ANDERSEN DISCLAIMER - Amazon Web Services

Transcription

ANDERSEN DISCLAIMERThe Andersen A2 should only be installed by an electricianwith the appropriate knowledge and qualifications to carry outthis type of electrical installation. Failure to do so could resultin injury or death.It is the responsibility of the installer and/or designer todetermine the correct residual and overcurrent protectionwhere external influences could have an effect on inbuiltprotection.Opening of containment should only be carried out when thesupply is isolated from the mains. The undertaking any livetesting should only be carried out by a person or personsqualified to do so.The installation instructions should be followed closely toensure correct installation and commissioning. Failure tofollow these instructions could result in damage to theAndersen charger, existing installation or supplier’sequipment.During and on completion of the installation, the installationshall be inspected and tested to verify that it complies withthe latest amendment of the BS7671.Before the Andersen A2 is put into service, we as themanufacturer require the installer to simulate a charge with arecognised EVSE adaptor and multifunction tester.Use of this equipment should only be undertaken by someonewho has an understanding of its functions and has theexperience and knowledge to do so.1

ANDERSEN A2OPERATION LED STATUSr 111 ,, 1 "1 "' 1 .DDD DD DDDI2mm and 3mmallen keysscrewdriverphilips head(cross head) · . , . System powering up. Red, Amber, GreenLED flash together twice a secondStandby State (solid green)Vehicle connected state (solid green & solidamber)Vehicle charging state (solid amber)Charge point locked or awaiting scheduledcharge (solid green & solid red)ERROR & UPDATE LED STATUSwSETUP MULTI FUNCTION OPERATION Reset RCM (Two button presses)WEnter Network setup mode (Three button presses)WExit Network setup mode (One button press)WEnter unit reset mode (Five button presses) Exit Timeout 30 secsDisconnected from network/cloud (greenLED flash every 5 seconds). , ,, RCM or charge error (blip red every sec D D·I,,, . and) Firmware upgrade (sequence of green,amber, red for duration of upgrade)Ix29M3x16mmlong screwix2M5x12mmlong screwD . , . D1 V @x4M5x8mmcountersunk screwx26mmpennywasherSETUP LED STATUSWifi Setup (Amber LED flash once per second)81QUIP\rfTEU,lltW.,1 ,,"1@x26mmwasher- Reset warning. Red, Amber, Green LED flash Jl!I1 1" 4 times per second.Multi functionbutton locatedat the bottomleft inside thecable slot-. -.:- ;I 7:.-

Step 1: Installing A2 unit to wall@; m pennywasherIQ\x2 6mm washerwe don't providethese screwsTIP!Install top fixingsfirst then mark thebottom holes of theunitNotes:If the mountedsurface is uneven usespacers to ensurethe unit core is sittingflush to the wall

Step 2: Prepare A2 core for supplycable entryNote:this can be done on wallDefault cable entry isfrom the rear See Fig: 1000 )Bottom entry drill out cable entrysection with 20 25mm hole saw,see Fig :2Use rubber grommet from the rearcable entry holeFig 1Fig 1

Step 3: Terminate supply power cableSingle Phase installationENThree Phase installationTIP!Suggested cabletypes PVC orSWALlIncoming singlephase supply0000Incoming threephase supply&Important.Make sure thegland is tightenedafter cableinstallationNote:HI TUFF cable notrecommended, Itis very difficult toterminate

Step 4: Terminate sensor cablesSolar Advanced CTsensor cable* OptionalSolar Basic / AdaptiveFuse CT sensor cable* OptionalIf you have questions use ourhelpful support resourcesSolar Advanced CTNote: Fit CT clamp toPV inverter supply.Orientation can bedetermined duringtesting.Recommended Cable:Shielded twistedpair e.g. CAT5e/CAT6Solar Basic/Adaptive CTNote: Fit CT clampto incoming supply.Orientation can bedetermined duringtesting. CT orientation canbe confirmed indashboard using a loadreference i.e. kettle 3KwRecommended Cable:Shielded twistedpair e.g. CAT5e/CAT6 www.andersen-ev.com/support support@Andersen-ev.com 44 (0) 203 8904510 [[[IAndersen Chat

Step 5: Terminate vehicle sidecharging cableSingle Phase cableThree Phase cableImportant.Ensure cablestress reliefclamp iscorrectlytightened&Orange cable not usedImportant.Make surethe gland istightenedafter cableinstallation!

Step 6: Fit weather project coversx12M3 x 16mm longcountersunk screwsteel@@@Torque setting mu st be0.7Nm&@@A: Fit Output terminal coverEnsure seals are correctlypositioned and fixingscrews correctly torqued to0.7NmB: Flt input terminal cover@Ensure seals are correctlypositioned and fixingscrews correctly torqued to0.7NmC: Fit input supply coverEnsure seals are correctlypositioned and fixingscrews correctly torqued to0.7Nm

Step 8: Fit cable brushesx14M3 x 16mm longscrew --- &Secure side ---epanels byfitting brushpanels andfixing screwsto 0.7Nm.

