59sc5a-14pd Pds915sa-15 Ss-pg95sas-15

Transcription

PG95SASCONDENSING GAS FURNACEProduct DataSTANDARD FEATURESS Heating efficiency up to 96.0% AFUE.S Direct vent/sealed combustion, single--pipe venting or ventilatedcombustion air.S 4--way multipoise furnace.S Hot surface ignition.S Direct-vent/sealed combustion, single-pipe venting or ventilatedcombustion air.S PSC blower motor.S LED diagnostics with self test feature.S Stores fault codes during power outages.S Approved for Twinning applications (42060 through 60120sizes, only).S Approved for Manufactured Housing/Mobile Home applications(except 26,000 and 140,000 Btuh input) with MH accessory kit.S Adjustable heating air temperature rise.S Adjustable cooling airflow.S Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet airleakage less than 1.4% at 0.5 in. W.C. when tested in accordancewith ASHRAE standard 193.A11300The model PG95SAS is an efficient and robust 4--way multipoisecondensing furnace with features including single--stage heatingand a rugged PSC blower motor. The PG95SAS builds on themany Payne successes in the furnace industry and establishes anew standard for all high--efficiency gas furnaces. Low NOx unitsare designed for California installations and meet 40 ng/J NOxemissions. Can be installed in air quality management districts witha 40 ng/J NOx emissions requirement.Use of the AHRI Certified TM Mark indicates amanufacturer’s participation in the program. Forverification of certification for individual products,go to www.ahridirectory.org.1CERTIFIED

RATEDHEATINGCASINGDIMENSIONS (IN.) OUTPUT†SAP 4.4%NoneNoneNoneNoneNoneNoneNoneNoneNoneHEATING AIRFLOWHEATINGESP(in. 100.2016800.2022450.2021750.20COOLINGCFM@ 0.5 ESP(in. W.C.)440-775625-905650-1420810-16001335-1970915--- 15451345--- 20651320-21051290--- 2035MOTOR HPSPEED TAPS1/4 - 41/2 - 41/2 - 53/4 - 51-51/2 - 41-51-51-5† Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.PG95SAS‡ Heating CFM at factory default blower motor heating tap settings.ESP --- External Static PressureFEATURES AND BENEFITSHYBRID HEATR Dual Fuel system — This system can providemore control over your monthly energy bills by automaticallyselecting the most economical method of heating. With HYBRIDHEAT components, our system automatically switches between thegas furnace and the single--stage electric heat pump as outsidetemperatures change to maintain greater efficiency and comfortthan with any traditional single-source heating system. The heatpump also delivers high-efficiency cooling in the summer.Robust Igniter — Payne’s unique SiN igniter is not onlyphysically robust but it is also electrically robust. It is capable ofrunning at line voltage and does not require complex voltageregulators as do other brands. This unique feature further enhancesthe gas furnace reliability and continues Payne’s tradition oftechnology leadership and innovation in providing a reliable anddurable product.Reliable Heat Exchanger Design — The aluminized steel, clamshell primary heat exchanger was re--engineered to achieve greaterefficiency out of a smaller size. The first two passes of the heatexchanger are based on the current 80% product, a design withmore than ten years of field-proven performance and success.These innovations, paired with the continuation of a crimped,no-weld seam create an efficient, robust design for this essentialcomponent.The condensing heat exchanger, a stainless steel fin and tubedesign, is positioned in the furnace to extract additional heat.Stainless steel coupling box componentry between heat exchangershas exceptional corrosion resistance in both natural gas andpropane applications.4-Way Multipoise Design — One model for all applications –there is no need to stock special downflow or horizontal modelswhen one unit will do it all. The new heat exchanger design allowsthese units to achieve the certified AFUE in all positions.Direct or Single-pipe Venting, or Optional VentilatedCombustion Air — All sizes except the 26,000 BTUH model canbe vented for direct vent/two-pipe, ventilated combustion air, orsingle-pipe applications. The 26,000 BTUH model can use thesame 2--pipe venting system using outside air for combustion, butis not considered direct--vent. This provides added flexibility tomeet diverse installation needs.Sealed Combustion System — This furnace brings in combustionair from outside the furnace, which results in especially quietoperation. By sealing the entire combustion vestibule, the entirefurnace can be made quieter, not just the burners.Monoport Burners — The burners are specially designed andfinely tuned for smooth, quiet combustion and economicaloperation.Bottom Closure — Factory-installed for side return; easilyremovable for bottom return. The multi-use bottom closure canalso serve for roll-out protection in horizontal applications, and actas the bottom closure for the optional return air base accessory.Quality Registration — Our furnaces are engineered andmanufactured under an ISO 9001 registered quality system.Certifications — This furnace is CSA (AGA and CGA) designcertified for use with natural and propane gases. The furnace isfactory--shipped for use with natural gas. A CSA listed gasconversion kit is required to convert furnace for use with propanegas. The efficiency is AHRI efficiency rating certified. This furnacemeets California Air Quality Management District emissionrequirements.2

