StruxureWare Data Center ExpertTMData Center Infrastructure Management (DCIM) SoftwareEnd to end data center infrastructure management software formonitoring and control of power, cooling, security and energy usage fromthe building through IT systemswww.schneider-electric.com/dcim

StruxureWare for Data e Data Center ExpertInstant fault notification and escalation enablequick resolution of critical infrastructure events.Whether located in a data center, remote office, orcampus environment, Data Center Expert and theSchneider Electric power, cooling, environmental,and security devices combine to provide acomprehensive centralized monitoring solution.With Data Center Expert power readings,environmental readings and camera images fromany site on your network are tied in together into acommon management platform. Images and alertsfrom around the company can be instantly viewedand managed, trends analyzed, and problemsaverted, providing unparalleled physical threatmanagement.Integrated with Power and Building ManagementIntegrate with Building Operation and PowerMonitoring Expert for information on the healthof critical support systems in the electrical andmechanical rooms as well as power quality andelectrical distribution.Web Services APIReady access to Data Center Expert alerts, data,reports and trending through existing dashboardsor create custom portals for financial, operationalor other views.Data CenterExpertBase application Security (Surveillance)Modbus TCP OutSNMPDeviceSupportModbusTCP OutProduct modules &enhancement optionsData Center Expert is easy to use and deploy witha user-friendly interface to monitor, manage andcontrol the hundreds or thousands of devicesa company might have from a wide range ofmanufacturers. These devices include equipmentthat provides power, cooling, security andenvironmental monitoring.Centralized monitoring & alerts Multi-vendor support for monitoring anynetworked device from any manufacturer Real-time monitoring and instant fault notificationand escalation enable quick resolution of criticalinfrastructure events. Centralized repository of critical informationaccessible by multiple users from anywhere on thenetwork. Future trending for bringing new insightsinto your infrastructure’s health, planning andbudgeting. Customized alarming and escalation by device,by rack, or by location to the right people at theright time. Open and flexible architecture which expandswith changing business needs through additionaldevice licenses, add-on surveillance, operations,and control applications. Full software developer kit (SDK) allows formaximum flexibility through custom integrationwith other systems.

StruxureWare for Data Centerswww.schneider-electric.com/dcimStruxureWare Data Center ExpertFeatures and BenefitsManageabilityCentralized managementSimplify data center infrastructure management by using a centralizedrepository accessible from anywhere on the network through a powerfuland easy-to-use console application.Real-time monitoringImmediate visibility to your entire physical infrastructure throughcentralized, real-time device monitoring and notification enabling quickassessment of events as they occur.Fault notificationReal-time event notification minimizes response times to critical physicalinfrastructure situations. Enables IT Administrators to reduce mean timeto repair, improve efficiency, and maximize uptime.Multi-vendor device supportExtensive multi-vendor support for monitoring networked SNMPdevices. Enable visibility of existing SNMP devices through thresholdalert notifications, data trending and reporting.Unified consoleCustomizable Windows and Linux client application enables instantaccess to Data Center Expert application from anywhere on thenetwork.AgilityAuto-discoveryReduces the time needed to install and deploy physical infrastructuredevices by automatically detecting manageable devices on yournetwork.Mass configurationProvides a comprehensive mass configuration capability, allowing usersto create, save, and push configurations or specific device settings tosimilar APC devices with a Network Management Card.AvailabilityGraphical trending analysisAccess current and historic data for any device or group of devices. Plotand graph multiple data points in a logical correlation to visualizepotential hazardous trends.Custom reportingCreate, save and schedule user-defined reports for ease of datacollection, distribution and analysisCentralized alert repositoryAccess historical alerts from several appliances through one centraldatabase. Sort alerts by type, date, appliance, and/or device group.Integrated data storageAdditional storage can easily be made available using the built-inNetwork Attached Storage server support for long-term storage andarchiving.Localized user interfaceProvides a localized user interface including alerts and alert descriptionsin 10 local languages3

