Programmable Logic Controllers (PLC)

Transcription

For the latest prices, please check AutomationDirect.com.lableinONLINEeU.S .andCa n a da o nlyUp-to-date price list:www.automationdirect.com/pricelisttory for FasenhippingtSHuge InvBUYm.coiAvathe at AutolinnDiatio rectmOrder OnProgrammable Logic Controller s (PLC)FREE Technical Support:www.automationdirect.com/supportFREE ct.com/videosFREE onFREE CAD com/cadLocated in LOGIC PLC OverviewmDLV-1

For the latest prices, please check AutomationDirect.com.DirectLOGIC Programmable ControllerOverviewDL05:Offers cost-effectivefeatures with an expansion slotThe DL05 series is a fixed I/O PLC with eight inputs and six outputs with one optioncard slot, and features you won’t find in most bricks — six I/O combinations of AC,DC and relay I/O, and advanced programming functions such as PID.See DS section Eight inputs and six outputs 2 K program memory 4 K data memory Two built-in communication ports Over 250 instructions, including fourPID loops Removable terminal block 12/24 VDC powered versions Discrete and analog I/O modules Thermocouple and RTD modules Ethernet and serial communicationsmodules 1-channel high-speedinput/pulse output module Memory cartridge/real-timeclock module DeviceNet slave modules Basic CoProcessor modulemDLV-2DirectLOGIC PLC OverviewDirectLOGIC Programmable ControllerOverviewDL205:Micro-modular PLC with a wide range of I/Oand communications modulesIf your application requires the flexibility of a modular system, a DL205 PLCis a low cost, yet extremely versatile solution. CPU with 30.4K memory and up to 16,384 I/O Four base sizes available 16 buit-in PID loops AC/DC input/output modules Up to 10 A relay outputs 12-bit and 16-bit analog I/O modules Thermocouple and RTD input modules Ethernet and serial communications modules Ethernet and serialremote I/O High-speedcounter/pulseoutput modules Basic CoProcessor module Ethernet and DeviceNet slavecontroller modules Triple port serial moduleDL06:DL405:The DL06 series combines its fixed I/O of 20 inputs and 16 outputs with fouroption card slots for expansion all in the same package. With the DL06, you canuse the same PLC panel layout for all applications from 36 to 100 I/O.The DL405 PLC product line has a wide choice of specialty I/O modules,including high-speed counting, temperature controller, and magnetic pulse input.Mighty micro PLCwith 36 I/O and four expansion slotsSee DS sectionFor the latest prices, please check AutomationDirect.com. 20 inputs and 16 outputs 7.5 K program memory 7.3 K data memory Two built-in communicationports - one RS232 and oneRS232/422/485 port Over 275 instructions, includingeight PID loops and ASCII Removable terminal blocks Built-in 300 mA 24 VDCauxiliary power supply 12/24 VDC powered versions Built-in real-time clock/calendar Discrete and analog I/O modules Thermocouple and RTD modules Ethernet and serial communicationsmodules High speed input/pulse output module DeviceNet slave modules Basic CoProcessor module Optional plug-in LCD display1-800-633-0405See D2 sectionSpecialty modulesfor complex applications Two CPUs, up to 46.8K memory and16,384 I/O Three base sizes with built-in power supply 16 built-in PID loops AC/DC input/output modules 10 A relay outputs 12-bit and 16-bit analog I/O modules Thermocouple and RTD input modules Ethernet and serial communications modules Ethernet and serial remote I/O master andslave e D4 sectionDirectLOGIC PLC OverviewmDLV-3

For the latest prices, please check AutomationDirect.com.How many other companies offera money-back guarantee on software?DirectSOFT6 programsthe entire DirectLOGICfamilyPC-DSOFT6 is our DirectLOGIC PLCprogramming package, with a host offeatures that make it easier to programyour PLC. It supports full-featured 32-bitWindows-based program ming for all sixDirectLOGIC PLC families simultane ously, including all DL05s, DL06s,DL105s (retired), DL205 CPUs, DL305CPUs (retired), DL405 CPUs, and most oftheir Koyo cousins. The software supportsa wide array of on-line/off-line programming and docu men ta tion features, as wellas IBox instructions.Packages include: PC-DS100/version 6 (FREE):DirectSOFT100 programming package; programs up to 100 words in anyDirectLOGIC CPU PC-DSOFT6 is the full programmingpackage for all DirectLOGIC PLCs with noprogramming limitations, at one low priceDirectSOFT Windows full-featuredprogramming and documentation software, CD or download. For use with allDirectLOGIC PLCs. PC-R60-U upgrade to Version 6 withcomplete DirectLOGIC CPU support fromany older purchased versionDirectSOFT Windows programmingand documentation software upgrade,upgrades current DirectSOFT 16-bit or32-bit software to DirectSOFT v.6.0.Technicians like itwhen you use ourprogramming anddocumentation toolssetup wizard leads you through the stepsto make the connection to your PLCs.What’s New inDirectSOFT6? Over 40 new IBoxes available Configurable toolbars Extremely fast status updates New Trend View feature for monitoringand debugging (seen below) Graphic Ladder View Ladder box leg labels Graphic Stage ViewWhat else is included? IBoxes have packetized fill-in-the-blankstyle instructions that make writing yourprogram faster and easier (certain CPUsand firmware required) Tabbed views optimize your viewing areaso you see more of what you need to see Customizable tool bars give you theflexibility to put what you need where youwant it Dockable windows give you the ability torelocate views, auto-hide views and eventear them away and place them outside ofthe DirectSOFT6 workspace for full ladderviewing optimization Learn many features and softwareshortcuts with the “Tip of the Day” inDirectSOFT6 Edit programs as fast as you can move amouse or use ‘hot keys’ (even faster) Write your program with nicknamesinstead of data points View your program three different ways(RLL, Stage View, Mnemonics). Select theappropriate Tab or view them all on thesame screen Reduced scan time by scanningonly active stages Spreadsheet-style documentation editormakes it super easy to create and edityour program docu menta tion on the fly I/O cross-reference and element usagewindows keep track of addresses used Print Preview to check print formatting Print in COLOR Open a Data View to examine a statuschart of information you select PID setup is a snap. Fill-in-the-blanks foralarms, mode, ramp/soak, process variable, setpoint, gain rate, etc. PID loop tune and trending screens arestandard Modem support is a snap since it uses thestandard Windows telephony (TAPI)interface to choose modem configuration Our drum timers are the easiest to createand edit in the industry Programming support for all DirectLOGICCPUs ASCII in/out and MODBUS instructions forDL06 and D2-262 CPUs Support for DL205 local I/O expansionsystem in D2-262 and DL-405 CPUs Support for LCD instructions in the DL06CPU Project backup feature and preferenceswith auto-backup settings for “filefreshen” frequency Import/export program (mnemonics andrung comments) allows for archiving aprogram in a single file (txt or CSV) thatdoes not need to be in the form of aDirectSOFT6 file(s) format Export to C-more operator interfaceCSV import format (nickname, type, PLCaddress) to use the same tags in our PLCprogram and operator interfaceconfigurationFor the latest prices, please check AutomationDirect.com.DirectSOFT6 for DirectLOGIC PLCsDirectSOFT6 makes programmingyour PLC easy and fastWe have taken the guesswork out of everyday programming with IBox instructions. The IBox instructions areintelligent modularized instructions that perform simple tocomplex ladder logic. If you need to set up an Analogcard just fill in the blanks; If you need to perform a mathfunction on a value, simply type in your formula; select anew preset for your High Speed Counter (CTRIO); evensend an e-mail with your ECOM100 Ethernet communications module! Take a minute to view the IBox InstructionHelp index to see detailed specifications of each of the105 instructions, review which CPUs support the IBoxinstructions or just get familiar with what they can do foryou. Other features include: Point and click or function key editing to suit anyone’sprogramming style Customizable Tool Bars for EVERY menu command Desktop Themes to allow you to customize your windowand tool bar