2019 Microsoft Corporation 2019 HERE - Revize

Transcription

MCImetroACCESS TRANSMISSION SERVICES CORP.D/B/A - VERIZON ACCESS TRANSMISSION SERVICESPROJECT:CLARIFICATION NO.PROJECT NAME:HINSDALE AND COUNTY LINE SCPROJECT #:1712ABDC.6 SL 001 UG R00PERMITTING AGENCYVILLAGEOF HINSDALEQUANTITY2122,846'2405 EA6302,730'640107'VICINITY MAPTABLE OF CONTENTS:1. COVER SHEET2. PROJECT CONTACT & NOTES SHEET3. F.O.C.U.S. SHEET4. CLARIFICATION SUMMARY SHEET5. SYMBOLS SHEET6. HANDHOLE DETAIL7. ADDITIONAL NOTES AND DETAILS8-13. PLAN VIEW14-19. (TC)DATE:TITLE: 1712ABDC.6 SL 001 UG R00PROJECT LOCATIONOUTSIDE PLANT CONSTRUCTIONMCImetroACCESS TRANSMISSION SERVICES CORP.HINSDALE, IL4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. HAZLETTREVISIONSDATE 2019 Microsoft Corporation 2019 HERESCOPE OF WORK- PLACE (5) 2.5' X 5' HANDHOLE- PLACE 2,846' OF 1-2" HDPE- DIRECTIONAL BORE 2,730'- OPEN TRENCH 107'DESCRIPTIONINITIALEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GrovePERMIT ID: 6520SCALEHORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:1OF1712ABDC.6 SL 001 UG R0019

