Commercial ThermostatsGet Control. Get Honeywell.Application Selection andCross-Reference GuideWebStat ControllerT7350T7351FCommercial VisionPRO 8000 CommercialPRO 7000MultiPRO 7000ZonePRO Fan CoilLine VoltPneumatic

The Innovative LeaderFor more than a century, Honeywell has been on theleading edge of product development for energy-efficientHVAC and building automation products. Contractors andbuilding owners count on Honeywell commercial thermostatsfor the latest technology, ease-of-use and energy savings.SupportCommercial Thermostats Hotline1-763-954-6464Web Sitecustomer.honeywell.comNew Product tor PRO Programwww.contractorpro.comTechnical and Sales Literaturecustomer.honeywell.comFor more information, please contact your local Honeywellauthorized distributor or Honeywell sales representative.2

WebStat ControllerWeb Accessible Thermostats Honeywell’s WebStat system is composed of theworld-class T7350H LonWorks communicatingthermostats combined with a single WebStatcontroller which enables your network of T7350Hthermostats to be configured and monitoredfrom any computer with internet access fromanywhere in the world.Features Configure/commission/monitor throughthe same easy-to-use Web-based interface Free job estimating and submittal tools that provideeverything from wiring diagrams to guide specs Data trending for use in troubleshooting Customizable floor plan layoutsOS NumberDescriptionApplicationW7350A1000WebStat Controller with LonWorks Loncard and Power SupplyWeb-Based Network ControllerT7350H1009T7350H1017T735H1009: 3 Heat/3 Cool or 2 Heat/4 CoolConventional or 3 Heat/2 Cool Heat PumpCommunicating CommercialProgrammable ThermostatT7350H1017: Two 4-20 mA Outputsfor Modulating ApplicationsWebStat Features and Benefits SummaryLow InstalledCostLow Operating& Service CostEase of UseEmbedded Software Integrated Graphic, Configand Commissioning Tool Wizard Programming Tool Device Self Discovery Field Wiring & Sensor Avg. Diagrams Thin Client Web Remote Monitoring Trending, Troubleshooting Floor Plan Locator Remote Programming Multi-User Access ViewUser Privilege SetupAdvanced DehumidificationAdvancedComfort Special Event, Holiday Scheduling (E)Override Controls (E)Thermostat Assignment (E)Advanced Remote SensingE Energy Savings 3

T7350HCommunicating Thermostat AWARECompatible With These Honeywell SystemsLCBSLonSpec /LonStation XL15B W7760B2001WEBsAX T7350 WizardWebStat W7350A1000OS NumberT7350H1009 Communication via LonWorks Network– Remote access for diagnostics Integrated humidity sensor– Several strategies for dehumidifying 365-Day Schedule– Schedule holidays throughout the yearto save energy Remote sensing– Indoor, outdoor, humidity, occupancy anddischarge air sensors available for added flexibility– Outdoor Air and Discharge Air Temperature Lockout Controls up to 3H/3C or 2H/4C conventionalsystems or 3H/2C heat pumps (T7350H1009)– Flexibility allows the same thermostat to beused on every RTU in the system Has two 4-20 modulating outputs for controllingheating and cooling valves (T7350H1017)– Allows thermostat to be used in hydronicheating or cooling applications– Control of staged and modulating hybrid systemsDescriptionApplicationT735H1009: 3 Heat/3 Cool or 2 Heat/4 CoolConventional or 3 Heat/2 Cool Heat PumpCommunicating CommercialProgrammable ThermostatT7350H1017: Two 4-20 mA Outputsfor Modulating 09All T7300swith 3,SZ1035,SZ1009T7350H1017No ush mount),C7770A1006(return airduct),C7041P2004(button sensor)

