COMPACT – FLEXIBLE – PRECISE

Transcription

Smart Energy & Power Quality SolutionsPortable energy measurement devicesCOMPACT – FLEXIBLE – PRECISE

Smart Energy & Power Quality SolutionsPortable energy measurement devicesCOMPACT – FLEXIBLE –PRECISEThe portable energy measurement devices from JanitzaStay flexible with the portable energy measurement devicesfrom Janitza. Depending on the variant, the portable energymeasurement devices are equipped with a UMG 96RM-E orUMG 512-PRO. This enables residual current and power quality(harmonics, short term interruptions, unbalances, etc.), forexample, to be measured anywhere. The portable energymeasurement devices are simple to use and integrate. They arethe right choice for any application, thanks to a highly flexiblemeasurement range from 100-4000 A.The MRG 512-PRO PQ Flex measures harmonics up to the63rd. harmonic, as well as flicker and short term interruptions.The MRG 512-PRO PQ Flex can be used for high-qualitynetwork analysis at class A level (IEC 61000-4-30), validation of2Phone: 1800 987 616the device accuracy, for example, and much more besides. TheGridVis visualisation software GridVis -Basic is available forfree download. There are no gaps in the measurement in theevent of power outages thanks to three-hour UPS buffering.The device also has PLC functionality.The MRG 96RM-E RCM Flex measures harmonics up to the40th. harmonic. Possible uses include the analysis of electricaldisturbances in the event of network problems, high qualitycomparative measurement of energy measurement devices andmeters or the acquisition of residual currents via external currenttransformers. The GridVis -Basic software is also available forfree here too.Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsPortable energy measurement devicesThe advantages Flexible measurement of the power quality and theresidual current Cost-effective, robust and compact network analysers Simple use and rapid integration of the measuring case Large measurement range of 100–4000 A throughRogowski current transformer with measurement rangechangeover Acquisition of all power quality parameters (harmonics,short term interruptions, unbalances, etc.) – dependingon the model Remote access via Ethernet and embedded web server GridVis PQ analysis software Standard PQ reports, depending on model:EN 50160, IEEE519, ITIC, IEC 61000-2-4 Cost centre report Large 256 MB internal memory for recordingmeasurement data Avoidance of measurement gaps in the event of poweroutages thanks to the three-hour UPS buffering (onlywith MRG 512-PRO PQ Flex) Measurement up to 63rd. harmonic(MRG 512-PRO PQ Flex) 3Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 512-PRO PQ FlexComplete package – portable powerquality analyser incl. accessories:1 MRG 512-PRO PQ Flex4 Voltage pickoffs with fuses, black(gripping probes)1 Voltage pickoff with fuse, blue(gripping probe)1 Voltage measurement set(brown, black, grey, red, blue)4 Rogowski coils with connection cablesand plugs1 Cross patch cable, CAT 5e2 Connection cables with plugs for residualcurrent monitoring, 3 m (residual currenttransformer not included in the scope ofdeliverables)4Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 512-PRO PQ FlexMRG 512-PRO PQ FLEXPortable class A power quality analyser for monitoring the power qualityCommunication Modbus TCP TCP/IP BACnet (optional) HTTP FTP (file transfer) TFTP NTP (time synchronisation) SMTP (email function) DHCP SNMPInterfaces EthernetRCM – Residual Current Monitoring 2 residual current inputsPower quality Harmonics up to the 63rd. harmonic Interharmonics for U and I Distortion factor THD-U / THD-I / TDD Measurement of positive, negative andzero sequence component Rotary field direction detection Voltage crest factor Acquisition of short term interruptions(from 20 ms) Transient recorder ( 50 μs) Start-up currents (from 20 ms) Unbalance Flicker measurement per EN 61000-4-15 Display of waveformsPLC functionality Graphical programming Jasic programming languageNetworks TN, TT networks 3 and 4-phase networks Up to 4 single-phase networksNetwork visualisation software GridVis -Basic (in the scope of supply)Rogowski coil (Ø 190 mm) 100 – 4,000 A Measurement ranges 100 A, 250 A, 400 A,630 A, 1000 A, 1500 A, 2000 A, 4000 ABuffered UPS Up to 3 hrs(1)Potentiometer(2)DIP switch5Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 512-PRO PQ FlexThe portable MRG 512-PRO PQ Flex power quality analyser withthe integrated UMG 512-PRO class A measurement device canbe used in a variety of applications. This device can be usedto measure harmonics up to the 63rd. harmonic and detectshort term interruptions. The device records residual currents,is buffered with a UPS for up to 3 hours and has an Ethernetinterface for communication via various protocols.applications with large conductor cross-sections. The Rogowskicurrent transformers are also preferable to ferrite core currenttransformers with