C -Safery Sensors and Controlsfor IndustryErgonomic PalmButtonsELight curtains with quickview diagnosticdisplays for increased productivity andmaximum operator safety.The safest and only "control reliable" p alm buttonthat can be used as a two-hand control device!Safety MatSystemsPressure-sensitive safety mats in any size, shape,cut or contour for your customized machineguarding application.Please visit www.pinnaclesystems.com for more information on other Pinnacle Systems products or fax yourrequest for a complete product catalog to: (412) 262-4055. Please be sure to include your company name,mailing address and a phone number with your request.

SLT SeriesInstallation and Operation ManualPinnacle Systems,Inc. 1510 Hubbard Ave.Batavia, IL 60510 USAPIN: 28-049r1-3Customer Service: 630-443-9320 (CST)(Please have Model#, Serial#, and Sotware Rev #Available)Sales and Marketing: 800-569-7697 (EST)www.pinnaclesystems.com sales@pinnaclesystems.com service@pinnaclesystems.com

Properu-a and LimitationsThe information disclosed herein includes propriet aryrights of the manufacturer. Neither this document nor theinformation disclosed herein shall be reproduced ortransferred to other document s, used or disclosed toothers for manufacturing purposes, or for any otherpurposes, except as specifically authorized in writing bythe manufacturer. If this manual is supplied in connectionwith the sale or delivery of manufacturer's equipment, itis to be used solely for maintenance, reiair, or installationof such equipment.The SLT Series was manufactured in the United States.The Installation Manual was printed in the United 3ates.You must read and fully underst and the followinginformation pertaining to the proper use and limiations ofyour Microguard:The SLT Series must be inst ailed by qualifiedpersonnel only.The SLT Series must NOT be used on fullrevolution presses or any machine that cannotbe commanded to stop at any time.You must NOT wire the Safety Output cont actsof the SLT Series to an external relay unless youuse the External Relay Checking feature.The mechanical power press on which the SL TSeries is installed must meet ANSI B11.1-1988and OSHA 1910.217 regulations. These includeinspection and maintenance procedures thatmust be followed to comply with the regulations.The manufacturer will NOTtake responsibility forimproperly maintained machinery.Point of operation safeguarding is defined ir:ANSIB11.19-2003. This regulation is used todetermine a safe dist ance to place your SL TSeries. The manufacturer takes no responsibilityfor injury as a result of improper safeguarding orimproper safe distances.The SLT Series may not be able to safely stop apress which has a faulty stopping mechanism.The manufacturer cannot be held responsible foran improperly maint ained or faulty stoppingmechanism.The SLT Series must be checked before put intooperation. Follow instructions provided in thismanual for procedures on how to do this.The SLT Series should never be modified orrepaired except by qualified personnel and uponauthorization of the manufacturer. Never operatemachinery that is not in full working order.Make sure that all maintenance people, machineoperators, die-setters, foreman, and supervisorshave read and understood this manual and allprocedures have been and will be followed.All procedures in this manual must be followed.The manufacturer cannot take responsibility foroperation if all procedures and warnings in thismanual are not followed.WarrantyManufacturer warrants that this product will be free fromdefects in material and workmanship for a period of twoyears from the date of shipment thereof. Within thewarranty period, the manufacturer will rep air or replace(at our discretion) any product that is disclosed as defectiveupon examination by the manufacturer and is returnedwith shipping charges prepaid.This warranty will not applyto any product that has been subjected to misuse,negligence, accident, restric tion, and use not inaccordance with manufacturer's instructions or which willhave been altered or repaired by persons other than theauthorized agent or employees of the manufacturer.DisclaimerThe provisions of the warranty are the sole obligations ofthe manufacturer and exclude all other warranties ofmerchantability, expressed or implied. Further, there areno warranties that extend beyond the above warrantyLimitation of LiabilityIn the event of any claim for breach of any obligations ofthe manufacturer under any order, whether expressed orimplied, and particularly in the event of any claim of abreach of the warranty or warranties cont ained in theparagraph "Warranty" or of any other warranties,expressed or implied which might despite the paragraphentitled "Disclaimer," be determined to be incorporated inany order, the company shall under no circumstances beliable for any consequential or special damages, either inlaw or in equity, or for losses or expenses or claims for thesame arising from the use of, or inability to use, theproducts of the manufacturer for any purpose whcBoever.We have designed our equipment to the very highestperformance and safety standards known to the currenttechnological state of the art. However, the installation,usage, suitability, and fitness of our equipment for anypurpose, known or unknown, is interdependent upon theperformance of other equipment not manufac tured,installed, or secured or maintained by the manufacturer.We cannot and do not accept responsibility for any overallsystem performance when factors, such as these, arebeyond our control.WARNING: The entire machine safety system mustbe tested at the start of every shift. Machine testingshould inclu de: ( 1) proper machine operation andstopping capability; and (2) verification of properinstallation and settings of all point of operation guardsand devices before the operation is released forproduction.

