Hydronic Heating and Coolingwith Air-to-Water Heat Pumps and Hydronic Fan CoilsCOMFORTWhen YouNEED IT

SpacePak’s Solstice heat pumps are air-to-water reverse cycle heat pumps that usethe comfort of Hydronics as the primary source for both heating and cooling demands.In any season, SpacePak units provide perfectly conditioned air with reliability and efficiency.Solstice heat pumps work similar to conventional heat pumps by circulating refrigerant, which vaporizes at a low temperaturein its enclosed evaporator, producing additional energy in the process. Further concentration of the conditioned warmvapor occurs in SpacePak’s Inverter compressor raising it to a temperature where it can be circulated through one of themany SpacePak hydronic air handlers for distribution to the occupied space.Flexible SolutionsHeat pumps can be used in many types of applications fromsmall homes with multiple thermostat driven zones, to largehomes and light commercial applications.Perfect for zoning, these units can operate in a loop that canprovide conditioned air to several individual zones utilizingsingle or multiple air handlers, allowing total comfort controlto the occupied space.Whether radiant heating & cooling, domestic hot water,dehumidification, process cooling, or even conventionalwith multiple air handlers SpacePak Solstice heat pumpsoffer application flexibility requiring less equipment outside.Units can be easily installed at ground level, on rooftops oreven in remote locations when necessary.Solstice SeriesAir-to-Water Heat Pumps Simple Piping and PlumbingInstallation and Service FriendlyEasily ZonedGreen Hydronic EnergyExtended Warranty for Certified Contractors:- 10-Year Compressor - Industry Leading!- 5-Year PartsHigh EfficiencySolstice heat pumps utilize a condenser coil that is 30%larger than standard units and operate with a COP of upto 4. Designed for heating in colder climates, SpacePakSolstice products produce up to 67,000 BTU/h, and caneffectively heat in ambient temperatures as low as 0 F.2

Green by NatureAn ultra safe and environmentally friendly design keepsall refrigerant sealed in its powder coated galvanized steelcabinet and outside the occupied space. Heat pump highefficiency compressors operate on R-410A but use only afraction of the refrigerant needed by other systems, whileproviding superior performance and high COP and EER.Solstice heat pumps run quieter than traditional systemswith their dual fan, horizontal discharge configuration andsoft start activation.System LayoutSolsticeKey: Supply ReturnIllustration depicts heating application. Incooling applications chilled water replaceshot water supply lines.3

EXTREMESolstice Extreme, SpacePak’s monobloc low ambient heatpump provides primary heating and cooling even in severeweather climates. Its environmentally friendly design usesEVI technology and the clean efficient characteristics ofhydronics as its primary energy source to deliver perfectlyconditioned air to any occupied space.Standard Features Reliable EVI Copeland CompressorSimple Piping and Pumping with Easy ZoningModulating Fans for Higher EfficienciesMonobloc Design (No On-Site Refrigerant Charging)Low Ambient Freeze Protection37,500 BTU/h at -5 F AmbientEnhanced Vapor Injection (EVI)The award winning EVI technology and high efficiencycondenser used in SpacePak low ambient heat pumps, providesimproved efficiency, reliability and heating capacities. EVIincreases heating capacity by over 30%, making it the perfectcompressor for severe ambient conditions (0 F) in cold climates,while maintaining the ability to cool during the summer months.Dynamic Exhaust ValveEVI TubeDynamic ScrollMotor4

EXTREMEDimensions (In Inches)SpecificationsModelHeating Capacity (47 F/8 C Ambient temp. 120 F/50 C Supply Water)Heating Capacity (17 F/-8 C Ambient temp. 120 F/50 C Supply Water)Heating Capacity (5 F/-15 C Ambient temp. 120 F/50 C Supply Water)Cooling Capacity (95 F/35 C Ambient temp. 44 F/6.7 C Supply Water)VoltsMinimum water supply temperatureMaximum water supply temperatureMinimum operating ambient temperatureMaximum operating ambient temperatureMinimum water flowRated water flowPressure drop at recommended flowHeating currentCooling CurrentNoise level at max fan speed (Heating or Cooling)CompressorInstalled weightLAHP - 04866,480 BTU/h (18.9kW)46,440 BTU/h (13.6kW)42,240 BTU/h (12.4kW)40,000 BTU/h (11.7kW)230V/1ph/60Hz42 F (5.5 C)131 F (55 C)-8 F (-22 C)105 F (40 C)10 GPM (37.9 l/min)11 GPM (41.6 l/min)17.1 ft/7.4 PSI (35.8 kPa)31A23.5A62 dB (A)EVI Scroll386 lbs (175 kg)COP3.262.352.122.435