T7350MModulating and Staged Thermostat Integrated humidity sensor– Several strategies for dehumidifying 365-Day Schedule– Schedule holidays throughout the year tosave energy Remote sensing– Indoor, outdoor, humidity, occupancyand discharge air sensors available foradded flexibility– Outdoor Air and Discharge Air Temperature Lockout. Has two 4-20 modulating outputs for controllingheating and cooling valves– Allows thermostat to be used in hydronicheating or cooling applications Control of staged and modulating hybrid systems PID loop– First thermostat with configurable PID loop AWAREOS NumberT7350M1008DescriptionApplication– Two 4-20 mA Outputs for Modulating Applications– Two Relays for Staged Control– Advanced DehumidificationModulating CommercialProgrammable o feringNoEquivalentOfferingTBS/Basys (flush mount),C7770A1006(return airduct),C7041P2004(button sensor)5

T7350A, B, DStandalone Staged Thermostat Integrated humidity sensor (T7350D)– Several strategies for dehumidifying 365-Day Schedule– Schedule holidays throughout the yearto save energy Remote sensing (T7350B, D)– Indoor, outdoor, humidity, occupancy and dischargeair sensors available for added flexibility– Outdoor Air and Discharge Air Temperature Lockout Controls conventional or heat pump systems Flexibility allows the same thermostat to beused on every top roof unit in the system PID loop– First thermostat with configurable PID loop AWAREOS NumberDescriptionApplicationT7350A1004: 1 Heat/2 Cool and 2 Heat/1 CoolConventional, 2 Heat/1 Cool Heat PumpT7350A1004T7350B1002T7350B1002: 3 Heat/2 Cool and 2 Heat/3 CoolConventional, 3 Heat/2 Cool Heat PumpT7350 CommercialProgrammable Thermostat T7350D1008: 3 Heat/3 Cool and 2 Heat/4 CoolConventional, or 3 Heat/2 Cool Heat Pump with 2 Auxiliary Stages, Advanced Dehumidificationand Occupancy rsThermostatsT7350D1008All stats9700i, 9701i9700i Series,300 SeriesAll Invensys/RobertshawThermostatsTCS/basys ControlsT7350B1002All T7300swith Q7300Aand sT7350A1004All entional/Heat PumpReplacementsSZ1009All 1033,SZ1009All ),TR22,TR23,TR24,C7772A1012(flush mount),C7770A1006(return airduct),C7041P2004(button sensor)

T7351FStandalone Staged Thermostat Keypad programming– All configuration is done through the keypad Integrated humidity sensor– Several strategies for dehumidifying 365-Day Schedule– Schedule holidays throughout the yearto save energy Remote sensing– Indoor, outdoor, humidity, occupancy and dischargeair sensors available for added flexibility– Outdoor Air and Discharge Air Temperature Lockout Controls conventional or heat pump systems Flexibility allows the same thermostat to beused on every top roof unit in the system AWAREOS NumberDescriptionApplication3 Heat/3 Cool and 2 Heat/4 Cool Conventional, or3 Heat/2 Cool Heat Pump with 2 Auxiliary Stages,Advanced Dehumidification and Occupancy OptionT7351 CommercialProgrammable l/Heat PumpT7351F2010All statsAll Invensys/RobertshawThermostatsAll Carrier/TotalineThermostatsTCS/basys ),TR22,TR23,TR24,C7772A1012(flush mount),C7770A1006(return airduct),C7041P2004(button sensor)7