Step 9: Fit lid panelx4MS x 8mm counter sunk screwA: Click lid panel into thelid coreB: Insert and tightenlid fixing screws@@@& lIII@ 1OC9 00@@0@ 0)@Note:For further tips andtricks see our supportvideos

Step 10: Fit bottom panelx3M3 x 16mm long screw0@@@@00I 0 Xi000 i0 @B: Tighten screws to 0.7Nm IA: Fit bottomcoverNote:For further tips andtricks see our supportvideos

Step 11: Fit front paneli \ /4x2MS x 12mm long screwi!, !lJ!eWl:.l ODDj-lcl ' 8 l l0 OUTPUr TIERMll'U.LCOVER@--&,:::'@"""'& · ) '-" '-----1.@ 0 0 :llt!PIIT @& '0) ,A: Ensure the frontpanel mounts arelocated into the slotscorrectlyl:1 /,B: insert and tightenfront panel screwscorrectly torqued to2.5Nm.

Technical DataMounting LocationIndoor/Outdoor permanent mounting on a suitable structureCharging ModeMode 3 (IEC 61851-1 compliant communication protocol) & RED compliantDisplayStatus lights- Green/Amber/RedInternal LightsCourtesy Lights- Warm White, Hall sensor operatedCharging CurrentSingle Phase/3 Phase units 6A to 32A Per PhaseVariable CurrentSingle Phase Only 6A-32A CT Monitored (Adaptive Fuse)Connector TypeType 2 tethered cable IEC 62196-2 compliant.ComplianceRED 2014/53/EU, LVD 2014/35/EU, EMC 2014/30/EU, EN 61851-1:2017,EN 62196, EN 62955:2018, ROHS 2011/65/EU, WEEE 2012/19/EU CECertified.Enclosure, core and plug compartment IP65/ Type 2 plug connector IP44with rubber cap in use.Humidity to 95% RH non condensing -25 Celsius to 45 Celsius.Ingress ProtectionOperating SpecificationSecurityEnclosure Core MaterialRemote software enabled charge point locking, 128-bit data SSL AESencryption for smart connectivity, Bluetooth with TLS encryptionRealtime health monitor system, Start-up self-test, Earth monitoring,Welded contactor monitor, PME monitoringPolycarbonate blendFinish MaterialAluminium Nylon Coated, Accoya woodShipped Weight15-16KgFault MonitoringElectrical SpecificationsRated Power7kW (1-phase) / 22kW (3-phase)Rated Supply Voltage230V AC Single Phase or 400V AC 3-Phase ( /- 10%)Rated Frequency50HzOperating Voltage207-253 VacRated Current32 AmpsO-PEN technologyConforming to 722.411.4.1 (iii) (iv)Earth Leakage ProtectionInternal 6mA DC protection (EN 62955)Standby Power8 WattsCT Sensor Voltage0.333VCT Sensor Specification0-120amps/25mm2 maximum cable size split coreEVOFLEK Charging Cable4mm2 Live Conductors/32a max current. High-performance ultra flexiblecable

InstallationMountingFlush mounting location using x4 fixing pointsCable EntryCable SizingRear/Bottom (Lower left Below Cable Terminations) 20mm removablecompression gland4mm2 – 10mm2Dimensions Unboxed494 x 348 x 148 mm (metal) 156mm (wood)HeightInstalled between 0.75m – 1.2m from ground levelCT Sensor CableMaximum extended length 30 meters unshielded CAT5/650 meters shielded CAT6 data cable.40a Type A RCBO (61009) or Type A RCD/RCCB (61008) 40a B curve MCB(60898)9.5Kg - 11.2KgUpstream ProtectionInstalled WeightDevice ConnectionInternet ConnectionWi-Fi - 802.11 b/g/n support, 802.11 n (2.4 GHz), up to 150 MbpsBluetoothBluetooth BLE 5 (setup only)Device SupportApple iOS mobile device/Android mobile devices

& DangerDanger to life due to electrical voltage! Injuries due to electric shockand/or burns, possibly resulting in death, are possible.During all work, make sure at all times that power to the system isswitched off and secured so it cannot inadvertently be switched on. Before commissioning the device check that all screw and terminalconnections are tight. The termination panel covers must never be left opened withoutsupervision. Fit the termination panel cover when you leave thecharge point. Do not make any unauthorised changes or modifications to thecharge point. Repair work to the charge point may only be completed by themanufacturer or a trained expert. Do not remove any identifiers such as safety symbols, warninginstructions, rating plates, labels or cable markings. Ensure that the charging cable is not mechanically damaged (kinked,jammed or run over) and that the contact area does not come intocontact with heat sources, dirt or water.& WarningSafety notice: Isolate all poles and from all live sources. Lock off to prevent re-energising of the supply. Verify isolation from the supply. Electrical saftey warning notices applied. Cover neighbouring live parts and cordon off danger areas.& CautionEnsure that the charge point is not damaged by incorrect handling(housing cover, internal parts, etc.).On outdoor installations, do not open the termination panel cover indamp conditions.Danger of breaking the plastic housing. Do not tighten the securing screws with force. The installation surface must be completely flat, do not bend thehousing. Electronic components may be damaged if handled. Before handlingmodules, perform an electrical discharge process by touching ametallic earthed object.A failure to follow the safety information may result in a danger of death,injury and damage to the device. The device manufacturer cannotaccept any liability for claims resulting from this.

ANDERSEN DISCLAIMER The Andersen A2 should only be installed by an electrician with the appropriate knowledge and qualifications to carry out this type of electrical installation. Failure to do so could result in injury or death. It is the responsibility of the installer and/or designer to determine the correct residual and overcurrent protection