GENERAL NOTESCONSTRUCTION NOTESPROJECT:1. ALL CONDUIT WILL BE 2" HDPEMCI COMPRISES THE FOLLOWING OPERATING ENTITIES:3. ALL WORK TO BE PERFORMED IN STRICT ACCORDANCE WITH THEAPPLICABLE CODES OR REQUIREMENTS OF ANY REGULATINGGOVERNMENTAL AGENCY, MCI BUSINESS,OR THE RIGHT-OF-WAY- GRANTOR.4. LOCATIONS OF SOME OF THE PHYSICAL FEATURES WERE OBTAINEDFROM DATED RAILROAD VALUATION MAPS OR OTHER DRAWINGS,AND MAY BE AS SHOWN OR DEPICTED ON THESE DRAWINGS.5. UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLERECORDS AND FIELD OBSERVATIONS, BUT ARE NOT NECESSARILYEXACT. THERFORE, UTILITY LOCATIONS WILL BE VERIFIED AT LEAST100 FEET IN ADVANCE OF TRENCHING OR PLOWING, SO THAT CHANGESIN CABLE PLACEMENT CAN BE MADE IN EVENT OF CONFLICTS.6. ALL KNOWN BURIED OBSTRUCTIONS ARE SHOWN ON THECONSTRUCTION DRAWINGS. ANY AND ALL OTHERS ENCOUNTERED AREALSO THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT,AND REPAIR, IF DAMAGED.7. ANY AND ALL IMPROVEMENTS, SUCH AS ASPHALT OR CONCRETEPAVEMENT, CURBS, GUTTERS, WALKS, DRAINAGE DITCHES,EMBANKMENTS, SHRUBS, TREES, GRASS SOD, ETC., IF DAMAGED,SHALL BE RESTORED TO ORGINAL OR BETTER CONDITION.8. EQUIPMENT TYPES SPECIFIED HEREIN (ie: "BACKHOE,"SWAMP PLOW", ETC.) ARE SUGGESTIONS ONLY AND ARE NOTINTENDED AS REQUIREMENTS. CONTRACTOR WILL BE NOTIFIED4. SHORING MAY BE REQUIRED AND SHALL COMPLY TOO.S.H.A. STANDARDS.5. ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36"MINIMUM COVER UNLESS SPECIFIED OTHERWISE ON THECONSTRUCTION DRAWINGS.6. MECHANICAL PROTECTION SHALL BE REQUIRED ANYTIMEA 36" MINIMUM COVER IS UNOBTAINABLE UNLESSSPECIFIED OTHERWISE ON THE CONSTRUCTION DRAWINGS.7. VERIZON BUSINESS PERSONNEL TO BE CONTACTED BY THECONTRACTOR 48 HOURS PRIOR TO CONSTRUCTION. SEECONTACT SHEET FOR CONTACT NAME AND TELEPHONENUMBER.8. ALL STATIONING IS BASED ON AS-BUILT INFORMATION,THEREFORE SOME VARIANCE SHOULD BE ANTICIPATED.ADJUST AS NEEDED.9. RAILROAD COMMUNICATION AND SIGNAL CABLES TO BELOCATED PRIOR TO CONSTRUCTION ACTIVITY. RAILROADTO BE GIVEN 48 HOURS NOTICE PRIOR TO CONSTRUCTION.10. ALL BURIED CABLE MARKER POSTS AND HARDWARE PLACEDAND/OR REMOVED ON ALL NEW AND EXISTING ROUTESSHALL BE IMPLEMENTED AS FOLLOWS:A. ON THOSE ROUTES THAT ARE CONSIDERED TO BE IN ANORTH TO SOUTH GEOGRAPHICAL ORIENTATION, THESOUTHERN-MOST SIGN AND POST SHOULD BE REMOVED.* FOR NEW ROUTES BEING CONSTRUCTED, ONE SIGN POSTWILL BE PLACED AT THE NORTH END OF EACH HANDHOLE.DATE:4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:ENGINEERING CONTRACTOROWNERSNAME OF FIRM: LEDCOR TECHNICAL SERVICESNAME OF FIRM: MCI METRO TRANSMISSION SERVICES CORP.D.B.A. VERIZON ACCESS TRANSMISSION SERVICESPROJECT MANAGER: DENNIS CLARKPHONE: (312) 453-8106PHONE: (312) 809-8183EMAIL: OSCAR.GUERRERO@ONE.VERIZON.COMNAME OF FIRM: LEDCOR TECHNICAL SERVICESCONSTRUCTION MANAGER: WAYNE SMITHPHONE: (312) 971-1488E. HAZLETTREVISIONSDATEDESCRIPTIONINITIALENGINEER: OSCAR GUERREROEMAIL: DENNIS.CLARK@LEDCOR.COMCONSTRUCTION CONTRACTORQUANTITY3. ALL UNDERGROUND OBSTRUCTIONS, WHEN LOCATED, WILLREQUIRE THE PLACEMENT OF A BURIED CABLE MARKERAND THE PLACEMENT OF 4" MANUFACTURED SPLIT PVC,BSP/GSP OVER OR UNDER EACH OBSTRUCTION.B. ON THOSE ROUTES THAT ARE CONSIDERED TO BE IN ANEAST TO WEST GEOGRAPHICAL ORIENTATION, THEWESTERN-MOST SIGN AND POST SHOULD BE REMOVED.* FOR NEW ROUTES BEING CONSTRUCTED, ONE SIGN POSTWILL BE PLACED AT THE EAST END OF EACH HANDHOLE.PROJECT CONTACTSCLARIFICATION NO.TITLE: 1712ABDC.6 SL 001 UG R002. ALL WORK TO BE DONE WITH EXTREME CAUTION !FIBER OPTIC CABLE IS CARRYING TRAFFIC AND LOSS OF SERVICEWILL RESULT IN LOSS OF REVENUE. CONTRACTOR SHALL NOT WORKIN A MANNER THAT MAY AFFECT TRAFFIC-CARRYING FACILITIES INTHE ABSENCE OF AN MCI EMPLOYEE OR CERTIFIED CONTRACTOR.2. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES48 HOURS PRIOR TO CONSTRUCTION ACTIVITY.OUTSIDE PLANT CONSTRUCTION- MCI COMMUNICATIONS SERVICES, INC.- MCI METRO ACCESS TRANSMISSION SERVICES CORP.- MCI METRO ACCESS TRANSMISSION SERVICESOF VIRGINIA, INC.- MCI METRO ACCESS TRANSMISSION SERVICESOF MASSACHUSETTS, INC.- METROPOLITIAN FIBER SYSTEMS OF NEW YORK, INC.MCImetroACCESS TRANSMISSION SERVICES CORP.1.EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GrovePERMIT ID: 6520CITY GOVERNMENTVILLAGE OF HINSDALECOMMUNITY DEVELOPMENT DEPT19 EAST CHICAGO AVEHINSDALE, IL SMPTO MPSHEETFILE:2OF1712ABDC.6 SL 001 UG R0019

