UL LLC ISSUES THIS Certificate Of Participation - Siemens

Transcription

UL LLC ISSUES THISCertificate of ParticipationSIEMENS AGPEHLA - Testing Laboratory Frankfurt am Main, Carl-Benz-Strasse 22, Frankfurt am Main 60386, GERMANYThe laboratory above has been assessed and found to comply with the applicablerequirements of ISO/IEC 17025 In accordance with UL’s Data Acceptance Program (DAP)and has been qualified as a DAP participant. The laboratory is hereby authorized to submittesting data to UL for product certification purposes as allowed by the schemes a nd for theproduct types and standards identified in the DAP Scope.Client Test Data Program (CTDP)DA File: DA2443Issued: 1/31/2022Expires: 2/3/2023Kevin MehaffeyProgram Owner

Project Number: SR5567548StandardNumber:Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022Standard Edition(Amendment):Standard Title:/File Number: DA2443Test method:Clause:ATTACHMENT A - Post Audit Scope (182 Tests Total)CSA-C22.2No. 31Switchgear Assemblies108.5.1HIGH VOLTAGE SWITCHGEAR ASSEMBLIES DIELECTRIC STRENGTHCSA-C22.2No. 31Switchgear Assemblies108.5.2HIGH VOLTAGE SWITCHGEAR ASSEMBLIES IMPULSECSA-C22.2No. 31Switchgear Assemblies108.5.3HIGH VOLTAGE SWITCHGEAR ASSEMBLIES CORONA EXTINCTIONCSA-C22.2No. 31Switchgear Assemblies118.5.1HIGH VOLTAGE SWITCHGEAR ASSEMBLIES DIELECTRIC STRENGTHCSA-C22.2No. 31Switchgear Assemblies118.5.2HIGH VOLTAGE SWITCHGEAR ASSEMBLIES IMPULSE TESTCSA-C22.2No. 31Switchgear Assemblies118.5.3HIGH VOLTAGE SWITCHGEAR ASSEMBLIES CORONA EXTINCTION TESTCSA-C22.2No. 58High-Voltage Isolating Switches26.2TEMPERATURE RISECSA-C22.2No. 58High-Voltage Isolating Switches26.3DIELECTRIC STRENGTHCSA-C22.2No. 58High-Voltage Isolating Switches26.4IMPULSE AND CORONA EXTINCTIONCSA-C22.2No. 58High-Voltage Isolating Switches26.5MECHANICAL ENDURANCECSA-C22.2No. 193High Voltage Full-Load Interrupter Switches19865.2IMPULSE WITHSTANDCSA-C22.2No. 193High Voltage Full-Load Interrupter Switches19865.3DIELECTRIC STRENGTHCSA-C22.2No. 193High Voltage Full-Load Interrupter Switches19865.4TEMPERATURE RISECSA-C22.2No. 193High Voltage Full-Load Interrupter Switches19865.7MECHANICAL ENDURANCEIEC 60529Degrees of Protection Provided by Enclosures (IPCode)2.212TESTS FOR PROTECTION AGAINST ACCESS TOHAZARDOUS PARTSIEC 60529Degrees of Protection Provided by Enclosures (IPCode)2.214.2.3TEST FOR SECOND CHARACTERISTIC NUMERAL3 WITH OSCILLATING TUBE OR SPRAY NOZZLE2.214.2.4WATER SPRAY TEST FOR ENCLOSUREDESIGNATION IPX415GENERAL REQUIREMENTS FOR TESTS16TEST FOR PROTECTION AGAINST MECHANICALIMPACTS17TEST APPARATUS20177.2DIELECTRIC20177.4RESISTANCE MEASUREMENTIEC 60529IEC 62262IEC 62262Degrees of Protection Provided by Enclosures (IPCode)Degrees of Protection Provided by Enclosures forElectrical Equipment Against External MechanicalImpacts (IK Code)Degrees of Protection Provided by Enclosures forElectrical Equipment Against External MechanicalImpacts (IK Code)Degrees of Protection Provided by Enclosures forElectrical Equipment Against External MechanicalImpacts (IK Code)IEC 62271- High-Voltage Switchgear and Controlgear - Part 1:1Common SpecificationsIEC 62271- High-Voltage Switchgear and Controlgear - Part 1:1Common SpecificationsIEC 62262Page 6 of 13

