Service Instructions - Dominion Energy

Transcription

ServiceInstructions80%, 90%, 95% Gas Furnaces& AccessoriesACS, ACV, ADS, ADV, AMH, AMS, AMV, DCS, DDS,DHS, DMS, GCH, GCS, GDH, GDS, GCV, GHS, GKS,GME, GMH, GMS, GMVThis manual is to be used by qualified, professionally trained HVAC technicians only. Goodman doesnot assume any responsibility for property damage or personal injury due to improper serviceprocedures or services performed by an unqualified person.Copyright 2006-2007 Goodman Manufacturing Company, L.P.www.goodmanmfg.comwww.amana-hac.comRS6610004 Rev. 2November 2007

TABLE OF CONTENTSIMPORTANT INFORMATION . 2-3POLARIZATION & PHASING . 92PRODUCT IDENTIFICATION . 4-14MAINTENANCE . 93-95OPERATING INSTRUCTIONS . 20-22SERVICING .96-128ACCESSORIES . 23-27TROUBLESHOOTING . 105-106PRODUCT DESIGN . 28-79SERVICING TABLE OF CONTENTS . 98SYSTEM OPERATION . 80-91ACCESSORIES WIRING DIAGRAMS . 129-131IMPORTANT INFORMATIONPride and workmanship go into every product to provide our customers with quality products. It is possible, however,that during its lifetime a product may require service. Products should be serviced only by a qualified service technicianwho is familiar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testinginstruments and the appropriate service manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATESERVICE MANUAL BEFORE BEGINNING REPAIRS.IMPORTANT NOTICES FOR CONSUMERS AND SERVICERSRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELSWARNINGTO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONALINJURY, OR DEATH,DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHERFLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.WARNINGG OODMAN WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES.I F YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICHMAY RESULT. M ANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND AIR CONDITIONING EQUIPMENT.WARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORINSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAYBE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTYDAMAGE, PERSONAL INJURY OR DEATH.2

IMPORTANT INFORMATIONSpecial Warning for Installation of Furnace or Air Handling Units inEnclosed Areas such as Garages, Utility Rooms or Parking AreasCarbon monoxide producing devices (such as an automobile, spaceheater, gas water heater, etc.) should not be operated in enclosed areassuch as unventilated garages, utility rooms or parking areas because ofthe danger of carbon monoxide (CO) poisoning resulting from the exhaustemissions. If a furnace or air handler is installed in an enclosed area suchas a garage, utility room or parking area and a carbon monoxide producingdevice is operated therein, there must be adequate, direct outsideventilation.This ventilation is necessary to avoid the danger of CO poisoning whichcan occur if a carbon monoxide producing device continues to operate inthe enclosed area. Carbon monoxide emissions can be (re)circulatedthroughout the structure if the furnace or air handler is operating in anymode.CO can cause serious illness including permanent brain damage or death.To locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased thisproduct. For further assistance, please contact:CONSUMER INFORMATION LINEGOODMAN BRAND PRODUCTSTOLL FREE1-877-254-4729 (U.S. only)email us at:customerservice@goodmanmfg.comfax us at: (731) 863-2382(Not a technical assistance line for dealers.)CONSUMER INFORMATION LINEAMANA BRAND PRODUCTSTOLL FREE1-877-254-4729 (U.S. only)email us at:hac.consumer.affairs@amanahvac.comfax us at: (931) 438-4362(Not a technical assistance line for dealers.)Outside the U.S., call 1-713-861-2500.(Not a technical assistance line for dealers.)Your telephone company will bill you for the call.Outside the U.S., call 1-931-433-6101.(Not a technical assistance line for dealers.)Your telephone company will bill you for the call.3

PRODUCT IDENTIFICATIONThe model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use these numbers when requesting service or parts information.GMS9070 3 BXAAMinorRevisionProduct TypeA: Amana BrandD: Amana Distinctions TM BrandG: GoodmanA: InitialReleaseMajorRevisionSupply TypeA: InitialReleaseM: Upflow/HorizontalD: Dedicated DownflowC: Downflow/HorizontalH: High Air FlowAdditional FeaturesN: Natural GasX: Low NOxFurnace TypeE: Two Stage/X-13 MotorS: Single Stage/Multi-speedV: Two Stage/Variable-speedH: Two Stage/Multi-speedCabinet WidthA: 14"B: 17 1/2"C: 21"D: 24 1/2"AFUE8: 80%9: 90%95: 95%Airflow Capability@ 0.5" ESP3: 1200 CFM4: 1600 CFMNominal Input045:45,000 Btuh070:70,000 Btuh090:90,000 Btuh115: 115,000 Btuh140: 140,000 Btuh45: 2000 CFM