MCI Outside Plant FOCUSF iber Optic C able U ncovering SystemFOCUS rules must be followed on all MCI projects involving work on or near MCI OSP facilities.Safety is MCI's number one priority; everyone must refrain from unsafe and improper practices.3)Review of FOCUS is mandatory at every Pre-bid, Pre-construction, site meeting and daily tailgatemeeting. FOCUS discussion must include site-specific history, unique problems, facility configurationsthat may be encountered, and past errors. "Those who do not learn from history are doomed to repeat it".Do not let this happen to you.4)5)Any work near or requiring handling of MCI Outside Plant facilities can only be performed with an MCIemployee or contract representative present -- THIS MEANS OUT OF HIS OR HER VEHICLE ANDDIRECTLY MONITORING THE WORK. The representative must have a properly operating cablelocator checked for accuracy every day prior to commencement of work (comparison of line and depthreadings to actual line and depth of the cable).·All Federal, State and local safety regulations must be followed without exception.·Personal protective equipment appropriate for the specific work site shall be used at alltimes. At a minimum, hard hat, safety shoes/steel toed boots and florescent orange orgreen work vest are required upon entering any MCI work site.·Use of intoxicants, drugs, inhalants or any other substances that may impair alertness arestrictly prohibited.·Contractors are NOT allowed to cut any cable. Cables scheduled for removal will be cutby MCI Operations personnel, and only after verification that all traffic has beenoff-loaded.CLARIFICATION NO.Locate and Pothole Requirements.·Prior to any excavation, the MCI employee or contract representative must verify the initial locatemarks completed by MCI Operations. Do not trust locate results completed by others! The MCIor contract representative must locate the cable running line by making at least one pass in eachdirection. Locate results must then be compared with previous marks and the asbuilts.··If the proposed work involves digging or excavating within 3 feet of the cable, the cable route will bemarked continually with orange paint and supplemented by marker flags placed every 10 ft. Theexcavation contractor must pothole (all potholes must be completed by hand digging or vacuumexcavation) a minimum of every 15 ft., then expose the entire length of the cable by hand digging orvacuum excavation.Extreme caution must be used at all times when working on or near active cables. AnMCI employee or contract representative must approve and be present prior to andduring all cable handling activities.·Tools and equipment specifically designed for the job at hand are required. USE THEPROPER TOOL FOR THE JOB.If the proposed work involves digging or excavating within 5 feet (but not closer than 3 feet) of thecable, the cable route will be marked continually with orange paint and supplemented by marker flagsplaced every 10ft. The excavation contractor must pothole the cable a minimum of every 15 ft.·Conduit work involving active cables requires specialized tools specifically designed toaccess ducts with active cables.If the proposed work involves digging or excavating within 15 feet (but not closer than 5 feet) of thecable, the cable route will be marked continually with orange paint and supplemented by marker flagsplaced every 10 ft. The excavation contractor must pothole the cable a minimum of every 30 ft.·Protecting MCI facilities IS EXTREMELY important; however, SAFETY regardingyourself and others is the most important part of any project.···6)DATE:The cable will also be potholed at any change in the running line of more than 1 ft. in any direction,anytime the accuracy of the electronic locate is questioned, or the marked running line does not matchthe as-builts.Exposing Requirements.·DRAWN BY:DATEE. HAZLETTDESCRIPTIONINITIALSignature:No mechanical excavation within 3 ft. of OSP facilities will be allowed unless the facilities have firstbeen properly located, potholed, positively identified, continuously exposed by hand digging orvacuum excavation, and the facilities are clearly visible.In addition, mechanical excavation within three feet of OSP facilities requires onsite prior approvalfrom MCI' s employee or contract representative.4/9/2019ENGINEER: LEDCOR GROUPREVISIONSEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.Release 1.0·QUANTITYTITLE: 1712ABDC.6 SL 001 UG R002)MCI Outside Plant Construction General RequirementsOUTSIDE PLANT CONSTRUCTIONThe title of this program, F.O.C.U.S., an acronym for Fiber Optic Cable Uncovering System was selectedto remind everyone involved with working near MCI's active fiber optic systems to focus on protectingthe facilities. If, during the course of the project, YOU notice any activity which may jeopardize the MCIOSP facilities, it is your duty to stop the work and re- FOCUSMCImetroACCESS TRANSMISSION SERVICES CORP.1)PROJECT:CRAN HUB:VZB Downers GrovePERMIT ID: 65207)Please refer to the latest edition of the MCI OSP Handbook for additional details . Know it and follow it.Release 1.0SCALEHORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:3OF1712ABDC.6 SL 001 UG R0019

PROJECT:CLARIFICATION NOTES (CONTINUED)CLARIFICATION NO.400500600700310315320330PLACE CONDUITPLACE HIGH DENSITY POLYETHYLENE (HDPE)ROCK ADDERSLURRY BACKFILL ADDEREXPOSE CONDUITEXPOSE CONDUIT AND RELOCATEEXPOSE CONDUIT AND REPLACE/SUBSTITUTEEXPOSE AND REMOVE CONDUITEXPOSE AND REMOVE CONDUIT (ABANDONED)CONCRETE ENCASEREMOVE CONCRETE ENCASEMENTREMOVE CONCRETE CAPPLACE HANDHOLEREMOVE EXISTING HANDHOLERELOCATE HANHOLEREPLACE/SUBSTITUTE HANDHOLEEXCAVATE SPLICE PITPLACE MANHOLEREMOVE EXISTING MANHOLERELOCATE PRECAST MANHOLEREPLACE/SUBSTITUTE PRECAST MANHOLECONSTRUCT WALLREMOVE AND RESTORE ASPHALTREMOVE AND RESTORE CONCRETEREMOVE AND RESTORE SIDEWALKREMOVE AND RESTORE CURBINGATTACH CONDUIT TO WALL OR STRUCTUREDETACH CONDUIT FROM WALL OR STRUCTURECORE BOREATTACH PULL/SPLICE BOX TO WALL OR STRUCTURE410411415420PULL CABLEPULL THROUGH DUCT (INNERDUCT)REMOVE CABLE FROM CONDUITREPOSITION ACTIVE CABLE SLACK510515516517520525526527528530535DIRECT BURY CABLEEXPOSE DIRECT BURIED CABLEEXPOSE DIRECT BURIED CABLE AND RELOCATEREMOVE AND DISPOSE OF CABLEPLACE AERIAL CABLERELOCATE AERIAL CABLEDELASH AERIAL CABLERELASH AERIAL CABLEREMOVE AERIAL CABLEPLACE POLE/PUSH BRACEREMOVE POLE/PUSH BRACE610620630640JETTING CONDUITEMBEDMENT PLOWDIRECTIONAL BOREOPEN TRENCH710PLACE BURIED CABLE MARKERS AND SIGNS/MWCOMWATER CROSSING SIGNSPLACE ISOLATOR/PROTECTION SYSTEM AT EXISTINGHANDHOLES/MANHOLESREMOVE BURIED CABLE MARKER POST/HARDWAREREMOVE CONCRETE BURIED CABLE MARKER POST711712714PROJECT CLARIFICATION SUMMARYCLARIFICATIONNUMBERCLARIFICATIONNUMBER AND ALPHA200212PLACE HIGH DENSITY POLYETHYLENE (HDPE)200240PLACE HANDHOLE600630DIRECTIONAL BORE600640OPEN 7'LF5 EA6302,730'640107'DATE:TITLE: 1712ABDC.6 SL 001 UG 5246247250252255256260270280281282JACK AND DRY BORE CONDUIT(S)OUTSIDE PLANT CONSTRUCTION2001102,846'240MCImetroACCESS TRANSMISSION SERVICES CORP.100QUANTITY2124/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. HAZLETTREVISIONSDATEDESCRIPTIONINITIALEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GrovePERMIT ID: 6520SCALEHORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:4OF1712ABDC.6 SL 001 UG R0019

