Air Conditioners, Distribution Cabinets And Engineering Cabins Air .

Transcription

8Air Conditioners, Distribution Cabinets and Engineering CabinsCatalogue number logicBK C -/Rated voltageNominal cooling capacity percentageWindow typeExplosion-proof air conditionerGeneral IntroductionFor explosion-proof window air conditioner, the correspondingproduct is the single cooling air conditioner in T1 and T3group. It is mainly used in h igh temperature areas, such asMiddle East, Middle Africa, South Asia and tropical zone nearbythe equator.Explosion-proof window air conditioner is developed on base ofprodu ct of Carrier, O GENERAL (FUJI) or GREE brand, by conducting explosion-proof treatment to internal control units,compressor, indoor and outdoor fan motors, temperature sensor system, protective system, heat-removal system, coolingsystem, etc., after which the outline dimensions and installation are the same as the original ones.Normally, the product is of T1 temperature class rated voltage is AC220V/50Hz. other voltages are available, such as AC220V/60Hz,AC230V/50Hz, AC230V/60Hz, AC240V/50Hz, AC240V/60Hz etc. please specify when ordering.Technical dataExplosion-proof window air conditionersExplosion protectionBKC- /II 3 G Ex d nC IIB T4 GcCertificatesLCIE 11 ATEX 1002X; IECEx CQM 11.0021XConformity to standardsEN 60079-0:2009, EN 60079-1:2007, EN 60079-15:2005IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-15:2010Dimension drawings (all dimensions in mm) - subject to alterationBHD51Zone 28/4General Catalogue 01.01.2012http:// www.waromgroup.com

8Air ConditionersBKC Series Explosion-proof Window Air ConditionersTechnical 50220/502P3P2750377012.817.4WCooling capacityBTURated voltage/Frequency (V/Hz)Input power (P)Cooling input power (W)Rated current (A)Application areas (m2)22323040Indoor unit5357Outdoor unit6063Sound level (dB)Outline dimensions (L x W x H) (mm)73068045073068050Weight (kg)45055Note Technical data above for products of T1 rating.AccessoriesImageNameApplicationOrdering codeT1, AC220V/50Hz801001T3, AC220V/50Hz801002T1, AC220V/50Hz801003T3, AC220V/50Hz801004T1, AC220V/50Hz801005T3, AC220V/50Hz801006T1, AC220V/50Hz801007T3, AC220V/50Hz801008BKC-50/220Explosion-proof fan motorBKC-70/220Explosion-proof fan motorExplosion-proof fan motorBKC-50/220Explosion-proof compressorBKC-70/220Explosion-proof compressorExplosion-proof compressorGeneral Catalogue 01.01.2012http:// www.waromgroup.com8/5

8Air Conditioners, Distribution Cabinets and Engineering CabinsCatalogue number logicBK F R/Rated voltageNominal cooling capacity percentageHeating and cooling type(cooling type without R)Wall typeExplosion-proof air conditionerGeneral IntroductionFor explosion-proof wall air conditioner, both single coolingand combined heating and cooling products in T1, T2,andT3 are available, to meet different requirements of low, med iumand high temperature zones world wide.Explosiooon-proof wall air conditioner is developed on baseof normal product of MITSUBISHI, Carrier, O GENERAL (FUJI)or GREE br ands, by taking explosion-proof measures to indoorand outdoor units. Measures to ou tdoor unit: by taking specialtechnics and control, conduct explosion-proof treatment tointernal control units, compressor, outdoor fan motor,protective system, heat-removal system, cooling system, etc. Besides, explos ion-proof control box and s ensor sys tem are c opedwith intrinsic safety. The outline dimensions and installation are the same as the original ones after explosion-proof treatment.Indoor unit: by taking special technics and control, dismantle internal electric control units and redesign to explosion-proof structurewhi ch enable s seperat e explosi on-proof control box. Remote controller (3V safet y power) and sensor system are coped with intrinsicsafety. The outline dimensions and installation are the same as the original ones after explosion-proof treatment.Normally, the product is of T1 temperature class rated voltage is AC220V/50Hz. other voltages are available, such as AC220V/6 0Hz, AC 230V/ 50Hz, AC230V /60Hz , AC240V/50Hz, AC240V/60Hz etc. please specify when ordering.Technical dataExplosion-proof wall air conditionersExplosionOutdoor unit BYS CompressorprotectionIndoor unitII 3 G Ex nC II 146 (T3)Whole unit: Ex nCd[ib] ib IIB 146Ex deib[ib Gb]nC IIB T4 GcEx deib[ib Gb]nC IIC T4 GcBZC Control stationII 3 G Ex d IIBOutdoor unit: Ex dnC IIB 146BDJ-W Fan motorII 3 G Ex d IIBIndoor unit: Ex d[ib] ib IIB T4BDJ-N Fan motorII 2 G Ex d IIB T4BXK Control stationII 2 G Ex d[ib] ib IIB T4LCIE 08 ATEX 6031XCertificatesConformity tostandardsBKF(R)- /IECEx CQM 08.0017XPCEC(China)EN 60079-0:2004, EN 60079-1:2004, EN 60079-11:2007, EN 60079-15:2005IEC 60079-0:2004, IEC 60079-1:2003, IEC 60079-7:2006, IEC 60079-11:2006, IEC 60079-15:2005Dimension drawings (all dimensions in mm) - subject to alterationIndoor unitControl boxOutdoor unitCableCableOutdoorBrass pipeIndoorZones 1&28/6General Catalogue 01.01.2012http:// www.waromgroup.com

