Section Updated 07 / 2014 Panelboards Section 11

Transcription

Section Updated 07 / 2014PanelboardsSection 11— FE as a main breaker in A-Series Panelboards: ExpandingGE’s selectivity offering. The FE main breaker in A-Series allowsfull instantaneous selectivity, which can be coordinated withupstream and downstream GE breakers.— A-Series Branch Circuit Monitoring (BCM): This new energymanagement product allows for monitoring key electrical parameters down to a branch circuit level. This product is factoryinstalled which makes for a clean installation and reduced laborin the field.— AS style A-Series panel: New AE subtype panel, AS, allows forthe combination of expanded selectivity and fully rated solutionup to 65kAIC at 480V. This solution also decreases overall footprints of our panelboard, which has an important aspect ofcurrent day installations.A-Series PanelboardsApplications.11-3Types.11-4Terminal Lugs .11-7Pricing and Ordering .11-8Column Panels .11-9Column – Field Installed Kits/ReplacementParts/Enclosures.11-10Lighting Control Panel—Remote OperatedCircuit Breakers.11-11Pro-Stock Panelboards – Unassembled.11-13Product Options .11-19Accessories .11-20Power Panelboards .11-21Branch Circuit Monitoring.11-23Spectra Series Panelboards .11-24Fusible Switches Load and Interrupting Ratings .11-25Merchandisable Kits and Sizing Information.11-27Terminal Lugs.11-28PCU Selection.11-29Interior, Enclosure Options.11-30Integrated Submetering Panelboard.11-32Renewal Parts Modular Concept.11-33Renewal Parts Circuit Breaker Sizing.11-34Replacement Boxes and Fronts .11-35Renewal Parts Product Number Structure .11-37Renewal Parts – Mounting Hardware .11-40Renewal Parts – Main Lug Modules;Neutral and Ground Kits.11-45Renewal Parts – Accessories.11-46Renewal Parts – Interiors, Boxes and Fronts .11-47Renewal Parts – Type SCP Panelboards .11-48Renewal Parts – Type CCB and QMR Panelboards .11-49Available Publications .11-52Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog11-1

This page left blank intentionally.11-2BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

PanelboardsA-Series Section 11PanelboardsApplicationsStandardsAll GE panelboards meet the latest revision of the followingstandards.—National Electrical Code-Ref. Article 384.—UL67 panelboards: UL50 cabinets and boxes. UL943 GFCI.—UL489 molded case circuit breakers. UL98 fusible switches.—CSA or C-uL listing for Spectra Series Power Panelboards.—C-uL Listing for A-Series non-service entrance panelboards—International Building Code Seismic Zone 3 and 4.—California Building Code Seismic Zone 4.—NEMA PB1.—Federal Specifications—Panelboards, W-P-115c.Type 1—Circuit breaker equippedClass 1—PanelboardsClass 2—Load centers—Molded case circuit breakers, WC-375B/GEN.—Fusible switches, W-S-865c.ApplicationFeaturesThe following classifications and limitations of panelboards havebeen established by the Underwriters Laboratories and theNational Electrical Code. Note— “an overcurrent protective deviceis a circuit breaker pole or single fuse”. Panelboards have no firewall ratings. All 50/60 Hz rated. There is no limitation as to thenumber and rating of branch circuits, except as determined byavailable enclosures.—Symmetrical design, no required top or bottom mountings—Wide, easy-to-install galvanized enclosures with removableendwalls—Flush or surface mounting—Standard concealed mounting hardware and hinges—Interiors that allow “straight-in” wiring—Split neutralInterrupting Ratings—Circuit BreakersPanelboards have integrated short circuit ratings. When fullyrated, the rating is that of the lowest rated device in the panelboard. When series connected rated, the rating is that of themain device in panel (or remote line side protected device) andbranch-tested/UL Listed combination.Short-Circuit Ratings—Fusible Switch UnitsThe interrupting rating of the fuse must equal or exceed theshort-circuit rating of the switch. If it is lower, then the interrupting rating of the switch is the same as the fuse. Switches have noshort-circuit rating if renewable fuses are used.—Field-installable, UL Listed, 200% neutral for non-linear loads—Branch-bus direct connection—Captive hardware on branch breakers—Short circuit ratings allow up to 100KA @ 480Y/277Vac; 200KA@ 240Vac—Main bus ratings of 125 to 800 amps copper, 125 to 600 ampsaluminum—Spectra RMS and vertically mounted main circuit breakersavailable—Bus-connected TVSS for maximum surge protection—Optional door-in-door or front-hinged-to-box door—Enclosures available in NEMA Type 1, Type 3R/12, Type 4/4XSeismic RatingsAll A-Series Lighting Panels and Spectra Power Panels havebeen tested and certified to meet the International Building Code(IBC) Zone 3 and Zone 4 as well as the California Building Code(CBC) Zone 4.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog11-3