BURIED CABLESTA.MKR. #STA.MKR. #STA.MKR. #STA.MKR. #STA.MKR. #PROPOSEDSTA.MKR. #STA.MKR. #PROPOSEDSTA.MKR. #PROPOSEDEXISTINGSTA.MKR. #EXISTINGSTEEL MARKER AND SIGN-(A)ALUMINUM "HUB"-STYLE MARKER-(B)FLAT MARKER-(C)TUBULAR MARKER-(D)TUBULAR MARKER, & ISOLATOR PROTECTOR-(E)STA.MKR. #EXISTINGSYMBOLS KEYPROJECT:(A)(B)(C)(D)(E)(A)(B)(C)(D)(E)AERIAL CABLE212121FOGWPERMIT TRACKING FORM IDENTIFIERP.T.F.P.T.F.18718742"42"42"42"DIRECT BURIED HDPEQUANTITYSTA.CLARIFICATION NO.STA.FOGWMILE POST MARKERNOTE:DASHED NOT FOUND IN FIELDSTA.FOGWIRE CABLESUBMSTA.SUBMSTA.STA.SUBMARINE CABLEPVC OR SPLIT PVC CONDUITROCK PROBE (DEPTH AS INDICATED)BSP/GSP OR SPLIT BSP/GSP CONDUITUTILITY COVER DEPTHSTEEL CASINGHANDHOLE, MANHOLE OR PULLBOX48''48''REMOVE AND RESTORE ASPHALT OR CONCRETEPOLEANCHOR ONLY(WIDTH AS INDICATED)GUY ONLYCORE BORE92' 10MOHG92' 10MOHGDBSIDEWALK ANCHOR AND GUYTRENCHINGFOREIGN ANCHOR AND GUYFUTURE CABLEPUSH BRACE (EXISTING POLE)REMOVE CABLE30'-5-8430'-5-84PBACCOUNT CODE CHANGE (BURIED TO AERIAL)TO BE REMOVED OR ABANDONED(SHOWN FOR HDPE)12"CULVERT (SIZE AS INDICATED)12"AERIAL UTILITY (ELECTRIC)BRIDGEUNDERGROUND UTILITY (TELEPHONE)MAIN TRACKSSIDEWALKSWSWEXISTING MCIMCIMCIDITCH LINED/LD/LTREESTAX DISTRICTIMCVEVENCPTODATE:4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:STREET LIGHTE. HAZLETTREVISIONSDATEDESCRIPTIONINITIALMANHOLEFIRE HYDCITY, COUNTY OR STATE BOUNDARY LINESTREET SIGNPROPERTY LINEFENCE LINERUGFIBEUGTIUNDERGROUNDCATCH BASINODBTIEOPDBAUEOPDIRECTIONAL BOREIALEDGE OF RLINECAUTION NOTEACBLDGAUBLDGCBUILDINGBUTI MCRO IPT IENIC D FC IBAB ELE RRAILROAD SIGNAL CONTROL BOXAUXILLARY TRACKSTITLE: 1712ABDC.6 SL 001 UG R00DBP ANCHOR AND GUYDIRECTIONAL BOREP JACK AND BOREOUTSIDE PLANT CONSTRUCTIONMCImetroACCESS TRANSMISSION SERVICES CORP.OVERHEAD GUY (ARROW IN DIRECTION OF PULL)STRUCTURE BELOW GROUNDF/LF/L F/LF/LF/L F/LSTRUCTURE ABOVE GROUNDGUARDRAILTOP OF SLOPETRAFFIC LIGHTS W/ EXTENDED ARMTOE OF SLOPESEWER LINESSSSWATER LINEWWSDSDEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GroveTRAFFIC LIGHT STUMPPERMIT ID: 6520STORM DRAIN LINEVALVEELECTRIC LINEGAS LINEEGEGSCALELAWN BASINHORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:5OF1712ABDC.6 SL 001 UG R0019