T7350/T7351F ApplicationsSchoolsRestaurant/Food Service Up to 10 holidays can be scheduled into the Holiday PID Commercial Algorithm provides the bestScheduler, which can be programmed to handle multiplecomfort control to react to the constantly changingdays per holiday event, can program closed daysfood service and restaurant environments, reactingduring the summer or spring break and can bequickly to changing load demands via fast-sensingprogrammed for specific calendar events. (All Models) Dehumidification features can be used to controltime constants. (All T7350 Models) Remote Sensing configuration options allow the use ofdew points in buildings and can be deployed wherecommercial 20K ohm and 10K ohm sensors to createmoisture is an issue, such as around school pools ora 20K ohm averaging network, a good solution for foodin humid locations. (T7350D, M, H and T7351F)service locations that have high load demands. Temporary Override can be configured from 1 to 8 hoursto allow override from unoccupied schedule to an(T7350B, D, M, H and T7351F) Economizer function allows restaurants to meetoccupied schedule as well as for classrooms that areventilation requirements and is also important toonly used for parts of the week or just occasionally used.balance the air intake of the restaurant. Restaurants that(All Models)are not properly balanced do not achieve good comfort PID Algorithm is the best control algorithm availablethat can heat and cool large spaces, such ascontrol as they draw in unconditioned air. (All Models)gymnasiums or auditoriums, quickly and accurately.Churches/Public WorshipThe PID Algorithm is specifically tuned for oversized PID Algorithm is the best control algorithm available thatequipment and has a short sensor time constant thatcan heat and cool large spaces, such as sanctuariescan react quickly to demand changes. (All T7350 Models)and fellowship rooms, quickly and accurately. The PIDBanks Easy-to-use Holiday Scheduler. (T7350B, D, M, Hand T7351F)Algorithm is specifically tuned for oversized equipmentand has a short sensor time constant that can reactquickly to demand changes. (All T7350 Models) T7350 Wall Modules, including the T7771, TR22, TR23 T7350 Palm Software comes pre-configured withand TR24 models allow for setpoint-only adjustment withall bank holidays for easy programming into therange stops, temporary override control or a combinationthermostat. (All T7350 Models)of both to provide the end-users with flexibility to provideHealthcare and Gym Facilities Solid solution for rooftop units on facilities that demandoptimal comfort during occupied events. (T7350B, D, M, Hand T7351F)very accurate temperature and enthalpy control.RetailThe PID Algorithm will maintain the most accurate Customizable Recovery Ramp feature guaranteestemperature control in the facility. (All T7350 Models) Dehumidification features are ideal for controllinghigh-moisture areas. (T7350D, M, H and T7351F)the exact temperature specified when the store opens,ensuring customer and staff comfort. (All Models) Easy-to-use Holiday Scheduler. (All Models) For energy management, the T7350 Demand LimitBump and Demand Limit Control can be programmed withcommunicating versions of the T7350 to provide energysavings when rooftop units can be staggered to controlenergy costs during peak periods. (T7350H)8

