Elevator Car Air PurifierProduct SpecificationALPHATCH DISINFECTION SERVICES INC.1

Thanks for choosing “Alphatch” brand elevator car air purifier, In orderto use this product correctly, please keep this manual carefully for reference.We will strive to meet the individual needs of customers, if there are smallchanges of products, it will not be notified again in the manual.This manual is for below air conditioner model:ALAP-18N ALAP-36N ALAP-18F2ALAP-36F

1. Product FeatureALAP-FALAP-NALAP-F series of elevator car air purifier (connected to the elevator fan power or separate power supply, with its own fan) Safety and reliable, It can also be opened when there are passengers in the elevator car;Rapid sterilization, high efficiency, up to 99%;Broad-spectrum efficiency, the pure physical disinfection method, no secondary pollution;Automatic dust removal function, automatically clean dust on stainless steel filter;Adopting stainless steel and medium-high efficiency double filter to save operating cost;Using Nanometer Photocatalyst technology to effectively remove harmful substances in the air;Reasonable and compact structure design, easy to install, independent power control;Easy to use, can be operated remotely in the car, or timing switch operation by remote control, automatic operation;There is a display panel in the car to display the running state, fault alarm and so on;Low energy consumption, effective lamp service for more than 9000 hours.ALAP-N series of elevator car air purifier (Linked with elevator air conditioner, power is provided by elevator fan or separatepower supply) Safety and reliable, It can also be opened when there are passengers in the elevator car; Rapid sterilization, high efficiency, up to 99%; Broad-spectrum efficiency, the pure physical disinfection method, no secondary pollution; Using nanometer photocatalyst technology to effectively remove harmful substances in the air; Reasonable and compact structure design, easy to install, the power is connected to the original fan power of the elevatoror separately, and the timer is configured; Easy to use, works synchronously with elevator air conditioner; Low energy consumption, long lamp life, effective service time of more than 9000 hours.3

Model InstructionsALAP - 18 FF:Independent installation with built-in fanN: Linked installation with air conditioner UVlamp power(18w or36w)Elevator car air purifierMajor Technical DataModelALAP-18FALAP-36FALAP-18NALAP-36NPower220V 50Hz220V 50Hz220V 50Hz220V 50HzRatedpower(W)Air 600.375.5900015%36/1050.4412900015%4Dimensions(L W ight(kg)ForElevator(kg)13.5 135013.51350 20003 13504.31350 2000

ComponentsALAP-F series Elevator Car Air PurifierMain Unit - ALAP-18(36)FTwo Duct tieФ 200mmRemote ControllerOne Return Air DuctФ 200*1500mmOne Return Air Cover395*60*175mmMedium-high Efficiency Filter450*220*30mmCoarse Filter465*235*30mmALAP-N series of Elevator Car Air PurifierMain Unit - ALAP-18(36)NTwo Duct tieФ 200mm5One Cold air out ductФ 160*1500mm

Use GuideALAP-F Series Elevator Car Air Purifier On/Off:press the key, the machine is turned on, remote controlLCD display; Press again, the machine turn off, remote control LCDdoes not display. “ ”“ ”:press the key, day or week forward or backward,after pressing the "set" key, flash is available. “Program”Key :press the key, enter the program operationmode, run at the set timing, remote controller show program modelon. "Dust removal" key: press the key ,enter the dust removaloperation mode, display dusting on the remote control. “Set”key:① press the key ,show time and hour flash,press“ ”“ ”to adjust hour,press“Set”key to confirm;② Then minutes flash,press“ ”“ ”to adjust minute,press“Set”key to confirm;③ Then Monday flash,press“ ”“ ”to adjust week,press“Set”key to confirm;④ Then timing on display and timing on hour flash, press“ ”“ ”to adjust hour,press“Set”key to confirm;⑤ Then timing on minutes flash. Press“ ”“ ”to adjust minute, press "Set" keyto confirm;⑥ Then timing off display and timing off hour flash, press“ ”“ ”to adjust hour,press“Set”key to confirm;⑦ Then timing off minutes flash. Press“ ”“ ”to adjust minute, press "Set" keyto confirm;⑧ Then timing on Monday flash, press“Setting”key set Monday, then Tuesday flash,press“Set”key set Tuesday, if you do not set Tuesday, press“ ”“ ”to Thursday flash,after finish all the required weeks, press "Set" key to confirm;⑨ Then current hour flash, do not press any key within 5 seconds to confirm that6

the base time and timing time are set and exited. Filter alarm time setting: long press "set" for 5 seconds, then press “ ”“ ” toadjust, adjust to the required alarm time, and then press "set" key to confirm. Clear filter working time: when the remote control is off, long press “on/off” key for 5seconds to clear the filter working time.ALAP-N Series Elevator Car Air PurifierLinked with elevator air conditioner, The timer setting switch-on time isthe same as the working time of the elevator air conditioner, and it runstogether with the elevator air conditioner.Notes and Precautions Only single-phase ac power can be used(220V 50Hz); If the power cord and plug are damaged or the plug is too loose, please do notuse; Replace the filter, UV lamp and internal device, turn off the power and unplug thepower cord when moving and cleaning; When pulling the plug, you must grasp the plug part. Do not pull the power cord; When the remote control is operated, only when the purifier give off a “di” sound,the set by the remote controller is accepted. During testing and installation, operators should take effective protectivemeasures to prevent ultraviolet radiation from damaging eyes and exposed parts of thebody. The relative humidity of the environment should not be more than 85%, andthere should be no corrosive gas in the air; In case it is necessary to see the light tube, use ordinary glass (glasses) ortransparent plastic sheet as a protective mask; When using a new lamp, you can first wipe the lamp with 75% alcohol gauze toremove dust and oil stains. During use, you should wipe it regularly to do a good job ofcleaning the lamp to avoid affecting the purple transmission rate and radiation intensity; Do not modify by yourself, do not disassemble and repair by non-repairtechnicians.7