SPECIFICATIONSThe furnace should be sized to provide 100 percent of the designheating load requirement plus any margin that occurs because offurnace model size capacity increments. None of the furnacemodel sizes can be used if the heating load is 12,000 BTUH orlower. Use Air Conditioning Contractors of America (Manual Jand S); American Society of Heating, Refrigerating, andAir-Conditioning Engineers; or other approved 97,000117,000135,00040 - 70(22 - 39)45 - 75(25 - .1114.1511 x 11511 x )14.919.61229(8.8)20202060120601406716015525 - 5540 - 7040 - 7040 - 7040 - 7040 - 7040 - 70(14 - 31) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39)Airflow Capacity and Blower DataHeatingRated External StaticPressure (in. W.C.)CoolingHigh HeatAirflow Delivery@ Rated ESP (CFM)Cooling400 CFM/tonCooling Capacity (tons)350 CFM/tonDirect-Drive Motor TypeDirect-Drive Motor HPMotor Full Load AmpsRPM RangeSpeed SelectionsBlower Wheel Dia x Widthin.Air Filtration SystemFilter Used for Certified Watt 6545454.55.54.56Permanent Split Capacitor (PSC)0.7510.517.913.86.513.8500 -1150554511 x 811 x 10 11 x 10 11 x 10Field SuppliedKGAWF**06UFR0.252.80.56.20.56.8411 x 7411 x 7511 x 8Electrical DataInput VoltageVolts-Hertz-PhaseOperating Voltage RangeMin-MaxMaximum Input AmpsAmpsUnit AmpacityAmpsMinimum Wire SizeAWGFeetMaximum Wire Length@ Minimum Wire Size(M)Maximum Fuse/Ckt Bkr(Time-Delay Type RecomAmpsmended)Transformer Capacity (24vac output)HeatingExternal Control (8.5)15151515ControlsGas Connection SizeBurners (Monoport)Gas Valve (Redundant)ManufacturerMinimum Inlet Gas pressure (in. W.C.)Maximum Inlet Gas pressure (in. W.C.)Ignition DeviceLimit ControlHeating Blower Control (Heating Off-Delay)Cooling Blower Control (Time Delay Relay)Communication SystemThermostat ConnectionsAccessory -12714.57.619.110.412143035(9.1)(10.7)201540 VA27.9 VA34.6 VA420606008042100601001/2" - NPT34455White Rogers4.513.6Silicon Nitride180170200180180Adjustable: 90, 120, 150, 180 seconds90 secondsnoneCom 24V, R, W, G, YEAC (115vac); HUM (24vac)* See Accessory List for part numbers available.348080PG95SASHeating Capacity and ertified TemperatureHigh HeatRise Range ºF (ºC)method to calculate heating load estimates and select the furnace.Excessive oversizing of the furnace may cause the furnace and/orvent to fail prematurely, customer discomfort and/or vent freezing.Failure to follow these guidelines is considered faulty installationand/or misapplication of the furnace; and resulting failure, damage,or repairs may impact warranty coverage.