Office Building Zones The T7350 is one of the only Honeywell thermostats thatintegrate with occupancy sensors for office zonesModulating Control –Hydronic Boilers and Pumps Combine modulating control and on/off relay control.that are normally unoccupied or partially occupied.The modulating output can control modulating actuator(T7350D, M, H and T7351F)valves during the heating season and up to 2-stage T7350 Wall Modules, including the T7771, TR22, TR23and TR24 models allow for setpoint-only adjustment withconventional cooling during the cooling season. (T7350M, H) Ideal for split systems that have separate heating andrange stops, temporary override control or a combinationcooling equipment and need both a modulating outputof both to provide the end-users with flexibility to provideand a conventional output. The fan relay can be config-optimal comfort during occupied events. (T7350B, D,ured for either conventional (plenum switch controls fan)M, H and T7351F)or electric (thermostat energized fan on call for heat) Customizable Recovery Ramp feature guarantees theexact temperature specified when the office opens.(All Models)applications. (T7350M, H) Various hydronic control applications are possible,including unit ventilators, fan coils or any other modulating system. The modulating outputs support both directHeat Pumpsand reverse acting signals. (T7350M, H) Outdoor Air Sensor automatically turns off heat pumpequipment in cold climates. The T7350 is the onlyCommunicating ControlHoneywell thermostat that uses both an outdoor air Using the Honeywell Command Display S7760A, thesensor and indoor sensors/wall modules for heat pumpHoneywell LonStation front-end or the Honeywell XL15Bcontrol applications. (T7350B, D, H and T7351F)Web Building Manager, a single user interface can beEquipment Protection Discharge Air Sensor detects abnormally high or low dis-accessed to perform the following functions: (T7350H)– Group Scheduling– Group Override/Setbackcharge air temperatures and shuts down equipment– Trending (not supported with command display)if limits are exceeded. (T7350B, D, M, H and T7351F)– Alarming (not supported with command display)Modulating Control —Discharge Air Control By tuning the PID loop, optimal control can be achieved.20K ohm duct sensors can be used in the wall module ter-– Demand Limit Control (XL15B only)– LonSpec Configuration PC Tool– Web-Based Control (XL15B only)– Dial-Up Control (LonStation only)minals for temperature sensing. The modulating output willWeb-Based Interfacecontrol the damper position. (T7350M, H) Using Honeywell’s WebStat Controller in conjunctionwith the T7350H communicating thermostats allows forOS NumberBenefita single user interface to be used during system setup,commissioning, monitoring and troubleshooting. With theT7350A1004Energy Savings, Comfort, Fresh AirWebStat Controller, the following functions are enabled:T7350B1002Energy Savings, Comfort, Fresh Air– Group SchedulingT7350D1008Energy Savings, Comfort, Fresh Air,Dehumidification– Group Override-SetbackT7351F2010Energy Savings, Comfort, Fresh Air,Dehumidification– AlarmingT7350M1008Energy Savings, Comfort, Fresh Air,Dehumidification, ModulatingT7350H1009Energy Savings, Comfort, Fresh Air,Dehumidification, CommunicatingT7350H1017Energy Savings, Comfort, Fresh Air,Dehumidification, Modulating, Communicating– Trending– Custom Graphicsand Floorplans9

CommercialVisionPRO 8000Programmable Touchscreen Thermostat Touchscreen user interface– The sleek design, menu-driven programmingand large touchscreen display are all here Saves energy– Effortless programming helps your customerssave up to 33% off their energy bill1 Meets commercial building codes– Pre-occupancy Purge, Economizer Output andOverride Limits meet all fresh air and overridelimitation requirements– Qualifies for utility rebates2– Title 24/IECC/ASHRAE codes Multiple lockout levels– Save energy and money by preventingunauthorized setting changes Compatible with auxiliary commercial devices– Commercial sensors– Economizers Commercial comfort– Commercial Algorithm, configurable recovery rampsand temporary override button allow users to controlat setpoint and guarantee a comfortable environment AWAREOS NumberTB8220U10031If used as directed. Savings may vary depending on geographicregion and usage.2Where applicable.DescriptionApplicationCommercial VisionPRO 8000Programmable Thermostat– 2 Heat/2 Cool Conventional– 3 Heat/2 Cool Heat PumpSensorCompatibilityCommercialVisionPRO 800010TB8220U1003T7300 ubbaseIF90 Series,IF80 Series9800 Series,9700i Series,300 CSSN2-WCTR21,TR21-A(averaging),C7772A1012(flush mount),C7770A1006(return airduct),C7041P2004(button sensor)

CommercialPRO 7000Thermostat Large, easy-to-read display– Screen size is more than double competitivethermostats in this class, allowing for moreinformation to be displayed on the easy-to-viewbacklit display Saves energy– Easy-to-use, menu-driven programming helpsyour customers save up to 33% off energy bills1 Meets commercial building codes– Pre-occupancy Purge, Economizer Output, andOverride Limits meet all fresh air and overridelimitation requirements– Qualifies for utility rebates2– Title 24/IECC/ASHRAE code Multiple lockout levels– Save energy and money by preventingunauthorized setting changes Compatible with auxiliary commercial devices– Commercial sensors– Economizers Commercial comfort– Commercial Algorithm, configurable recovery rampsand temporary override button allow users to controlat setpoint and guarantee a comfortable environment AWAREOS NumberTB7220U10121If used as directed. Savings may vary depending on geographicregion and usage.2Where applicable.DescriptionApplicationCommercialPRO 7000Programmable Thermostat– 2 Heat/2 Cool Conventional– 3 Heat/2 Cool Heat PumpSensorCompatibilityCommercialPRO 7000TB7220U1012T7300 F90 Series,IF80 Series9800 Series,9700i Series,300 CSSN2-WCTR21,TR21-A(averaging),C7772A1012(flush mount),C7770A1006(return airduct),C7041P2004(button sensor)11