Project Number: SR5567548StandardNumber:Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022Standard Title:IEC 62271- High-Voltage Switchgear and Controlgear - Part 1:1Common SpecificationsIEC 62271- High-Voltage Switchgear and Controlgear - Part 1:1Common SpecificationsIEC 62271- High-Voltage Switchgear and Controlgear - Part 1:1Common SpecificationsIEC 62271High-voltage switchgear and controlgear 100Part 100: Alternating-current circuit-breakersIEC 62271High-voltage switchgear and controlgear 100Part 100: Alternating-current circuit-breakersIEC 62271High-voltage switchgear and controlgear 100Part 100: Alternating-current circuit-breakersIEC 62271High-voltage switchgear and controlgear 100Part 100: Alternating-current circuit-breakersIEC 62271High-voltage switchgear and controlgear 100Part 100: Alternating-current circuit-breakersIEC 62271High-voltage switchgear and controlgear 100Part 100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersIEC 62271- High-voltage switchgear and controlgear – Part100100: Alternating-current circuit-breakersHigh-Voltage Switchgear and Controlgear - PartIEC 62271102: Alternating Current Disconnectors and102Earthing Switches/File Number: DA2443Standard Edition(Amendment):Clause:Test method:20177.5CONTINUOUS CURRENT20177.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND SUREMENT OF THE RESISTANCE OF THEMAIN CIRCUIT20176.5TEMPERATURE-RISE20176.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENT TESTS20176.8TIGHTNESS20176.101MECHANICAL AND ENVIRONMENTAL20217.2Dielectric tests20217.4Resistance measurement20217.5Continuous current tests20217.6Short-time withstand current and peak withstandcurrent tests20217.7Verification of the protection20217.8Tightness tests20217.10Additional tests on auxiliary and control circuits20217.101Mechanical and environmental tests20187.2DIELECTRICIEC 62271102High-Voltage Switchgear and Controlgear - Part102: Alternating Current Disconnectors andEarthing Switches20187.4RESISTANCE MEASUREMENTIEC 62271102High-Voltage Switchgear and Controlgear - Part102: Alternating Current Disconnectors andEarthing Switches20187.5CONTINUOUS CURRENTIEC 62271102High-Voltage Switchgear and Controlgear - Part102: Alternating Current Disconnectors andEarthing Switches20187.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENTIEC 62271102High-Voltage Switchgear and Controlgear - Part102: Alternating Current Disconnectors andEarthing Switches20187.8TIGHTNESSIEC 62271102High-Voltage Switchgear and Controlgear - Part102: Alternating Current Disconnectors andEarthing Switches20187.102OPERATING AND MECHANICAL ENDURANCEIEC 62271103High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kVup to and including 52 kV20116.2DIELECTRICIEC 62271103High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kVup to and including 52 kV20116.4MEASUREMENT OF THE RESISTANCE OFCIRCUITSIEC 62271103High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kVup to and including 52 kV20116.5TEMPERATURE-RISEIEC 62271103High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kVup to and including 52 kV20116.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENTPage 7 of 13