EXTREMEPerformanceLAHP Heating OperationAmbientTemp FCapacityBTU/hrWater DPft 9,804All data based upon pure water @ 11.0 GPM110SupplyWaterTemp FAmbientTemp FCapacityBTU/hrWater DPft 24447LAHP Heating Performance80,00072,000Supply WaterTemp F130HEATING CAPACITY, 2.0024,00016,000-10-505101520253035OUTDOOR AMBIENT TEMPERATURE, F4045501.00Coefficient of PerformanceSupplyWaterTemp FLAHP Cooling OperationAll data based upon pure water @11.0 8,000Supply WaterTemp 57075808590OUTDOOR AMBIENT TEMPERATURE, FAll data based upon pure water @11.0 GPM6950.0100Coefficient of PerformanceCOOLING CAPACITY, BTU/hr40,000

INVERTER SERIESThe Solstice Inverter Monobloc (SIM) air-to-water heatpump uses inverter compressors and DC driven fan motorsfor optimal load matching and has an advanced touchscreen control for easy user interface.Keeps all refrigerant conveniently located outside thehome and is capable of low ambient cooling.Available in 3 and 5 ton models.Features and Benefits Reliable Mitsubishi Inverter CompressorUser Friendly Touch Screen ControlPrecision Temperature Control PlatformMonobloc Design (No On-Site Refrigerant Charging)Low Ambient CoolingFreeze ProtectionLow Amp Draw with Ultra Quiet Operation30% More Efficient than Traditional Heat PumpsSpecificationsModelMax Heating Capacity* (90hz)Min Heating Capacity* (30hz)Max Cooling Capacity** (90hz)Min Cooling Capacity** (30hz)COP *EER**Max Running AmpsCompressor Rating LoadLocked Rotor AmpsMinimum Circuit AmpacityMax Fuse or Circuit BreakerPower SupplyCompressor QuantityCompressor ModelFan QuantityFan Power InputFan Rotate SpeedSound @ 3ftWater Pressure DropWater ConnectionWater Flow VolumeUnit Net Dimensions (L/W/H)Unit Shipping Dimensions (L/W/H)Net WeightShipping Weight*47 F Amb. LWT 113 F**95 F Amb. EWT 54 F/LWT 44 FBTU/hBTU/hBTU/hBTU/hAAAAAWRPMdB(A)ft H2Oin.GPMin.in.lb.lb.SIM-03639240119503412111341Up to 5.01Up to 13.4189.7352030230/1N /60Hz1Mitsubishi 6300219864947616445Up to 4.67Up to 15.62119502640230/1N /60Hz1Mitsubishi Rotary2200 275058101 1/41339x17x5242x18x53326368User friendly touch screen control allows for control outside by the unit orinside in the mechanical room.7

INVERTER SERIESDimensions (In Inches)SIM-0362X 1" NPTSIM-0602X 1 1/4" NPT8

INVERTER SERIESPerformanceSIM-036 Heating, 45 F Ambient TempSIM-036 Cooling, 45 F Water TempCompressor WaterFrequency Temp FCapacityBTU/hrWater DPPSIWattsCOP9511313195601131319590113131All data based upon 7.4 ompressor WaterFrequency Temp FCapacityBTU/hrWater 2.862.822.732.64708295708295708295306090SIM-036 HEATING PERFORMANCE, 45 F AMBIENT TEMPSIM-036 Heating Performance, 45 F Ambient 16.0FREQUENCY,15.0HEATING CAPACITY, 9.016,0008.07.012,0006.0Coefficient 51101151201251300.0135SUPPLY WATER TEMPERATURE, FSIM-036 COOLING PERFORMANCE, 45 F SUPPLY WATER TEMPSIM-036Cooling Performance, 45 F Supply Water Temp36,00018.017.032,00016.015.0 COMPRESSORFREQUENCY, Coefficient ofPerformanceCOOLING CAPACITY, BTU/hr13.024,0000.0100OUTDOOR AMBIENT TEMPERATURE, F9