MultiPRO 7000Multispeed and Multipurpose Thermostat Large, easy-to-read display– Screen size is more than double competitivethermostats in this class, allowing for more informationto be displayed on the easy-to-view backlit display. Programmable or non-programmable modes Saves energy– Effortless programming helps your customerssave up to 33% off their energy bill1– Remote setback input for occupancy sensorsor timeclocks– VersaSpeed fan ramping algorithm and auto fanreset algorithm (fan coil and PTAC applications) Multiple lockout levels– Save energy and money by preventingunauthorized setting changes Compatible with commercial sensors Commercial comfort– Commercial Algorithm, configurable recovery rampsand temporary override button allow users to controlat setpoint and guarantee a comfortable environment Multispeed and Multipurpose– 1 Heat/1 Cool Conventional (single speed)– 2 Heat/1 Cool Heat Pump (single speed)– 2 Heat/1 Cool PTAC (2 speeds)– 2 or 4-pipe Fan Coil (3 speeds) AWARE1OS NumberIf used as directed. Savings may vary depending on geographicregion and usage.DescriptionApplication1222MultiPRO Multispeed andMultipurpose ThermostatTB7100A1000Heat/1 Cool Conventional,Heat/1 Cool Heat Pump,Heat/1 Cool PTAC Systems andor 4-pipe Fan -0300PSG oneywellMultiPRO TDMS24-AH22CBTR21,TR21-AC7772A1012(flush mount),C7770A1006(return airduct),C7041P2004(button sensor)

Private Label ProgramAssociate Your Company NameWith The Honeywell Brand Give your customers the quality and reliability of aHoneywell thermostat Let customers know who to call for future HVAC needs Up to three full lines of personalization — imprinteddirectly on the thermostat cover Low minimum order quantities — starting at just 48 units No annual volume commitmentsAcme Heat & Cool1-800-222-2222Acme@heatcool.com Fastest turn-time in the industry — imprint approval in 5days or less, all orders shipped in 10 days or less** Provided all program conditions are met.Based on product availability.Program DetailsMIN. ORDER QUANTITYORDER PROCESS*IMPRINT FEEInitial Orders48 UnitsThrough Web site customer.honeywell.comNoneRe-Orders24 UnitsThrough Web site customer.honeywell.comNoneDistributor InstructionsBefore you begin creating aprivate label, set up a uniqueproduct part number(s) for yourcustomer in your system. The part number(s) that youassign must be unique to eachcustomer and each product. Maximum of 18 characters perdistributor part number. Partnumbers must be upper casewith no spaces. (For example:TB8220CLIMATRON). Do not use Honeywell partnumber(s) for your customerpart numbers. We suggestusing a variation such as theexample above. You must use your distributorpart number when orderingprivate label units.Web SetupFree setup on all orders placed through customer.honeywell.comLog on to customer.honeywell.com using your Distributor Account Number and password* andclick on the “Private label Program” link in the right-hand column of the screen. Click on the“Create New Label” link on the secondary menu bar at the top of the screen.Step 1: Create a Label Select the font type. Type in your customer’s information exactly as they would like it to appear on their thermostats. Preview and submit your label when complete.Step 2: Part Number Setup Select the Honeywell thermostat part numbers from the drop-down menu (the description willautomatically populate). Enter in your customer’s unique part number(s). Submit for approval and print a copy for your records. You will receive approval from Honeywell within 5 days of submittal that part number(s) have beenset up and product is available to order.Step 3: Place Your Order Place an order (using your customer’s unique part number) after receiving both e-mail confirmationsfrom Honeywell that your label and part number(s) have been approved.*Contact Honeywell customer care with any questions relating to logging on to customer.honeywell.com.ALL PRIVATE LABEL ORDERS REQUIRE A MINIMUM INITIAL ORDER QUANTITY OF 48 UNITS. Mix/match is allowed to reach 48 minimuminitial order quantity, but must contain a minimum of 24 units per part number. Mix and match products include Commercial VisionPRO , VisionPRO ,CommercialPRO , FocusPRO and PRO model families. Please refer to customer.honeywell.com for full OS numbers. Orders must be placed incase quantities of 12. Re-order quantity is 24 units (must be the same part number). Private label orders are non-cancelable.All private label orders will require a 10-day lead time — from the time submitted label artwork is approved and a purchase order is received from the Wholesaler/Distributor to the time theprivate label product is hipped by Honeywell. All private labeled orders will be shipped directly to the Wholesaler/Distributor. Honeywell will not hold any inventory on private labeled product.Any change in the label will be treated as a new label creation and the approval process must be followed in total. Coordination will be required for the transition, including purchasing existingstock of customer parts. All private label requests must conform to the standards set by Honeywell. Honeywell reserves the right to deny any private label request as its own discretion.Any inventory in the channel (in the factory in the warehouse or in transit) is the responsibility of the Wholesaler/Distributor. Honeywell will not be liable for any inventory in the channel.By ordering private labeled products, you are agreeing to the terms stated in this program description. Honeywell reserves the right to change or cancel this program without notice.13

