SPECIFICATIONSNI PXIe-7868RR Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express,6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM,Kintex-7 325T FPGAThis document contains the specifications for the NI PXIe-7868R. Specifications are typical at25 C unless otherwise noted.Caution Using the NI PXIe-7868R in a manner not described in this documentmay impair the protection the NI PXIe-7868R provides.Analog InputNumber of channels6Input modes (software-selectable;selection applies to all channels)DIFF, NRSE, RSEType of ADCSuccessive approximation register (SAR)Resolution16 bitsConversion time1 µsMaximum sampling rate (per channel)1 MS/sInput impedancePowered on1.25 GΩ 2 pFPowered off/overload4 kΩ minimumInput signal range (software-selectable) 1 V, 2 V, 5 V, 10 VInput bias current 5 nAInput offset current 5 nAInput couplingDCOvervoltage protectionPowered on 42 V maximumPowered off 35 V maximum

Table 1. AI Operating Voltage Ranges Over TemperatureMeasurement Voltage, AI to AI-Maximum Working Voltage(Signal Common Mode)Range (V) Minimum (V)1 Typical (V) Maximum (V) 10 10.37 10.5 10.63 12 V of ground 5 5.18 5.25 5.32 10 V of ground 2 2.07 2.1 2.13 8.5 V of ground 1 1.03 1.05 1.06 8 V of groundAI Absolute AccuracyAbsolute accuracy at full scale numbers is valid immediately following internal calibration andassumes the device is operating within 10 C of the last external calibration. Accuracies listedare valid for up to one year from the device external calibration.Absolute accuracy at full scale on the analog input channels is determined using the followingassumptions: TempChangeFromLastExternalCal 10 C TempChangeFromLastInternalCal 1 C number of readings 10,000 CoverageFactor 3 σTable 2. AI Absolute Accuracy (Calibrated)Range 10 V 5 V 2 V 1 V104.4105.9110.6118.4Gain Tempco (ppm/ C)20202020Reference Tempco (ppm/ C)4444Residual Offset Error (ppm of Range)16.416.416.416.4Offset Tempco (ppm of Range/ C)4.184.174.414.63INL Error (ppm of range)42.5246.5246.5250.52SpecificationsResidual Gain Error (ppm of Reading)12 The minimum measurement voltage range is the largest voltage the NI PXIe-7868R is guaranteedto accurately measure.ni.com NI PXIe-7868R Specifications

Table 2. AI Absolute Accuracy (Calibrated) (Continued)RangeSpecificationsRandom Noise, σ (µVrms)Absolute Accuracy at Full Scale (µV) 10 V 5 V 2 V 1 V26315690742,2831,170479252Table 3. AI Absolute Accuracy (Uncalibrated)RangeSpecifications 10 V 5 V 2 V 1 V2,9213,0213,0213,021Gain Tempco (ppm/ C)20202020Reference Tempco (ppm/ C)4444Residual Offset Error (ppm of Range)661671700631Offset Tempco (ppm of Range/ C)4.184.174.414.63INL Error (ppm of range)42.5246.5246.5250.52Random Noise, σ (µVrms)263156907436,89519,0187,6673,769Residual Gain Error (ppm of Reading)Absolute Accuracy at Full Scale (µV)Calculating Absolute Accuracy ( ) ( ) ( ℎ ( ℎ ) ( ℎ ) NI PXIe-7868R Specifications National Instruments 3

Refer to the following equation for an example of calculating absolute accuracy for a 10 Vreading.Absolute accuracy at full scale on the analog input channels is determined using the followingassumptions: TempChangeFromLastExternalCal 10 C TempChangeFromLastInternalCal 1 C number of readings 10,000 CoverageFactor 3 σ 104.4 ppm 20 ppm 1 4 ppm 10 164.4 ppm 16.4 ppm 4.18 ppm 1 42.52 ppm 63.1 ppm 263 µV 310, 000 7.89 µ 10 V ( ) 10 V ( ) 2, 283 µ DC Transfer CharacteristicsINLRefer to the AI Accuracy TableDNL 0.4 LSB typical, 0.9 LSB maximumNo missing codes16 bits guaranteedCMRR, DC to 60 Hz-100 dB4 ni.com NI PXIe-7868R Specifications