We will not supply individual component p arts of anycircuit board but will supply the individual circuit boardcomplete. Individual detectors or emitters are ava ilableas a complete tested unit.Fill this Information out Immediately(It will be needed in the event you need assistance)Purchase Date:-------------Purchased From:Model No.:---------------Serial No.:---------------Options:Microprocessor Revision No.:

Table of ContentsOverviewIntroduction . 1Theory of Operation . 1Specifications . 2Setup and Inst all ationInstallation Procedure . 3Wiring Diagram . 4Dimensional Inform ationPylons . 5Optional FeaturesAuto Blank . 6Auxiliary Output Contact . 6Cincinnati Interface . 6External Relay Check . 7Floating Blank . 7Latching Relays . 7AccessoriesCornering Mirrors . 8Pedestal Mounts (Model 8000) . 8Swing-Arm Mounting Bracket (Model 9000) . 9Diagnostics and TroubleshootingDiagnostics Indicator Lights . 10Troubleshooting . 10Diagnostic Display Codes . 12Appendix AANSI Standard B11.19-2003 . A-1Light Curtain Testing Procedure . A-2Safeguarding with Mechanical Guards . A-3OSHA Regulations . A-4Machine Control Reliability Requirements . A-5Safety Guidelines for Management . A-5- I -

OverviewSLTSeriesIntroductionThe SLT Series system is a dual redundant digit alinfrared point of operation guarding device which willprovide a signal to stop the machine when there is entryinto the guarded area. The system uses invisible infraredlight to detect obstructions protruding through theguarded area. The use of infrared light provides anunobstructed view of the work area and also makes theSLT Series system insensitive to almost all ambient lightconditions.The dual redundant system basical ly incorporates twomic roprocessors, four watchdog timers , and twoseparate captive contact relays to assure fail-safeoperation. If either microprocessor detects a failure inthe system or the other microprocessor , the workingmicroprocessor can shut down the unit. The watchdogtimers assures that if the oscillator on eithermicroprocessor is not running correctly , they can shutthe system down. The special force-guided contactrelays* allow self-checking software to detect a faultyrelay and shut down the unit with the redundant relay .The Diagnostics Display allows the user to betterunderstand the current condition of the light curtain. If afault is discovered by the light curtain, it will be displayed.The display is also used when options like the FloatingBlank or Auto Blank are being used. A brief descriptionof each follows:The Floating Blank option allows work pieces(designated by dimensions) to move throughoutthe guarded area without shutting the machinedown but entry into the protected area by theoperator will still provide a signal to stop themachine. The Floating Blank option does not needto be adjusted for various positions or die heightchanges, only adjusted for the size of the workpiece. Up to three beams at a time are allowedto be obstructed when the Floating Blank optionis in use.The Auto Blank option allows work pieces or fixedobjects to penetrate the guarded area withoutshutting the machine down. The size and locationof the object(s) is automatically programmed intothe computer with a turn of a key, so you do notneed to know the size of the object to programthe unit. Auto Blank must be reprogrammed whenthere is a loss of power. Up to eight beams at atime are allowed to be obstructed when the AutoBlanking option is in use. Force-Guided Contact