Commercial VisionPRO 8000, Commercial PRO 7000 And MultiAfter-Hours Control in Office BuildingsCondominiums/Hotels The Override button can be configured for a length of Honeywell’s MultiPRO thermostat uses the patenttime (1, 2, 3, 4 hours) and can be configured for an exactpending VersaSpeed fan ramping algorithm to giveoverride setpoint through the use of the lockout levelmultiunit facilities such as hotels, condos, dorms andset-up and the temperature range stop setup. A user mayretirement facilities more control and additional savingsoverride to an exact setpoint or be given a setpoint rangeto choose from. Provides comfort during after-hours occupancy whilemaintaining energy savings after the tenant leavesthrough the elimination of unnecessary energy use. The fan coil and PTAC applications on the MultiPRO make it a perfect thermostat for hotels or condominiums.(See our SuitePRO thermostat, too)the building.Schools – Individual Zone Control Cancel Period button allows thermostat to remain inpermanent unoccupied mode to provide energy savingsfor school classrooms not being used. Teachers wanting to use a classroom press the OverrideEconomizer Integration Compatible with Honeywell Economizer controllers, whichgenerate free cooling if appropriate outside air and/orhumidity conditions exist. (Not available on MultiPRO ) Thermostats are integrated with economizers to maintainminimum ventilation requirements of the buildingbutton and the thermostat enters the occupied periodduring occupied periods. During unoccupied periods,providing the necessary comfort.thermostats can override the economizer to fully close the The Override button can be configured for a length oftime (1, 2, 3, 4 hours) and can be configured for an exactdamper, thereby eliminating air infiltration into the buildingto maximize energy savings.override setpoint through the use of the lockout levelsetup and the temperature range stop setup. A user mayoverride to an exact setpoint or be given a setpoint rangeto choose from. During long holidays or during summer vacation, thethermostat can be programmed with the Holiday button toprovide the greatest amount of energy savings.Restaurant/Food Service Control Honeywell’s Commercial Algorithm provides the bestcomfort control to react to the challenging environmentsof food service and restaurant environments. Thecommercial algorithm is tuned to provide the tightestcomfort control and react quickly to changing loaddemands via fast-sensing time constants. Economizer function allows restaurants to meet theappropriate ventilation requirements and is also importantto balance the air intake of the restaurant. Restaurantsthat are not properly balanced do not achieve goodcomfort control as they draw in unconditioned air. Remote sensing configuration options allow the use ofcommercial 10K ohm and 20K ohm sensors to provideany remote sensing combination (1 to 9 sensors) tocreate an averaging network.14OS NumberBenefitTB8220U1003Energy Savings, Comfort, Fresh AirTB7220U1012Energy Savings, Comfort, Fresh AirTB7100A1000Energy Savings, Comfort and Versatility