Dynamic CharacteristicsBandwidthSmall signal1 MHzLarge signal500 kHzTable 4. Settling TimeAccuracyRange (V)Step Size (V) 16 LSB 4 LSB 2 LSB 10 20.01.50 µs4.00 µs7.00 µs 2.00.50 µs0.50 µs1.00 µs 0.20.50 µs0.50 µs0.50 µs 101.50 µs3.50 µs7.50 µs 10.50 µs0.50 µs1.00 µs 0.10.50 µs0.50 µs0.50 µs 41.00 µs3.50 µs8.00 µs 0.40.50 µs0.50 µs1.00 µs 0.040.50 µs0.50 µs0.50 µs 21.00 µs3.50 µs12.00 µs 0.20.50 µs0.50 µs2.00 µs 0.020.50 µs0.50 µs0.50 µs 5 2 1Crosstalk-80 dB, DC to 100 kHz, at 50 ΩAnalog OutputOutput typeSingle-ended, voltage outputNumber of channels18Resolution16 bitsUpdate time1 μsMaximum update rate1 MS/sType of DACEnhanced R-2RNI PXIe-7868R Specifications National Instruments 5

Range 10 VOutput couplingDCOutput impedance0.5 ΩCurrent drive 2.5 mAProtectionShort circuit to groundOvervoltage protectionPowered on 15 V maximumPowered off 10 V maximumPower-on stateUser-configurablePower-on glitch1 V for 1 µsPower-down glitch3.7 V peak, decays to 0 V in 7 msTable 5. AO Operating Voltage Ranges for Over TemperatureMeasurement Voltage, AO to AO GNDRange (V)Minimum (V)2Typical (V)Maximum (V) 10 10.1 10.16 10.22AO Absolute AccuracyAbsolute accuracy at full scale numbers is valid immediately following internal calibration andassumes the device is operating within 10 C of the last external calibration. Accuracies listedare valid for up to one year from the device external calibration.Absolute accuracy at full scale on the analog output channels is determined using thefollowing assumptions: TempChangeFromLastExternalCal 10 C TempChangeFromLastInternalCal 1 CTable 6. AO Absolute Accuracy (Calibrated)Specifications 10 V RangeResidual Gain Error (ppm of Reading)87.3Gain Tempco (ppm/ C)12.6Reference Tempco (ppm/ C)26 4The minimum measurement voltage range is the largest voltage the NI PXIe-7868R is guaranteedto accurately measure.ni.com NI PXIe-7868R Specifications

Table 6. AO Absolute Accuracy (Calibrated) (Continued)Specifications 10 V RangeResidual Offset Error (ppm of Range)41.1Offset Tempco (ppm of Range/ C)7.8INL Error (ppm of range)61Absolute Accuracy at Full Scale (µV)2,498Table 7. AO Absolute Accuracy (Uncalibrated)Specifications 10 V RangeResidual Gain Error (ppm of Reading)2,968.6Gain Tempco (ppm/ C)12.6Reference Tempco (ppm/ C)4Residual Offset Error (ppm of Range)1,004.1Offset Tempco (ppm of Range/ C)7.8INL Error (ppm of range)61Absolute Accuracy at Full Scale (µV)40,941Calculating Absolute Accuracy ( ) ( ) ( ℎ ) ( ℎ ) ( ℎ ) Refer to the following equation for an example of calculating absolute accuracy for a 10 Vreading.Absolute accuracy at full scale on the analog output channels is determined using thefollowing assumptions: TempChangeFromLastExternalCal 10 C TempChangeFromLastInternalCal 1 CNI PXIe-7868R Specifications National Instruments 7

87.3 12.6 1 4 10 139.9 41.1 7.8 1 61 109.9 10 ( ) 10 ( ) 2, 498 µ DC Transfer CharacteristicsINLRefer to the AO Accuracy TableDNL 0.5 LSB typical, 1 LSB maximumMonotonicity16 bits, guaranteedDynamic CharacteristicsTable 8. Settling TimeAccuracyStep Size (V) 16 LSB 4 LSB 2 LSB 20.05.3 µs6.5 µs7.8 µs 2.03.2 µs3.9 µs4.4 µs 0.21.8 µs2.8 µs3.8 µsSlew rate10 V/µsNoise250 µV RMS, DC to 1 MHzGlitch energy at midscale transition 10 mV for 3 µs5V OutputOutput voltage4.75 V to 5.1 VOutput current0.5 A maximum8 ni.com NI PXIe-7868R Specifications