Care and Maintenance In order to maintain the best working condition of the machine, the machine must becleaned regularly. The plug must be unplugged during cleaning. Do not remove it withwet hands, otherwise it may cause electric shock and injury. Stainless steel filter and coarse or medium-high efficiency filter cleaning and maintenance① Stainless steel filter, the machine itself has an automatic dust removal function,which can be reused. Remove it every 6 months, clean it with water, dry it and put it backin. Extract the dust box from the equipment and dump.② The coarse and medium-high efficiency filters are consumables and need to bereplaced. They are not covered by the warranty. This machine comes with 2 coarse filtersand 1 medium-high efficiency filter. When using on newly installed elevators, werecommend to use coarse-effect filters first, and use medium-efficiency filters after usingthe coarse-effect filters for about 6 months. The replacement time of the high-efficiencyfilter depends on the environment of the elevator. Generally, newly installed elevators arereplaced every 3 months, and elevators that have been used for more than one year arereplaced every 6 months. Maintenance of UV lampsTake out the UV lamp every 3 months and use a hair dryer to clean the dust accumulatedon the surface or wipe the lamp tube with 75% alcohol gauze to remove dust and oilstains. Maintenance of dust removal deviceEvery 3 months, use a rag to remove the dust from the screw of the dust removal deviceand add some butter appropriately.8

Normal Failure Analysis and RestoreFaultsPress the remotecontroller, no soundis heardCheck Items Reasons and ActionWhether the remote display isclear or not Remote run out of battery, change batter. Regulate the position and direction of theWhether the remote receivinginfrared receiving probe.probe blockedDoes not turn on/off at the set time The remote control showswhether there is programUse the remote control to reset thereception.control, and whether theprogram control lamp on thedisplay panel in the car is on.Program control indicator flashesThe service time of coarse or Replace coarse or medium-high efficiencymedium-high efficiency filter hasfilter, and when the remote control is off,reached the set value, so thepress the key for 5 seconds to clear the filterfilter needs to be replaced.Disinfection lamp flashesDust removalUV lamp working time reaches Replace the UV lamp, and long press the8000 hours, reminding the needswitch button in the main control board forto replace the UV lamp.5 seconds. UV lamp failure. Replace the UV lamp. Whether the dust removal motor Remove dust or foreign matter from screwscrew is stuck because of dirt. Ask a professional for repair andindicator flashes Dust motor or rotation sensor isreplacementbrokenUV lamp and fan do Whether the dust is working After the dust removal motor stops working,not work during thethe machine works normally after 15set timeminutes.9

Schematic Circuit DiagramALAP-18(36)F air purifier:ALAP-18(36)N air purifier: (Note: it is connected with the air conditioner,the power is connected to the original fan power of the elevator or separately,and the timer is ��插座Socket黄/绿Yellow/Green10插头Plug

DimensionALAP-18NALAP-36N11

ALAP-18(36)F12

Installation ALAP-N series of elevator car air purifier (Linked with elevator airconditioner, the power is connected to the original fan power of theelevator or separately, and the timer is configured.)①ALAP-N series of purifier is installed between the air outlet of the air conditioner and thewind out cover (cold air out duct). The two air outlets of the purifier are connected to the airconditioner and the wind out cover and held tightly with a duct tie (if the air duct is too long,it needs to be cut short).②The power supply of the ALAP-N series of purifier is 220V, which is connected tothe three-hole socket at the 220V power supply of the car roof (it is recommended thatthe purifier power is connected to the power supply of the elevator fan, so that thedriver's control panel in the car can control the purifier power supply, or the purifier canbe controlled according to the time set by the timer).③Set the reference time of the timer and the switch-on time of the purifier (set the operationaccording to the operation instructions of the timer).④Plug in the timer and purifier plug, the purifier will run automatically according to thetime set by the timer.⑤Set the air conditioner to turn on and off automatically. The time to turn on and off theair conditioner should be the same as or longer than that of the purifier.The installation diagram is as follows:13

ALAP-Fseries of elevator car air purifier (connected to theelevator fan power, with its own fan)① Determine the air supply hole of the purifier. It is recommended to use the originalfan hole on the elevator. When installing the purifier, remove the original fan, align the airoutlet of the purifier with the fan port on the car roof, and fix the purifier on the car roof;② Determine the air return hole of the purifier. use the original fan port on theelevator or open a new rectangular hole as the return air hole, fix the return air hood, andthen connect the purifier to the return air hood with a ventilation pipe;③ The remote control receiving probe and display panel of the purifier are introducedinto the car and fixed ,connect to the power supply;④ Use the remote control to remotely switch on and off in the car, or set the timingswitch on the remote control at the required time, and then enter fully automatic operation.The installation diagram is as follows:14

ALAP-N series of elevator car air purifier (Linked with elevator air conditioner, power is provided by elevator fan or separate power supply) Safety and reliable, It can also be opened when there are passengers in the elevator car; Rapid sterilization, high efficiency, up to 99%;