PanelboardsA-Series Section 11PanelboardsTypesType ALService Information:1P, 3W-120/240 Vac3P, 3W-240 Vac3P, 4W-240/120 Vac, 208/120 VacMainsBreakers:100A-THQB, THHQB, TEY, SE, FE225A-TQD, THQD, SF, FE400A-TJD, SG600A-SG800A-SKMain Lug:125-800ABranch Breakers (Plug-in):Amperage-15-100APoles-1, 2, 3Types-THQL, THHQL, TXQLEnclosuresLength-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5Width-20”Depth-5.81”Type AQService Information:1P, 3W-120/240 Vac3P, 3W-240 Vac3P, 4W-240/120 Vac, 208/120 VacFully Rated: 65kAIC at 240VSeries Rated: 200kAIC at 240VMainsBreakers:100A-THQB, THHQB, TEY, SE, FE225A-TQD, THQD, SF, FE400A-TJD, SG, FG600A-SG800A-SKMain Lug:125-800ABranch Breakers (Bolt-on):Amperage-15-100APoles-1, 2, 3Types-THQB, THHQB, TXQBEnclosuresLength-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5Width-20”Depth-5.81”11-4BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

PanelboardsA-Series Section 11PanelboardsTypesType AE (includes subtype AS)Service Information:1P, 3W-120/240 Vac, 125/250 Vdc3P, 3W-240 Vac3P, 4W-480/277 Vac, 208/120 Vac, 240/120 VacFully Rated: 65kAIC at 480Y/277V, 100kAIC at 240VSeries Rated: 100kAIC at 480VMainsBreakers:100A-TEY, SE, FE225A-TFJ, SF, FE400A-TJJ, SG, FG600A-SG800A-SKMain Lug:125-800ABranch Breakers (Bolt-on):Amperage-15-100APoles-1, 2, 3Types-TEY, TEYF, TEYD, TEYH, TEYLAmperage-110A, 125APoles-2, 3Types-TEYD, TEYH, TEYLEnclosuresLength-25.5, 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5Width-20”Depth-5.81”Note: Bold items are features of AS PanelsType ADService Information:3P, 3W-480 Vac, 600 Vac3P, 4W-208/120 Vac, 480/277 Vac, 600/347 VacFully Rated: 35kAIC at 600Y/347V, 100kAIC at 480VSeries Rated: 35kAIC at 600Y/347VMainsBreakers:150A-THED, SE225A-TFJ, SF400A-TJJ, SG600A-SG800A-SKMain Lug:150-800ABranch Breakers (Bolt-on):Amperage-15-100A (1P, 2P)15-150A (3P)220A Max. double branchTypes-TED, SE, FBEnclosuresLength-31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5, 82.5, 88.5Width-20”Depth-5.81”Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog11-5