look & feel All toolbars can be docked to any border or even floatedoutside of the DirectSOFT window for maximum ladderviewing Write your program with nicknames instead of data points I/O cross reference and element usage windows keep trackof addresses used Set up the D0-DCM for the DL05 & DL06 right from the menu.PLC Setup D0-DCM allows you to configure each of thetwo serial ports, no ladder code requiredThe 40 new IBoxes in DirectSOFT6 are compatible withDirectLOGIC DL05, DL06, D2-262 and D4-450 CPUsthat have supporting firmware, as well as with the newD4-454 CPU. IBox instruction categories include Memory,Discrete Helper, Analog Helper, Math, Communications,and CTRIO.NOTE: Using Ibox instructions can increase the program size and PLC scantime.Stage programming keeps thesequence in orderA well-documented program can savethousands of dollars in downtime whensomething breaks, but not all packagesmake it easy to document the program.Use our grid-based documentation editorto quickly and intuitively create rungcomments, 16-character element nicknames, 6 x 19-character element descriptions, and 16-character wiring labels.RLLPLUS Stage programming can help break a controlproblem into smaller pieces and provide such benefits as: Stages divide the ladder program into sections thatcorrespond to the states in a flowchart of your process Stages help make large programs more manageable bygiving them some structure Reduce scan time by scanning only the active stages Program over EthernetYou can program one or multipleDirectLOGIC PLCs from one location overan Ethernet network. Just insert an ECOM100 module in supported DL05, DL06,DL205 and DL405 systems to monitorand program at warp speed! An EthernetmDLV-4DirectLOGIC PLC OverviewNOTE: For current operating system requirements, please visitthe DirectSOFT6 software page at ondirect.com/directlogic-plcsDirectLOGIC PLC OverviewmDLV-5

For the latest prices, please check AutomationDirect.com.DirectSOFT6 Packages for DirectLOGIC PLCsProgrammingsoftwarePC-DSOFT6DirectSOFT Windowsfull-featured programming and documentation software, CD or download. For usewith all DirectLOGIC PLCs.PC-DS100DirectSOFT Windowslimited programming and documentationsoftware, free download only. For use withall DirectLOGIC PLCs.OverviewDirectSOFT6 Programming Software hasbeen designed to make DirectLOGIC PLCprogramming easier than ever before.The 32-bit Windows-based packageprovides simple menu and icon choicesthat operate similarly to those found inmost standard Windows packages. WithDirectSOFT6 you can have the power ofWindows on the factory floor.To download our free version, please visitour Web site at:www.automationdirect.com/directsoftWhich package is rightfor you?The programming software packagesshare the same general features, butthere are a couple of key differences:PC-DSOFT6 programs all six CPU families(DL05, DL06, DL105 (retired), DL205, DL305(retired) and DL405).PC-DS100 is a free, full-feature softwarepackage that allows a maximum of 100words for programming, editing, anddownloading. Larger programs can becreated and saved but NOT reopened ordownloaded without purchasing the fullversion.Flexible configuration allows you to customize the look and feel of the software to suit your needs and desires.Laptop/portablecomputers andoff-site usageMany of you may be using laptopcomputers for field service work. This isperfectly acceptable as long as it adheresto the guidelines described previously.Can I ship a copy to mycustomer?No, except for a single backup copy, youcannot make, install, or distribute anyadditional copies. You can transfer theoriginal copy (original CD, any applicable upgrades, and any documentation)by taking advantage of our Web registration and ownership transfer site.Maintenance releasesYou can receive maintenance releasesat no charge by downloading them fromour Web site. These often include someminor feature enhancements along withsoftware corrections.Software upgradesPC-R60-U DirectSOFT Windows programming and documentation software upgrade,upgrades current DirectSOFT 16-bit or 32-bitsoftware to DirectSOFT v.6.0. Any release thatcontains