Neptune SafeAir Smoke Evacuation

Transcription

Neptune SafeAirSmoke evacuationThe complete solution forevacuating surgical smokefrom your operating theatre

SafeAirSmoke EvacutationPencilsAs part of the operating theatre team, you provide lifesaving andlife changing care every day. And you do it in an environmentwith inherent risks such as surgical smoke. Surgical smoke is agenuine health concern spurring clinical, quality and safety groupsaround the world to take action – including us. With simple devicesolutions, education and financing options we’re here to help youcreate a safer, smoke-free operating theatre.2-in-1 monopolar pencilsperform smoke evacuation,electrosurgical cutting andcoagulationCapture surgical smokeat the sourceFEOn-tip suction:surgical smoke is captureddirectly from the sourceCaptures smoke – and thepotential hazards it carries– directly at the sourcereducing exposureErgonomic design aidstransition from standardelectrosurgical pencilsData shows that surgical smoke particles can travel 40 mph andmultiply to more than 35 million particles/cubic metre in fiveminutes1, 2. That’s why professional organisations advocate “ontip” smoke evacuation directly at the surgical site.3, 4, 5 To achievethis, we offer two SafeAir Smoke Evacuation Pencils; standardand telescoping enabling use on open surfaces and inside cavities.Push button:tactile feel push buttonsfor ease of operationRocker switch:rocker switch providesergonomics activationPencil weighs just 21.7g tohelp preserve the surgeon'snatural touch and feelCompatible with the NeptuneWaste Management Systemand the SafeAir CompactSmoke Evacuator

HDBGCA full range ofelectrodesAA Compatible with a range of SafeAir electrodes and ColoradoNeedlesB Tactile buttons provide security and control; available in pushbutton or rocker switchC Ergonomic design optimises grip and comfortSafeAir electrodesD Fully integrated suction/power cord is light and ultra flexiblefor ease of motion and tangle-free cord management Styles to suit specificneeds (blade, ball, loop andconization) Coated, uncoated and insulatedoptions A variety of diameters/widths(3-20mm), depths (8-20mm)and lengths (60-165mm)E Electrode and suction sleeve telescope simultaneously reducingthe need to change electrodeF Adjustable suction sleeve encircles electrode for smoke captureat any angleG Pencil shaft telescopes up to 120mm, for a smoke inlet reach of127mmH Locking ring secures telescopic shaft at desired lengthSurface use:pencil shaftretracted withsuction sleeveextendedInside open cavities:pencil shaft extendedwith suction sleeveretractedColorado MicroDisection Needles Versatility; 40 configurationsfor microdissection Ultra sharp 5µ tungsten alloytip

The choice is yours:scalable solutionsNeptune 3Waste Management SystemFor the ultimate in streamlined functionality, look tothe Neptune 3 Waste Management System. Not onlydoes it provide smoke evacuation, but also quickly andefficiently suctions and locks away surgical site and floorfluids. The result is a simple way to perform multipletasks while reducing exposure to potential hazards, fromthe floor you walk on to the air you breathe.Safety and efficiency Compatible with SafeAir SmokeEvacuation Pencils Integrated ULPA smoke evacuator filtercaptures potentially hazardous submicronparticulates with 99.999% efficiency6 Auto mode automatically detects surgicalsmoke and adjusts flow Reduces hazardous exposure by suctioningsurgical site fluid, floor fluid and surgicalsmoke Closed system locks away suctioned fluidsduring cases, manifold changes, dockingand transport; reducing exposureand spills Three layers of protection at manifold sitevia SealShut Technology; no open accesspoints to internal canister Enables patient-to-patient usevia simple manifold change

SafeAir Compact Smoke EvacuatorThe SafeAir Compact SmokeEvacuator provides suction forSafeAir Smoke Evacuation Pencilsand is easily portable for use in theoperating theatre or other procedurerooms. It contains many features thatallow you to customise performancesettings to suit the needs of varioussurgeons, patients and procedures.ABA Auto activation via integratedsensor that detects pencil currentB ULPA filtration providesmultiple benefits ULPA media – Capturespotentially hazardoussubmicron particulates Carbon media – activatedcharcoal bed removes volatileorganic compounds and odorsfrom the airCDEFC LED indicator tracks filter life;alerts when filter replacementis neededD Proprietary vacuum designensures instant “on-tip”suction at the desired level No ramp up timerequired to reachdesired suction power Customisable via10 speed settingsE Multiple activation modes:automatic, permanent andfoot switchF Customisable time delay;up to 10 seconds of smokeevacuation after pencildeactivationSimple to use; front panelcoincides left-to-right withchronological setup stepsProCareServicesMinimal sound producingjust 46dBaEasily portable withminimal footprint (13 kg;14cm H x 38cm W x 30cm D)Only ProCare technicians have the proprietary knowledge,tooling and parts to care for your surgical equipment, includingNeptune and Safe Air smoke evacuators, in accordance with ourmanufacturing specifications. The ProCare Protect service planprovides annual preventive maintenance visits, plus unlimitedrepairs, with options like next day loaned equipment, to keepyour Stryker equipment up and running.