Relays are mechanically linked togethe rto force both poles to maintain the same position regardless ofwhether the relay is energized or de-energized. This allows awelded contact to be detected by monitoring the other pole.The SLT Series system operates from two pylons. Powermust be supplied separately to both pylons usingstandard wiring procedures. The interface or stop circuitinterconnection is made from the Receiver Pylon.The SL T Series system can only be used on p artrevolution or clutched machines which can be signaledto stop at any part of their cycle by opening an electricalcircuit.Theory of OperationThe SLT Series system is an infrared light curt ainconsisting of two pylons that talk to each other via aninfrared channel called the Sync Channel. The ReceiverPylon transmits to the Emitter Pylon for the purpose ofsynchronizing the two units eliminating the need for athird box with a cable connecting the pylons together .The status of the Sync Channel can be determined bythe Diagnostics Display on the Receiver Pylon whichwill show flashing decimal points to indicate that theEmitter Pylon is not firing.The Receiver Pylon is the controller and the EmitterPylon is slaved to it by the Sync Channel. The internallogic of the Receiver Pylon controls the scanningfunction, the detection, the output control, and theinternal diagnostic functions.When the two pylons are synchronized, the Emitter Pylonbegins to scan from the top down with its infraredemitters called "data channels" or otherwise known asinfrared beams. The Emitter Pylon's beams are scannedmany thousands of times a second and, each time abeam is selected, its infrared emitter is pulsed. Thissequential scan of infrared pulses is picked up by theReceiver Pylon which is synchronized to the scanningEmitter Pylon and recorded. If a beam is blocked by anobstruction, the control logic drops out the Output Relaysand turns on the RED indicator.The Internal Diagnostic Logic runs at the same frequencyas the scan frequency so all operational componentsand timings are checked many thousands of times asecond to insure Fail-Safe operation. The control logicin this unit has no lock-up or failed mode except for hardinternal failures. No matter what conditions prevail, theunit is trying to keep all systems operational.

OverviewSLT SeriesSpecificationaEmitter and Receiver PylonsInput Power:120VAC /- 10% VAC@ 50-60 Hz, 12 watts max/pylon24VDC(optional)Output Circuit:Safety RelaysTwo force-guided self-checking N.O. relays in series rated at4 AMPS@120VACIsolated (DRY) Normally Open contacts. --11--11-130VAC maximumAuxiliary RelayN.O. or N.C.Solid State OutputTwo PNP outputs rated at 500mA each. The solid state outputs mustnever be placed in series or parallel and are not to be used as the finalswitching element(s).Fuses:External Indicators:Receiver PylonEmitter PylonConstructionPower: Surface mount replaceable 1A Slow Blow1) GREEN Output Relay contacts closed (OK)2) RED Output Relay contacts open (NOT OK)3) Diagnostics Display (single dig it alphanumeric)RED Sync channel alignment indicator(11-1/2" down, viewable only from inside unit)Aluminum extrusion with steel end caps, m ounting brackets, and replaceablepoly cargonate lens. NEMA 4 (without blanking keyswitch).Temperature Range:32 to 1200 FDimensions:See Dimensional InformationBeam Spacing:3/4" (19mm)Minimum SensitivityWithout Blankin1:1:1-1/4" (32mm)Response Time: 30 milliseconds (all lengths)Scanning Frequency:3.6 Khz2