major feature enhancements willbe subject to the normal upgrade chargein effect at that time. The DirectSOFT6upgrade part number is PC-R60-U.Note: This upgrade will update any older packagesthat are already installed on your system to a fullprogramming package with all CPU support.Of course, this means you cannot legallykeep a copy once you have transferredthe original.For the latest prices, please check AutomationDirect.com.DirectSOFT6 FeaturesProgram editing features “Tip of the Day” gives you programmingguidance, information on shortcuts andtips for taking advantage of features Full-screen Point and Click Editing withthe mouse and icons Edit Tool Box contains icons and hot keyequivalents for all elements Browsers help you find properaddresses, contacts, coils, and boxinstructions Project Information data with eachproject including creation and savedates, links, PLC type, project descriptionand version, and company/ department/programmer On-screen Cross Reference in a tabbedview that automatically tracks programelements as you browse the ladder view On-screen Element Usage in groups of 8,10, or 16 points per line Predefined aliases for common items,such as timer and counter current values Enter your program with nicknames andassign them to addresses later Access V-memory (Data Registers) withfill-in-the-blank Memory Editor Easily cut and paste single rungs orgroups of rungs Cut and paste rungs (with documentation) between programs Search for program elements by name,address, rung number, or instruction type Search for constantsDocumentation features I mport/export program mnemonics andrung comments to a text file that does nothave to be in DirectSOFT format E xport (nickname, type, PLC address) toC-more in CSV format G rid-based documentation editor foreasy access 16-character nicknames for addressesmake troubleshooting and programmingeasier 16-character wiring information allowsyou to tie PLC addresses to panel wiringnumbers 6-line x 19-character address descriptionprovides more detailed informationabout the program element Rung comments can be up to 20 lines of70 characters each Cut, copy, and paste documentationbetween program elements Free-form program title page can beselected at time of printing Import/Export feature for alldocumentationNumber of usersThe packages listed above are really“single-station” packages. That is, youcan legally install them on only onecomputer. However, if there is only oneperson who primarily uses the computer(over 80% of the time), then you caninstall the software on a laptop, homeoffice, or any other single backupcomputer.Printing features Print any available view, includingladders, charts, and mnemonics Print multiple columns Use zoom to enlarge or reduce print size Preview the printouts before you sendthem to the printer Create custom printouts by selectingexact items to include for each view Print program documentation, includingnicknames, descriptions, rungcomments, etc. Print program Cross Reference orElement Usage Table Print PLC V-memory or Data RegistercontentsDisplay andviewing features Tabbed views allow you to easily switchbetween views and optimize yourviewing area View program ladders Customizable desktop themes, displaycolors for editing, unsaved changes,documentation, etc. View program mnemonics Stage view available for programscreated with RLLPLUS instructions Choose rung number or addresses forladder view View multiple programs at the same time View multiple screens at once Use split screen to view differentsections of the same program Use zoom to enlarge or reduce the screenarea for better viewingSystem setup features D0-DCM Setup menu is available for theDL05 and DL06 data communicationsmodule Set up PID loops with easy-to-use dialogboxes Set PLC communication parametersthrough PC ports, modems, or Ethernet Change PLC mode of operation Clear PLC memory by type or all Select or change retentive memoryranges Read PLC I/O configuration Change I/O configuration (if allowed bythe PLC) View PLC firmware revisionsOnline operationfeatures Online help system with supported CPUinstruction list DSLaunch as a central manager for