MODEL NUMBER NOMENCLATURE1BrandP 2ProductG 3-4Base Effy.95 5Voltage/MotorS 6Major SeriesA 7Htg. StagesS 8-9Motor30 10 - 12Htg. Cap.040 13Width/VariationA 14Minor SeriesA BrandVariationsA - 14.2"B - 17.5"C - 21.0"F - 24.5"Product0 - 90 AFUE2 - 92 AFUE3 - 93 AFUE5 - 95 AFUE6 - 96 AFUE7 - 97 AFUES - Std./PSCX- High Eff.V - Variable SpeedMajor SeriesPG95SAS15 - 16VariationsAA 24 - 800 CFM30 - 1000 CFM36 - 1200 CFM42 - 1400 CFM48 - 1600 CFM54 - 1800 CFM60 - 2000 CFM66 - 2200 CFMT- Two-stageS - Single-stageMinor Series026 26,000 BTU040 40,000 BTU060 60,000 BTU080 80,000 BTU100 100,000BTU120 120,000 BTU140 140,000 BTUA180004For California Residents:For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to amitigation fee of up to 450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.comFURNACE COMPONENTSGAS BURNERHOT SURFACEIGNITERMANUAL RESETROLLOUT SWITCHFLAMESENSORMANUAL RESETROLLOUT SWITCHGAS VALVEMAIN LIMIT SWITCH(BEHIND GAS VALVE)OPERATING INSTRUCTIONSNOT SHOWN (LOCATED ONMAIN FURNACE DOOR, SEEOPERATING INSTRUCTIONSINSIDE DOOR FIGURE).INDUCER MOTORASSEMBLYELECTRICAL JUNCTIONBOX (IF REQUIRED,LOCATION MAY VARY)BLOWER DOORSAFETY SWITCHBLOWER ANDMOTORFURNACECONTROLBOARDCAPACITOR/POWER CHOKERATING PLATE NOT SHOWN(LOCATED ON BLOWER DOOR)REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.A1701274

ACCESSORIESPART 201CFPKGAAD0110PVCKGACK0101HCKP908 DDDDDDDDDDDDDDDDDDDDDDDDDSee Venting TablesSee Venting TablesDDDDDDDDDAll 2 ---Pipe 5” IAQ DevicesKGAAD0201MEC24”x25” IAQ 32DB206LH32DB209LH32DB21092 e with EZXCAB---1016Use with EZXCAB---1020Use with EZXCAB---1024Use with EZXCAB---1016Use with EZXCAB---1020Use with EZXCAB---1024Use with FILCABXL ---1016Use with FILCABXL ---1020Use with FILCABXL ---1024DDDDDDDDDDDDDDPG95SASDESCRIPTIONVenting AccessoriesVent Kit - Through the CabinetVent Terminal - Concentric - 2” (51 mm)Vent Terminal - Concentric - 3” (76 mm)Vent Terminal Bracket - 2” (51 mm)Vent Terminal Bracket - 3” (76 mm)Vent Kit --- Rubber CouplingCondensate Drainage AccessoriesFreeze Protect Kit - Condensate Drain Line TapeFreeze Protect Kit - Condensate Trap with Heat PadCPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVCHorizontal Trap Grommet - Direct VentCondensate Neutralizer KitExternal Trap KitDuctwork Adapter AccessoriesFurnace Base Kit for Combustible FloorsCoil Adapter Kits --- No OffsetCoil Adapter Kits --- Single OffsetCoil Adapter Kits --- Double OffsetReturn Air Base (Upflow Applications) 14.0 ---in. wideReturn Air Base (Upflow Applications) 17.5 ---in. wideReturn Air Base (Upflow Applications) 21.0 ---in. wideReturn Air Base (Upflow Applications) 24.5 ---in. wideIAQ Device Duct Adapters 20.0 ---in. IAQ to 16 in. SideReturnIAQ Device Duct Adapters 24.0 ---in. IAQ to 16 in. SideReturnGas Conversion AccessoriesMobile Home KitGas Conversion Kit - Nat to LPGas Conversion Kit - LP to NatGas Conversion Kit - Nat to LPGas Conversion Kit - LP to NatGas Orifice Kit - #42 (Nat Gas)Gas Orifice Kit - #43 (Nat Gas)Gas Orifice Kit - #44 (Nat Gas)Gas Orifice Kit - #45 (Nat Gas)Gas Orifice Kit - #46 (Nat Gas)Gas Orifice Kit - #47 (Nat Gas)Gas Orifice Kit - #48 (Nat Gas)Gas Orifice Kit - #54 (LP)Gas Orifice Kit - #55 (LP)Gas Orifice Kit - #56 (LP)Gas Orifice Kit - 1.25mm (LP)Gas Orifice Kit - 1.30mm (LP)Gas Valve AdapterGas Valve Tower Port Adapter KitControl AccessoriesTwinning KitIAQ AccessoriesFilter Rack --- Bottom Return for 1” Filters --- 14.2” wideFilter Rack --- Bottom Return for 1” Filters --- 17.5” wideFilter Rack --- Bottom Return for 1” Filters --- 21.0” wideFilter Rack --- Bottom Return for 1” Filters --- 24.5” wideFilter Pack (6 pack) --- Washable - 16x25x1Filter Pack (6 pack) --- Washable - 24x25x1EZ-Flex Filter - 16” (406 mm)EZ-Flex Filter - 20” (508 mm)EZ-Flex Filter - 24” (610 mm)EZ-Flex Filter with End Caps - 16” (406 mm)EZ-Flex Filter with End Caps - 20” (508 mm)EZ-Flex Filter with End Caps - 24” (610 mm)Cartridge Media Filter - 16” (406 mm)Cartridge Media Filter - 20” (508 mm)Cartridge Media Filter - 24” (610 mm)EZ Flex Cabinet Side or Bottom Return 4” Filters --- 16”EZ Flex Cabinet Side or Bottom Return 4” Filters --- 20”EZ Flex Cabinet Side or Bottom Return 4” Filters --- 24”D Used with the model furnace