Setup and InstallationSLTSerieslnstallatlon ProcedureCaution: Pylons should be mounted in a mannerso that ony authorized personnel can change themounting or location.10) Mechanical guarding may also be required fromreaching around the light curtain to the point ofoperation (see Table 0-10, Appendix A).Caution: Additional guards may be required toprevent the operator from standing between thelight curtain and the point of operation.11) F o r ins tallation assis tance, please callmanufacturer's service dei:artment at (800) 8512026.12) Refer to the Light Curain Test Procedure section(Page AA-2) to ensure the light curt ain isfunctioning properly.1) Locate pylons so the working zone is guardedfrom reaching around, over, and under the SLTSeries system to the point of operation or hazardzone. Mounting of pylons should be shockmounted (see Safeguarding with MechanicalGuards, Appendix A).Wiring ColorEmitter and Receiver PylonsNOTE: For location of pylons in relation to thehazard area, refer to Federal Register 1910.217(c) (3) (iii) (e) andTable 0-10 (both are availablein Appendix A).Black (Pin #1): 120VAC Line (or 24 VDC for DCmodels)White (Pin #2): 120VAC Neutral (or ground for DCmodels)2) Determine the safety distance of the light curtainfrom the point of operation using the ANSIStandard B11.19-2003 (see Appendix A).Green (Pin #7): Earth GroundReceiver Pylon3) Refer to Dimensional Information for mechanicallayout of the pylons.Red (Pin #4):4) Refer to the Wiring Diagram and Wiring Colorsections for electrical connections.Safety Relay Output 1(N.O. open when blocked)Red/Black (Pin #5):Safety Relay Output 1(or solid state out 1, 24VDCwhen green)Blue (Pine #9):Safety Relay Output 2(N.O. open when blocked)Blue/Black (Pin #10):Safety Relay Output 2(or solid state out 2, 24VDCwhen green)Black/White (Pin #11):Auxiliary Output(N.O. open when blocked)5) Power is brought to both pylons 120V AC @60Hz. The Ground Terminal must be connectedto a good ground connection, not conduit. Abad ground may keep the light curtain fromgoing GREEN in an el ectricall y noisyenvironment.6) Align the light curtain. If you have a keyswitch,turn it to OFF or its lowest setting.No communication between pylons: Displaywill show a 1 with flashing decimal points.White/Black (Pin #12): Auxiliary output(common)Communication but RED light: Display showsa 1 with no decimal points.Green/Black (Pin #13): Auxiliary output(N.C. closed when blocked)Green light: Display shows a 0.If a GREEN light cannot be a ch ieved duringalignm ent,see Diagnos tics andTroubleshooting).Orange (Pin #15):Orange/Black (Pin #16): Cincinnati Interface Input( 24VDC to force blockage,ground for normal operation)7) Interface the light curtain standard relay outputcontacts to the safety stop circuit.Caution: Solid state outputs must only be usedto drive a solid state input device such as a safetyPLC and not a relay or solenoid. Solid stateoutputs are monitored for safety and cannot beput in parallel with any other device; doing so willcause a fault in the SLT Series system.8) Interface any remaining optional input or outputlines to their proper terminals (see Featuressection).9) Check and assure stop of machine when signalof penetration is made anywhere in the curaiin'sfield of view.Remote latching reset3

Setup and InstallationSLTSeriesWiring DiagramImportant: T he Gr oundTerminal must be connectedto a good ground connection,not conduit. A bad groundmay keep the light cur tainfrom going GREEN in ane lectrically noisy environment. - Li ne ( 24VDC)Mechanical Safety Relay Outputs120VAC or 24VDC Input PowerNeutral (-24VDC) .l]ReceiverCableIn ser ieswith Stop I Circuit1 0r-,., J 11 Q - Auxil iary N.O.11.(J 13Auxiliary Common0 - Auxil iary N.C.r--.Optional\JLatching Reset1Q Q /- 24VDC- 160 0- Cincinnati Interface Input 24VDC RedGr ound GuardedExternal Relay Check Input --II--\\- 24External N.O. monitored contactsSolid State Output Onl y24VDC Input Power-24VDCEarth#1ReceiverCable#2724VDC out w