iPRO ApplicationsRemote SensingUnit VentCan be configured using Honeywell’s line of 10K ohm and Can be programmed to control ASHRAE Cycle 1 unit vent20K ohm commercial sensors, supporting the followingapplications that residential thermostats don’t: Temperature Averaging Networksapplications. Unit vent outside-air damper can be programmed throughthe Economizer feature. When the unit vent is on andBecause commercial thermostats can be configuredoccupied, the thermostat will enable the economizerto a 20K ohm network, temperature average networksrelay to keep the outside air damper at the maximumof anywhere from 1 to 9 sensors can be deployed.percentage opening. Only maximum percentageCombinations of 10K ohm and 20K ohm sensors areopening is available; the thermostat will not modulateuse to create the averaging network. The most popularthe damper. When the unit vent is unoccupied, thesensors are the TR21 and TR21-A (averaging) 10K sensorthermostat will close the damper.and the TR21 and TR21-A 20K sensor. Range Stop feature can be configured to program a lowlimit setpoint to prevent equipment damage from freezing.SubbaSeTR21Commercial Codes Comply with commercial building codes and meet the mostrigorous standard, California’s Title 24.TR21-ATR21 No hold button is available, so the thermostat remainsin permanent schedule. Override button allows the tenant to override anunoccupied mode for up to 4 hours and can be configuredfor an exact override setpoint. Depending on the partiallockout level deployed, a user may override to an exactsetpoint or be given a setpoint range to choose from.THE TR21-A IS A 10K OHM SENSOR Pre-Occupancy Purge and Economizer functions allowthe building owner to meet all HVAC ventilation codes for Room Temperature Controlcommercial buildings.Performed via a sensing network using the followingsensors:– Wall Sensors: TR21-A (10K) for averaging only,TR21 (20K), C7189U1005 (10K)Lighting Load Reduction (TOD) Commercial buildings are frequently automated to turn off– Flush Mount Sensors: C7772A1012 (20K)lighting loads. Lighting loads can use even more energy– Button Sensors: C7041P (20K)than HVAC systems in commercial buildings, and 79% Duct Return Temperature Controlof commercial buildings have off-hours lighting loadPerformed using the following 20K sensors:reduction control. By using the time-of-day relay (TOD)C7041B/C7041C/C7770A/C7041Jin conjunction with a lighting control system, users canautomate their lighting loads. (Not available on MultiPRO )15

AccessoriesTStatSpec & USB TIMOS #: USB-TIM TStatSpec is a free download fromcustomer.honeywell.com Use to configure, download, calibrate and Users can capitalize on more T7350 featuresthat are configurable at the thermostatkeypad, including:– 365-day holiday programmingmonitor theT7350 thermostats with one– Configurable ramp ratessoftware tool– Configurable PID loop tuning Easily configure and change schedules basedon the list of holidays Work with a interface that is a standardMicrosoft Windows look and feel Back up and restore thermostat conf

Loncard and Power Supply Web-Based Network Controller T7350H1009 Communicating Commercial Programmable Thermostat T735H1009: 3 Heat/3 Cool or 2 Heat/4 Cool Conventional or 3 Heat/2 Cool Heat Pump T7350H1017: Two 4-20 mA Outputs T7350H1017 for Modulating Applications webStat Features and benefits Summary Low Installed Cost Low Operating .