Project Number: SR5567548Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022/File Number: DA2443StandardNumber:Standard Title:Standard Edition(Amendment):Clause:Test method:IEC 62271103High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kVup to and including 52 kV20116.8TIGHTNESSIEC 62271103High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kVup to and including 52 kV20116.102MECHANICAL AND ENVIRONMENTALHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.2Dielectric testsHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.4Resistance measurementHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.5Continuous current testsHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.6Short-time withstand current and peak withstandcurrent testsHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.7Verification of the protectionHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.8Tightness testsHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.10Additional tests on auxiliary and control circuitsHigh-voltage switchgear and controlgear – PartIEC 62271103: Alternating current switches for rated voltages103above 1 kV up to and including 52 kV20217.102Mechanical and environmental testsIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.13MECHANICAL ENDURANCE TESTSIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.14CONTROL VOLTAGEIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.17SEALED PRESSURE SYSTEMS LEAKAGE TESTSIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.3CONTINUOUS CURRENT-CARRYING TESTSIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.4.3POWER FREQUENCY WITHSTAND VOLTAGETESTSIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.4.3.1POWER FREQUENCY WITHSTAND VOLTAGETESTS - DRY TESTS PROCEDUREIEEEC37.09Standard Test Procedure for AC High-VoltageCircuit Breakers Rated on a Symmetrical CurrentBasis20074.4.4FULL-WAVE LIGHTNING IMPULSE WITHSTANDVOLTAGE TESTSIEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.4CONTINUOUS CURRENT-CARRYINGPage 8 of 13

Project Number: SR5567548Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022/File Number: DA2443StandardNumber:Standard Title:Standard Edition(Amendment):Clause:Test method:IEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.5.4POWER FREQUENCY WITHSTAND VOLTAGEIEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.5.4.1DRY TESTS PROCEDUREIEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.5.5FULL-WAVE LIGHTNING IMPULSE WITHSTANDVOLTAGEIEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.13IEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.15CONTROL VOLTAGEIEEEC37.09Standard Test Procedures for AC High-VoltageCircuit Breakers with Rated Maximum VoltageAbove 1000 V20184.18SEALED PRESSURE SYSTEMS TIGHTNESSTESTSMETAL-CLAD SWITCHGEAR16.2.1DESIGN - DIELECTRIC TESTSMETAL-CLAD SWITCHGEAR16.2.1.1METAL-CLAD SWITCHGEAR16.2.1.2METAL-CLAD SWITCHGEAR16.2.1.3METAL-CLAD SWITCHGEAR16.2.2DESIGN - RATED CONTINUOUS CURRENT TESTSMETAL-CLAD SWITCHGEAR16.2.3MOMENTARY WITHSTAND CURRENTMETAL-CLAD SWITCHGEAR16.2.4SHORT-TIME WITHSTAND CURRENTMETAL-CLAD SWITCHGEAR16.2.6MECHANICAL ENDURANCE TESTSMetal-Clad Switchgear20156.2.1DESIGN - DIELECTRIC TESTSMetal-Clad Switchgear20156.2.1.1Metal-Clad Switchgear20156.2.1.2Metal-Clad Switchgear20156.2.1.3Metal-Clad Switchgear20156.2.2DESIGN - RATED CONTINUOUS CURRENT TESTSMetal-Clad Switchgear20156.2.3MOMENTARY WITHSTAND CURRENTMetal-Clad Switchgear20156.2.4SHORT-TIME WITHSTAND CURRENTMetal-Clad Switchgear20156.2.6MECHANICAL ENDURANCE TESTS16.2.1DESIGN - DIELECTRIC TESTS16.2.1.1POWER-FREQUENCY WITHSTAND TESTS16.2.1.2LIGHTING-IMPULSE WITHSTAND TESTS16.2.2CONTINUOUS CURRENT TESTS16.2.3SHORT-TIME WITHSTAND CURRENT16.2.4MOMENTARY WITHSTAND CURRENT16.2.5MECHANICAL ENDURANCE 37.20.3IEEEC37.20.3IEEEC37.20.3METAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMECHANICAL ENDURANCEDIELECTRIC TESTS - POWER FREQUENCYWITHSTAND TESTSDIELECTRIC TESTS - LIGHTENING IMPULSEWITHSTAND TESTSDIELECTRIC TESTS - TEST FOR BUS-BARINSULATIONDIELECTRIC TESTS - POWER FREQUENCYWITHSTAND TESTSDIELECTRIC TESTS - LIGHTENING IMPULSEWITHSTAND TESTSDIELECTRIC TESTS - TEST FOR BUS-BARINSULATIONPage 9 of 13