PanelboardsA-Series Section 11PanelboardsTypesPanelboard TypesA-SeriesALCPage 11-9AQCPage 11-9600Vac480Y/277Vac240Vac240VacAQPage 11-4240Vac240VacMax. Main LugAmperes800A800A800A800A400A225AMax. Main Breakeror Switch Amperes800A800A800A800A400A225ATEY, TFJ, TJJ, TEYF,TEYD, TEYH, TEYLTHED, TFJ, TJJTEY, SE, TFJ,SF, TJJ,SGMax.VoltageTHQB, THHQB, TQD, THQD,TEY, TJD, TFJMain DevicesAE/ASPage 11-5AD/AD PlusPage 11-5ALPage 11-4Item480Y/277Vac1125/250VdcSE, SF, SG, SKBranchesMax. Amps100A-1 ph, 2ph100A100A125ATHQL, THHQLTHQB,THHQB,TXQB(Bolt-on)TEY. TEYF, TEYD5,TEYH5, TEYL5SubfeedsMax. Amps(100% Rated)225225SubfeedBreaker TypesTQD, THQDTQD, THQDBranchDevicesDistribution PanelsColumn Type PanelsLightingControl PanelPage 11-11AECPage 11-9SpectraPage 225A225A1200ATEY, TFJ,SE, SFSF, SG, SK,ADS Switches,FB, FC, FE, FGTHQB, THHQB, TQD,THQD, TEY, TFJ,SE, SF80A-8 1/2 Box100A100A100AFB,TED,THED, SETEYRC, TEY,THQBGFTHQL,THHQLTHQB,THHQB,TXQB(Bolt on)TEYTED, SE, SF, SG, SK,THQB, THHQB, TEY,TQD, ADS Switches,FB, FC, FE, FG225225225150150150—TED, TFJ, SE, SFTED, TFJ, SE, SFTED, TFJ, SE, SFTQD, THQDTQD, THQDTED—150A-3 ph1200A80A-7 1/2 BoxA-Series Standard Main Breaker Types and RatingsPanel TypeAQ/ALAE / Lighting Control J4SGHA/TJJ4SGHA6AD / AD GHA6SGHA618SKHA8SEHA4/TEYD SFHA42565480Y/277100480Y/277142480SELA4/TEYL ASFLASGHA4SGHA6SEPASFPASGPA4SGPA635k2600Y/3471 AE Panels are suitable for use on 3-PH, 3W applications when derived from 3PH, 4W 480V/277 serviceSKHA6where the neutral is not connected to the panel. For 3ph-Delta use AD Panels.2 Not series rated.3 Not available in column panelboards.4 Light Control Panel ratings.5For installation in AS panels only.11-6BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

PanelboardsSection 11A-Series PanelboardsTerminal LugsMolded Case Circuit BreakersCircuit Breaker erminal Lugs (Cu-Al)Tri-Break ———1,2,3No. PerPoleWire—Cu-Al (Unless otherwise noted)Per LugRangeProductNumber11Fixed toBreaker Terminal(15-30A) #14-4 Cu or #12-4 Al(35-100A) #14-1/0 Cu or #12-1/0 LK12FCALK13FCALK14TCAL181(15-25A) #14-#12 Cu or #12-#10 Al(30-60A) #10-#6 Cu or #8-#4 Al(70-100A) #4-#1 Cu or #2-1/0 Al(15-30A, TCAL14)–#14-8(30-60A, TCAL12)–#14-3 Cu, #12-1 Al(70-90A, TCAL12A)–#6-2/0 Cu, #4-2/0 Al(100-150A, TCAL15)–#3-3/0(15-20A) #14-#12 Cu or #10-#12 Al(35-60A) #10-#6 Cu or #8-#4 Al(70-100A) #4-#1 Cu or #2-1/0 Al(15-20A) #14-#12 Cu or #10-#12 Al(35-60A) #10-#6 Cu or #8-#4 Al(70-100A) #4-#1 Cu or #2-1/0 Al#12-3/0 Cu, #12-3/0 Al1FCALK151#12-3/0 Cu, #14-1/0 1———FBV FBNFBH FBL—1,2,31———FCS FCV FCNFCH CALK151#12-3/0 Cu, #14-1/0 Al———2-32-32-3111TCAL25TCAL29TCAL24, 161#8-250kcmil Cu, #8-250kcmil—2-31FCALK161#8-250kcmil Cu, #8-250kcmil————TQDSFHATFJ, GDASGHASELA SEPAFES1T FEV1TFEN1T FEH1T FEL1TFES1E FEV1EFEN1E FEH1E FEL1E—SFLA SFPA—FES2T FEV2TFEN2T FEH2T FEL2TFES2E FEV2EFEN2E FEH2E FEL2ESGLSGPSGLSGPFGV2FGN2 FGH2FGL2 FGP2FGV4FGN4 FGH4FGL4 FGP4FGV6FGN6 FGH6FGL6 ��————TJJ, TJK4TJDTHJK4—TB4—TJK6THJK6, HA12,TKM124—12-31—Load End—SKLA12,SKPA12Load ne-pole THED frame available only in 15-30 amp trip.2Lug kit—includes line or load end cover.11—2(2/0-400kcmil Cu) or2(2/0-500kcmil Al) or #6-600kcmil2(2/0-400kcmil Cu) or2(2/0-500kcmil Al) or #6-600kcmilTop hole #8-400kcmil Cu or#6-500kcmil AlBottom hole #2/0-600kcmil Cu & AlTop hole #8-400kcmil Cu or#6-500kcmil AlBottom hole #2/0-600kcmil Cu & AlTop hole #8-400kcmil Cu or#6-500kcmil AlBottom hole #2/0-600kcmil Cu & Al#6-600kcmil or 2-(2/0-250kcmil)#6-600kcmil or 2-(2/0-250kcmil)#6-600kcmil or 2-(2/0-250kcmil)250-350kcmil, Cu, or 350-500kcmil, Al2/0-500kcmil#4-600kcmil or il3/0-500kcmil3/0-500kcmil250-350kcmil Cu or 350-5000kcmil Al250-350kcmil Cu or 350-500kcmil Al(15-60A, TCAL12)#14-#3 Cu or #12-#1 Al(70-100A, TCAL12A)#6-2/0 Cu or #4-2/0 Al(100-150A, TCAL15)#3-3/0 Cu or #1-3/0 Al(125-225A, TCAL27)#4-300kcmil3/0-500kcmil or 2-(3/0-250kcmil)3Three-pole lug assembly suitable for line or load end.4For replacement use only.ADS Fusible Switch Module Terminations (CU/AL Mechanical)5Amp RatingVoltageWire Size (CU/AL)# Wires Per Lug# Lugs Per 0I/O-250kcmil or #2-600kcmil2 or 11600240/600I/O-250kcmil or #2-600kcmil2 or 11800600I/O-250kcmil or #2-600kcmil2 or 111200600I/O-250kcmil or #2-600kcmil2 or 115 For optional mechanical or compression lugs refer to GET-7006.Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog11-7