PRODUCT IDENTIFICATIONMODEL #MFG. #80 % GAS FURNACESADS8*ADS8*****AAAmana Brand 80% Gas Furnace, 39" tall, Dedicated Downflow, Induced Draft, 39" 80% furnace redesignchanges that include new two tone grey painted cabinet and front panels, PSC motor, standardized blowerdecks, and a Surestart Silicon Nitride Igniter. Left or right gas pipe entry.The furnaces also feature an integratedelectronic ignition control and a Million-Air stainless steel tubular heat exchanger. Chassis sizes are now 14",17.5", 21" wide.ADV8*ADV8******AAAmana Brand 80% Variable Speed Gas Furnace - 2 stage heat gas furnace, 39" tall, Dedicated Downflow,2-Stage Induced Draft, new two tone grey painted cabinet and front panels, standardized blower decks and aSurestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control and Million-Air stainless steel tubular heat exchanger. Chassis sizes are now 17.5", 21" wide.ADV8*****BAADV8*****BAADV8*****BBAmana Brand 80% Variable Speed Gas Furnace - 2 stage heat gas furnace, 39" tall, Dedicated Downflow,2-Stage Induced Draft, new two tone grey painted cabinet and front panels, standardized blower decks and aSurestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control,120 volt silicon nitride igniter and Million-Air stainless steel tubular heat exchanger. Chassissizes are now 17.5", 21" wide. BB models utilized the round nose inducer motor.AMH8*****AAAMH8*****ABAMH8*****ACAmana Brand 80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, Induced Draft, new grey paintedcabinet and front panels, PSC motor, standardized blower decks and a 120V silicon nitride igniter. Left or rightgas pipe entry. The furnaces also feature an integrated electronic ignition control and aluminized steel tubularheat exchanger. Chassis sizes are now 14", 17.5" 21, and 24.5" wide. ***AB Models used a round noseinducer motor. ***AC models revert back to Jakel square nose inducer.AMS8*****AAAmana Brand Gas Furnace, 39" tall, Upflow/Horizontal Right or Left, Induced Draft, furnace redesignchanges that include new two tone grey painted cabinet and front panels, PSC motor, standardized blowerdecks and a Surestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integratedelectronic ignition control and a Million-Air stainless steel tubular heat exchanger. Chassis sizes are now 14",17.5", 21" and 24.5" wide.AMV8*****AAAmana Brand 80% Variable Speed Gas Furnace - 2 stage heat gas furnace, 39" tall, Upflow/Horizontal Leftor Right, 2-Stage Induced Draft, new two tone grey painted cabinet and front panels, standardized blower decksand a Surestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integratedelectronic ignition control and Million-Air stainless steel tubular heat exchanger. Chassis sizes are now 17.5",21" wide.AMV8*****BAAMV8*****BAAMV8*****BBAmana Brand 80% Variable Speed Gas Furnace - 2 stage heat gas furnace, 39" tall, Dedicated Downflow,2-Stage Induced Draft, new two tone grey painted cabinet and front panels, standardized blower decks and aSurestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control,120 volt silicon nitride igniter and Million-Air stainless steel tubular heat exchanger. Chassissizes are now 17.5", 21" wide. BB models used the round nose inducer motor.DDS8******AAAmana Distinctions Brand 80% Gas Furnace, 39" tall, Dedicated Downflow, Induced Draft, furnaceredesign changes that include new two tone grey painted cabinet and front panels, PSC motor, standardizedblower decks and a Carbide Mini-Igniter. Left or right gas pipe entry. The furnaces also feature an integratedelectronic ignition control and aluminized steel tubular heat exchanger. Chassis sizes are now 14", 17.5" and21" wide.DHS8******AAAmana Distinctions Brand 80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, (High Air Flowdesign), Induced Draft, furnace design changes that include new two tone grey painted cabinet and frontpanels, PSC motor, standardized blower decks and a Carbide Mini-Igniter. Left or right gas pipe entry. Thefurnaces also feature an integrated electronic ignition control and aluminized steel tubular heat exchanger.Chassis sizes are now 14", 17.5", 21" wide.DMS8*DMS8******AAAmana Distinctions Brand 80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, Induced Draft,furnace design changes that include new two tone grey painted cabinet and front panels, PSC motor,standardized blower decks and a Carbide Mini-Igniter. Left or right gas pipe entry. The furnaces also feature anintegrated electronic ignition control and aluminized steel tubular heat exchanger. Chassis sizes are now 14",17.5", 21" and 24.5" wide.GDH8*GDH8*****AAGDH8*****ABGDH8*****ACGoodman Brand 80% Gas Furnace, 39" tall, Dedicated Downflow, Induced Draft, new grey painted cabinetand front panels, PSC motor, standardized blower decks and a 120V Silicon Nitride igniter. Left or right gaspipe entry. The furnaces also feature an integrated electronic ignition control and aluminized steel tubular heatexchanger. Chassis sizes are now 14", 17.5" and 21" wide. ***AB Models used a round nose inducer motor.***AC models revert back to Jakel square nose *****BCGoodman Brand 80% Gas Furnace, 39" tall, Dedicated Downflow, 2-stage/multi-speed, Induced Draft,new grey painted cabinet and front panels, PSC motor, standardized blower decks and a Carbide Mini-Igniter.Left or right gas pipe entry. The furnaces also feature an integrated electronic ignition control and aluminizedsteel tubular heat exchanger. Chassis sizes are now 14", 17.5", 21" wide. ***BB Models used a round noseinducer motor. ***BC models revert back to Jakel square nose inducer.AMH8*AMS8*AMV8*DDS8*DHS8*5