2.5' x 5' x 2.5' HANDHOLE DETAILSDETAIL "A"DETAIL "A-1"DETAIL "A-2"EXPLODED ISOMETRIC DETAILLOCK DOWN DEVICEENGAGED LOCKDOWN DEVICENEOPRENE RUBBER4'' X 1.50'' X .25''SEE DETAIL "A-3"THIS SHEETNON-SKIDSURFACE.1875'' SCREWWITH FLATWASHERATWO PIECE REINFORCEDPOLYMER MORTAR (RPM) COVER FOR20,000 LBS. LOADING WEIGHTPROJECT:.50'' STAINLESS STEELACME THD. BOLT &CAPTURE NUT W/STAINLESS END CAP(SELF CLEANING)NEOPRENE COVERACLARIFICATION NO.QUANTITYLIFTING SLOT4'' X 2'' WITH CENTER PINEMS MARKER3M CAT #1411(ONE SIDE ONLY)P1000 UNISTRUTSECTION A-A.75 IN.UNISTRUT CHANNELSUPPORT BEAM1.625'' X 1'' X 33''(3 REQUIRED)LOCKING DEVICECROSS SECTION.50 IN.DETAIL "A-3"COVER HOLD DOWN BRACKETOF 2-PIECE RPM COVERREINFORCEDPOLYMER MORTARCOVER AND FRAMELOCKING BEAM(CENTER ONLY)FIBERGLASS VAULT.75'' X 1.25'' HEX BOLTWITH NUT, AND WASHERFIBERGLASS REINFORCEDPLASTIC VAULT (FRP)''6030''4.75''COVER HOLD DOWNBRACKET (HOT DIPPEDGALV) (2 REQ'D)DETAIL "B"3'' REINFORCEDRIB30''VAULT BOTTOMPLAN VIEW(144 SQ. IN. TOTAL DRAINAGE)DETAIL "A-4"SUPPORT BEAMINSTALLATION(TYP. AT 6 PLACES)12''TYP.6''1'' DIA HOLEFOR GROUND ROD(TYP - 2 PL)6''12''TYP.4.50'' BELL ENDS W/ PVCPLUG. BELL ENDS TOACCOMODATE SCHED.40 PVC (BOTH ENDS)5.6LIFTING BOLTS (TYP. 4 PLACES)25''29.50''2'' KNOCKOUT (BOTH ENDS)RPM COVER6'' X 6'' DRAIN.50'' OPENING (MAX)(TYP - 4 PL)59.50''SUPPORTBEAMRPM FRAME2.50'' KNOCKOUT (BOTH ENDS)DATE:OUTSIDE PLANT CONSTRUCTIONSEE DETAIL "A-4"THIS SHEETMCImetroACCESS TRANSMISSION SERVICES CORP.SEE DETAIL "A-2"THIS SHEETREINFORCED POLYMERMORTAR FRAME (RPM)BONDED TO VAULT BYMANUFACTURERTITLE: 1712ABDC.6 SL 001 UG R00.375'' INSERT(TYP-4 PLACES)LS).375'' INSERT4/9/2019ENGINEER: LEDCOR GROUPDETAIL "C"DRAWN BY:DETAIL "D"EXCAVATION PITSIDE WALL VIEWINSIDE LOOKING OUT7' - 0''SUITABLE DIRTBACKFILL5' - 0''DATEDESCRIPTIONINITIAL7''7''EXISTING GRADEE. HAZLETTREVISIONS30''30''EMS MARKER(ONE SIDE ONLY)FIBERGLASSVAULT7''17''SUITABLE DIRTBACKFILL7''6''25.25'' MIN.HANDHOLE12''5' - 0''NOTES:2. BOTTOM OF EXCAVATED PIT TO BE BACKFILLED WITH 12''OF CRUSHED STONE (.75'' GRADE).4.75''25(TY ''P)CRUSHED STONEPVC, BSP/GSPOR HDPECONDUIT (TYP.).375'' LAG BOLTANCHOR (TYP.)1. VOID IN EXCAVATED AREAS TO BE BACKFILLED WITHSELECT MATERIAL.NOTE:LINEAR DISTANCE BETWEEN LAGBOLT ANCHORS MUST BE 25''.3. SHORING WILL BE REQUIRED.4. ALL HANDHOLES SHALL BE PLACED BELOW EXISTINGGRADE.5. THIS HANDHOLE IS OF FIBERGLASS MATERIAL,APROXIMATELY POUNDS IN WEIGHT. THE LIDS AREPOLYMER CONCRETE MATERIAL, EACH APPROXIMATELYPOUNDS.EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GrovePERMIT ID: 6520SCALEHORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:6OF1712ABDC.6 SL 001 UG R0019

