Gettingfewer refractivesurprises.ZEISS IOLMaster 700www.zeiss.com/us/iolmaster700

20 years of biometryIOLMaster 700 from ZEISS with SWEPT Source Biometry builds upon 20 years of experience in optical biometry –far longer than any other device.Its latest software update features Central Topography formore insights on corneal shape, and allows you to accessbiometry data on your mobile device with EQ Mobile fromZEISS. Once again, ZEISS IOLMaster 700 demonstratesits technological leadership.Defining biometry for 20 years.

NEWCentral Topography:starting your workflowwith more insightsGain additional information and detect visually relevant asymmetries on centralcorneal shape with your usual ZEISS IOLMaster 700 measurement: posterior and anterior refractivepowers taken into account no additional hardware needed easy and intuitive reading of centralcorneal shape information scaling and hues developed in no extra measurement, no extra timecooperation with Douglas D. Koch no changes to the current workflowand Li Wang, MD, USAI am amazed at how much information we get from Central Topography.Douglas D. Koch, MD, USAAgainst-the-rule astigmatism on CentralTopography*Irregular astigmatism on Central Topography*Central steep cornea on Central Topography*(patient with previous hyperopic LASIK/PRK)*Interpretation by Douglas D. Koch, M.D., USA3

CONNECTIVITYStreamlining your refractive cataract workflowVERACITY Surgical, EQ Workplace and EQ Mobile from ZEISSSave time in pre-operative planning, increase current case capacity and conversion rates to advanced IOLsand reduce the risk of human errors.ZEISS VERACITY Surgical – less time planning, more time treatingVERACITY Surgical from ZEISS increases workflow efficiency by integrating patient data from Electronic Health Records (EHR)and diagnostic hardware, including ZEISS IOLMaster 700, for automated surgical planning you can access from anywhere.Each personalized cataract surgery plan incorporates patient medical history (including safety concerns), patient ocularmeasurements, physician preferences and patient lifestyle and expectations, so you can put your focus where it belongs—delivering the quality of care your patients expect.ZEISS EQ Workplace – from IOL calculation to surgical planningEQ Workplace from ZEISS—fully integrated with FORUM from ZEISS—supports the review and analysis of your biometryand diagnostic data, all from one place, for an informed treatment decision. It allows for remote IOL calculation and selection,IOL ordering and surgical planning for CALLISTO eye from ZEISS. It also enables personalized IOL constants to help improveefficiency and safety and streamline your workflow.ZEISS EQ Mobile – your reports anytime, anywhereWith the latest ZEISS IOLMaster 700 software you can send your biometry data and scleral reference images via the ZEISS EQMobile cloud to ZEISS CALLISTO eye for computer-assisted surgery. All your data is accessible in the ZEISS EQ Mobile app onyour iPhone or iPad. This is particularly useful if you practice at different sites.4

CONNECTIVITYMarkerless toric IOL implantationDuring routine biometry, ZEISS IOLMaster 700 will acquire a reference image in case of astigmatism.The image of the eye is acquired during the keratometry measurement – all with one device.Both reference image and keratometry data can be transferred to ZEISS CALLISTO eye, e.g. togetherwith your surgical planning from ZEISS VERACITY Surgical. Each personalized cataract surgical plan,incorporates patient medical history (including safety concerns), patient ocular measurements andyour physician preferences. During surgery, the image is then used for intraoperative matchingwith the live eye image. All data needed is displayed in the eyepiece of the surgical microscopesOPMI LUMERA or ARTEVO 800 from ZEISS. Preoperative corneal marking and additionalmeasurements for toric IOL alignment thus become obsolete.Efficiency in the palm of your handZEISS Cataract Suite – designed to work together.5

