Rack Power Distribution & Rack Systems - Dell UPS

Transcription

Rack PowerDistribution &Rack SystemsWorldwide

IntroductionAPC by Schneider Electric offers a wide array ofstandardized Rack Power Distribution Units (PDUs)designed to increase manageability and efficiencyin your data center.TMTMBasic Rack PDUs reliable power distributionMetered Rack PDUs real-time remote monitoring of connected loads user-defined alarms warn IT and data centermanagers of potential circuit overloads to preventaccidental power loss to critical equipmentSwitched Rack PDUs metered functionality individual outlet control to power cycle outlets manage on/off equipment sequencingMetered-by-Outlet Rack PDUs provide greater power management individual outlet-level power metering user-resettable energy (kWh) logs for capacityplanning and energy-efficency initiativesAP8000 Series Rack PDUsThe AP8000 Series Rack PDU platform will help ITand facilities managers more effectively managepower capacity and functionality for critical network,server, and data center equipment. These Rack PDUssolve rack-level power needs while incorporatingintelligent features, such as real power measurementand environmental monitoring, all in a spaceefficient, zero-U form factor. AP8000 Series RackPDUs include active power metering and remotealarming with volts, amps, real power (kW), andenergy (kWh) measurements.Access the latest electronic version of thisbrochure at: www.apc.com/wp?br 423

Product Feature by Rack PDUby etered-byOutlet P7900SeriesAP8900SeriesAP8600Series * Outlet level grouping (multiple outlets in same or multiple unitsfollow single command) User access control with assignable roles, access levels atdevice and outlet level Outlet grouping feature for synchronized control of outlets onmultiple Rack PDUs Design FeaturesUltra-low-profile, space-saving designHydraulic-magnetic circuit breakers(in units configured with circuit breakers) Ultra-low-profile circuit breakers (for units with breakers)Locking IEC receptacles and locking power cord compatibleEnvironmental monitoring port for externaltemperature/humidity monitoringDisplay and Network ManagementFull-featured network management capability via Web, SNMP, TelnetTwo-digit, seven-segment LED displayUser-interactive LCD display for local accessField-replaceable Network Management ModuleNetwork port sharing (up to four rack PDUsshare one IP address in one enclosure)Local USB port for easy local firmware updatesMetering CapabilityActive current measurements (amps) Active power measurements(including volts, amps, real power (kW), and energy (kWh))User-customizable alarms and warningsEmbedded log memory to record/review/report historic metered data Individual outlet power metering Outlet ControlIndividual outlet remote power on/off controlPower-on sequencing and time delays with full user customizationMaintenance and UpgradeabilityRedundant internal power supply for improved SwitchedRack PDU reliabilityField-replaceable network management module4*Not applicable on AP8965. 5

Basic Rack PDUsAPC Basic Rack PDUs provide reliable power distributionvia a single input with multiple output receptacles anddistributes power from low-amperage, single-phasecircuits to higher-power, three-phase solutions.200 – 240 V Input100 – 120 V utCircuitNominalPowerInput PlugTypeCordLengthOutputReceptaclesAPC SKUVertical, 0U100 – 120NAM, LAM15 A1.4 kWNEMA 5-15P(14) 5-153.6 mAP9567Vertical, 0U120NAM20 A1.9 kWNEMA L5-20P(24) 5-203.0 mAP7530Vertical, 0U100 – 120NAM20 A1.9 kWNEMA L5-20P(14) 5-153.6 mAP9551Vertical, 0U100 – 120Japan20 A2.0 kWNEMA L5-20P(24) 5-153.0 mAP7530JVertical, 0U120NAM30 A2.9 kWNEMA L5-30P(24) 5-203.0 mAP7532Vertical, 0U100Japan30 A3.0 kWNEMA L5-30P(24) 5-153.0 mAP7532JHorizontal, 1U100 – 120NAM, LAM15 A1.4 kWNEMA 5-15P(10) 5-153.6 mAP9562Horizontal, 1U100 – 120NAM20 A1.9 kWNEMA 5-20P(10) 5-203.6 mAP9563Horizontal, 1U100 – 120NAM20 A1.9 kWNEMA L5-20P(10) 5-203.6 mAP9564Horizontal, 1U100 – 120NAM30 A2.9 kWNEMA L5-30P(10) 5-203.6 mAP9560Vertical, 0U120 – 240Worldwide10 A2.3 kWIEC-320 C14*(15) C13Vertical, 0U230GCN16 A3.5 kWIEC-309 16 A(14)C13(4)C19(6)C19Vertical, 0U230GCN16 A3.5 kWIEC-309 16 A(18)C13Vertical, 0U120 – 230Worldwide16 A3.3 kWIEC-320 C20(15) C13LAM, EMEA,GCN, APJ16 A3.7 kWIEC-309 16 A(20) C13Vertical, 0U230(4) C192.0 mAP95681.0 mAP6351CH1.0 mAP6451CH2.5 mAP95721.0 mAP7551Vertical, 0U230Worldwide16 A3.7 kWIEC-320 C20*(20) C13(4) C193.0 mAP7552Vertical, 0U200 – 240NAM20 A3.3 kWNEMA L6-20P(20) C13(4) C193.0 mAP7540Vertical, 0U200 – 240NAM30 A5.0 kWNEMA L6-30P(20) C13Vertical, 0U230GCN32 A7.0 kWIEC-309 32 A(18)C13LAM, EMEA,GCN, APJ32 A7.4 kWIEC-309 32 A(20) C13Vertical, 0U230(4) C19(6)C19(4) C193.0 mAP75412.0 mAP6453CH3.0 mAP7553Horizontal, 1U230GCN16 A3.5 kWIEC-320 C20(8) GBInletAP6201CHHorizontal, 1U230GCN16 A3.5 kWIEC-320 C20(20) C13InletAP6221CHHorizontal, 1U120 – 240Worldwide16 A3.7 kWIEC-320 C20*(10) C13Horizontal, 1U100 – 240Worldwide16 A3.7 kWIEC-320 C20*(12) C13(2) C192.5 mAP95592.5 mAP9565Horizontal, 1U208NAM, LAM20 A3.3 kWNEMA L6-20P(12) C133.6 mAP9566Horizontal, 1U208NAM30 A5.0 kWNEMA L6-30P(4) C193.0 mAP9570Horizontal, 1U200 – 240NAM, LAM30 A5.0 kWNEMA L6-30P(10) C133.6 mAP9571AHorizontal, 2U 230LAM, EMEA,GCN, APJ32 A7.4 kWHardwire(4) C198.5 mAP7585Horizontal, 2U 230LAM, EMEA,GCN, APJ32 A7.4 kWHardwire(4) IEC 309 32A8.5 mAP7586* See page 20/21 for inlet power cord optionsRack PDU Mounting Styles Horizontal 1/2U mounting6 V ertical 0Umountingwith toollessmounting S pace-saving 0Umountingoptions(AR7711)7