PRODUCT IDENTIFICATION6MODEL #MFG. #80 % GAS *****BCGHS8*****BDGoodman Brand 80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, (High Air Flow Design),Induced Draft, new grey painted cabinet and front panels, PSC motor, standardized blower decks and aCarbide Mini-Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignitioncontrol and aluminized steel tubular heat exchanger. Chassis sizes are now 14", 17.5", 21" wide. ***BB Modelsused a round nose inducer motor. ***BC models revert back to Jakel square nose man Brand80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, Induced Draft, new grey paintedcabinet and front panels, X-13 motor, standardized blower decks and a 120V silicon nitride igniter. Left or rightgas pipe entry. The furnaces also feature an integrated electronic ignition control and aluminized steel tubularheat exchanger. Chassis sizes are now 17.5" and 21" wide. ***AB Models used a round nose inducer motor.***AC models revert back to Jakel square nose man Brand 80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, Induced Draft, new greypainted cabinet and front panels, PSC motor, standardized blower decks and a 120V silicon nitride igniter. Leftor right gas pipe entry. The furnaces also feature an integrated electronic ignition control and aluminized steeltubular heat exchanger. Chassis sizes are now 14", 17.5" and 21" wide. ***AB Models used a round noseinducer motor. ***AC models revert back to Jakel square nose *****BCGMS8*****BDGoodman Brand 80% Gas Furnace, 39" tall, Upflow/Horizontal Left or Right, Induced Draft, new greypainted cabinet and front panels, PSC motor, standardized blower decks and a Carbide Mini-Igniter. Left orright gas pipe entry. The furnaces also feature an integrated electronic ignition control and aluminized steeltubular heat exchanger. Chassis sizes are now 14", 17.5", 21" and 24.5" wide. ***BB Models used a roundnose inducer motor. ***BC models revert back to Jakel square nose inducer.GMV8*GMV8*****AAGMV8*****BAGoodman Brand 80% Variable Speed - 2 stage heat Gas Furnace, 39" tall, Upflow/Horizontal Left or Right,2-stage Induced Draft, new grey painted cabinet and front panels, standardized blower decks and a 120VSilicon NitrideIgnitor. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignitioncontrol and aluminized steel tubular heat exchanger. Chassis sizes of 17.5", 21" wide.