PROJECT:CLARIFICATION NO.QUANTITYTYPICAL DETAILDIRECTIONAL BORE CROSS SECTION1-2" HDPE AT 36" DEPTH1-2" HDPETYPICAL DETAILPUBLIC UTILITY NOTE:CONTRACTOR SHALL NOTIFY ALL PUBLIC UTILITYCOMPANIES (GAS, ELECTRIC, TELEPHONE, SEWER,WATER, ETC) PRIOR TO COMMENCING ANYCONSTRUCTION.THESE COMPANIES WILL LOCATE, ON THE GROUND,THE LOCATION OF ALL CONDUITS, DUCTS,UNDERGROUND PIPING, ETC., ADJOINING &CROSSING PROPOSED CONSTRUCTION.TRENCH AND PLACE CONDUIT1-2" HDPE AT 36" DEPTHIF 2" OR LESS FROM EDGEOF PAVEMENT, REMOVE ANDINCLUDE IN REPAIR24''MIN.95% MIN. R.C. REPLACEMENTAC PAVEMENT TO BE 0.25' MINAND INCLUDE IN REPAIREXISTING GRADEDATE:12" MIN.36" MIN.COVER95% MIN. R.C. CLASS II BASE(IF EXISTING) MATCH EXISTINGTHICKNESS OR 6" MINBURIED CABLEMARKER TAPEOUTSIDE PLANT CONSTRUCTIONNOTE: DEPTH WILL VARYAND WILL BE ADJUSTEDTO A GREATER DEPTH ASEXISTING UTILITIES ARELOCATED AND DEPTHS AREPROVIDED BY LOCATOR.TITLE: 1712ABDC.6 SL 001 UG R0036" MINCOVERMCImetroACCESS TRANSMISSION SERVICES CORP.ADDITIONAL NOTES:1. EXCEPT AS OTHERWISE NOTED, CONTRACTORSHALL MAINTAIN A MINIMUM OF 24 INCHES OFSEPARATION FROM EXISTING UTILITIES.2. CONTRACTOR SHALL POTHOLE EACH UTILITY TODETERMINE SIZE, LOCATION, AND DEPTH PRIORTO CROSSING.3. CONTRACTOR IS CAUTIONED TO PROTECT SEWERMANHOLES, CATCH BASINS, LATERALS ANDINLETS.4. CONTRACTOR WILL PROVIDE BARRICADING TOINSURE CORRECT TRAFFIC CONTROL WHILEMAINTAINING VEHICULAR TRAFFIC AT ALL TIMES.5. RESTORATION TO BE IN COMPLIANCE WITH MCIAND APPLICABLE PERMITTING AGENCIES.6. BONDING AND GROUNDING PER NESC.EXISTING GRADE4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. HAZLETTREVISIONSDATEDESCRIPTIONINITIAL95% MIN R.C. 12" WIDEOR LESS USE 1-1/2SACK CEMENT SLURRY1-2" HDPEEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GrovePERMIT ID: 6520SCALEHORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:7OF1712ABDC.6 SL 001 UG R0019

W4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. DATE:SWROWROWSWCLROWCFSWSWN PARK AVEROWROWSWCLSWTITLE:1712ABDC.6 SL 001 UG R00CLCL2 00CLOUTSIDE PLANT CONSTRUCTION0 000 00E WALNUT STMCImetroACCESS TRANSMISSION SERVICES WROWROWROWSW1 00CLCLCL340'240CFE WALNUT STQUANTITY2124'x4' BORE PITCFCFCLARIFICATION NO.CFSWSWSWROWSWST: 1 01-PLACE NEW 2.5'X5'X2.5' HHREMOVE AND RESTORE SOD TOEQUAL OR BETTER CONDITION- BORE PITDBSWROWCFN PARK AVE1 00EXISITNG UNDERGROUND WOWEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CONSTRUCTION NOTES1PLACE 2.5' X 5' X 2.5' HANDHOLECODE 2402PLACE 340' 1-2" HDPECODE 2123DIRECTIONAL BORE 340'CODE 630CRAN HUB:VZB Downers GroveSEE SHEETS 6-7PERMIT ID: 6520- ADDITIONAL NOTES- PUBLIC UTILITY NOTES- BORE DETAILS- TRENCH DETAILS- HANDHOLE DETAILSSCALE0'1/2"1"HORIZONTAL:1" 40'VERTICAL:1" 40'MP0'20'SCALE40'TO MPSHEETFILE:8OF1712ABDC.6 SL 001 UG R0019