Basic Rack PDUs (continued .)400 – 415 VThree-phase Input208 V Three-phase utCircuitNominalPowerInput PlugTypeOutputReceptaclesCordLengthAPC SKUVertical, 0U208NAM20 A, 3ø5.8 kWNEMA L21-20P(42) 5-201.0 mAP7562Vertical, 0U208NAM20 A, 3ø5.8 kWNEMA L21-20P(42) 5-203.0 mAP7592Vertical, 0U208NAM20 A, 3ø5.8 kWNEMA L21-20P(21) 5-20(6) L6-201.0 mAP7563Vertical, 0U208NAM20 A, 3ø5.8 kWNEMA L21-20P(36) C13(6) C191.0 mAP7564Vertical, 0U200 – 240NAM50 A, 3ø12.5 kWCS8365C(30) C13(6) C191.0 mAP7568Vertical, 0U200 – 240NAM50 A, 3ø12.5 kWCS8365C(30) C13(6) C193.0 mAP7598Vertical, 0U200 – 240NAM50 A, 3ø14.4 kWCS8365C(24) C13(2) L6-30(4) C191.0 mAP7569Vertical, 0U200 – 240NAM50 A, 3ø14.4 kWCS8365C(24) C13(2) L6-30(4) C193.0 mAP7599Vertical, 0U208NAM50 A, 3ø12.5 kWCS8365C(6) C19(3) C131.8 mAP7567AHorizontal, 1U200 – 240NAM50 A, 3ø14.4 kWCS8365C(6) C192.4 mAP7516Horizontal, 2U120/208NAM30 A, Split ø5.8 kWNEMA L14-30P(4) L5-208.5 mAP7580Horizontal, 2U120/208NAM30 A, Split ø5.8 kWNEMA L14-30P(4) L6-208.5 mAP7581Horizontal, 2U120/208NAM30 A, Split ø5.8 kWNEMA L14-30P(12) 5-208.5 mAP7582Horizontal, 2U120/208NAM30 A, Split ø5.8 kWNEMA L14-30P(4) L5-308.5 mAP7583Horizontal, 2U120/208NAM30 A, Split ø5.8 kWNEMA L14-30P(4) L6-308.5 mAP7584Vertical, 0U400LAM, EMEA, 16 A, 3øGCN, APJ11 kWIEC-309 16 A 3P N PE(36) C13(6) C191.0 mAP7557Vertical, 0U400LAM, EMEA, 16 A, 3øGCN, APJ22 kWIEC-309 32 A 3P N PE(6) C19(3) C131.8 mAP7555AVertical, 0UNAM11.5 kWIEC-309 20 A 3P N PE(36) C13(6) C191.0 mAP7557NA22 kWIEC-309 32 A 3P N PE(6) C192.4 mAP7526415Horizontal, 1U 40020 A, 3øLAM, EMEA, 32 A, 3øGCN, APJChoosing APC Rack PDUsUse the Rack PDU Selector to help you choose fromour diverse rack power distribution offerings, designedto meet the needs of entry-level networking equipmentand high-density server and blade environments.The APC Rack PDU Selector can filterRack PDU selection by: Family type Output voltage Mount style (vertical or horizontal) Input plug Localized priceA wide selection of APC Rack PDUs are also availablein Schneider Electric Design Portal tools such as: InfraStruxure Designer Small IT Solution DesignerTMwww.apc.com/tools/selector/pdu/89