Project Number: EEC37.20.7IEEEC37.20.7IEEEC37.20.9IEEEC37.20.9Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022Standard Title:METAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMETAL-ENCLOSED INTERRUPTERSWITCHGEARMetal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Metal-Enclosed Interrupter Switchgear (1 kV-38kV)Indoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearIndoor AC Switches (1 kV - 38 kV) for Use in MetalEnclosed SwitchgearINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARINDOOR AC SWITCHES (1KV-38KV) FOR USEIN METAL ENCLOSED SWITCHGEARIEEE Guide for TestingSwitchgear Rated Up to 52 kVfor Internal Arcing FaultsIEEE Guide for TestingSwitchgear Rated Up to 52 kVfor Internal Arcing FaultsMetal-Enclosed Switchgear Rated 1 kV to 52 kVIncorporating Gas Insulating SystemsMetal-Enclosed Switchgear Rated 1 kV to 52 kVIncorporating Gas Insulating Systems/File Number: DA2443Standard TEST FOR BUS-BAR INSULATION20136.12MECHANICAL ENDURANCE TESTS20136.14.1TEST FOR BUS-BAR INSULATION20136.2.5.1GENERAL CASE20136.2.6.1POWER FREQUENCY VOLTAGE TESTS20136.2.6.2LIGHTNING IMPULSE VOLTAGE TESTS20136.2.9PARTIAL DISCHARGE TESTS - OPTIONAL20136.4MEASUREMENT OF RESISTANCE OF CIRCUITS20136.5TEMPERATURE RISE TEST20136.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENT TESTS20136.12MECHANICAL OPERATIONS TESTS20136.2.6.1POWER FREQUENCY VOLTAGE TESTS20136.2.6.2LIGHTNING IMPULSE VOLTAGE TESTS20136.4MEASUREMENT OF THE RESISTANCE OFCIRCUITS20136.5CONTINUOUS CURRENT20136.6SHORT-TIME WITHSTAND CURRENT20136.6PEAK WITHSTAND CURRENT (FORMERLYMOMENTARY) TEST20136.8TIGHTNESS20016.2.1DIELECTRIC TESTS20016.2.1.120016.2.1.220016.2.2CONTINUOUS CURRENT TESTS20016.2.3.2MOMENTARY WITHSTAND CURRENT20016.2.3.3SHORT-TIME WITHSTAND CURRENT20016.2.5MECHANICAL OPERATION 7.4MEASUREMENT OF RESISTANCE OF CIRCUITSTest method:DESIGN - MECHANICAL ENDURANCE STATIONARY SWITCHESMECHANICAL ENDURANCE - DRAWOUTSWITCHESPOWER FREQUENCY WITHSTAND VOLTAGETESTSLIGHTNING IMPULSE WITHSTAND VOLTAGETESTSPage 10 of 13