PanelboardsSection 11A-Series PanelboardsPricing and OrderingInformation Required to Price and Order a PanelboardHow to Price Factory Assembled Panelboards—Short-circuit Rating (10kA, 18kA, etc.)Main Price (or Interior Price for A-Series ) Branch Circuits Options Total List of Panelboard. The sum of these list prices isthe total list for the complete panelboard including box and front.—Service Entrance Label (Yes) or (No)—Mark(s) (LPA, MDP, RPC, etc.)Please refer to Speedi for quoting, pricing and ordering GE panels—Service (3-ph, 4-w 208Y/120; 3-ph, 3-w 480 volts, etc.)—Entrance of Incoming Line (Top) or (Bottom).(Bottom Supplied as Standard)How to Lay Out Factory Assembled Panelboards—Incoming Wire Size (500kcmil, 250kcmil, etc.)—Multi-section panels must have a main circuit breaker or mainlugs in each section. Double (dual) main lugs or thru-feed lugsmust be added as required in all but the last section.—Incoming Number of Wires per phase (1, 2, 3, etc.)Please refer to Speedi for quoting, pricing and ordering GE panels—Trim (Surface) or (Flush)—Wire Material (Copper or Aluminum)—Main Type (Main Lugs Only, Circuit Breaker, Fusible Switch, etc.)How to select a Pro-Stock, unassembled panelboard—Amperage of Main BusTotal the following components:—Interior—Frame of Main Circuit Breaker (SG, SK, TJK, etc.) (if applicable)—Options to Mains (Shunt Trip, Lighting Contactor, etc.)—Equipment Ground (Optional)—Branches– Amp Rating (20, 30, 50, etc.)– Poles (1, 2, or 3)– Frame (THQB, TED, etc.)– Quantity (1, 10, 15, etc.)—Options:– Interior (Copper bus, 200% rated neutral, etc.)– Box (Painted, Increased Gutter, etc.)– Front (Door in Door, etc.)– Ground Fault Protection (Yes) or (No)—Box (add ground bars as required)—Front—Main breaker or lug kit—Subfeed breaker or feed thru lug kit (if required)—Branch Breakers (from Section 3)—Accessories (200% neutral, service entrance etc.)Please consult your local distributor for net pricing and currentstock levels.For additional details on selecting Pro-Stock panelboards, pleaserefer to publication DEP-104.—Type of Panel (AQ, AE, Spectra Bolt-on, etc.)11-8BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