Metered Rack PDUs200 – 240 V Input100 – 120 V InputVoltageMetered Rack PDUs provide real-time remotemonitoring of connected loads. User-defined alarmswarn of potential circuit overloads before critical ITfailures uitNominalPowerInput PlugTypeVertical, 0U100 – 120NAM, Japan15 A1.4 kWNEMA 5-15PVertical, 0U100 – 120NAM20 A1.9 kWNEMA L5-20PVertical, 0U100 – 120Japan20 A2.0 kWVertical, 0U100 – 120Japan20 AVertical, 0U100 – 120NAM, JapanVertical, 0U100 – 120Horizontal, 1UCordLengthAPC SKU(10)(16) 5-153.0 mAP8831(24) 5-203.0 mAP8830NEMA L5-20P(24) 5-153.0 mAP8830J1.9 kWNEMA L5-20P(10) 5-153.0 mAP8833J30 A2.9 kWNEMA L5-30P(24) 5-203.0 mAP8832Japan30 A2.4 kWNEMA L5-30P(24) 5-153.0 mAP8832J120NAM, LAM15 A1.4 kWNEMA 5-15P(8) 5-153.6 mAP7800Horizontal, 1U120NAM, LAM20 A1.9 kWNEMA L5-20P(8) 5-203.6 mAP7801Horizontal, 2U120NAM, LAM30 A2.9 kWNEMA L5-30P(16) 5-203.6 mAP7802Horizontal, 2U100Japan30 A3.0 kWNEMA L5-30P(16) 5-153.6 mAP7802JVertical, 0U230Worldwide10/15 A2.3 kWIEC-320 C14(16) C133.0 mAP7850Vertical, 0U100 – 240Worldwide16 A3.3 kWIEC-320 C20*(18) C13(2) C19InletAP8858Vertical, 0U100 – 240EMEA, APJ,16 A3.7 kWIEC-309 16 A(18) C13(2) C193.0 mAP8858EU3NAM, LAMGCN, APJ20 A3.3 kWNEMA L6-20P(18) C13(2) C193.0 mAP8858NA330 A5.0 kWNEMA L6-30P(36)C13(6) C193.0 mAP8841Vertical, 0U208NAM30 A5.8 kWNEMA L14-30P(16) 5-20(2) C19(12)3.0 mAP8870Vertical, 0U220 – 240LAM, EMEA,GCN, APJ32 A7.4 kWIEC-309 32 A(36)C13(6) C193.0 mAP8853Horizontal, 1U100 – 240Worldwide10/15 A2.5 kWIEC-320 C14*(8) C13InletAP7820Horizontal, 1U100 – 240Worldwide16 A3.3 kWIEC-320 C20*(8) C13InletAP7821Horizontal, 2U200 – 240NAM30 A5.0 kWNEMA L6-30P(12) C13(4) C193.6 mAP7811LAM, EMEA,GCN, APJ32A7.4 kWIEC-309 32 A(12) C13(4) C193.6 mAP7822Vertical, 0U100 – 240Vertical, 0U200 – 240NAM, JapanLAMHorizontal, 2U 230OutputReceptacles* See page 20/21 for inlet power cord optionsRack PDU local displayLoad indicator LEDsSerial connection: local configurationand out-of-band managementAP7000 seriesLocal two-digit LEDcurrent monitoring display10User-interactivedisplay for local accessEnvironmental monitoring port forexternal temperature/humidity probeAP8000 seriesNetwork management: access, configure,and receive warnings from remotelocations via Web, SNMP, and TelnetCAN In/Out ports fornetwork port sharingLocal USB port for flash firmwareupdates and downloading data/eventlogs (not to be used as serial port)11