AIR DELIVERY - CFM (BOTTOM RETURN WITH FILTER)PG95SASUNIT TTOM orTWO-SIDES 3,4042100SIDE/BOTTOM060100BOTTOM orTWO-SIDES 3,4060120BOTTOM orTWO-SIDES 3,4060140BOTTOM orTWO-SIDES 3,4SPEEDTAPS 2BlackYellowBlueRed 5BlackYellowBlueRedBlackYellowOrangeBlueRed 5BlackYellowOrangeBlueRed 5BlackYellowOrangeBlueRedBlackBlueYellow 5Red 5BlackYellowOrangeBlueRedBlackBlueYellowOrange 5Red 5BlackBlueYellow 5Orange 5Red 138523252175172514951345EXTERNAL STATIC PRESSURE (IN. W.C.) :1. A filter is required for each return ---air inlet. Airflow performance includes a 3/4 ---in. (19 mm) washable filter media such as contained in a factory ---authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external staticpressure.2. Blower speed taps are not always in the same order. Factory default blower connections are as follows:a. Heating airflow --- BLUE (also used for Continuous Fan)b. Cooling airflow --- BLACK (enabled when the Y terminal is energized)ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION.3. Airflows over 1800 CFM require bottom return, two ---side return, or bottom and side return. A minimum filter size of 20” x 25” (508 x 635 mm) is required.4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.5. Highlighted areas indicate that this airflow range is below the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE USED FOR COOLING.6. All airflows that are shown in BOLD exceed 0.58 watts per CFM at the given external static pressure.7. The “ ---” entry indicates an unstable operating condition.6

MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS IN UNCONDITIONED SPACE -- FT.WinterDesignTemp FPipe Dia.In.200-20-40Unit SizeWinterDesignTemp FPipe Dia.in.200-20-40Pipe 20155025151040,000* BTUHUninsulatedPipe Dia.in.200-20-40Unit SizeWinterDesignTemp FPipe Dia.in.200-20-403/8-in. Insulation60,000 BTUH3/8-in. InsulationUninsulated1/2-in. Insulation1/2-in. 000 BTUH3/8-in. InsulationUninsulated1/2-in. 1551515151550504030705030257040252070351510Unit SizeWinterDesignTemp F1/2" Insulation1½Unit SizeWinterDesignTemp F26,000* BTUH3/8" Insulation0" Insulation100,000 BTUH3/8-in. InsulationUninsulated1/2-in. 10555352590452515120,000 BTUHUninsulated3/8-in. Insulation140,000 BTUH3/8-in. InsulationUninsulated1/2-in. Insulation1/2-in. 56550351256040257PG95SASUnit Size

MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS IN UNCONDITIONED SPACE -METERSUnit SizeWinterDesignTemp CPipe Dia.mm-7-18-29-40Unit SizePG95SASWinterDesignTemp CPipe Dia.mm-7-18-29-40Pipe .013.76.13.01.518.39.16.14.615.27.64.63.040,000* BTUHUninsulatedPipe Dia.mm-7-18-29-40Unit SizeWinterDesignTemp CPipe Dia.mm-7-18-29-403/8-in. Insulation1/2-in. 4.6516415.2 13.77.66.14.63.03.01.56.16.16.14.65160,000 BTUH3/8-in. InsulationUninsulated6418.3 1.59.13.07.63.06.16.16.16.151641/2-in. Insulation7622.9 19.8 18.312.2 9.17.67.66.14.64.64.63.080,000 BTUH3/8-in. InsulationUninsulated38516.16.16.16.1647625.9 22.9 19.813.7 12.2 9.19.17.66.16.14.63.01/2-in. 21.312.27.66.121.310.74.63.0Unit SizeWinterDesignTemp C1/2" Insulation38Unit SizeWinterDesignTemp C26,000* BTUH3/8" Insulation0" Insulation100,000 BTUH3/8-in. InsulationUninsulated1/2-in. 19.813.79.132.016.710.77.627.413.77.64.6120,000 BTUHUninsulated3/8-in. Insulation1/2-in. InsulationUninsulated140,000 BTUH3/8-in. Insulation1/2-in. 51.519.819.815.23538.118.312.27.68

MAXIMUM EQUIVALENT VENT LENGTHSTable 1 – Maximum Equivalent Vent Length -- Ft.NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.Unit SizePipe Dia.(mm)0--- 610611--- 914915--- 1219Altitude 1220--- 1370(meters) 1371--- 15241525--- 18291830--- 21342135--- 24382439--- 27432744--- 304826,000 240,000 160,000 40351451351201102015309551026,000 45135125N/A551051151054510011520161540,000 ximum Equivalent Vent Length --- Meters60,000 5.213.710.69.17.64.53.0NOTES:1. Inducer Outlet Restrictor disk (P/N 337683 ---401; 1.25 ---in. (32 mm) Dia.) shipped in the loose parts bag or available through Replacement Componentsrequired under 10 ---ft. (3 M) TEVL in all orientations. Required for installations from 0 --- 2000 (0 to 610 M) above sea level. Failure to use an outlet restrictor may result in flame disturbances or flame sense lock ---out.2. Inducer Outlet Restrictor disk (P/N 337683 ---401; 1.25 ---in. (32 mm) Dia.) shipped in the loose parts bag or available through Replacement Componentsrequired for no greater than 5 ---ft. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 --- 2000 (0 to 610 M) abovesea level.VENT TERMINAL CONFIGURATIONSELBOW CONFIGURATIONSConcentricLongMediumMiteredStandard 2-in., 3-in., oroptional 4-in. termination.A13110Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)Pipe Diameter (in):Mitered 90º ElbowMedium Radius 90º ElbowLong Radius 90º ElbowMitered 45º ElbowMedium Radius 45º ElbowLong Radius 45º 0.5)(4.9)85342.51.516NOTES:1.2.3.4.5.6.7.8.Use only the smallest diameter pipe possible for venting. Over ---sizing may cause flame disturbance or excessive vent terminal icing or freeze ---up.NA --- Not allowed. Pressure switch will not close, or flame disturbance may result.Vent sizing for Canadian installations over 4500 ft. (1370 M) above sea level are subject to acceptance by the local authorities having jurisdiction.Size both the combustion air and vent pipe independently, then use the larger size for both pipes.Assume the two 45 elbows equal one 90 elbow. Wide radius elbows are desirable and may be required in some cases.Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all applications.Use 3 ---in. (76 mm) diameter vent termination kit for installations requiring 4 ---in. (102 mm) diameter it SizePipe Dia.(in)0--- 20002001--- 30003001--- 40004001--- 4500Altitude 4501--- 5000(feet)5001--- 60006001--- 70007001--- 80008001--- 90009001--- 10000