ONLY FROM ZEISSGetting fewer refractive surprisesTotal Keratometry – replacing assumptions with measurementsFeaturing Total Keratometry (TK ), ZEISS IOLMaster 700 allows you to directly measure the posterior corneal surface usingSWEPT Source OCT. Total Keratometry can be used in classic IOL calculation formulas – no need for a second device, third-partysoftware or an online calculator.In addition, Graham Barrett has developed three formulas exclusively for Total Keratometry: Barrett TK Universal II,Barrett TK Toric and Barrett True K with TK.Percentages of eyes within 0.50 D, 0.75 D and 1.00 D ofrefractive prediction error in previously myopic eyes6383750.50 DTrue K6900.75 D90 951.00 DTrue K with TKIn post-myopic LASIK eyes Barrett True K formulawith TK improved the outcome predictioncompared to the Barrett True K with Classic Kswithin 0.5 D by 12 % (p 0.04)1

Detect unusual eye geometriesThe patented Cornea-to-Retina Scanof ZEISS IOLMaster 700 showsanatomical details on a longitudinalcut through the entire eye. Thus,unusual eye geometries such as tiltor decentration of the crystalline lenscan be detected. If left undetected,such critical details can lead to anunsatisfactory post-operative visualexperience.Suspected tilted lens*Detect poor fixationThe unique Fixation Check provides youwith more confidence in biometry. Canyou see the foveal pit? If so, you canreduce the risk of refractive surprisesdue to incorrect measurements causedby undetected poor fixation. If not,educate your patients to always fixateon the target.Poor fixation*Correct fixation*Visually verify your measurementAll measurement calipers are shownon the patented Cornea-to-Retina Scanallowing you to visually verify whatstructure has been measured.The complex interpretation of A-scansis no longer necessary and potentialsources of error can thus be eliminated.Benefit from the integratedBarrett SuiteThe Barrett Universal II, True K andToric formulas are integrated into onesuite. The directly measured posteriorsurface can be considered by choosingTotal Keratometry for all three formulas.* Image courtesy of Prof. W. Sekundo,Philipps University Hospital Marburg, Germany7

HIGHLIGHTSOptimizing your workflowFast and easy to useMeasure both eyes in less than45 seconds, thanks to SWEPT SourceBiometry. 2 Alignment assistancefunctions make the results largelyindependent of the user and thereforeeasy to delegate.Multi-touch screenUp to 99 % cataract penetration rateA comparative clinical study withmore than 1,200 eyes showed thatZEISS IOLMaster 700 achieves a cataractpenetration rate up to 99 %. As aresult, the number of ultrasound casescan be reduced by 92 %, saving youvaluable time.3Very dense cataract that was measured successfully** Image courtesy of Prof. M. de La Torre, DLT Ophthalmic Center, Peru8

HIGHLIGHTSOutstanding repeatabilityRepeatability is essential for goodrefractive outcomes. Thanks to itsunique SWEPT Source Biometrywith 2,000 scans per second, therepeatability of the ZEISS IOLMaster 700is absolutely outstanding.In-vivo repeatability in μmImproving your refractive outcomes40303525201050LENSTAR LS900IOLMaster 500IOLMaster 700Comparison of the repeatability of axial length measurement 4Broad IOL constants databaseGet the latest optimized lens constantsfrom the new IOLCon5 database to helpyou improve your refractive outcomes.As it incorporates the data from theGroup of Laser Interference Biometry(ULIB) database you find optimized IOLconstants for more than 300 IOLmodels that were collected exclusivelyfor the ZEISS IOLMaster. The data canbe imported by simply using a USB stick.9

SERVICEBenefit from the experienced ZEISS supportSupport whenever you need itSmart investment –IOL power calculation serviceThe ZEISS OPTIME service packagesfinancing with ZEISSOur team of experts supports you withavailable for the ZEISS IOLMaster 700Whether you want to start your ownZEISS IOL calculations. They provideset new industry standards. Theypractice, fuel expansion or diversifyeasy-to-read calculation results withsupport outstanding system availabilityservices, tight budgets are an issuecomments and IOL suggestions. Thisover the long term with the backing ofalmost everywhere these days. At ZEISS,service is particularly useful for casesdedicated and reliable assistance fromwe can offer you financial solutionswith corneal pathologies or when thean experienced and trusted partner.tailored to your specific needs. ZEISSbiometry is outside of the normal range.financing options cover traditionalmeans of financing medical equipmentwith leasing contracts and customizedfull-service contracts.10