Metered Rack PDUs (continued .)400 – 415 VThree-phase Input208 V Three-phase InputVoltageMountingU-spaceNominalVoltageVertical, 0U208Vertical, 0U208InputCircuitNominalPowerInput PlugTypeOutputReceptaclesNAM20A, 3Φ5.7 kWNEMA L21-20P(36) 5-20NAM20 A, 3Φ5.7 kWNEMA L21-20P(24) 5-20(6) L6-20Vertical, 0U208NAM20 A, 3Φ5.7 kWNEMA L21-20P(36) C13(2) 5-20(6) C19Vertical, 0U208RegionAP88631.8 mAP88611.0 mAP7862J(36) C13(2) 5-20(6) C191.8 mAP8865Vertical, 0UCS8365C(36) C13(6) C191.8 mAP8868Vertical, 0U200 – 240NAM50 A, 3Φ14.4 kWCS8365C(24) C13(2) L6-30(4) C191.0 mAP7869Vertical, 0U200 – 240NAM50 A, 3Φ14.4 kWCS8365C(24) C13(2) L6-30(4) C193.0 mAP7899Vertical, 0U200 – 240NAM50 A, 3Φ14.4 kWCS8365C(6) C191.8 mAP7867AVertical, 0U200 – 240NAM60 A, 3Φ17.3 kWIEC-309 60 A 3P PE(12) C191.8 mAP8866Vertical, 0U200 – 240NAM60 A, 3Φ17.3 kWIEC-309 60 A 3P PE(30) C131.8 mAP8867Vertical, 0U400 – 415Worldwide16 A, 3Φ11 kWIEC-309 16 A 3P N PE(36) C13(6) C191.8 mAP8881Vertical, 0U415NAM30 A, 3Φ17.3 kWIEC-309 30 A 3P N PE(12) C19(30) C131.8 mAP8887Vertical, 0U400LAM, EMEA,GCN, APJ32 A, 3Φ22 kWIEC-309 32 A 3P N PE(12) C19(30) C131.8 mAP8886Vertical, 0U400LAM, EMEA,GCN, APJ32 A, 3Φ22 kWIEC-309 32 A 3P N PE(6) C191.8 mAP7855AVertical, 0UNAM40 A, 3Φ23 kWIEC-309 60 A 3P N PE(12) C191.8 mAP8888415What is metered on AP8800, AP8400,AP8900, and AP8600 Series Rack PDUs? Device: Power and energy Phase: Current*, power, and voltage Internal circuit breaker (bank): Current* Outlet: Current, power, energy(AP8600 & AP8400 Series only)*AP7000 series monitors current per phase and breaker only.12AP88623.0 m(42) 5-1550 A, 3Φ6.0 kW3.0 mNEMA L21-20PNAM20 A, 3ΦAPC SKUVertical, 0U208NAM30 A, 3Φ8.6 kWNEMA L21-30P200 – 240JapanCordLength10.0 kW(6) C13(30) C13Why do we meter? Device: Rack level capacity change, planning,and efficiency calculations Phase: Balance loads between phases to protectagainst tripping upstream branch circuit breakers Internal circuit breaker (bank): Protect againsttripping internal circuit breakers Outlet: Detailed capacity change, equipmentefficiency, and trends13

Metered-by-Outlet Rack tNominalPowerInput PlugTypeOutputReceptacles100 –120 VInputVertical, 0U100 – 240Worldwide16 A3.3 kWIEC-320 C20*(21) C13200 – 240 V InputVertical, 0U200 - 240NAM, LAM,Japan20 A3.3 kWNEMA L6-20PVertical, 0U200 - 240LAM, EMEA,GCN, APJ16 A3.7 kWVertical, 0U200 - 240NAM, Japan,LAM30 AVertical, 0U200 - 240LAM, EMEA,GCN, APJ208 VThreephaseVertical, 0UNAM400-415 VThree-phaseInputMetered-by-Outlet Rack PDUs provide real-time remotemonitoring of each individual outlet to empower ITprofessionals with the necessary tools for advanceddata center energy management.VoltageVertical, 0U400 - 415Worldwide16A, 3Φ11 kWIEC-309 16 A3P N PE208CordLengthAPC SKU(3) C193.0 mAP8459WW(21) C13(3) C193.0 mAP8459NA3IEC-309 16 A(21) C13(3) C193.0 mAP8459EU35.0 kWNEMA L6-30P(21) C13(3) C193.0 mAP844132 A7.4 kWIEC-309 32 A(21) C13(3) C193.0 mAP845320A, 3Φ5.7 kWNEMA L21-20P(21) C13(3) C191.8 mAP8461(21) C13(3) C191.8 mAP8481* See page 20/21 for inlet power cord optionsRack PDU Software options:APC Intelligent Rack PDUs provide remote powerutilization data and optional outlet control to allowdata center managers to make informed decisionson load balancing and right-sizing IT environmentsto lower total cost of ownership. Latest featureadditions include Cisco EnergyWise , wirelesssensor capability, and network port sharing.Integration with StruxureWare forData Centers SoftwareAPC Rack PDUs, when combined with StruxureWareData Center Operations, help provide an instant overviewof data center operations with additional inventorymanagement, PUE calculation, real-time device alarms,and location-based drill-down of power distribution.TMRemote access to Intelligent Rack PDUs is available via: Web browser Telnet (CLI) SNMP1415