Project Number: SR5567548Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022/File Number: DA2443Standard Edition(Amendment):Clause:Test method:20197.5CONTINUOUS CURRENT (TEMPERATURE-RISE)20197.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENT20197.8TIGHTNESS20197.12MECHANICALStandard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.2.11VOLTAGE TEST AS CONDITION CHECKIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.2.6.1POWER FREQUENCY VOLTAGE TESTSIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.2.6.2LIGHTNING IMPULSE VOLTAGE TESTSIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.2.9PARTIAL DISCHARGE TESTSIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.4MEASUREMENT OF THE RESISTANCE OFCIRCUITSIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.5TEMPERATURE-RISE TESTSIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.6SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENT TESTSIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 V20076.7VERIFICATION OF THE PROTECTIONIEEEC37.100.1Standard of Common Requirements for HighVoltage Power Switchgear Rated Above 1000 37.100.1IEEEC37.100.1IEEEC37.100.1Common Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 VCommon Requirements for High Voltage PowerSwitchgear Rated Above 1000 V20187.3.7.2POWER FREQUENCY VOLTAGE20187.3.7.3LIGHTNING IMPULSE VOLTAGE TESTS20187.3.10PARTIAL DISCHARGE TESTS20187.3.12VOLTAGE TEST AS CONDITION CHECK20187.5MEASUREMENT OF THE RESISTANCE OFCIRCUITS20187.6TEMPERATURE-RISE20187.7SHORT-TIME WITHSTAND CURRENT AND PEAKWITHSTAND CURRENT20187.8VERIFICATION OF THE PROTECTIONNEMAC37.54(2002)Indoor Alternating Current High-Voltage CircuitBreakers Applied as Removable Elements in MetalEnclosed Switchgear - Conformance TestProcedures20023.5LIGHTNING IMPULSE WITHSTAND VOLTAGETESTSNEMAC37.54(2002)Indoor Alternating Current High-Voltage CircuitBreakers Applied as Removable Elements in MetalEnclosed Switchgear - Conformance TestProcedures20023.6CONTINUOUS CURRENT CARRYING TESTSStandardNumber:Standard 20.9Metal-Enclosed Switchgear Rated 1 kV to 52 kVIncorporating Gas Insulating SystemsMetal-Enclosed Switchgear Rated 1 kV to 52 kVIncorporating Gas Insulating SystemsMetal-Enclosed Switchgear Rated 1 kV to 52 kVIncorporating Gas Insulating SystemsMetal-Enclosed Switchgear Rated 1 kV to 52 kVIncorporating Gas Insulating SystemsIEEEC37.100.120187.9TIGHTNESSPage 11 of 13

Project Number: SR5567548Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022/File Number: DA2443StandardNumber:Standard Title:Standard Edition(Amendment):Clause:Test method:NEMAC37.54(2002)Indoor Alternating Current High-Voltage CircuitBreakers Applied as Removable Elements in MetalEnclosed Switchgear - Conformance TestProcedures20023.7MECHANICAL ENDURANCE TESTSNEMAC37.54(2002)Indoor Alternating Current High-Voltage CircuitBreakers Applied as Removable Elements in MetalEnclosed Switchgear - Conformance TestProcedures20023.9SHORT TIME CURRENT CARRYING TESTSNEMAC37.54(2002)Indoor Alternating Current High-Voltage CircuitBreakers Applied as Removable Elements in MetalEnclosed Switchgear - Conformance TestProcedures20026.2POWER FREQUENCY WITHSTAND 55NEMAC37.55NEMAC37.55Switchgear - Medium Voltage Metal-CladAssemblies - Conformance Test ProceduresSwitchgear - Medium Voltage Metal-CladAssemblies - Conformance Test ProceduresSwitchgear - Medium Voltage Metal-CladAssemblies - Conformance Test ProceduresSwitchgear - Medium Voltage Metal-CladAssemblies - Conformance Test ProceduresSwitchgear - Medium Voltage Metal-CladAssemblies - Conformance Test ProceduresSwitchgear - Medium Voltage Metal-CladAssemblies - Conformance Test Procedures20025.5.2POWER-FREQUENCY WITHSTAND VOLTAGETESTS20025.5.3LIGHTNING IMPULSE WITHSTAND TESTS20025.6MECHANICAL PERFORMANCE TESTS20025.7CONTINUOUS CURRENT TEST20025.8SHORT-TIME WITHSTAND CURRENT TEST20025.9MOMENTARY WITHSTAND CURRENT TESTNEMAC37.55Medium-Voltage Metal-Clad SwitchgearAssemblies — Conformance Test Procedures20205.4Dielectric testsNEMAC37.55Medium-Voltage Metal-Clad SwitchgearAssemblies — Conformance Test Procedures20205.5Continous current testsNEMAC37.55Medium-Voltage Metal-Clad SwitchgearAssemblies — Conformance Test Procedures20205.6Momentary withstand current testsNEMAC37.55Medium-Voltage Metal-Clad SwitchgearAssemblies — Conformance Test Procedures20205.7Short-time withstand testsNEMAC37.55Medium-Voltage Metal-Clad SwitchgearAssemblies — Conformance Test Procedures20205.8Mechanical performance 37.57NEMAC37.57Metal-Enclosed Interrupter Switchgear Assemblies Conformance TestingMetal-Enclosed Interrupter Switchgear Assemblies Conformance TestingMetal-Enclosed Interrupter Switchgear Assemblies Conformance TestingMetal-Enclosed Interrupter Switchgear Assemblies Conformance TestingMetal-Enclosed Interrupter Switchgear Assemblies Conformance TestingMetal-Enclosed Interrupter Switchgear Assemblies Conformance TestingIndoor AC Medium-Voltage Switches for Use inMetal-Enclosed Switchgear - Conformance TestProcedures20034.5.2POWER-FREQUENCY WITHSTAND VOLTAGETESTS20034.5.3LIGHTNING-IMPULSE WITHSTAND TEST20034.6MECHANICAL PERFORMANCE TESTS20034.7CONTINUOUS CURRENT TEST20034.8SHORT-TIME WITHSTAND CURRENT TEST20034.9MOMENTARY WITHSTAND CURRENT TEST20034.5LIGHTNING IMPULSE WITHSTANDNEMAC37.58NEMAC37.58Indoor AC Medium-Voltage Switches for Use inMetal-Enclosed Switchgear - Conformance TestProcedures20034.6CONTINUOUS CURRENTNEMAC37.58Indoor AC Medium-Voltage Switches for Use inMetal-Enclosed Switchgear - Conformance TestProcedures20034.7.2MOMENTARY WITHSTAND CURRENT TESTNEMAC37.58Indoor AC Medium-Voltage Switches for Use inMetal-Enclosed Switchgear - Conformance TestProcedures20034.7.3SHORT-TIME WITHSTAND CURRENT TESTPage 12 of 13