Overvoltage protection 30 VOvercurrent protection650 mADigital I/OTable 9. Channel FrequencyConnectorNumber of ChannelsMaximum FrequencyConnector 01610 MHzConnector 13280 MHzCompatibilityLVTTL, LVCMOSLogic familyFixedVoltage level3.3 VTable 10. Digital Input Logic LevelsLogic FamilyInput Low Voltage (VIL) MaximumInput High Voltage (VIH) Minimum3.3 V0.80 V2.00 VMinimum input-0.3 VMaximum input3.6 VInput leakage current 15 µA maximumInput impedance50 kΩ typical, pull-downTable 11. Digital Output Logic LevelsOutput Low Voltage (VOL)MaximumOutput High Voltage (VOH)Minimum100 µA0.20 V3.00 V4 mA0.40 V2.40 VLogic Family Current3.3 VMaximum DC output current per channelSource4.0 mASink4.0 mANI PXIe-7868R Specifications National Instruments 9

Output impedance50 ΩPower-on state3Programmable, by lineProtection4 15 V, single lineDirection control of digital I/O channelsPer channelMinimum I/O pulse width6.25 nsMinimum sampling period5 nsExternal ClockDirectionInput into deviceMaximum input leakage 15 µACharacteristic impedance50 ΩPower-on stateTristatedMinimum input-0.3 VMaximum input3.6 VLogic level3.3 VMaximum input frequency80 MHzReconfigurable FPGAFPGA typeKintex-7 325TNumber of flip-flops407,600Number of LUTs203,800Embedded Block RAM16,020 kbitsNumber of DSP48 slices840Timebase40 MHz, 80 MHz, 120 MHz, 160 MHz, or200 MHzDefault timebase40 MHzTimebase reference sourcePXI Express 100 MHz (PXIe CLK100)3410 Tristate by default.NI recommends minimizing long-term over/under-voltage exposure to the Digital I/O. ProlongedDC voltage stresses that violate the maximum and minimum digital input voltage ratings mayreduce device longevity. Over/under-voltage stresses are considered prolonged if the cumulativetime in the abnormal condition exceeds 1 year.ni.com NI PXIe-7868R Specifications

Timebase accuracy 100 ppm, 250 ps peak-to-peak jitterData transfersDMA, interrupts, programmed I/OOnboard DRAMMemory size1 Bank; 512 MBMaximum theoretical data rate800 MB/s streamingSynchronization ResourcesInput/output sourcePXI Trig 0.7 Input sourcePXI Star, PXIe DStarA, PXIe DStarB,PXI Clk10, PXIe Clk100, External Clock 1Output sourcePXIe DStarCBus InterfaceForm factorx4 PXI Express, specification v1.0 compliantSlot compatibilityx4, x8, and x16 PXI Express or PXI Expresshybrid slotsData transfersDMA, interrupts, programmed I/ONumber of DMA channels16Maximum Power RequirementsPower requirements are dependent on the digital output loads and configuration of theLabVIEW FPGA VI used in your application. 3.3 V3A 12 V2ANI PXIe-7868R Specifications National Instruments 11

Physical CharacteristicsIf you need to clean the device, wipe it with a dry, clean towel.Tip For two-dimensional drawings and three-dimensional models of the device andconnectors, visit ni.com/dimensions and search by model number.Dimensions18.5 cm 17.3 cm 3.6 cm(7.3 in. 6.8 in. 1.4 in.)Weight176.3 g (6.22 oz)I/O connectors3 68-pin VHDCIMaximum Working VoltageMaximum working voltage refers to the signal voltage plus the common-mode voltage.Channel-to-earth 12 V, Measurement Category IChannel-to-channel 24 V, Measurement Category IMeasurement Category I is for measurements performed on circuits not directly connected tothe electrical distribution system referred to as MAINS voltage. MAINS is a hazardous liveelectrical supply system that powers equipment. This category is for measurements of voltagesfrom specially protected secondary circuits. Such voltage measurements include signal levels,special equipment, limited-energy parts of equipment, circuits powered by regulated lowvoltage sources, and electronics.Caution Do not use the NI PXIe-7868R for connection to signals in MeasurementCategories II, III, or IV.Note Measurement Categories CAT I and CAT O (Other) are equivalent. These testand measurement circuits are not intended for direct connection to the MAINSbuilding installations of Measurement Categories CAT II, CAT III, or CAT IV.SafetyThis product is designed to meet the requirements of the following electrical equipment safetystandards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. 61010-1Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification section.12 ni.com NI PXIe-7868R Specifications