Switched Rack PDUsSwitched Rack PDUs provide advanced load monitoringcombined with remote on/off switching control ofindividual outlets for power cycling, delayed powersequencing, and outlet use tCircuitNominalPowerInput PlugTypeOutputReceptaclesCordLengthAPC SKUVertical, 0U100 – 120NAM, Japan15 A1.4 kWNEMA 5-15P(16)8 5-153.0 mAP8931Vertical, 0U120NAM20 A1.9 kWNEMA L5-20P(24) 5-203.0 mAP8930Vertical, 0U100Japan20 A1.9 kWNEMA L5-20P(24) 5-153.0 mAP8930JVertical, 0U120NAM, Japan30 A2.9 kWNEMA L5-30P(24) 5-203.0 mAP8932Horizontal, 1U100 – 120NAM, LAM15 A1.4 kWNEMA 5-15P(8) 5-153.6 mAP7900Horizontal, 1U100 – 120NAM20 A1.9 kWNEMA L5-20P(8) 5-203.6 mAP7901Horizontal, 2U120NAM30 A2.9 kWNEMA L5-30P(16) 5-203.6 mAP7902Horizontal, 2U100Japan32 A3.0 kWNEMA L5-30P(16) 5-153.6 mAP7902JVertical, 0U230EMEA, GCN,APJ10 A2.3 kWIEC-320 C14*(16) C133.0 mAP7950Vertical, 0U100 – 240NAM, LAM20 A3.3 kWNEMA L6-20P(7) C13(1) C193.0 mAP8958NA3Vertical, 0U100 – 240Worldwide16 A3.3 kWIEC-320 C20*(7) C13(1) C19InletAP8958Vertical, 0U230LAM, EMEA,GCN, APJ16 A3.7 kWIEC-309 16 A(7) C13(1) C193.0 mAP8958EU3Vertical, 0U100 – 240NAM, LAM20 A3.3 kWNEMA L6-20P(21) C13(3) C193.0 mAP8959NA3Vertical, 0U100 – 240Worldwide16 A3.3 kWIEC-320 C20*(21) C13(3) C19InletAP8959Vertical, 0U230LAM, EMEA,GCN, APJ16 A3.7 kWIEC-309 16 A(21) C13(3) C193.0 mAP8959EU3Vertical, 0UNAM, LAM30 A5.0 kWNEMA L6-30P(21) C13(3) C193.0 mAP8941200 – 240Vertical, 0U120/208NAM30 A5.8 kWNEMA L14-30P(16) 5-20(12) C133.0 mAP8970(2) C19Vertical, 0U220 – 240LAM, EMEA,GCN, APJ32 A7.4 kWIEC-309 32 A(21) C133.0 mAP8953Horizontal, 1U208 – 230Worldwide10/15 A2.5 kWIEC-320 C14*(8) C132.0 mAP7920Horizontal, 1U208 – 230Worldwide16 A3.3 kWIEC-320 C20*(8) C132.4 mAP7921Horizontal, 2U200 – 240NAM30 A5.0 kWNEMA L6-30P(16) C133.6 mAP7911AHorizontal, 2U 230LAM, EMEA,GCN, APJ32 A7.4 kWIEC-309 32 A(16) C133.6 mAP7922208 VThree-phaseInput(3) C19Vertical, 0U208NAM20 A, 3ø5.7 kWNEMA L21-20P(21) C131.8 mAP8961Vertical, 0U208NAM20A, 3 Φ6.0 kWNEMA L21-20P(24) 5-203.0 mAP8962Vertical, 0U208NAM30 A, 3ø8.6 kWNEMA L21-30P(21) C13(3) C191.8 mAP8965Vertical, 0U200 – 240NAM50 A, 3ø12.5 kWCS8365C(21) C13(3) C191.0 mAP7968Vertical, 0U200 – 240NAM50 A, 3ø12.5 kWCS8365C(21) C13(3) C193.0 mAP7998400 – 415 VThree-phaseInput200 – 240 V Input100 – 120 V InputVoltageVertical, 0U400 – 415 Worldwide16 A, 3ø11 kWIEC-309 16 A3P N PE(21) C13(3) C191.8 mAP898116(3) C19* See page 20/21 for inlet power cord options17

Metered-by-Outlet withSwitching Rack put PlugTypeOutputReceptaclesCordLengthAPC SKUVertical, 0U100-120NAM, Japan30 A2.9 kWNEMA L5-30P(24) 5-203.0 mAP8632208NAM20 A3.3 kWNEMA L6-20P(21) C13(3) C193.0 mAP8659NA3100 – 240Worldwide20 A3.3 kWIEC-320 C20*(21) C13(3) C19InletAP8659LAM, EMEA,GCN, APJ16 A3.7 kWIEC-309 16 A(21) C13(3) C193.0 mAP8659EU3Vertical, 0U200 – 240NAM, JapanLAM30 A5.0 kWNEMA L6-30P(21) C13(3) C193.0 mAP8641Vertical, 0U220 – 240LAM, EMEA,GCN, APJ32 A7.4 kWIEC-309 32 A(21) C13(3) C193.0 mAP8653Vertical, 0U208NAM20 A, 3ø5.7 kWNEMA L21-20P(21) C13(3) C191.8 mAP8661Vertical, 0U400 – 415Worldwide16 A, 3ø11 kWIEC-309 16 A 3P N PE(21) C13(3) C191.8 mAP8681200 – 240 VInputVertical, 0UVertical, 0U208 VThreephaseInputMountingU-space400 – 415 et with Switching Rack PDUs providereal-time remote monitoring of each individual outletcombined with remote on/off outlet switching control toempower IT professionals with the necessary tools forcomplete control their power distribution and advanceddata center energy management.Vertical, 0U230* See page 20/21 for inlet power cord optionsAP8661Rack-mount Transfer SwitchInput VoltageMountingInput CircuitU-spaceInput Plug TypeOutput ReceptaclesCord LengthAPC SKU100 V100/120 V120 V120 V120 ANEMA L5-20P(8) 5-152.4 mAP7752J115 ANEMA 5-15P(8) 5-152.4 mAP7750A120 ANEMA L5-20P(10) 5-202.4 mAP7752230 ANEMA L5-30P(16) 5-202.4 mAP7753120 ANEMA L6-20P(8) C13, (1) C192.4 mAP7730230 ANEMA L6-30P(16) C13, (2) C192.4 mAP7732230 ANEMA L6-30P(1) L6-30R2.4 mAP7731115 AIEC-C14 Inlet(12) C13NoneAP7721120 AIEC-C20 Inlet(8) C13, (1) C19NoneAP7723116 A(2) IEC-309(1) IEC-3090.9 mAP7722A232 AIEC-309(16) C13, (2) C192.4 mAP7724120 A, 3øNEMA L21-20P(1) L21-20R0.9 mAP7701200 – 208 V200 – 208 V208 V208/230 V200-/230 V230 V230 V208 V 3ø1819