Venting System Length CalculationsThe Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalentlength of elbows used in the venting system from Table 2.Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that onefoot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Table 1.Example 1PG95SASA direct-vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE:70 feet (22 M) of vent pipe, 65 feet (20 M) of combustion air inlet pipe, (3) 90º long-radius elbows, (2) 45º long-radius elbows, and a factoryaccessory concentric vent kit.Can this application use 2” (50 mm ND) PVC/ABS DWV vent piping?Measure the required linear length of air inlet andvent pipe; insert the longest of the two hereAdd equiv length of (3) 90º long-radius elbows(use the highest number of elbows for either thevent or inlet pipe)Add equiv length of (2) 45º long-radius elbows(use the highest number of elbows for either thevent or inlet pipe)Add equiv length of factory concentric vent term70 ft.(22 M)Use length of the longer of the ventor air inlet piping system3x3 ft.(0.9 M) 9 ft.(2.7 M)From Table 22x1.5 ft.(0.5 M) 3 ft.(0.9 M)From Table 20 ft.Add correction for flexible vent pipe, if any0 ft.82 ft.(25 M)Total Equivalent Vent Length (TEVL)95 ft.(29 M)YESMaximum Equivalent Vent Length (MEVL)Is TEVL less than MEVL?From Table 2From Vent Manufacturer’sinstructions; zero for PVC/ABS DWVAdd all of the above linesFor 2” pipe from Table 1Therefore, 2” pipe MAY be usedExample 2A direct-vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE:100 feet (30 M) of vent pipe, 95 feet (29 M) of combustion air inlet pipe, (3) 90º long-radius elbows, and a polypropylene concentric vent kit.Also includes 20 feet (6.1 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.VERIFY FROM POLYPROPYLENE VENT MANUFACTURER’S INSTRUCTIONS for the multiplier correction for flexible vent pipe.Can this application use 60mm o.d. (2”) polypropylene vent piping? If not, what size piping can be used?Measure the required linear length of RIGID air inlet and vent pipe; insertthe longest of the two here: 100 ft. Of rigid pipe --- 20 ft. Of flexible pipeAdd equiv length of (3) 90º long-radius elbows5 ft.(use the highest number of elbows for either the3x(1.5 M)vent or inlet pipe)Add equiv length of 45º long-radius elbows(use the highest number of elbows for either thevent or inlet pipe)0Add equiv length of factory concentric vent term9x 80 ft.(24 M) 15 ft.(4.6 M) 0 ft.(0 M)Use length of the longer of the ventor air inlet piping systemExample from polypropylene ventmanufacturer’s instructions, Verify from ventmanufacturer’s instructions.3.3 ft30 ft. (0.9 M)(9 M)20 ft.40 ft.Add correction for flexible vent pipe, if any2*x (6.1 M)(12.2 M)* VERIFY FROM VENT MANUFACTURER’S INSTRUCTIONS; For example only, assume 1 meter of flexible 60mm (2”) or 80mm (3”)polypropylene pipe equals 2.0 meters (6.5 ft.) of PVC/ABS pipe.165 ft.Total Equivalent Vent Length (TEVL)Add all of the above lines(50 M)x95 ft.(29 M)Maximum Equivalent Vent Length (MEVL)Is TEVL less than MEVL?NO185 ft.(57 M)YESMaximum Equivalent Vent Length (MEVL)Is TEVL less than MEVL?10For 2” pipe from Table 1Therefore, 60mm (2”) pipe may NOT beused; try 80mm (3”)For 3” pipe from Table 1Therefore, 80mm (3”) pipe MAY be used

RETURN AIR TEMPERATUREThis furnace is designed for continuous return--air minimum temperature of 60 F (15 C) db or intermittent operation down to 55 F (13 C)db such as when used with a night setback thermometer. Return--air temperature must not exceed 80 F (27 C) db. Failure to follow thesereturn air limits may affect reliability of heat exchangers, motors and controls.80/ 27 C60/ 16 CPG95SASSUPPLY AIRA10490MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALSPOSITIONRearFront (Combustion air openings in furnace and in structure)Required for service**All Sides of Supply Plenum**SidesVentTop of FurnaceCLEARANCE0 (0 mm)1 in. (25 mm)24 in. (610 mm)*1 in. (25 mm)0 (0 mm)0 (0 mm)1 in. (25 mm)* Recommended**Consult your local building codesCOMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATIONFIELD-SUPPLIED2-IN. (51 mm) DIA.MITERED RADIUSPVC 90 ELBOWFIELD-SUPPLIED2-IN. (51 mm) DIA.PVC PIPE12” (300 mm) MINIMUMA12376NOTE: See Installation Instructions for specific venting configurations.11

DOWNFLOW SUBBASELOCATINGTAB1 1/4-IN. ssembledDisassembledDIMENSIONS (IN.

Combustion Air— All sizes except the 26,000 BTUH model can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. The 26,000 BTUH model can use the same 2--pipe venting system using outside air for combustion, but is not considered direct--vent. This provides added flexibility to meet diverse installation .