CLARIFICATION T: 5 13-PLACE NEW 2.5'X5'X2.5' HHREMOVE AND RESTORE SOD TOEQUAL OR BETTER CONDITION-BORE PITN ELM STSWCFROWROWCLPROJECT:DBDBDBSWCFRetaining WallCFCFE WALNUT STCF7 006 00CF5 004 00CLCLCLCLCLCLCLCLCFCF3 N ELM STDATE:CLSWCFROWCF4'x4' BORE PITDRAWN BY:ROWCFDATECLPLACE 545' 1-2" HDPECODE 2122DIRECTIONAL BORE 545'CODE 6303PLACE 2.5' X 5' X 2.5' HANDHOLECODE 240E. EER: LEDCOR GROUPCFROWCONSTRUCTION NOTESTITLE:1712ABDC.6 SL 001 UG R00SWSWSWSWSWOUTSIDE PLANT CONSTRUCTIONSWRetaining WallCLROWSWROWMCImetroACCESS TRANSMISSION SERVICES CORP.ROWROWROWEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GroveSEE SHEETS 6-7PERMIT ID: 6520- ADDITIONAL NOTES- PUBLIC UTILITY NOTES- BORE DETAILS- TRENCH DETAILS- HANDHOLE DETAILSSCALE0'1/2"1"HORIZONTAL:1" 40'VERTICAL:1" 40'MP0'20'SCALE40'TO MPSHEETFILE:9OF1712ABDC.6 SL 001 UG R0019

PROJECT:CLARIFICATION OWROWCF10 009 008 BDBCFCFCFCFCLCLCLCLCLCLCLCL12 0011 00ROWROWROWROWROWROWST: 9 03-PLACE NEW 2.5'X5'X2.5' HHREMOVE AND RESTORE SOD TOEQUAL OR BETTER CONDITION-BORE PITDATE:TITLE:1712ABDC.6 SL 001 UG R00E WALNUT STCFSWCFCFCFCFOUTSIDE PLANT CONSTRUCTIONSWMCImetroACCESS TRANSMISSION SERVICES CORP.ROWROW4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. HAZLETTREVISIONSDATE2PLACE 125' 1-2" HDPECODE 212DIRECTIONAL BORE 125'CODE 6303PLACE 2.5' X 5' X 2.5' HANDHOLECODE 2404PLACE 376' 1-2" HDPECODE 2125DIRECTIONAL BORE 376'CODE 630INITIALEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CONSTRUCTION NOTES1DESCRIPTIONCRAN HUB:VZB Downers GroveSEE SHEETS 6-7PERMIT ID: 6520- ADDITIONAL NOTES- PUBLIC UTILITY NOTES- BORE DETAILS- TRENCH DETAILS- HANDHOLE DETAILSSCALE0'1/2"1"HORIZONTAL:1" 40'VERTICAL:1" 40'MP0'20'SCALE40'TO MPSHEETFILE:10OF1712ABDC.6 SL 001 UG R0019

N OAK STPROJECT:SWROWSWROWST: 17 34-PLACE NEW 2.5'X5'X2.5' HHREMOVE AND RESTORE SOD TOEQUAL OR BETTER CONDITION-BORE PITCFTUNNEL UNDER EXISTINGSIDEWALK AND PROTECTIN PLACE.CLCFSWSWROWSWROWN OAK STROWROWCLSWROWSWSWSWROWSWSWDBTITLE:1712ABDC.6 SL 001 UG R00CFSWSWDBDBDBDBDBCLCLCFCFCFCFDB17 00CLCLCLCLCLCLCLE WALNUT STOUTSIDE PLANT CONSTRUCTIONCL14 0013 0049'ROWROW16 0015 CESS TRANSMISSION SERVICES CLARIFICATION NO.DATE:4/9/2019SWCFSWDRAWN BY:CFSWENGINEER: LEDCOR GROUPE. HAZLETTREVISIONSDATEDESCRIPTIONINITIALCLROWEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CONSTRUCTION NOTES1PLACE 455' 1-2" HDPECODE 2122DIRECTIONAL BORE 455'CODE 630345PLACE 2.5' X 5' X 2.5' HANDHOLECODE 240OPEN TRENCH 49'CODE 640PLACE 49' 1-2" HDPECODE 212CRAN HUB:VZB Downers GroveSEE SHEETS 6-7PERMIT ID: 6520- ADDITIONAL NOTES- PUBLIC UTILITY NOTES- BORE DETAILS- TRENCH DETAILS- HANDHOLE DETAILSSCALE0'1/2"1"HORIZONTAL:1" 40'VERTICAL:1" 40'MP0'20'SCALE40'TO MPSHEETFILE:11OF1712ABDC.6 SL 001 UG R0019