Locking IEC Power CordsPDUInputServerInputIEC C14IEC-C13StraightIEC C14IEC-C13(Three right, three left)IEC C20IEC-C19StraightIEC C20IEC-C19(Three right, three left)CordLengthCordsper SKUAPC SKU0.6 m1.2 m1.8 m0.6 m1.2 m1.8 m0.6 m1.2 m1.8 m0.6 m1.2 m1.8 16RLocking IEC power cords provide a mechanismto secure power cord connections to the RackPDU when used with any AP8000 Series unit.*-NA and -WW designation are required in SKU numbers forAP870xS and AP870xR e.g., AP8702S-NA.Input Power CordsInput power cords for devices with C14 or C20 inlet.Locking PDU InputPlug typeCord Length APC SKUNEMA 5-15P3.0 mAP8750Non-lockingPDU InputPlug typeCordAPC SKULengthIEC-C19 StraightIEC-C19 StraightNEMA 5-20P3.0 mAP8751IEC-C19 StraightNEMA L6-20P3.7mAP9871IEC-C19 StraightNEMA L5-20P3.0 mAP8752IEC-C19 StraightNEMA 5-20P2.5mAP9872IEC-C19 StraightNEMA L5-20P3.0 mAP8752JIEC-C19 StraightNEMA L5-20P2.5mAP9873IEC-C19 StraightNEMA L6-20P3.0 mAP8753IEC-C19 StraightShuko (CEE 7)2.5mAP9875IEC-C19 StraightNEMA L6-20P3.0 mAP8753JIEC-C19 StraightIEC-3092.5mAP9876IEC-C19 StraightAustralia AS31123.0 mAP8754IEC-C13 StraightNEMA 5-15P2.4mAP9893IEC-C19 StraightShuko (CEE 7)3.0 mAP8755IEC-C13 StraightNEMA L5-15P2.4mAP9894IEC-C19 StraightUK (BS1363)3.0 mAP8756IEC-C19 StraightUK (BS1363)2.4mAP9895IEC-C19 StraightChina (16A)3.0 mAP8757IEC-C19 StraightNEMA L6-30P2.4mAP9896IEC-C19 StraightIEC-3093.0 mAP8758IEC-C19 StraightAustralia AS31123.7mAP9897IEC-C19 StraightRewireable3.0 mAP8759Bracket hAPCSKUTemp. sensorRJ-453.9 mAP9335TTemp. and humidity sensorRJ-453.9 mAP9335THDescriptionAPC SKUVertical, 0U mounting bracketsfor Dell and Rittal enclosuresAP7400*Vertical, 0U mounting bracketsfor HP enclosuresAP7406*NetShelter SX and third party racks,0U accessory and PDU bracketAR7711Note: Environmental sensors only compatible with AP8000 Series Rack PDUs.Each Rack PDU includes one environmental sensor port for an optional sensor.Horizontal to Vertical,0U mounting bracket for horizontal 1U Rack PDUsAR8417 TM*Brackets for AP7000 series Rack PDUs only.2021