Project Number: SR5567548Data Acceptance Program (DAP) Assessment Report/Assessment conducted on January 27, 2022/File Number: DA2443StandardNumber:Standard Title:Standard Edition(Amendment):Clause:Test method:NEMAC37.58Indoor AC Medium-Voltage Switches for Use inMetal-Enclosed Switchgear - Conformance TestProcedures20034.8MECHANICAL ENDURANCENEMAC37.58Switchgear—Indoor AC Medium-Voltage Switchesfor Use in Metal-Enclosed Switchgear—Conformance Test Procedures20204.5Dielectric TestNEMAC37.58Switchgear—Indoor AC Medium-Voltage Switchesfor Use in Metal-Enclosed Switchgear—Conformance Test Procedure20204.6Power Frequency Voltage TestNEMAC37.58Switchgear—Indoor AC Medium-Voltage Switchesfor Use in Metal-Enclosed Switchgear—Conformance Test Procedure20204.7Lightning Impulse Withstand TestNEMAC37.58Switchgear—Indoor AC Medium-Voltage Switchesfor Use in Metal-Enclosed Switchgear—Conformance Test Procedure20204.8Temparture-Rise TestNEMAC37.58Switchgear—Indoor AC Medium-Voltage Switchesfor Use in Metal-Enclosed Switchgear—Conformance Test Procedure20204.9Short-Time Withstand Current and Peak WithstandCurrent (Formerly Momentary) TestsNEMAC37.58Switchgear—Indoor AC Medium-Voltage Switchesfor Use in Metal-Enclosed Switchgear—Conformance Test Procedure20204.10Mechanical Endurance TestPage 13 of 13

High-Voltage Isolating Switches 2 6.3 DIELECTRIC STRENGTH CSA-C22.2 No. 58 High-Voltage Isolating Switches 2 6.4 IMPULSE AND CORONA EXTINCTION CSA-C22.2 . FULL-WAVE LIGHTNING IMPULSE WITHSTAND VOLTAGE IEEE C37.09 Standard Test Procedures for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V 2018 4.13 MECHANICAL .