regard to higher frequencies (harmonics).Large measurement data memoryThe large measurement data memory also enables long-termrecordings, such as are required for the one-week power qualityanalysis per EN 50160, for example.Rogowski current transformer includedin the scope of supplyThe flexible Rogowski coils offer a great advantage, particularly inExample connection – voltage measurementL4L1L2L3Example connection – current measurementI5NI6I1PEPENNI2I3INL1L1L2L2L3L3Rogowski coilVoltage measurementterms connectionsRCM measurement cable6Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 96RM-E RCM FlexMRG 96RM-E RCM FLEXCost efficient and multifunctional network analyser(incl. residual current monitoring)Communication Modbus TCP TCP/IP BACnet (optional) HTTP FTP (file transfer) TFTP NTP (time synchronisation) SMTP (email function) DHCP SNMPInterfaces EthernetRCM – Residual Current Monitoring 2 residual current inputsPower quality Harmonics up to the 40th harmonic Interharmonics for U and I Distortion factor THD-U / THD-I / TDD Measurement of positive, negative andzero sequence component Rotary field direction detection Voltage crest factor Recording of short term interruptions Start-up currents (from 20 ms) UnbalanceNetworks TN, TT networks 3 and 4-phase networks Up to 4 single-phase networksNetwork visualisation software GridVis -Basic (in the scope of supply)Rogowski coil (Ø 190 mm) 100 – 4,000 A Measurement ranges 100 A, 250 A, 400 A,630 A, 1000 A, 1500 A, 2000 A, 4000 A(1)Potentiometer(2)DIP switch7Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 96RM-E RCM FlexComplete package – portable energymeasurement device incl. accessories:1 MRG 96RM-E RCM Flex4 Voltage pickoffs with fuses, black(gripping probes)1 Voltage pickoff with fuse, blue (grippingprobe)1 Voltage measurement set (brown, black,grey, red, blue)4 Rogowski coils with connection cablesand plugs1 Cross patch cable, CAT 5e2 Connection cables with plugs for residualcurrent monitoring, 3 m (residual currenttransformer not included in the scope ofdeliverables)8Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 96RM-E RCM FlexThe compact MRG 96RM-E RCM FLEX is suitable for energyaudits, for recording the residual current and measuring powerquality parameters – anywhere it is required! It has 256 MBmemory and can save minimum and maximum values.Furthermore, it is also equipped with an Ethernet interface.Example connection - voltage measurementL1L2L3Rogowski current transformer included in the scope of supplyThe flexible Rogowski coils offer a great advantage, particularly inapplications with large conductor cross-sections. The Rogowskicurrent transformers are also preferable to ferrite core currenttransformers with regard to higher frequencies (harmonics).Example connection - current measurementI5NI6I1I2I3INPEPENNL1L1L2L2L3L3Rogowski coilVoltage measurementterms connectionsRCM measurement cable9Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsMRG 96RM-E RCM FlexMRG 512-PRO PQ Flex52.16.90652.16.905 Harmonics per order / current and voltage1. – 40.1. – 63.Harmonics per order / active and reactive power1. – 40.1. – 63.Interharmonics - current / voltage- Flicker: Short term, long term, present- 256 MB256 MB300 V CAT III600 V CAT IIILCD display withbacklight, 2 buttonsColour graphical display320 x 240,256 colours, 6 buttonsMRG 96RM-E RCM FlexMRG 512-PRO PQ FlexItem numberInterfacesTechnical dataEthernet 10/100 Base-TX (RJ-45 socket)Measurement of the power qualityMeasured data recordingMemory (Flash)Measured voltage inputOvervoltage categoryDisplays and inputs / outputsLCD displayGeneralUse in low and medium voltage networks Accuracy of measurement with voltage0.2 %*10.1 %*1Accuracy of measurement with current0.2 %*10.1 %*1Class 0.5SClass 0.2S426512 Accuracy of measurement with active energy (kWh, /5 A)Number of measurement points per periodUninterrupted measurementRMS - momentary valueCurrent, voltage, frequency Active, reactive and apparent power / total and per phase Power factor / total and per phase Voltage, current / actual and maximum Active, reactive and apparent power / actual and maximum Frequency / actual and maximum Requirement calculation mode (bi-metallic function) / thermal Operating hours measurement Clock Distortion factor THD-U in % Distortion factor THD-I in % Current and voltage, positive, zero and negative sequence component Transients- 39 µsError / event plotter function Short term interruptions Oscillogram function (wave form U and I)- Under and overvoltage recording Mean, minimum, maximum values Alarm messages Time stamp freely user-definedfreely user-defined Energy measurementActive, reactive and apparent energy [L1, L2, L3, L4, Σ L1–3,Σ L1–4]Recording of the mean valuesOther measurementsMeasurement of the power qualityMeasured data recordingTime basis mean valueRMS averaging, arithmetic10Phone: 1800 987 616Email: industrial@cse-uniserve.com.auWeb: www.cse-uniserve.com.au