INVERTER SERIESPerformanceSIM-060 Heating, 45 F Ambient TempSIM-060 Cooling, 45 F Water TempCompressor WaterFrequency Temp FCapacityBTU/hrWater DPft WCWattsCOP9511313195601131319590113131All data based upon 10 -30Compressor WaterFrequency Temp FCapacityBTU/hrWater DPft 62.772.682.59708295708295708295306090SIM-060 HEATING PERFORMANCE, 45 F AMBIENT Coefficient ofPerformanceHEATING CAPACITY, BTU/hrSIM-060 Heating Performance, 45 F Ambient Temp1.0135SUPPLY WATER TEMPERATURE, FSIM-060 COOLING PERFORMANCE, 44.6 F SUPPLY WATER TEMPSIM-060Cooling Performance, 44.6 F Supply Water Temp17.052,00016.048,00015.044,00014.0 COMPRESSORFREQUENCY, TDOOR AMBIENT TEMPERATURE, F90950.0100Coefficient ofPerformanceCOOLING CAPACITY, BTU/hr11.016,000103012.036,000

INVERTER SPLIT SERIESSpacePak’s newest air-to-water heat pump systemincorporates ultra-high efficient inverter technology. SISheat pumps use Panasonic EVI inverter compressors foroptimum performance at temperatures down to -20 F.Its’ split-type construction provides installers with theflexibility to eliminate the use of glycol in the hydronic loopand the convenience of simple piping similar to typicalresidential wall-hung boilers.SIS units seamlessly adjust output for specific loadmatching through modulation while maintaining precisiontemperature control. Our EC controlled modulating fanmotors and integral control platform eliminate start/stopcycling resulting in superior performance with less wearand tear on the equipment.Features and Benefits Reliable Panasonic EVI Inverter CompressorSimple Indoor Piping Similar to Wall Hung BoilersDesigned for High Performance in all Temperature RangesExtreme Low Ambient Heating Performance to -20 FSIS System Includes both Indoor and Outdoor UnitsSplit Design Provides the Flexibility to Eliminate the Useof Glycol in the Hydronic Loop EC Controller Modulating FansOutdoor UnitUnits use inverter driven compressorswith EVI technology for superiorperformance efficiency at temperaturesas low as -20 F.Dimensions (In Inches)Indoor UnitEC controlled modulating fan motorscombined with high efficiency bladeprofile ensure quiet end efficientoperation while exchanging energywith the outdoor air.Indoor Unit29.5"17.3"13.6"11

Model:P10(O)Valve cover61Dimensions (In Inches)73Outdoor UnitElectrical componentsbehindpanel. boxElectrical54.7"2WireholesholesWire15.6"4 15.0"525.6"635.5"7Valve coverValvecover3.7"1SpecificationsUnit mm3.4"3OutdoorIndoorHeating Capacity Range*Btu/Hr20,473-71,574Heating Efficiency*COP 1UpModels2345 To 3.09 67Heating Capacity Range**Btu/Hr14,777-47,315Heating Efficiency**COPUp to 2.15Cooling Capacity Range***Tons 93.52.5-5.2 650139087.5397380900Cooling Efficiency***EER12.5Cooling Efficiency****IPLV17.14Water Temp RangeDeg F41-130Compressor FrequencyHz30-90Power erantR410ARefrigeration Connection3/8 & 5/8 FlareCompressorPanasonic Inverter-Drive EVI ScrollN/AWater ConnectionN.P.T.N/A1"Pressure drop (12 G.P.M)P.S.I/ft W.C.N/A10.7/24.7Fan Motor (Modulating)EC ControlledN/ANoise Level (@3meters)dbA5038Net WeightLbs293132Shipping WeightLbs337158Net Dimensions (L/W/H)Inches35x15x5517x14x30Shipping Dimension (L/W/H)Inches37x17x5533x21x17Operating Ambient TempDeg F-20-110*Water out- 120 F, Ambient- 47 F, G.P.M-12**Water out- 120 F, Ambient- 17 F, G.P.M-12***Water out- 45 F, Ambient (DB/WB)@- 95 F/86 F, G.P.M-12****IPLV is the recognized measurement of efficiency for Integrated Part Load Values in accordance with AHRI 550/590.Ambient temp 95 F. Delivered Water 44 F (8.5GPM)All data based on pure waterHeatingCoolingHZWater Temp AmbientCapacitykWCOPHZWater Temp 4.3012.4510.8315.8212.5310.929.49