8Air ConditionersBKF Series Explosion-proof Wall Air ConditionersTechnical dataTypeWCooling 2205550555074007400180001800024000240006200Heating capacity (W)Rated voltage/Frequency /9.82650/12.22650/12.4Input power (P)Cooling input power/Current (W/A)1790/8.48Heating input power/Current (W/A)224Application areas (m )Sound level (dB)Weight (kg)Note22362770/13.02729482734Indoor unit43434444Outdoor unit49515354Indoor unit1100 x 358 x 2941100 x 358 x 2941100 x 358 x 2941100 x 358 x 294Outdoor unit860 x 655 x 330860 x 655 x 330860 x 655 x 330860 x 655 x 330Control box420 x 350 x 178420 x 350 x 178420 x 350 x 178420 x 350 x 178Indoor unit16161616Outdoor unit54587878Control box10101010Outline dimensions(L x W x H) (mm)8400Technical data above for products of T1 proof indoor fan motorBKF(R)-71/220Explosion-proof indoor fan motorExplosion-proof indoor fan motorBKF(R)-50/220Explosion-proof compressorBKF(R)-71/220Explosion-proof compressorExplosion-proof compressorBKF(R)-50/220Explosion-proof outdoor fan motorBKF(R)-71/220Explosion-proof outdoor fan motorExplosion-proof outdoor fan motorGeneral Catalogue 01.01.2012http:// www.waromgroup.comApplicationOrdering codeT1, AC220V/50Hz802001T2, AC220V/50Hz802002T3, AC220V/50Hz802003T1, AC220V/50Hz802004T2, AC220V/50Hz802005T3, AC220V/50Hz802006T1, AC220V/50Hz802007T2, AC220V/50Hz802008T3, AC220V/50Hz802009T1, AC220V/50Hz802010T2, AC220V/50Hz802011T3, AC220V/50Hz802012T1, AC220V/50Hz802013T2, AC220V/50Hz802014T3, AC220V/50Hz802015T1, AC220V/50Hz802016T2, AC220V/50Hz802017T3, AC220V/50Hz8020188/7