SafeAir Smoke Evacuation Pencils & ElectrodesPencil – push button switchPk/40Part numberDescriptionSHK-VS-CLIntegrated smoke evacuation pencil, coated 70mm blade, push button switchSHK-VSLIntegrated smoke evacuation pencil, non-coated 70mm blade, push button switchPencil – rocker switchPk/40SHK-VS-C-RSLIntegrated smoke evacuation pencil, coated 70mm blade, rocker switchSHK-VS-RSLIntegrated smoke evacuation pencil, non-coated 70mm blade, rocker switchTelescopic pencil – push button switchPk/10SHK-TSP-CLIntegrated telescopic smoke evacuation pencil; coated 70mm blade; push button switchSHK-TSPLIntegrated telescopic smoke evacuation pencil; uncoated 70mm blade; push button switchPk/10Suction sleevePart numberDescriptionLengthSHK-EST-0065LSuction tip65mmSHK-EST-0125LSuction tip125mmSHK-EST-0165LSuction tip165mmPk/10Needle electrodesSHK-553-S-70Needle electrode70mmSHK-553-S-70-MDMicroDissection Needle electrode70mmSHK-553-S-125Needle electrode125mmBallPk/10SHK-554-S-3-120Ball electrode 3mm diameter120mmSHK-554-S-5-120Ball electrode 5mm diameter120mmSquared BladePk/10SHK-552-S-70-C-SQ Blade Electrode, 70mm, Coated, Square70mm

Pk/10BladePart numberDescriptionLengthSHK-552-S-70-CBlade electrode coated70mmSHK-552-S-70Blade electrode70mmSHK-552-S-70-CIBlade electrode coated and insulated70mmSHK-552-S-70-CI2Blade electrode coated and insulated, 2mm tip70mmSHK-552-S-125-CBlade electrode coated125mmSHK-552-S-125Blade electrode125mmSHK-552-S-125-CIBlade electrode coated and insulated125mmSHK-552-S-165-CBlade electrode coated165mmSHK-552-S-165Blade electrode165mmSHK-552-S-165-CIBlade electrode coated and insulated165mmLoop and conizationPk/10Part nization electrode13mm15mm120mmSHK-C1320-S-120Conization electrode13mm20mm120mmSHK-C1608-S-120Conization electrode16mm8mm120mmSHK-C1618-S-120Conization electrode16mm18mm120mmSHK-C2020-S-120Conization electrode20mm20mm120mmSHK-T1010-S-120Loop t-bar electrode10mm10mm120mmSHK-T1512-S-120Loop t-bar electrode15mm12mm120mmSHK-T2015-S-120Loop t-bar electrode20mm15mm120mmSHK-T2020-S-120Loop t-bar electrode20mm20mm120mmSHK-T2015-S-60Loop t-bar electrode20mm15mm60mmSHK-T2020-S-60Loop t-bar electrode20mm20mm60mmSHK-U2020-S-120Loop u-bar electrode20mm20mm120mmThe Neptune SafeAir Smoke Evacuation Pencils are also compatible with Stryker’s full offering of the Colorado MicroDissection needles.

Neptune Waste Management SystemPkNeptune 3 HardwarePart numberDescription0703-002-000ENGNeptune 3 Rover10702-015-000Docking station (230V)1PkNeptune 3 Disposables0702-020-0004-Port manifold200702-020-0014-Port manifold with specimen collection200702-034-000Fluid suction HEPA filer with activated carbon40700-001-026Neptune docking station detergent2PkNeptune 3 Smoke Evacuation0702-040-000Smoke evacuator ULPA filter40700-025-0007/8” x 10’ Smoke evacuation tubing100700-528-001Tubing adapter 6mm x 22mm10700-528-020Tubing adapter 10mm x 22mm1Compact Smoke EvacuatorCompact smoke evacuatorPkSFR-COMPACTCompact smoke evacuator, stand alone1SFR-FIL-CULPA filter, compact smoke evacuator24SFR-CONSmoke tubing for canister/fluid trap10SFR-FSWFoot pedal, compact smoke evacuator1SFR-GCGrounding cable, compact smoke evacuator1This document is intended solely for the use of healthcare professionalsA healthcare professional must always rely on his or her own professional clinical judgment when deciding whether to use aparticular product when treating a particular patient. Stryker does not dispense medical advice and recommends that healhcareprofessionals be trained in the use of any particular product before using it in surgery. The information presented is intended todemonstrate the breadth of Stryker product offerings. A healthcare professional must always refer to the package insert, productlabel and/or instructions for use before using any Stryker product. Products may not be available in all markets because productavailability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representativeif you have questions about the availability of Stryker products in your area. ProCare service plans will be subject to the termsand conditions outlined in the service contract.Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarksor service marks: SafeAir Neptune, ProCare, Stryker. All other trademarks are trademarks of their respective owners or holders.The medical devices depicted are CE marked in accordance with applicable EU Regulations and Directives. The material is notintended for distribution outside the EU and EFTA.References:1. Recommended Practices for Electrosurgery (AORN; 2013;123-41)2. 20. Brandon H.J. et al. “Characterization and removal of electrosurgical smoke.” Surg Serv Manage 3.3(1997): 14-16.3. McCormick, P. “Bovie Smoke a Perilous Plume.” AANS Neurosurgeon 17.1 (2008): 10-12. Web. AccessedMarch 3, 2016.4. Association of Perioperative Nurses (AORN). “Position Statement on Surgical Smoke and Bio-Aerosols, andRecommended Practices for Electro-, Laser and MIS Surgery.” AORN Management of Surgical Smoke. WebAccessed March 3, 2016.5. National Institute for Occupational Safety and Health (NIOSH). “Control of Smoke from Laser/ElectricSurgical Procedures.” Hazard Control Alert HC11: (DHHS Publication #96-128). Web. Accessed March 3,2016.6. Stryker Instruments engineering data on file, September 2015, Kalamazoo, MIStryker European Operations B.V.Herikerbergweg 1101101 CM AmsterdamNetherlands P: 31 20 219 2600SMACC number:2018-19323 Rev None RK/2PM 2018 Stryker www.stryker.com

the Neptune 3 Waste Management System. Not only does it provide smoke evacuation, but also quickly and effi ciently suctions and locks away surgical site and fl oor fl uids. The result is a simple way to perform multiple tasks while reducing exposure to potential hazards, from the fl oor you walk on to the air you breathe.