PRODUCT IDENTIFICATIONMODEL #MFG. #DESCRIPTIONACS9*P1257001FthroughP1257006FAmana Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall, Induced Draft,new two tone grey painted cabinet and front panels, PSC motor, standardized blower decks and aSurestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature anintegrated electronic ignition control and a Million-Air stainless steel tubular heat exchanger. NOxCertified. Chassis sizes are now 17.5", 21" and 24.5" wide.P1257007FthroughP1257010FAmana Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall, Induced Draft,new two tone grey painted cabinet and front panels, PSC motor, standardized blower decks and aSurestart Silicon Nitride Igniter. Left or right gas pipe entry. The furnaces also feature anintegrated electronic ignition control and a Million-Air stainless steel tubular heat exchanger. NOxCertified. Chassis sizes are now 17.5", 21" and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates anew crimped designed blower housing and a new blower deck. The crimped blower housing willnot fit inside of the previous "P" numbers for this same model. Redesigned 90 drain elbow byadding a side drain port hole. The side port drain tube is only used when placing the furnace inthe horizontal left application.P1257703F,P1257705FAmana Brand 90% Variable Speed - 2 stage Gas Furnace, Downflow/Horizontal Left andRight, 40" tall, 2-stage Induced Draft, new two tone grey painted cabinet and front panels,standardized blower decks and a Surestart Silicon Nitride Igniter. Left or right gas pipe entry. Thefurnaces also feature an integrated electronic ignition control and a Million-Air stainless steeltubular heat exchanger. NOx Certified. Chassis sizes are now 21" and 24.5" wide.P1257707FAmana Brand 90% Variable Speed - 2 stage Gas Furnace, Downflow/Horizontal Left andRight, 40" tall, 2-stage Induced Draft, new two tone grey painted cabinet and front panels,standardized blower decks and a Surestart Silicon Nitride Igniter. Left or right gas pipe entry. Thefurnaces also feature an integrated electronic ignition control and a Million-Air stainless steeltubular heat exchanger. NOx Certified. Chassis sizes are now 21" and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates anew crimped designed blower housing and a new blower deck. The crimped blower housing willnot fit inside of the previous "P" numbers for this same model. We also have a new drain elbowwith a side drain port hole added. It is used when placing the furnace in the horizontal leftapplication.P1256601FP1256606FAmana Brand 90% Gas Furnace, Upflow/Horizontal Left and Right, 40" tall, Induced Draft, newtwo tone grey painted cabinet and front panels, standardized blower decks and a Surestart SiliconNitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassissizes are now 17.5", 21" and 24.5" wide.P1256607FthroughP1256610FAmana Brand 90% Gas Furnace, Upflow/Horizontal Left and Right, 40" tall, Induced Draft, newtwo tone grey painted cabinet and front panels, standardized blower decks and a Surestart SiliconNitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassissizes are now 17.5", 21" and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates anew crimped designed blower housing and a new blower deck. The crimped blower housing willnot fit inside of the previous "P" numbers for this same model. Redesigned 90 drain elbow byadding a side drain port hole. The side port drain tube is only used when placing the furnace inthe horizontal left application.ACS9*ACV9*ACV9*AMS9*AMS9*7

PRODUCT IDENTIFICATIONMODEL #MFG. #DESCRIPTIONAmana Brand 95% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft, newAMH95AMH95***AA two tone grey painted cabinet and front panels, standardized blower decks and a 120V SiliconAMH95***AB Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicAMH95***AC ignition control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassissizes are now 17.5", 21" and 24.5" wide. Two stage heat, single stage cooling.AMS95Amana Brand 95% Gas Furnace, Upflow/Horizontal Left and Right, 40" tall, Induced Draft, newtwo tone grey painted cabinet and front panels, standardized blower decks and a Surestart SiliconAMS95***AANitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicAMS95***ABignition control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassissizes are now 17.5", 21" and 24.5" 7406FAmana Brand 90% Variable Speed - 2 stage Gas Furnace, Upflow/Horizontal Left and Right,40" tall, 2-stage Induced Draft, furnace redesign changes that include new two tone grey paintedcabinet and front panels, standardized blower decks and a Surestart Silicon Nitride Igniter. Left orright gas pipe entry. The furnaces also feature an integrated electronic ignition control and aMillion-Air stainless steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21"and 24.5" wide.P1257407F,P1257408FAmana Brand 90% Variable Speed - 2 stage Gas Furnace, Upflow/Horizontal Left and Right,40" tall, 2-stage Induced Draft, furnace redesign changes that include new two tone grey paintedcabinet and front panels, standardized blower decks and a Surestart Silicon Nitride Igniter. Left orright gas pipe entry. The furnaces also feature an integrated electronic ignition control and aMillion-Air stainless steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21"and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates anew crimped designed blower housing and a new blower deck. The crimped blower housing willnot fit inside of the previous "P" numbers for this same model. Redesigned 90 drain elbow byadding a side drain port hole. The side port drain tube is only used when placing the furnace inthe horizontal left application.AMV9*8