allprojects, links, and applications Automatically build and storecommunication links to the PLC,even using modems or Ethernet Visible indication of PLC communicationlink status Status mode provides visible power flowcondition for program elements, currentvalues for timers and counters, andcurrent values for V-memory or DataRegister locations. Event status for Drumsteps, outputs, event and/or timetransitions, etc. Custom configure Data View windows tomonitor various elements Display nicknames in Data View Save and store Data View windows byname Choose data format for Data ViewWindow display (BCD, binary,Hexadecimal, etc.) Choose status symbol (switch, text, etc.)for discrete points in Data View windows Change PLC values from Data Viewwindows View multiple PLCs simultaneously(Ethernet)Maintenance anddebugging Automatic error checking duringprogram entry Program syntax check Monitor PLC scan time Perform PLC I/O diagnostics View PLC errors and/or user errormessages Project user backup and autoback-up facilities Visually monitor data values usingthe Trend View featureNOTE: For current operating system requirements, please visit the DirectSOFT6 software page at www.AutomationDirect.commDLV-6DirectLOGIC PLC ectlogic-plcsDirectLOGIC PLC OverviewmDLV-7

For the latest prices, please check AutomationDirect.com.DirectSOFT6 FunctionsDirectSOFT6 FunctionsClick to startprogrammingFor the latest prices, please check AutomationDirect.com.The Launch WindowSupport for drum instructionsThe Launch Window is a centralized location to view not onlyall of your DirectSOFT6 applications and projects, but also anyadditional applications such as NetEdit, DN Loader, CTRIO WB,ERM WB, etc. This window is also used to create and managePLC programs and the communications between your PC andthe PLC.Utilities, such asCTRIO WBIf your PLC supports Drum instructions, you will like this feature of the programmingsoftware. Simply fill in the top of the drum with outputs and configure each step withan event and/or time-based element. Then click on the output boxes to choose theproper output states for each step and you are finished.Installed supportDocuments —(Projects most recentlyused listed first)PID viewCommunication links to PLCsDirectSOFT6 offers an excellent PID feature. The loop and trending screensare very easy to configure. This feature has all of the views, trending, andtuning that you need to easily and successfully set up your PID loop.Point and click editingOnce you have started a new project, there are a few different ways tostart building your program. The Ladder Palette, which is attached to theright border by default, can be resized and repositioned anywhere on yourdesktop. This contains most of the instructions you will need. Simply clickon the icon or use the Hot Key associated with that icon. Some instructions have to be accessed through one of the Browser icons. The Browserscontain all of the necessary information from various boxes, coils, andcontacts. You can now customize the Ladder Palette tool bar to fit yourprogramming style and needs.Description, Wiring Info, Nickname, ElementEnter documentation information for each instruction/element.Edit and review all documentationTrend viewDirectSOFT6 contains a new debugging tool called Trend View.Trend View is used to visually monitor the values of DL controllerdata elements over time. The Trend View can monitor any readablenumeric location, any readable bit location or any constant value.Ladder PaletteI-Box InstructionsDocumentationDocumentation is the text associated with the components andstructure of your program. It helps to clarify the representationof elements by assigning four different fields: Description, WiringInfo, Nickname, and Element.IBox instructions are parameterized fill-in-the-blank instructions designed tomake your programming experience quicker and easier than ever before.Within these IBoxes you will find some complicated and some simple,everyday ladder code tasks made easy and fast. There are 6 categories,including Memory, Discrete Helper, Analog Helpers, Math, Communications& Counter I/O, with 105 instructions to