Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:38 PM Page 1Improving Data Center Efficiency

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:39 PM Page 2

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:39 PM Page 3Controlling Bypass Airflow in your Data CenterBypass airflow can have a significant impact on the coolingPartnering to Provide Tate KOLDLOKcapacity and efficiency of any data center. One key part of bestTate has partnered with Upsite Technologies the makers ofpractice design for raised floor data centers includes theKOLDLOK to bring you the most advanced wire & cableelimination of bypass air. Bypass air is any air delivered into thepenetration air sealing grommet available. This partnership wasdata center that is not consumed by the equipment andforged from the common understanding that the raised floorexhausted as waste heat. Common practices to reduce bypassdesign is the most cost-effective and flexible way to future proofair include the use of containment systems, blanking panels,a data center. With raised floors a data center can handle largeangular or directional air delivery, and air sealing grommets for allvolumes of wires, cables and other services, while efficientlywire and cable penetrations in the floor.cooling the heat loads of modern and next generation designs.Advantages of a Raised Floor Easily adapt to technological and client changes over the datacenter’s life-cycle at low cost. Reduced operating costs and lower facility and maintenancecosts through accessible, flexible, and adaptable services. Offers the best overall solution for distributing water and otherliquid cooling agents to row and rack based equipment. Underfloor service distribution space keeps the interior spaceclean and neat for proper air migration in-and-out of equipment. Water distribution lines placed under a raised floor pose lessthreat in the event of water leaks or condensation due tosystem failure. Raised floors provide the platform for future scalability. Ability to accommodate a range of cooling solutions whileincreasing efficiency and heat load capacities. Provides the ability to separate water, power and cable. Flexibility to incorporate the most energy efficient designopportunities for cooling data centers. Ability to terminate cables wherever you need them withcomplete flexibility, accessibility, and unlimited capacity.3

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:39 PM Page 4Benefits of Including Tate KOLDLOK in DesignStandardization Ensures Quality and Saves TimeSaves Time & Eliminates the MessImprove Efficiency, Capacity & PerformanceTate has identified a standard cut-out location that works withUsing Tate KOLDLOK air sealing grommets will help improve dataany rack to ensure that the cutout is always in the propercenter efficiency, capacity and cooling performance. With thelocation inside the back door. The location is 4” from the edge ofability to use a factory cut in a standard location to supply wiresthe panel and centered. When specified as a factory cut-out,and cables to any size rack provides the opportunity to specifyboth the time and mess associated with field cutting is eliminated.the use of this seal during the design phase. By specifying theEasy to Install & Relocateuse of these seals the architect and owner can have theconfidence that they are using the best performing grommet inWith the Tate KOLDLOK installing cutouts during the initial build isthe industry and not a poor performing imitation. Existingeasy and cost effective. Tate KOLDLOK air sealing grommets arefacilities and data center expansions will likewise benefit form theavailable with domed lids that keep equipment from being rolledsuperior sealing ability of the Tate KOLDLOK.over them. These lids allow the raised floor installers to place thecut-out in the floor as they build-out the facility. The Tate KOLDLOKgrommet’s can be precisely position in relationship to the airflow5"panels or placed in a special holding area of the floor to later be9.26.7moved into the final position as equipment is deployed.5"7.375Furthermore since this location works with any size rack the cut-4""outs can be stored in reserves at your facility for futuremoves/adds/changes.24"x48" Rack.28"x36" Rack11x8.75.24"x40" Rack.32"x48" Rack11x8.7511x8.75.11x8.75.24"x48" Rack11x8.75.The figures above shows examples of some common racks currently available on the market. The blue box representsthe location of the cut-out seal in the back of the rack when using Tate’s standard location. This standard location willalso work with virtually any rack dimension or position.4

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:39 PM Page 5Tate KOLDLOKImproved Air Sealing PerformanceThe Tate KOLDLOK air sealing grommet is designed to prevent airleakage from the underfloor plenum where penetrations in araised floor are needed to deliver power, data and other servicesto equipment above the floor. Tate KOLDLOK is a 8.75”x11”injection molded ABS plastic grommet designed to mount in araised floor panel. Supplied with an optional rigid lid capable of2:00AMsupporting up to 250lbs this grommet is designed to be installedat the same time as the raised floor. The interior crenellateddesign provides a superior seal over other brush style grommetsimproving air sealing performance and saving energy.Tate KOLDLOK CFM Leakage Comparison at .05" Static PressureOpen Area AvailableNo PenetrantsBrush Style A14.3 sq.in.0.433.72.373.98Tate KOLDLOK35 sq.in.0.072.170.3851.16No PenetrantsBundle of 32 Cables 1x9/16" Power Cables 4x9/16” Power CablesBundle of 32 Network Cables1x9/16" Power Cables4x9/16” Power CablesThe example below provides an example of the energy associated with sealing cutouts in a 10,000 sqft data center. Inaddition, you will see a comparison using a typical brush style grommet vs. Tate KOLDLOK. The Tate grommet can savenearly 800 in annual energy usage. Visit our website to download an electronic version of this model to enterinformation specific to your data center.Energy Model - Cutout Sealing 4x9/16" Power CablesNo Cutout SealData Center SizeBrush Style A Cutout SealTate KoldLok10,000 Square Feet10,000 Square Feet10,000 Square FeetNumber of IT Racks500500500Number of Cable Cutouts500500500CFM Leakage Per 0.41098854111573252 0.10 0.10 0.10 109,885.44 1,115.67 325.17Total CFM LeakagekW/kCFM Fan EnergyPower Wasted (kW)Energy Wasted Annually (kWhr)Cost per kWhrAnnual Energy Cost5