PRODUCT IDENTIFICATIONMODEL #MFG. #DCS9*P1257102F,P1257104F,P1257106FAmana Distinctions Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall,Induced Draft, furnace design changes that include new two tone grey painted cabinet and frontpanels, PSC motor, standardized blower decks and a Carbide Mini-Igniter. Left or right gas pipeentry. The furnaces also feature an integrated electronic ignition control and aluminized steeltubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and 24.5" wide.P1257107FP1257108FAmana Distinctions Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall,Induced Draft, furnace design changes that include new two tone grey painted cabinet and frontpanels, PSC motor, standardized blower decks and a Carbide Mini-Igniter. Left or right gas pipeentry. The furnaces also feature an integrated electronic ignition control and aluminized steeltubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates anew crimped designed blower housing and a new blower deck. The crimped blower housing willnot fit inside of the previous "P" numbers for this same model. Redesigned 90 drain elbow byadding a side drain port hole. The side port drain tube is only used when placing the furnace inthe horizontal left application.P1256701F,P1256706FAmana Distinctions Brand 90% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall,Induced Draft, furnace design changes that include new two tone grey painted cabinet and frontpanels, PSC motor, standardized blower decks and a Carbide Mini-Igniter. Left or right gas pipeentry. The furnaces also feature an integrated electronic ignition control and aluminized steeltubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and 24.5" wide.P1256707FthroughP1256710FAmana Distinctions Brand 90% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall,Induced Draft, furnace design changes that include new two tone grey painted cabinet and frontpanels, PSC motor, standardized blower decks and a Carbide Mini-Igniter. Left or right gas pipeentry. The furnaces also feature an integrated electronic ignition control and aluminized steeltubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates anew crimped designed blower housing and a new blower deck. The crimped blower housing willnot fit inside of the previous "P" numbers for this same model. Redesigned 90 drain elbow byadding a side drain port hole. The side port drain tube is only used when placing the furnace inthe horizontal left application.DCS9*DMS9*DMS9*DESCRIPTION9