Electromagnetic CompatibilityThis product meets the requirements of the following EMC standards for electrical equipmentfor measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions EN 55022 (CISPR 22): Class A emissions EN 55024 (CISPR 24): Immunity AS/NZS CISPR 11: Group 1, Class A emissions AS/NZS CISPR 22: Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissionsNote In the United States (per FCC 47 CFR), Class A equipment is intended foruse in commercial, light-industrial, and heavy-industrial locations. In Europe,Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intendedfor use only in heavy-industrial locations.Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medicalequipment that does not intentionally generate radio frequency energy for thetreatment of material or inspection/analysis purposes.Note For EMC declarations and certifications, and additional information, refer tothe Online Product Certification section.CE ComplianceThis product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC)Online Product CertificationRefer to the product Declaration of Conformity (DoC) for additional regulatory complianceinformation. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in theCertification column.NI PXIe-7868R Specifications National Instruments 13

Shock and VibrationOperational shock30 g PK, half-sine, 11 ms pulse (Tested inaccordance with IEC 60068-2-27. MeetsMIL-PRF-28800F Class 2 limits.)Random vibrationOperating5 Hz to 500 Hz, 0.3 g RMSNon-operating5 Hz to 500 Hz, 2.4 g RMS (Tested inaccordance with IEC 60068-2-64. MeetsMIL-PRF-28800F Class 3.)EnvironmentalRefer to the manual for the chassis you are using for more information about meeting thesespecifications.Operating temperature(IEC 60068-2-1, IEC 60068-2-2)0 C to 55 CStorage temperature(IEC 60068-2-1, IEC 60068-2-2)-40 C to 71 COperating humidity (IEC 60068-2-56)10% RH to 90% RH, noncondensingStorage humidity (IEC 60068-2-56)5% RH to 95% RH, noncondensingPollution Degree2Maximum altitude2,000 mIndoor use only.Environmental ManagementNI is committed to designing and manufacturing products in an environmentally responsiblemanner. NI recognizes that eliminating certain hazardous substances from our products isbeneficial to the environment and to NI customers.For additional environmental information, refer to the Minimize Our Environmental Impactweb page at ni.com/environment. This page contains the environmental regulations anddirectives with which NI complies, as well as other environmental information not included inthis document.14 ni.com NI PXIe-7868R Specifications

Waste Electrical and Electronic Equipment (WEEE)EU Customers At the end of the product life cycle, all NI products must bedisposed of according to local laws and regulations. For more information abouthow to recycle NI products in your region, visit �制管理办法(中国 RoHS)中国客户 National Instruments �有害物质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录ni.com/environment/rohs china。(For information about China RoHScompliance, go to ni.com/environment/rohs china.)CalibrationRecommended warm-up time15 minutesCalibration interval1 yearOnboard calibration referenceDC level55.000 V ( 2 mV)Temperature coefficient 4 ppm/ C maximumLong-term stability 25 ppm/1,000 hNote Refer to Calibration Certifications at ni.com/calibration to generate acalibration certificate for the NI PXIe-7868RWorldwide Support and ServicesThe NI website is your complete resource for technical support. At ni.com/support, you haveaccess to everything from troubleshooting and application development self-help resources toemail and phone assistance from NI Application Engineers.Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, andother services.Visit ni.com/register to register your NI product. Product registration facilitates technicalsupport and ensures that you receive important information updates from NI.A Declaration of Conformity (DoC) is our claim of compliance with the Council of theEuropean Communities using the manufacturer’s declaration of conformity. This systemaffords the user protection for electromagnetic compatibility (EMC) and product safety. You5Actual value stored in Flash memoryNI PXIe-7868R Specifications National Instruments 15

can obtain the DoC for your product by visiting ni.com/certification. If your product supportscalibration, you can obtain the calibration certificate for your product at ni.com/calibration.NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,78759-3504. NI also has offices located around the world. For telephone support in the UnitedStates, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). Fortelephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information,support phone numbers, email addresses, and current events.Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks forinformation on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of theirrespective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in yoursoftware, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can findinformation about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Referto the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and howto obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES ASTO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.Government Customers: The data contained in this manual was developed at private expense and is subject to the applicablelimited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2017 National Instruments. All rights reserved.378036A-02May 3, 2017

NI PXIe-7868R R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 325T FPGA This document contains the specifications for the NI PXIe-7868R. Specifications are typical at 25 C unless otherwise noted. Caution Using the NI PXIe-7868R in a manner not described in this document