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:39 PM Page 6Full Line of KOLDLOK Air Sealing GrommetsStandardization Ensures Quality and Saves TimeTate is also the exclusive provider of all KOLDLOK grommets inthe raised flooring industry. We offer both surface mount andflush mount designs in various sizes to meet the specific sealingneeds of any data center. The Grommets satisfy NFPA 75Section 5-4.4 requirement by self-dressing the raw metal edgesof raised-floor tile cable cutouts. They are also compliant with thedirective that restricts the use of certain hazardous substances inIntegralelectrical and electronic equipment (RoHS).IntegralThe Split Integral Grommets allow tiles to be moved withoutcapturing cables. This grommet is designed to seal cableopenings in new raised-floor systems prior to the installation ofcommunication or power cabling. The large 32 square inchusable cabling area accommodates a variety of cablingrequirements, including 100 amp power connectors.Integral GrommetsUS unit of measure (Inches)Metric (mm)8x4203 x 102To install Grommet in interior of the tile9 1/4 x 6 3/4235 x 172To install long side of the Grommet on the tile edge9 1/4 x 7 1/2235 x 191To install short side of the Grommet on the tile edge10 1/8 x 6 3/4235 x 172Usable Cable AreaMiniMiniDesigned to seal small cable openings in the raised floor of newor existing computer rooms. The 5” x 2.5” opening offersflexibility for data centers that have multiple cable opening sizes.This grommet offers a cost-effective method of separating datacabling from power cabling.Mini GrommetsUS unit of measure (Inches)Metric (mm)5 x 2 1/2127 x 64To install Grommet in interior of the tile4x6102 x 152To install long side of the Grommet on the tile edge5x6127 x 152To install short side of the Grommet on the tile edge4x7102 x 179Usable Cable Area6

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:39 PM Page 7RoundThe Split feature of the KOLDLOK Round 4" allows productinstallation or removal without disturbing cables. Designed to sealopenings in new and existing raised floor cutouts to block bypass4” Roundairflow and maximize cooling system efficiency.Integral GrommetsUS unit of measure (Inches)Metric (mm)41029.6 sq.in.619 sq.mm.Usable Cable AreaMaximum cutout size sealedSurface MountSurface MountDesigned to seal a variety of existing raised-floor tile cutouts andallow the flexibility of removing tiles without capturing cables.Available in three different length and width dimensions to allowfor larger sealing capacities. The Grommets integrate with theraised-floor static dissipation system, providing 1 GigaOhm ofresistance.Mini GrommetsUS unit of measure (Inches)Metric (mm)Usable Cable Area10 x 7254 x 184Maximum cutout size sealed8x4210 x 102ExtendedDesigned to seal a variety of existing larger openings, with theadded flexibility of modification for unique openings. TheGrommets can be modified to seal unique cable openings andExtendedother open areas such as gaps around CRAC & CRAH units.Mini GrommetsUS unit of measure (Inches)Metric (mm)22 x 2 1/2127 x 6424 x 4102 x 152Usable Cable AreaMaximum cutout size sealed Item7

Tate Koldlok 8pp 2012:Air Sealing Grommets 2/15/12 5:40 PM Page 8Additional Data Center ProductsVisit www.tateinc.com for more informationSmartAireDirectAireVAV damper to automatically control airflow68% open area all steel panel that anglesat the rack level improving energy efficiency.airflow to achieve a 93% TAC rate.PowerAireMulti-zone Opposed Blade DamperFan assisted airflow at the rack level for3 zone damper for balancing airflow to individualhandling extremely high & diverse heat loads.14U sections of a rack to save energy.Tate Access Floors, Inc.International Sales & Support Office:169 Jalan Jurong Kechil#7-011, SherwoodSingapore 598669Tel: 65-6468-1332 Fax: 65-6468-6681Corporate Headquarters:7510 Montevideo Road, Jessup, MD 20794Tate Hotline: 1-800-231-7788Tel: 410-799-4200 Fax: 410-799-4207Production Facilities:7510 Montevideo Road, Jessup, MD 2079452 Springvale Road, Red Lion, PA .comTate Access Floors, Inc.components are proudlymade in the U.S.A.Tate ASP Access Floors, Inc.Canadian Office & Production Facilities:880 Equestrian Court, Oakville, ON L6L 6L7 CanadaTate Hotline: 1-800-231-7788Tel: 905 847-0138 Fax: 905 847-0141tateasp.comkingspan.comA member of Tate , ConCore , GrateAire , PosiLock , PosiTile , Floating Floors , Integral Trim , SustainAbility , AirArrest , DirectAire , SmartAire and PowerAire , are registered trademarks of Tate Access Floors, Inc.Inc. Revised 2012ContainAireTM, RackAireTM, Air»ConnectTM and EcoCoreTM are Trademarks of Tate Access Floors Inc. 2011 Tate Access Floors,

28"x36" Rack 24"x40" Rack 32"x48" Rack 24"x48" Rack Improve Efficiency, Capacity & Performance Using Tate KOLDLOK air sealing grommets will help improve data center efficiency, capacity and cooling performance. With the ability to use a factory cut in a standard location to supply wires and cables to any size rack provides the opportunity to .