Smart Energy & Power Quality SolutionsDisplays and inputs / outputsAnalogue inputs (RCM, analogue)Voltage and current inputsPassword protectionMRG 96RM-E RCM FlexMRG 512-PRO PQ Flex L1, L2, L3 Nevery 4 CommunicationProtocolsModbus TCP, Ethernet HTTP (homepage configurable) SMTP (email) NTP (time synchronisation) TFTP (automatic configuration) FTP (file transfer) SNMP DHCP TCP/IP BACnet (optional) ICMP (Ping) Application programs freely programmable-7Graphical programming- Programming via source code Jasic - Comparator (5 Groups with 10 comparators each) -MRG 96RM-E RCMMRG 512-PRO PQ Flex277 / 480 V AC417 / 720 V AC480 V AC600 V ACGridVis -Basic software included in the scope of supply*2Programming / threshold values / alarm managementTechnical dataNominal voltage, three-phase, 4-conductor (L-N, L-L)Nominal voltage, three-phase, 3-conductor (L-L)Measurement in which quadrantsNetworksMeasurement in single-phase/multi-phase networks44TN, TT, ITTN, TT1 ph, 2 ph, 3 ph, 4 ph1 ph, 2 ph, 3 ph, 4 phand up to 4 times 1 phMeasured voltage inputMeasurement range, voltage L-N, AC (without transformer)0*3 to 300 Vrms0*4 to 600 VrmsMeasurement range, voltage L-L, AC (without transformer)0*3 to 520 Vrms0*4 to 1000 VrmsResolution0.01 V0.01 VImpedance4 MOhm / phase4 MOhm / phaseFrequency measuring rangePower consumption included– not included*1 Accuracy of the portable energymeasurement device may deviate* O ptional additional functions withthe packages GridVis -Professional,GridVis -Service andGridVis -Ultimate.2*3 The UMG 96RM-E can only detectmeasurements when a voltageL1-N greater than 20 Veff (4-wiremeasurement) at voltage input V1 or avoltage L1-L2 greater than 34 Veff (3wire measurement) is applied.*4 The UMG 512-PRO can only determinemeasured values, if an L-N voltage ofgreater than 10 Veff or an L-L voltage ofgreater than 18 Veff is applied to at leastone voltage measurement input.15 to 440 HzApprox. 0.1 VAMeasured current inputRated currentResolutionMetering rangeOvervoltage categoryMeasurement surge voltage1A1A0.1 mA0.1 mA0.005 - 6 Amps0.005 - 7 Amps300 V CAT III300 V CAT III2 kV6 kVPower consumptionApprox. 0.2 VA(Ri 5 mOhm)Approx. 0.1 VA(Ri 5 MOhm)Overload for 1 sec.120 A (sinusoidal)120 A (sinusoidal)20 kHz25.6 kHzSampling rateMechanical propertiesWeightApprox. 3.4 kgApprox. 14.2 kgDevice dimensions in mm (L x W x H)350 x 295 x 150approx. 500 x 390 x 230Front: IP40; Back: IP20Front: IP40; Back: IP20CE labellingCE labellingProtection class per EN 60529SecurityEuropeTechnical dataComment:For detailed technical information, pleaserefer to the operation manual and theModbus address list.45 to 65 HzApprox. 0.1 VA

Rogowski current transformer included in the scope of supply The fl exible Rogowski coils offer a great advantage, particularly in applications with large conductor cross-sections. The Rogowski current transformers are also preferable to ferrite core current transformer