choose from. Here are a few examples of IBox instructions in DirectSOFT6 MOVER - Copies a 32-bit floating point number that is stored in two consecutive V-Memory locations to the specified location which is also two consecutive V-Memory locationOFFDTMR - Off Delay Timer will delay the “turning off” of the Outputparameter by the specified Off Delay TimeOnscreen viewsDirectSOFT6 defaults to a Tab view to give you the most optimized viewing area.You still have the option to view multiple windows in the original “MDI” format bysimply hitting the Restore button in the upper right of the active tabbed window,or go to Windows menu and select one of the tile or cascade options. You canhave multiple windows open to view such things as all of the addresses used in theprogram, a mnemonic view of the program instructions, and all of the instructionsused.mDLV-8DirectLOGIC PLC OverviewYou can have multipleviews of your projectvisible at the sametime. This screen showsthe Ladder View, UsageView, Mnemonic Viewand XRef View.ABSR - Returns the absolute value of the Real (floating point) number foundin the specified V-Memory locationsANLGCMB - Analog Input/Output Combo Module Pointer Setup generatesthe logic to configure the pointer method for one analog input/output combomodule on the first PLC scan following a Program to Run transition.MATHBCD - Math - BCD Format lets you enter complex mathematicalexpressions like you would in Visual Basic, Excel, or C -plcsDirectLOGIC PLC OverviewmDLV-9

For the latest prices, please check AutomationDirect.com.Programming for DirectLOGIC PLCsProgramming for DirectLOGIC PLCsProgramming versionsWith DirectSOFT6 Programming Software,selecting which software package youneed is a snap! You can select the fullyloaded package at its great low price, oryou may choose the FREE package. It hasall of the same programming functionsas the full package. However, it will onlydownload a program up to 100 wordslong.The fully-loaded version (PC-DSOFT6)will program all of our DirectLOGICPLCs, some GE Series One Plus PLCs,and TI305/405 SIMATIC PLCs. Refer tothe chart below to verify compatibility.DL205DL305 (retired)DL405GE Series 1 PLUSTI305 / SIMATIC TI305 TI405 / SIMATIC TI405 Koyo Kostac S-SeriesAlso, you cannot open an offline projectlarger than 100 words. You can create aproject as large as you want and save itto disk, but you cannot reopen or download it to a PLC without purchasing thefull version (PC-DSOFT6).PLC compatibilityIf you’re using our DirectLOGIC products, then compatibility is not an issue.The DirectSOFT6 package supports allDirectLOGIC CPUs. Our software alsosupports many compatible products thatwere offered by previous vendors of theKoyo-designed PLCs. If you’re buyingthe software to program a compatibleCPU, check the following table to makesure your CPU is supported. (Sorry, butif your CPU is not shown, then it is notsupported.)DirectSOFT6(free version)PC-DS100*CPU Firmware VersionNeeded to Use IBoxInstructionsAll444 CPU v5.10 or LaterAllAllD2-230 (retired)D2-240 (retired)D2-250 (retired)D2-250-1 (retired)D2-260 (retired)D2-262D3-340D3-350D4-430 (retired)D4-440 (retired)D4-450 (retired)D4-454IC610CPU105**IC610CPU106**325-07**, PPX:325-07**330-37**, PPX:330-37**325S-07** (or 325 with Stage Kit)330S-37**, PPX:330S-37**335-37, PPX:335-37425-CPU, PPX:425-CPUPPX:430-CPU435-CPU, 4444 CPU v2.10 or LaterCPUConnecting to DirectLOGIC PLCsDL05 CPUsPort 1: 9.6 KbaudPort 2: 300 baud-38.4 KbaudDL06 CPUsPort 1: 9.6 KbaudPort 2: 300 baud - 38.4K baudDirectSOFT6(full version)PC-DSOFT6FamilyDL05DL06DL105 (retired)The FREE DirectSOFT6 package(PC-DS100) was designed to providea more streamlined choice. You cansee from the table below that the FREEversion has the same support and samegreat features, but will only allow you toopen or download a program up to 100words long.For the latest prices, please check AutomationDirect.com.DL105 CPUs(retired)4 CPU v4.60 or Later4 CPU v2.40 or LaterPort 1: 9.6 KbaudDL205 CPUsD2-230 (retired): Port 1: 9.6 KbaudD2-240 (retired): Port 1: 9.6 KbaudPort 2: 300 baud - 19.2 KbaudD2-250-1 (retired): Port 1: 9.6 KbaudD2-260 (retired): Port 2: 300 baud - 38.4 KbaudD2-262: Port 2: 300 baud - 38.4 Kbaud4 CPU v3.30 or LaterDL305 CPUs (retired)D3-340: Port 1/2: 300 baud - 38.4 KbaudD3-350: Port 1: 9.6 KbaudPort 2: 300 baud - 38.4 KbaudDL405 CPUs* PC-DS100 is only available by download from our Website. This FREE, full-featured software package will download a program limited to 100 words.