AR3100NetShelter SX 42U 600mm Wide x 1070mmDeep EnclosureTAAAR3104NetShelter SX 24U 600mm x 1070mmDeep EnclosureSPAR3105NetShelter SX 45U 600mm Wide x 1070mmDeep Enclosure with Sides BlackTAAXSPAR3107NetShelter SX 48U 600mm Wide x 1070mmDeep EnclosureTAAXSPAR3150NetShelter SX 42U 750mm Wide x 1070mmDeep EnclosureWXSPAR3155NetShelter SX 45U 750mm Wide x 1070mmDeep Enclosure with Sides BlackSPAR3157NetShelter SX 48U 750mm Wide x 1070mmDeep EnclosureXSPAR3300NetShelter SX 42U 600mm Wide x 1200mmDeep EnclosureWXAR3305NetShelter SX 45U 600mm Wide x 1200mmDeep Enclosure with Sides BlackSPAR3307NetShelter SX 48U 600mm Wide x 1200mmDeep EnclosureWXSPAR3350NetShelter SX 42U 750mm Wide x 1200mmDeep EnclosureWXSPAR3355NetShelter SX 45U 750mm Wide x 1200mmDeep Enclosure with Sides BlackXSPAR3357NetShelter SX 48U 750mm Wide x 1200mmDeep EnclosureXSPAR3140NetShelter SX 42U 750mm Wide x 1070mmDeep Networking Enclosure with SidesWAR3340NetShelter SX 42U 750mm Wide x 1200mmDeep Networking Enclosure with SidesWAR3347NetShelter SX 48U 750mm Wide x 1200mmDeep Networking Enclosure with SidesAR3200NetShelter SX Colocation 2 x 20U 600mmWide x 1070mm Deep Enclosure withSides BlackAR3810NetShelter AV 42U 600mm Wide x 825mmDeep Enclosure with Sides and 10-32Threaded Rails BlackAR3812NetShelter AV 42U 600mm Wide x 825mmDeep Enclosure 10-32 Threaded Rails NoSides/Roof/Doors BlackAR3814NetShelter AV 24U 600mm Wide x 825mmDeep Enclosure with Sides and 10-32Threaded Rails BlackAR2144BLKNetShelter VX Seismic 42U Enclosure w/Sides BlackAR2145BLKNetShelter VX Seismic 42U Enclosure w/outSides BlackWXSPATO options Without sides add X609 Without doors add X610 Without sides & doors add X617e.g. AR3100X609 - 42U x 24in W42in deep without sides22PartNumberDescriptionAR2400FP1NetShelter SV 42U 600mm Wide x 1060mmDeep Enclosure with Sides, Black, SingleRack UnassembledAR2400NetShelter SV 42U 600mm Wide x 1060mmDeep Enclosure with Sides BlackAR2401NetShelter SV 42U 600mm Wide x 1060mmDeep Enclosure without Sides BlackAR2407NetShelter SV 48U 600mm Wide x 1060mmDeep Enclosure with Sides BlackAR2480NetShelter SV 42U 800mm Wide x 1060mmDeep Enclosure with Sides BlackAR2487NetShelter SV 48U 800mm Wide x 1060mmDeep Enclosure with Sides BlackAR2500NetShelter SV 42U 600mm Wide x 1200mmDeep Enclosure with Sides BlackAR2507NetShelter SV 48U 600mm Wide x 1200mmDeep Enclosure with Sides BlackAR2580NetShelter SV 42U 800mm Wide x 1200mmDeep Enclosure with Sides BlackAR2587NetShelter SV 48U 800mm Wide x 1200mmDeep Enclosure with Sides BlackAR201NetShelter 2 Post Rack 45U #12-24Threaded Holes BlackAR203ANetShelter 4 Post Open Frame Rack 44USquare HolesAR204ANetShelter 4 Post Open Frame Rack 44U#12-24 Threaded HolesVDIM33174Overhead Zone Cabling 4U 19 in (482 mm)W Patch FrameAR4000MVNetShelter CX Mini soundproofed ServerRoom in a Box EnclosureAR4018ANetShelter CX 18U Secure SoundproofServer Room in a Box EnclosureAR4024ANetShelter CX 24U Secure SoundproofServer Room in a Box EnclosureAR4038ANetShelter CX 38U Secure SoundproofServer Room in a Box EnclosureAR100NetShelter WX 13U w/ Square or ThreadedHole 12-24 Vertical Mounting Rail GlassFront Door BlackAR100HDNetShelter WX 13U w/ Square or ThreadedHole 12-24 Vertical Mounting Rail VentedFront Door BlackAR106NetShelter WX 6U w/ Square VerticalMounting Rail Vented Front Door BlackAR109NetShelter WX 9U w/ Square VerticalMounting Rail Vented Front Door BlackAR112NetShelter WX 12U w/ Square VerticalMounting Rail Vented Front Door BlackAlternateoptionSPData Center, Server Room, Network ClosetDescriptionData Center, ServerRoom, Network ClosetPartNumberRemote LocationsWallmountedPremium Data Center InfraStruxure & Server RoomChoose a Rack SystemXTAAAlternateoptionoptions without sides add X609 without doors add X610, without sides/doors add X617TAA compliant add TAAWWhite color add WSPShock packaging for up to 2000lb of equipment add SP23