8Air Conditioners, Distribution Cabinets and Engineering CabinsCatalogue number logicBK G R/Rated voltageNominal cooling capacity percentageHeating and cooling type(cooling type without R)Tank typeExplosion-proof air conditionerGeneral IntroductionFor explosion-proof tank air conditioner, both single cooling and combined heating and cooling products in T1, T2,and T3 areavailable, to meet different requirements of low, medium and high temperature zones world wide.Explosion-proof tank air conditioner is developed on base of normal product of MITSUBISHI, Carrier, O GENERAL(FUJI) orGREE brands, by taking explosion- proof measures to indoor and outdoor units. Measures to outdoor unit: by taking specialtechnic s and c ontro l, co nduct explosion-proof treatment to internal control units, compressor, outdoor fan motor, protective system,heat-removal system, cooling s ystem, etc . Besides, explosion -proof con trol box and sensor system are coped with intrinsic safety.The o utline dim ensions an d installation are the same as the original ones after explosionproof treatment. Indoor unit: b y takingspecial technics and control, dismantle internal electric control units and re-design to explosion-proof structure which enablesseperate expl osion-proo f control box. Remote controller and sensor system are coped with intrinsic safety. The outline d imensionsand installation are the same as the original ones after explosion-proof treatm ent .Normally, the product is of T1 temperature class rated voltage is AC220V/50Hz. other voltages are available, such as AC220V/60Hz, AC230V/50Hz, AC230V/60Hz, AC240V/50Hz, AC240V/60Hz etc. please specify when ordering.Technical dataExplosion-proof tank air conditionersExplosion protectionBKG(R)- /II 3(2) G Ex deib[ib Gb]nC IIB T4 GcII 3(2) G Ex deib[ib Gb]nC IIC T4 GcCertificatesPCEC (China); LCIE 12 ATEX ; IECExConformity to standardsEN 60079-0:2009, EN 60079-1:2007, EN 60079-7:2007, EN 60079-11:2007EN 60079-15:2010IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-7:2006, IEC 60079-11:2006IEC 60079-15:2010Zones 1&28/8General Catalogue 01.01.2012http:// www.waromgroup.com

8Air ConditionersBKG Series Explosion-proof Tank Air ConditionersTechnical g capacityHeating capacity (W)7800Rated voltage/Frequency (V/Hz)Input power (P)Cooling input power/current /12.14380/7.84380/7.8Heating input power/current (W/A)2600/11.35000/8.927 3250 8050 804343525253535656Indoor unit1900 x 600 x 2801900 x 600 x 2801900 x 600 x 2801900 x 600 x 280Outdoor unit870 x 850 x 319870 x 850 x 3191258 x 970 x 3691258 x 970 x 369Control box380 x 250 x 165380 x 250 x 165380 x 250 x 165380 x 250 x 165Indoor unit48484848119727 32Indoor unitOutdoor unit2Application areas (m )Sound level (dB)Outline dimensions(L x W x H) (mm)Weight (kg)14500Outdoor unit7575119Control box667Note: Technical data above for products of T1 rating.Dimension drawings (all dimensions in mm) - subject to alterationIndoor unitOutdoor unitControl boxCableCableBrass pipeIndoorGeneral Catalogue 01.01.2012http:// www.waromgroup.comOutdoor8/9

8Air ConditionersBKG Series Explosion-proof Tank Air sion-proof indoor fan motorBKG(R)-120/380Explosion-proof indoor fan motorApplicationOrdering codeT1, AC220V/50Hz803001T2, AC220V/50Hz803002T3, AC220V/50Hz803003T1, AC220V/50Hz803004T2, AC220V/50Hz803005T3, AC220V/50Hz803006Explosion-proof indoor fan oof compressorBKG(R)-120/380Explosion-proof compressorExplosion-proof compressor8/10ApplicationOrdering codeT1, AC220V/50Hz803007T2, AC220V/50Hz803008T3, AC220V/50Hz803009T1, AC380V/50Hz803010T2, AC380V/50Hz803011T3, AC380V/50Hz803012General Catalogue 01.01.2012http:// www.waromgroup.com

8Air ConditionersBKG Series Explosion-proof Tank Air sion-proof outdoor fan motorBKG(R)-120/380Explosion-proof outdoor fan motorApplicationOrdering codeT1, AC220V/50Hz803013T2, AC220V/50Hz803014T3, AC220V/50Hz803015T1, AC380V/50Hz803016T2, AC380V/50Hz803017T3, AC380V/50Hz803018Explosion-proof outdoor fan motorGeneral Catalogue 01.01.2012http:// www.waromgroup.com8/11

For explosion-proof window air conditioner, the corresponding product is the single cooling air conditioner in T1 and T3 group. It is mainly used in high temperature areas, such as Middle East, Middle Africa, South Asia and tropical zone nearby the equator. Explosion-proof window air conditioner is developed on base of product of Carrier, O .