StruxureWare for Data Centerswww.schneider-electric.com/dcimStruxureWare Data Center andardAP9470EnterpriseVirtual MachineAP9475AP94VMTRL AP94VMACTUp to 325 deviceswith (1) CPU and(1) GB RAMUp to 1,025 deviceswith (1) CPU and(2) GB RAMUp to 2,025 deviceswith (2) CPU and(2) GB RAMUp to 4,025 deviceswith (4) CPU and(4) GB RAMUp to 250appliancesDevice Support (1 node 1 IP address)Up to 525devicesUp to 2,025devicesUp to 4,025devicesUp to 5devicesNetBotz Appliance Surveillance SupportUp to 15appliancesUp to 125appliancesUp to 250appliancesUp to 1applianceSupported Device TypesAll: UPS Models, Chillers, Power Distribution Units (PDU), Rack PDUs, ComputerRoom Air Conditioners, Environmental Sensors, Power Metering Equipment,Surveillance Appliances, Static Transfer Switches, Standby GeneratorsBuilding Management System IntegrationYesMulti-vendor SNMP and ModBus SupportYesPowerSingle supplyDual supplyn/aClient System & Web BrowserPrerequisitesOperating SystemMicrosoft Windows XP (SP1, SP2, SP3) Windows Server 2003 (SP2) Windows Vista, Windows 7, or Red Hat Enterprise, Linux 6.0 (32-bit platforms only)CPU SpeedSystem MemoryScreen Resolution1 GHz or better AMD/Intel processor1GB RAM1024 x 768Browser RequirementsThe browser must be JavaScript enabled, Mozilla Firefox version 12.0, 13.0, 14.0Microsoft Internet Explorer version 8.0, 9.0, 10.0 Google Chrome version 19.0,20.0, 21.0Communications & StorageOn-board RAM2GB2GB4GBData Storage160GBavailable fordata storage250GBavailable fordata storage1TB availablefor datastorageSupports VMware Fault Tolerancen/aSupports VMware High Availabilityn/aProtocolsDNS, HTTP, HTTPS, SMS, SMTP, SSL,TCP/IP, SNMP,Network Interface ConnectionsRJ-45 10/100/1000 Base-T* All Data Center Expert servers include 25 nodesSee “Supports VMware FaultTolerance” / “High Availability”18GB minimum (includes requiredspace for VM image and 1GB ofdata storage)(1) CPU, (1) GB RAM, up to 325devices(1) CPU, (2) GB RAM, up to 1,025devices(1) CPU, (1) GB RAM, up to 325devices(1) CPU, (2) GB RAM, up to 1,025devices(2) CPU, (2) GB RAM, up to 2,025devices(4) CPU, (4) GB RAM, up to 4,025devicesDNS,HTTP,HTTPS,SMS,SMTP,SSL,TCP/IP, SNMP, ModbusTCP4

www.schneider-electric.com/dcimStruxureWare for Data Centers5Peace-of-mind software servicesSchneider ElectricTM offers a comprehensive portfolio of services tosupport and enhance our StruxureWare for Data Centers software.These services are designed to simplify deployment, reduce costs,and address your key concerns and challenges. Our softwareservices provide you with peace of mind that your applications willreceive the care they need to operate at optimal levels at all times.Software Installation Ensures that all software products are installed correctly by ahighly skilled field service engineer and are quickly ready foruse in your dynamic data center.The Schneider Electric winningrecipe for service excellenceDedicated Resources Worldwide network of certified fieldSoftware Configuration Configures the system quickly and precisely to emulateyour unique data center, in turn allowing you to make criticaldecisions that will save you time and money.Software Support Contracts Ensures you stay up to date with the latest software releasesand technical supportservice engineers Available 24/7 Allows data center and facilities managersto focus on their day-to-day activitiesMethodology Our technical statements of work followa structured methodology of workSoftware Enhancement Provides customized dashboards and enhanced reports tomeet your business needs.Solution Deployment Management Provides a single point of contact to oversee the installation,configuration, integration, customization, and enhancement ofthe DCIM software solution.procedures that adhere to industrybest practicesExecution Deployment management Safety is a top priority Operation process compliance SchedulingSoftware Preventive Maintenance Grants on-site visits to review, analyze, detect, and preventsystem failures while optimizing the use of the DCIM tool.Software Integration Provides planning, designs, and project management for theintegration of StruxureWare for Data Centers software into yourexisting software or system, providing you with a customizedview into your existing applications.Tools Latest software updates Latest firmware updates Access to DCIM support HW equipmentPerformance Fast and efficient service deliverySoftware Education Offers hands-on training on key features, operational skills,and best practices, enabling you to get the most from yourDCIM. Highly trained resources ensureStruxureWare for Data Centers is operatingat optimal performance levels

www.schneider-electric.com/dcimStruxureWare for Data Centers6For more information.Additional ResourcesView videosVisit white papers.apc.comVisit tv.schneider-electric.com to watch ourStruxureWare for Data Centers videos and customertestimonials.Read more about the technology and research behindStruxureWare for Data Centers. www.youtube.com/user/SchneiderCorporate How Data Center Infrastructure Management SoftwareImproves Planning and Cuts Operational Costs (#107). tv.schneider-electric.com Avoiding Common Pitfalls of Evaluating andImplementing DCIM Solutions (#170).Read our Blogs Virtualization and Cloud Computing: Optimized Power,Cooling, and Management Maximizes Benefits (#118). Guidelines for Specification of Data Center PowerDensity (#120). Allocating Data Center Energy Costs and Carbon to ITUsers (#161). Estimating a Data Center’s Electrical CarbonFootprint (#66).Discussing challenges and trends of DCIM, andinviting you to join in. Blog.schneider-electric.com/datacenterFollow us on TwitterFor updates on all news on StruxureWare for DataCenters. www-twitter.com/StruxureWare DCNeed additional information?Check out our webpages or DCIMsupport for answersto your questions. www.schneider-electric.com/dcim DCIMsupport.apc.comWant to learn more about StruxureOn?https://struxureon.com/Boston ONE Campus800 Federal StreetAndover, MA 01810www.schneider-electric.com 2017 Schneider Electric. All rights reserved.

StruxureWare Data Center Expert Specifications Basic Standard Enterprise Virtual Machine SKU AP9465 AP9470 AP9475 AP94VMTRL AP94VMACT Device Support (1 node 1 IP address) Up to 525 devices Up to 2,025 devices Up to 4,025 devices Up to 5 devices Up to 325 devices with (1) CPU and (1) GB RAM