Rack LCD ConsolesKVM SwitchesRack LCD ConsolesAPC SKU17" Rack LCD consoleAP571719" Rack LCD consoleAP5719 Ultra-thin 17" or 19" LCD monitorKVM Switches with CAT-5 Type ConnectionAPC SKU32-port Digital Enterprise IP KVMwith Virtual Media, two remote usersKVM2132P16-port Digital Enterprise IP KVMwith Virtual Media, two remote usersKVM2116P16-port Digital IP KVM with Virtual Mediaone remote userKVM1116P Easy to install16-port Analog Enterprise KVM with Virtual Media,two local usersKVM0216A Localized keyboard versions available;check www.apc.com for availability16-port Analog KVM, one local userKVM0116A8-port Analog KVM, one local userKVM0108AKVM USB Server ModuleKVM-USBKVM PS/2 Server ModuleKVM-PS2KVM USB Server Module with Virtual MediaKVM-USBVMKVM PS/2 Server Module with Virtual MediaKVM-PS2VMKVM USB Server Module with Virtual Mediaand CAC SupportKVM-USBVMCACKVM Serial Server ModuleKVM-SERIALKVM to APC Rack PDU Power Management CableAP5641KVM 1U Bracket for rear mountbehind Rack LCD ConsoleKVM Access Software License Upgradeto Enterprise (1,024 Nodes) Integrated keyboard with number pad USB port for external media Space-saving 1U design Touchpad mouseRack LCD Consolewith Integrated KVM SwitchCableLengthAPC SKU17" Rack LCD consolewith integrated 8-port KVM Switch1.8 mAP5808KVM-LCDMOUNT17" Rack LCD consolewith integrated 16-port KVM Switch1.8 mAP5816SEKVM1024NKVM USB cable1.8 mAP5821KVM USB cable3.0 mAP5822KVM USB cable5.2 mAP5823* KVM PS/2 cables available, see cables for coaxial type connection on page 20.Rear view of AP5202KVM Switches with Coaxial Type ConnectionAPC SKU8-port analog KVMAP520116-port analog KVMAP5202Cables for CoaxialType Connection0.9 m0.5 m3.7 m7.6 mKVM USB cableAP5253AP5257AP5261KVM PS/2 cableAP5250AP5254AP5258KVM Daisy-chain cable240.6 mAP5264AP5262Rear view of AP5816The functionality of a Rack LCD console and an analog KVMswitch in one convenient package optimizes U-space in therack environment and eliminates cable clutter. Daisy-chain withAP5201 or AP5202 for additional ports.AP526325

Receptacle and Plug TypesVoltageAmpsTypicalRating# WiresPlug NameMating Connector100 – 120 V15 A1.4 kW3NEMA 5-15PNEMA 5-15R20 A1.9 kW3NEMA 5-20PNEMA 5-20R20 A1.9 kW3NEMA L5-20PNEMA L5-20R30 A2.9 kW3NEMA L5-30PNEMA L5-30R15 A2.5 kW3IEC-C14IEC-C1316 A3.7 kW3IEC-309 16 A, 2P, 3WIEC-309 16 A, 2P, 320 A3.3 kW3IEC-C20IEC-C1920 A3.3 kW3NEMA L6-20PNEMA L6-20R30 A5.0 kW3NEMA L6-30PNEMA L6-30R32 A7.4 kW3IEC-309 32 A, 2P, 3WIEC-309 32 A, 2P, 3W120 / 208 V30 A5.8 kW3NEMA L14-30PNEMA L14-30R208 VThree-phase20 A5.8 kW5NEMA L21-20PNEMA L21-20R30 A8.7 kW5NEMA L21-30PNEMA L21-30R50 A12.5 – 14.4 kW4CS8365CCS8364C, CS836960 A16.2 – 17.3 kW4IEC-309 60 A, 3P, 4WIEC-309 60 A, 3P, 4W16/20 A11 kW5IEC-309 16/20 A, 3P, 5WIEC-309 16/20 A, 3P, 5W32 A22 kW5IEC-309 32 A, 3P, 5WIEC-309 32 A, 3P, 5W40 A23 kW5IEC-309 60 A, 3P, 5WIEC-309 60 A, 3P, 5W200 – 240 V400 – 415 VThree-phaseExtended Warranties*APC offers extended warranties that provide a continuation ofcoverage beyond the original factory warranty period. This serviceextends the security and protection provided by your factorywarranty and ensures that your product will be repaired or replaced ifnecessary, at no additional charge. Extended warranties are availablefor purchase in one-year increments.This service is available for all Rack PDUs, Rack ATSs, Rack LCDconsoles, and KVM switches, and includes: Technical support from product-specific support engineers toassist with questions or concerns Cross shipment of parts or replacement product — no waitingfor your critical equipmentAdd an extended warranty to your shopping cart on www.apc.comfor new purchases or purchase an extended warranty for yourexisting product.* Check with your local sales representative for extended warranty services available.2627

Find out more:The Rack PDU Selector is located at:www.apc.com/tools/selector/pduTest drive a metered or switched Rack PDU at:testdrive.apc.comwww.apc.com 2015 Schneider Electric. All Rights Reserved. Schneider Electric, APC, InfraStruxure,StruxureWare, and NetShelter are trademarks owned by Schneider Electric IndustriesSAS or its affiliated companies. All other trademarks are the property of theirrespective owners. www.schneider-electric.com 998-1165125 GMA-US A

The AP8000 Series Rack PDU platform will help IT and facilities managers more effectively manage power capacity and functionality for critical network, server, and data center equipment. These Rack PDUs solve rack-level power needs while incorporating intelligent features, such as real power measurement and environmental monitoring, all in a space-