B U FFER TA N KHydronic buffer tanks are used as both hydraulic separatorsand hydronic buffer tanks. As a hydraulic separator, buffertanks separate the energy source loop (heat pump/boiler)from the hydronic flow in the distribution system (airhandlers/emitters). Hydraulic separation is used primarily insystems where flow rates from the source to the distributionvary or with applications utilizing variable speed pumps. Theheating or cooling source can be hydraulically decoupledfrom the distribution system.Buffer tanks are used as hydronic buffer tanks in systemshaving several low BTU cooling or heating loads callingat different times or systems operating below the designload condition.Buffer tanks store the additional system volume and energycurrently not utilized by the system for use on additionalcalls for heat leading to more efficient system performanceand longer equipment life.There are four piping connections built into the buffertank units (1½" NPT on BT-13-H, BT26-H and BT40-H, 2"NPT on BT80-H). Two connections can be piped to thedistribution system.Features and Benefits Durable Stainless Steel ConstructionPolyurethane Resin Foam with R12 Insulation ValveOffered in 13, 26, 40, and 80 Gallon CapacitiesWhite Outer Housing½" NPT Aquastat PortStandard 6KW* (2 each 3kw Heater Elements for BT26-H,BT40-H and BT80-H. Only one 3kW** heater element forBT13-H) Electric Heat 240VAC 1PH/60Hz*20,500 BTU/hr.**10,250 BTU/hr.13

2-5/83/4 NPT DRAINDimensions-E-DIAMETERTEMPERATURESENSORWELL .250 ID-E-AQUASTAT PORT1/2 NPTDIM -A--E-VENT PORT 3/4 NPTDIM -DDIM -B--EDIM /8"32-1/2"Diameter-A-Dimensions-E-SENSORWELL-E- .250 ID 1-1/2"Port Diameter NPTCapacityUS Gal.Max Water FlowGPMShip Weight3/4 NPT DRAIN1-1/2"4080 DIM -A-363648-E-84104130lbs.7797125Full Weightlbs.304446805Min Circuit mensionsDiameterABCPort Diameter NPTDPort Diameter NPT Capacity EMax Water USFlowCapacityGalMax Water Flow Ship WeightGPMShip WeightlbsEmpty WeightEmpty WeightlbsFull WeightFull WeightlbsMin Circuit AmpacityMin Circuit AmpacityAmpsMax Working PressureP.S.I.Electric Heat CapacitykWDimensions*Not suitable for potable water30SPL-WG1042 BSpecifications142"26Empty WeightDIM -5/8"-E16-1/2"US 2"25 0971259712544680544680530303030100SPL-WG1042 B66

HighWallHYDRONIC HEATING & COOLINGHighWall fan coils are the perfect indoor complement to ourSolstice heat pumps. HighWall fan coils provide optimumheating and cooling in one classic design. HighWall fan coilsare designed for higher volume flow for primary heating incolder climates.All HighWall fan coils feature high efficiency EC motors withstep-less speed modulation which operate from 50-70%more efficient than traditional on/off MHW-18-ECM120 F81231184314641140 F113311655320444Standard Features Low Temperature - Max 160 F Operating Temperature DC Motor W/ Variable Speed Modulation using ECMotor Driver Motorized Adjustable Louvers Quiet Operation (33-58 dB) Elegant Modern Design Heating / Cooling Operation Stainless Steel Flexible Hose Connections LED Display / Remote Control Condensate HoseOutput (BTU/hr)CoolingEntering Water Temperature160 F45 F47 onal Data50 16"Ship Wt.(lbs)283032ThinWallHYDRONIC HEATING & COOLINGThinWall fan coils are the ultra-sleek alternative to HighWallfan coils or can be used in conjunction with a HighWall unitfor optimum flexibility.Perfectly conditioned air is quietly distributed through across-flow blower configuration with integrated air-guidingtechnology. ThinWall units offer versatility for both heatingand cooling while operating up to 30% more efficient thantraditional emitters.Standard Features Quiet Modern Space-Saving DesignHeating and CoolingHydronic Based- No RefrigerantECM BlowerGlass Front Touch Screen ControllerRemote UT-246UT-320120 F46008500114001460017800140 F693610710156062011426010Output (BTU/hr)CoolingEntering Water Temperature160 F45 F48 963320001480012391Dimensional Data50 hHeight5-1/4"24-1/4"Ship Wt.(lbs)415260697915

260 North Elm StreetWestfield, Ma 01085(800) 465-8558www.spacepak.com7555 Tranmere DriveMississauga, Ontario L5S 1L4 Canada(905) 670-5888HPB-5

Max Heating Capacity* (90hz) BTU/h 39240 56300 Min Heating Capacity* (30hz) BTU/h 11950 21986 Max Cooling Capacity** (90hz) BTU/h 34121 49476 Min Cooling Capacity** (30hz) BTU/h 11341 16445 COP * Up to 5.01 Up to 4.67 EER** Up to 13.4 Up to 15.6 Max Running Amps A 18 21 Compressor Rating Load A 9.7 19 Locked Rotor Amps A 35 50