PanelboardsSection 11A-Series PanelboardsColumn PanelsType ALCType AECService Information:1P, 3W-120/240 Vac3P, 4W–208/120 Vac, 480/277 Vac3P, 4W-240 VacService Information:3P, 4W-480/277 VacMainsBreakers:100A-THQB, THHQB, TEY, SE225A-TQD, THQD, SFMain Lug:125-225ABranch Breakers (Plug-in):Amperage-15-100A (1P, 2P, 3P)Types-THQL, THHQL, TXQLEnclosuresLength-37.5, 43.5, 49.5, 55.5, 64.5, EY, SE225A-TFJ, SFMain Lug:125-225ABranch Breakers (Bolt-on):Amperage-15-80A (1P, 2P, 3P)Types-TEYEnclosuresLength-37.5, 43.5, 49.5, 55.5, 64.5, 76.5Width-8.62”Depth-5.81”Type AQCService Information:1P, 3W-240/120 Vac3P, 3W-240 Vac3P, 4W-240 VacMainsBreakers:100A-THQB, THHQB, TEY, SE225A-TQD, THQD, SFMain Lug:125-225ABranch Breakers (Bolt-on):Amperage-15-100A (1P, 2P, 3P)Types-THQB, THHQB, TXQBEnclosuresLength-37.5, 43.5, 49.5, 55.5, 64.5, 76.5Width-8.62”Depth-5.81”Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog11-9

PanelboardsSection 11A-Series PanelboardsColumnField Installed Kits/Replacement PartsMiscellaneous KitsPanelboards PartsOrder by Product Number from the National Service CenterOrder from FactoryProductNumberDescriptionEquipment Grounds:DescriptionProduct NumberDirectory Card139C5612P2Circuit NumberingStandard Terminal StripWith Provision for(11) 14-8 Cu or 12-8 Al(3) 14-4 Cu or 6-4 AlTGL2Above terminal with Copper StrapTGC2Strips - 1-48Main Lug 6-2/0 Cu/AlTGL20Standard Isolated Insulated(11) 14-8 Cu or 12-8 Al(3) 14-4 Cu or 6-4 AlEGS12Above terminal with Copper StrapEGC1243-84Directory Card Holder569B806G1569B806G2139C5491P4Permanent Circuit Number KitsOrder from FactoryHandle Locking Devices:THQL, THHQL THQB, THHQBTHL103TEYTEYLD1TEDTLD3TFJ, TFL, TLB4TFKLD1Product NumberDescriptionAPN48No's 1-48APN84No's 43-84Padlocking Devices:THQL, THHQL, TXQLTHQB, THHQB, TXQB1THP100TEYTEYPLD1TED, TELTEFPLD1TQDTQDPLD1TFJ, TFLTFKPLD1Filler Plate for Q Lineand TEY BreakersTQLFP1Gasketing KitAGSKSafety Catch for Trough Covers 1ACHKStandard on pull box.11-10BuyLog Catalogwww.geindustrial.comRev. 11/13Data subject to changewithout notice

PanelboardsSection 11A-Series PanelboardsLighting Control Panel480Y/277 Vac/120/208 VacRemote Operated Circuit BreakersBolt-On Factory AssembledThree-Phase, 4-Wire PricingService Information:1P, 3W-120/240 Vac3P, 4W-208/120 Vac, 480/277 VacMainsBreakers:100A-TEY, SE225A-TFJ, SF400A-TJJ, SGMain Lug:125-400ABranch Breakers (Bolt-on):Amperage-15-30A (1P, 2P): TEYRC15-100A (1P, 2P, 3P): TEY220A Max. double branchTypes- TED, SE, FBEnclosuresLength-25.5 31.5, 37.5, 43.5, 49.5, 55.5, 64.5, 76.5Width-20”Depth-5.81”Rev. 11/13Data subject to changewithout noticewww.geindustrial.comBuyLog Catalog11-11

PanelboardsSection 11A-Series PanelboardsLighting Control Panel480Y/277 Vac/120/208 VacRemote Operated Circuit ing SoftwarePC-based start up softwareDaylight Optimization ModulePeforms sunlight harvesting by measuring theamount of light and provides a control signal to adimming mechanism to maintain a preset lighting level.Remote Switch Expansion ModuleProvides additional 16 digital inputsignals to the controller for each moduleControl Wiring Insulation TubingRequirement per UL67 and NEC725.55, that lowvoltage class

www.geindustrial.com Rev. 11/13 Data subject to change without notice 11-6 BuyLog Catalog Panelboards A-Series Panelboards Section 11 Panelboard Types A-Series Standard Main Breaker Types and Ratings Distribution Panels AL Page 11-4 Page 11-4 Page 11-5 Page