CFSWSWCLSWCFE WALNUT STCLCLCLCFCFSW20 00CFSWROWSWROWSWROWSWROWMCImetroACCESS TRANSMISSION SERVICES CORP.CFSWSWROWROW4'x4' BORE PITDBCLN COUNTYLINE RDROWDATE:CFDB4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. HAZLETTREVISIONSDATEROWCFCLCFDB21 00ROWCFROWTUNNEL UNDER EXISTINGSIDEWALK AND PROTECTIN PLACE.TITLE:1712ABDC.6 SL 001 UG R00SWOUTSIDE PLANT CONSTRUCTIONCFCFDBDBSWE WALNUT STCLCLGMSW321'SWCLCLCL379'630ROWSWROWROWROW19 0018 0058'212CFROWSWSWCFQUANTITY640SWROWCLARIFICATION NO.SWCFSWSWROWSWN COUNTYLINE RDPROJECT:DESCRIPTIONINITIALCFEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CF22 00CFSEE SHEETS 6-7CLCONSTRUCTION NOTESCRAN HUB:VZB Downers GrovePERMIT ID: 65201OPEN TRENCH 58'CODE 6402PLACE 379' 1-2" HDPECODE 2123DIRECTIONAL BORE 321'CODE 630- ADDITIONAL NOTES- PUBLIC UTILITY NOTES- BORE DETAILS- TRENCH DETAILS- HANDHOLE DETAILSSCALE0'1/2"1"HORIZONTAL:1" 40'VERTICAL:1" 40'MP0'20'SCALE40'TO MPSHEETFILE:12OF1712ABDC.6 SL 001 UG R0019

CFROWCLARIFICATION NO.CFN COUNTYLINE WCF024 0SW4'x4' BORE PITCFCLDBSWCFROWROWCLDB0ROW25 0ROWDBCFDBCLSWCFROWDATE:CFCLDBCFCFCLSW0026 ROWROW4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:CFCLSWCFDATE028 0DESCRIPTIONINITIALCFCLCFE. HAZLETTREVISIONSROWSWVEAEVOGRLLHICF0027 SWCFCLSWCFSWSWROWROWSWROW4'x4' BORE PITST: 28 05-PLACE NEW 2.5'X5'X2.5' HHREMOVE AND RESTORE SOD TOEQUAL OR BETTER CONDITION- BORE PITTITLE:1712ABDC.6 SL 001 UG R00DBSWROWOUTSIDE PLANT CONSTRUCTIONROWCFMCImetroACCESS TRANSMISSION SERVICES CORP.23 00ROWCFSWROWSWCFCLDBROWROWCFROWEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CONSTRUCTION NOTES1PLACE 577' 1-2" HDPECODE 2122DIRECTIONAL BORE 577'CODE 6303PLACE 2.5' X 5' X 2.5' HANDHOLECODE 240CRAN HUB:VZB Downers GroveSEE SHEETS 6-7PERMIT ID: 6520- ADDITIONAL NOTES- PUBLIC UTILITY NOTES- BORE DETAILS- TRENCH DETAILS- HANDHOLE DETAILSSCALE0'1/2"1"HORIZONTAL:1" 40'VERTICAL:1" 40'MP0'20'SCALE40'TO MPSHEETFILE:13OF1712ABDC.6 SL 001 UG R0019

PROJECT:CLARIFICATION NO.QUANTITY TYPE I BARRICADETYPE II BARRICADETYPE III BARRICADEVERTICAL PANELDIRECTION INDICATORBARRICADEDRUMVERTICAL BARRICADEDATE:TITLE: 1712ABDC.6 SL 001 UG R00TUBULAR MARKEROUTSIDE PLANT CONSTRUCTIONREFLECTORIZED CONEFOR NIGHTTIMEMCImetroACCESS TRANSMISSION SERVICES CORP.CONE FORDAYTIME4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:E. HAZLETTREVISIONSDATEDESCRIPTIONINITIALGENERAL NOTESDETECTABLE PEDESTRIANCHANNELIZING BARRICADETRAFFIC CONTROLDEVICESEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATIONS SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CRAN HUB:VZB Downers GrovePERMIT ID: 6520SCALESTANDARD 701901-07HORIZONTAL:NTSVERTICAL:NTSMPTO MPSHEETFILE:14OF1712ABDC.6 SL 001 UG R0019

PROJECT:CLARIFICATION NO.DATE:TITLE: 1712ABDC.6 SL 001 UG R00HIGH LEVEL WARNING DEVICEOUTSIDE PLANT CONSTRUCTIONMCImetroACCESS TRANSMISSION SERVICES CORP.WORK LIMIT SIGNINGSIGNS ON TEMPORARY SUPPORTSPOST MOUNTED SIGNSQUANTITY4/9/2019ENGINEER: LEDCOR GROUPDRAWN BY:HIGHWAY CONSTRUCTIONSPEED ZONE SIGNSE. HAZLETTREVISIONSDATEDESCRIPTIONINITIALWIDTH RESTRICTION SIGNFLAGGER TRAFFIC CONTROL SIGNTRAFFIC CONTROLDEVICESEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF M

mcimetro access transmission services corp. project #: 1712abdc.6_sl_001_ug_r00 vicinity map hinsdale, il project name: hinsdale and county line sc d/b/a - verizon access transmission services project location project: clarification no.quantity title: mcimetro access transmission services corp. outside plant construction1712abdc.6_sl_001_ug_r00 .