing aCompatible110V or 220-240VAC, 50/60HzPoulten, Selfe & Lee Ltd - UKAKV-diesel 025AKV5030AKV5050PC system – complete with WINDOWSoperating systemMineral bath oilSilicone bath oilLaboratory vacuum pump - single stage (single ordual position AKV systems)Laboratory vacuum pump - dual stage (dualposition AKV system with XYZ auto sampler)PIAB vacuum pump (requires compressed airsupply)ASTM Ubbelohde size 1B (recommendedviscosity range 1.05 to 18 mm²/s. Complete withISO 17025 certificate of calibration.Spares kit including essential tools & spare parts

Thank you for reading this data sheet.For pricing or for further information, please contact us at our UK Office, using the detailsbelow.UK OfficeKeison Products,P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.Tel: 44 (0)330 088 0560Fax: 44 (0)1245 808399Email: sales@keison.co.ukPlease note - Product designs and specifications are subject to change without notice. The user is responsible for determining thesuitability of this product.

fuels, as specified in ASTM D975, EN590 and ISO 8217 (marine fuels). The RHEOTEK AKV-diesel is a fully automated viscometer system suitable for measuring kinematic viscosity in full compliance with ASTM D445, IP71 & ISO 3104. The RHEOTEK AKV- diesel provides a reliable and precise method for measuring gas oils, distillate fuels and diesels at 40ºC. Automatic flow time measurements are .