PRODUCT IDENTIFICATIONMODEL #MFG. 7206FGoodman Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall, Induced Draft,new grey painted cabinet and front panels, PSC motor, standardized blower decks and a CarbideMini-Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignitioncontrol and aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5",21" and 24.5" wide.P1257207FthroughP1257209FGoodman Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall, Induced Draft,new grey painted cabinet and front panels, PSC motor, standardized blower decks and a CarbideMini-Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignitioncontrol and aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5",21" and 24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates a newcrimped designed blower housing and a new blower deck. The crimped blower housing will not fitinside of the previous "P" numbers for this same model. Redesigned 90 drain elbow by adding aside drain port hole. The side port drain tube is only used when placing the furnace in the horizontalleft application.GCH9***AAGCH9***ABGoodman Brand 90% Gas Furnace, Downflow/Horizontal Left and Right, 40" tall, Induced Draft,new grey painted cabinet and front panels, PSC motor, standardized blower decks and a 120VSilicon Nitride igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control and aluminized steel tubular heat exchanger. NOx Certified. Chassis sie are now17.5", 21" and 24.5" wide. Two stage heat, single stage cooling.GCV9*P1257803F,P1257805FGoodman Brand 90% Variable Speed - 2 Stage Gas Furnace, 40" tall, Upflow/Horizontal Left orRight, Induced Draft, new grey painted cabinet and front panels, standardized blower decks and aCarbide Mini-Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronicignition control and aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now21" and 24.5" wide. (BA models use Surestat Silicon Nitride an Brand 92.1% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft,new grey painted cabinet and front panels, PSC motor, standardized blower decks and a CarbideMini-Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignitioncontrol and aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5",21" and 24.5" 806FGoodman Brand 90% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft, newgrey painted cabinet and front panels, PSC motor, standardized blower decks and a Carbide MiniIgniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignition controland aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and24.5" wide.P1256807FthroughP1256809FGoodman Brand 90% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft, newgrey painted cabinet and front panels, PSC motor, standardized blower decks and a Carbide MiniIgniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignition controland aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and24.5" wide.(Note: The "P" numbers to the left include the following design changes.) Incorporates a newcrimped designed blower housing and a new blower deck. The crimped blower housing will not fitinside of the previous "P" numbers for this same model. Redesigned 90 drain elbow by adding aside drain port hole. The side port drain tube is only used when placing the furnace in the horizontalleft application.GCS9*GCH9*GMS9*10GMS95*Goodman Brand 95% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft, newgrey painted cabinet and front panels, PSC motor, standardized blower decks and a Carbide MiniGMS9****AAIgniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignition controlGMS9****ABand aluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and24.5" wide.GMV9*Goodman Brand 90% Variable Speed - 2 stage heat Gas Furnace, Upflow/Horizontal Left orRight, 40" tall, 2-stage Induced Draft, new grey painted cabinet and front panels, standardizedP1257603F blower decks and a Carbide Mini-Igniter. Left or right gas pipe entry. The furnaces also feature anP1257607Fintegrated electronic ignition control and aluminized steel tubular heat exchanger. NOx Certified.Chassis sizes of 17.5", 21" and 24.5" wide.

PRODUCT IDENTIFICATIONMODEL #MFG. #DESCRIPTIONGMV9*Goodman Brand 90% Variable Speed - 2 stage heat Gas Furnace, Upflow/Horizontal Left orRight, 40" tall, 2-stage Induced Draft, new grey painted cabinet and front panels, standardizedblower decks and a Carbide Mini-Igniter. Left or right gas pipe entry. The furnaces also feature anintegrated electronic ignition control and aluminized steel tubular heat exchanger. NOx Certified.P1257610F - Chassis sizes of 17.5", 21" and 24.5" wide.P1257611F (Note: The "P" numbers to the left include the following design changes.) Incorporates a newcrimped designed blower housing and a new blower deck. The crimped blower housing will not fitinside of the previous "P" numbers for this same model. Redesigned 90 drain elbow by adding aside drain port hole. The side port drain tube is only used when placing the furnace in the horizontalleft application.GMH95*GMH95***AA two tone grey painted cabinet and front panels, standardized blower decks and a 120V SiliconGMH95***AB Nitride Igniter. Left or right gas pipe entry. The furnaces also feature an integrated electronic ignitionGMH95***AC control and a Million-Air stainless steel tubular heat exchanger. NOx Certified. Chassis sizes areGoodman Brand 95% Gas Furnace, Upflow/Horizontal Left or Right, 40" tall, Induced Draft, newnow 17.5", 21" and 24.5" wide. Two stage heat, single stage **BBGoodman Brand 95% Variable Speed - 2 stage Gas Furnace, Upflow/Horizontal Left or Right,40" tall, 2-stage Induced Draft, new grey painted cabinet and front panels, new standardized blowerdecks, new blower housing and a Carbide Mini-Igniter.(BA model has 120V Silicon Nitride igniters.)Left or right gas pipe entry. The furnaces also feature an integrated electronic ignition control andaluminized steel tubular heat exchanger. NOx Certified. Chassis sizes are now 17.5", 21" and 24.5"wide.11

PRODUCT IDENTIFICATIONMODEL #MFG #DESCRIPTIONFossil Fuel Kit. The AFE18-60A control is des

PRODUCT IDENTIFICATION 5 MODEL # MFG. # 80 % GAS FURNACES ADS8* ADS8*****AA Amana Brand 80% Gas Furnace, 39" tall, Dedicated Downflow, Induced Draft, 39" 80% furnace redesign changes that include new two tone grey painted cabinet and front panels, PSC motor, standardized blower