Technical dataZEISS IOLMaster 700Measurement rangeAxial length 14 – 38 mmCorneal radii 5 – 11 mmAnterior chamber depth 0.7 – 8 mmLens thickness 1 – 10 mm (phakic eye)0.13 – 2.5 mm (pseudophakic eye)Central corneal thickness 0.2 – 1.2 mmWhite-to-white 8 – 16 mmDisplay scalingAxial length 0.01 mmCorneal radii 0.01 mmAnterior chamber depth 0.01 mmLens thickness 0.01 mmCentral corneal thickness 1 µmWhite-to-white 0.1 mmSD of repeatability6Axial length 5 µmCorneal radii 0.09 DCylinder 0.75 D, axis 3.8 Anterior chamber depth 7 µmLens thickness 6 µmCentral corneal thickness 2.5 µmWhite-to-white 111 µmIOL calculation formulas Barrett Suite: Barrett Universal II & Barrett TK Universal II*, Barrett toric & Barrett TK toric*,Barrett True K & Barrett True K with TK Haigis Suite: Haigis, Haigis-L, Haigis-T Hoffer Q Holladay 1 and 2 SRK /TInterfacesZEISS VERACITY SurgicalZEISS EQ WorkplaceZEISS EQ MobileZEISS FORUM eye care data management systemZEISS computer-assisted cataract surgery system CALLISTO eye (via USB & FORUM)Data interface for electronic medical record (EMR) / patient management systems (PMS), Holladay IOLConsultant software and PhacoOptics Data export to USB storage mediaEthernet port for network connection and network printerLine voltage100 – 240 V 10 %Line frequency50 – 60 HzPower consumptionmax. 150 VALaser class1* Only available with Total Keratometry license123456Lawless, M. et al., “Total Keratometry in interocular lens power calculation in eyes with previous laser refractive surgery” Clin Exp Ophthalmol. 2020 Apr 12.Depending on experience of operator and eye conditions.R. Varsits, N. Hirnschall, B. Doeller, O. Findl; Increasing the number of successful axial eye length measurements using swept-source optical coherence tomographytechnology compared to conventional optical biometry; presented at ESCSR 2016.Sources: LENSTAR LS900, HS-Art.No. 1511.7220032.02060, standard deviation (1,σ); IOLMaster 500, Vogel A, Dick B, Krummenauer F:Reproducibility of optical biometry using partial coherence interferometry. Intraobserver and Interobserver reliability. J Cataract Refract Surg, 27: 1961–1968, 2001standard deviation (1,σ); IOLMaster 700 see technical data.Access via https://iolcon.orgCarl Zeiss Meditec, clinical trial, IOLMaster 700-2015-111

IOLMaster 700CALLISTO eyeOPMI LUMERAARTEVO 800EQ WorkplaceCarl Zeiss Meditec AGGoeschwitzer Strasse 51–5207745 /med/contactsCAP-en-US 32 020 0003I CZ-VII/2021 United States edition: Only for sale in selected countries.The contents of the brochure may differ from the current status of approval of the product or service offering in your country. Please contact ourregional representatives for more information. Subject to changes in design and scope of delivery and due to ongoing technical development.IOLMaster, FORUM, VERACITY Surgical, EQ Workplace, EQ Mobile, LUMERA and CALLISTO eye are registered trademarks of Carl Zeiss Meditec AGor other companies of the ZEISS Group in Germany and/or other countries. Carl Zeiss Meditec USA, Inc., 2021. All rights reserved.0297Carl Zeiss Meditec USA, Inc.5300 Central ParkwayDublin, CA 94568USAwww.zeiss.com/us/iolmaster700

Comparison of the repeatability of axial length measurement 4 Broad IOL constants database Get the latest optimized lens constants from the new IOLCon5 database to help you improve your refractive outcomes. As it incorporates the data from the Group of Laser Interference Biometry (ULIB) database you find optimized IOL constants for more than .