** Requires Data Communications Unit (D3-232-DCU (retired)).mDLV-10DirectLOGIC PLC OverviewOr use an Hx-ECOM100 module in the DL05, DL06, DL205 (except D2-230) orDL405 local base to program over a high-speed Ethernet link.1-800-633-0405D4-430 (retired): Port 1: 9.6 KbaudD4-440 (retired): Port 2: 300 baud - 19.2 KbaudD4-450 (retired): Port 0: 9.6 KbaudPort 1/3: 300 baud - 38.4 KbaudPort 2: 300 baud - 38.4 KbaudD4-454: Port 0: 9.6 KbaudPort 1/3: 2.4 Kbaud - 38.4 KbaudPort 2: 2.4 Kbaud - 38.4 ctLOGIC PLC OverviewmDLV-11

For the latest prices, please check AutomationDirect.com.DirectLOGIC PLC Programming CablesFor the latest prices, please check AutomationDirect.com.DirectLOGIC PLC Programming CablesSince CPUs provide many different communication port possibilities, it is helpful to know exactly whichcommunications cable is required. Use the table below to choose the proper cable:FamilyCPU (or other device)D2-DSCBL (EA-MG-PGM-CBL optional)Port 2D2-DSCBL (EA-MG-PGM-CBL optional)Only one**Port 1D2-DSCBL (EA-MG-PGM-CBL optional)Port 2D2-DSCBL-1Port 1D2-DSCBL (EA-MG-PGM-CBL optional)Port 2D2-DSCBL-1Only one**Port 1D2-DSCBL (EA-MG-PGM-CBL optional)Port 2D2-DSCBL-1F1-130 (all versions)Only oneD2-DSCBL (EA-MG-PGM-CBL optional)D2-230Only oneD2-DSCBL (EA-MG-PGM-CBL optional)Top portD2-DSCBL (EA-MG-PGM-CBL optional)Bottom portD2-DSCBL (EA-MG-PGM-CBL optional)Top portD2-DSCBL (EA-MG-PGM-CBL optional)Bottom portD2-DSCBL-1Top portD2-DSCBL (EA-MG-PGM-CBL optional)Bottom portD2-DSCBL-1Top portD2-DSCBL (EA-MG-PGM-CBL optional)Bottom portD2-DSCBL-1D2-DCM (module)Only oneD3-DSCBL-2H2-ECOM (-F) / ECOM100Only oneTop portBottom port**D3-DSCBL-1D3-DSCBL-1Top portD2-DSCBL (EA-MG-PGM-CBL optional)Bottom portD3-DSCBL-2Only oneD3-DSCBL-2Top port (15-pin)D4-DSCBLBottom port (25-pin)D3-DSCBL-2Phone jackD2-DSCBL (EA-MG-PGM-CBL optional)Top port (15-pin)D4-DSCBLBottom port (25-pin)D3-DSCBL-2Phone jackD2-DSCBL (EA-MG-PGM-CBL optional)Top port (15-pin)D4-DSCBLBottom port (25-pin)D3-DSCBL-2D4-DCM (module)Only oneD3-DSCBL-2H4-ECOM (-F) / ECOM100Only one**Slice I/O (module)Only oneD4-DSCBLIC610CPU105/106Requires DCU*D3-DSCBL-2325-07, PPX:325-07Requires DCU*D3-DSCBL-2330-37, PPX:330-37Requires DCU*D3-DSCBL-2Requires DCU*D3-DSCBL-2Requires DCU*D3-DSCBL-2Phone jackD3-DSCBL-1If DCU is used*D3-DSCBL-215-pin portD4-DSCBLTop port (15-pin)D4-DSCBLBottom port (25-pin)D3-DSCBL-2Top port (15-pin)D4-DSCBLBottom port (25-pin)D3-DSCBL-2Only oneD4-DSCBLH0-ECOM / ECOM100 (modules)D0-DCM (module)All versionsDirectLOGIC DL06H0-ECOM / ECOM100 (modules)D0-DCM (module)DirectLOGIC DL105(retired)D2-240D2-250(-1)(D2-250-1 CPU is retired)DirectLOGIC DL205D2-260D2-262D3-340DirectLOGIC DL305(retired)D3-350D3-DCM (module)D4-430/D4-440 (retired)D4-450 (retired)DirectLOGIC DL405D4-454GE Series 1325S-07 (or 325 with stage kit)TI305 /SIMATIC TI305 330S-37, PPX:330S-37335-37, PPX:335-37425-CPU, PPX:425-CPUTI405 /SIMATIC TI405 CablePort 1All versionsDirectLOGIC DL05PortN/A, PPX:430-CPU 435-CPU, PPX:435-CPUSmart sliceD2-DSCBL 29.00D2-DSCBL-1 56.00D3-DSCBL-1 60.00D3-DSCBL-2 55.00D3-350 (bottom port)orDL405 CPU (bottom port)orDL205/405 DCMorDL305 w/DCURS-232D4-DSCBL 62.00Straight-through Patch Cable (Ethernet)Crossover Cable (Ethernet)* Requires RS232 Data Communications Unit (D3-232-DCU (retired)).**Requires standard Ethernet twisted pair cable (HX-ECOM) or standard fiber optic cable (HX-ECOM-F).***The GoldX USB-RS232 adapter is another option for USB communication.mDLV-12DirectLOGIC PLC ectlogic-plcsDirectLOGIC PLC OverviewmDLV-13

DirectLOGIC Programmable Controller Overview DL05: Offers cost-effective features with an expansion slot The DL05 series is a fixed I/O PLC with eight inputs and six outputs with one option card slot, and features you won’t find in most bricks — six I/O combinations of AC, DC and r