ROOF DECK CATALOG Roof Deck - Ascsd

Transcription

CLICK HERE TO GO TO TABLE OF CONTENTSROOF DECK CATALOGVersion 2.1offering products that meet the needsof the most complex conditions anddemands for structural performanceand design.www.ascsd.comroof deckASC Steel Deck is an industry leader

Return to TABLE OF CONTENTSIntroduction 1.1Our CompanyASC Steel Deck is a structural steel deck manufacturerleading the way through an unmatched commitment tothe success of our customers. ASC Steel Deck pridesitself on delivering the best-in-class service experience,easily accessible technical data, and having to mostknowledgeable and responsive team in the industry. Servingthe Western United States since the 1970s, ASC Steel Deckhas undergone a few ownership changes and operatedunder different business names (ASC Pacific, BHP SteelBuilding Products, and IMSA Building Products). Since2002, we have operated as ASC Steel Deck, a division ofASC Profiles LLC. While the name of the company haschanged over the years, our continuous dedication toproduct innovation, high-quality steel deck products, andexceptional customer service has positioned ASC SteelDeck as a trusted leader in the industry.Industry Leadership Through InnovationASC Steel Deck has established itself as an industry leader having accomplished many industry-firsts. ASC Steel Deckwas the first West Coast manufacturer to incorporate diaphragm shear and superimposed load tables based on ANSI/SDIC-2011 Standard for Composite Steel Floor Deck-Slabs. This standard has been adopted for inclusion in the 2015 IBC.ASC Steel Deck has also led the way in providing innovative products which reduce installation costs at the highest levelof performance. Several examples include: Smooth Series rivet attachment for our portfolio of cellular deck products offers a blemish free attachment solution,eliminating the need for field touch up and saving on labor costs and time. New to the West Coast. 36/7/4 Attachment Pattern - reduces attachment requirements for 11 2" roof deck by up to 30%. N-32 Roof Deck - A 32" wide by 3" deep roof deck profile providing a 10% improvement in steel utilization andup to 20% reduction in installation costs as compared to the industry standard N-24 panel.

ASC Steel Deck is leading the way in innovation with ongoing testing of our profiles. As a result, the printed catalogmay not contain/reflect the latest test results and values of our products. For the most current load tables, refer to ourcatalog online at www.ascsd.com.B PANELSYour Feedback is WelcomeLeading the way in steel deck innovation is dependent upon your feedback. We invite architects, engineers, buildingowners, and all members of the building design and construction industry to reach out to ASC Steel Deck with anycomments, suggestions, or needs for a profile we currently do not offer.GENERAL INFORMATIONTable of ContentsEmail us at info@ascsd.com1.0 GENERAL INFORMATIONPanel Features and Benefits . . . . . . . . . . . . . . . . . . . . . . 2-3Product Offer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6Product Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Fire Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11Section Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13Out of Plane Vertical Loads . . . . . . . . . . . . . . . . . . . . . 14-15Web Crippling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17In Plane Diaphragm Shear . . . . . . . . . . . . . . . . . . . . . . 18-19In Plane Diaphragm Flexibility . . . . . . . . . . . . . . . . . . 20-21Support Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-27Side Seam Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-312.1 DGB-36, B-36 & BN-36 Properties & Vertical Loads . . 32-332.2 DGB-36 Allowable Wind Uplift Loads . . . . . . . . . . . . . 34-372.3 DGBF-36 & BF-36 Properties & Vertical Loads . . . . . 38-41Diaphragm Shear TablesDGB-36 & DGBF-36 Welds to Supports . . . . . . . . . . . 42-43DGB-36 & DGBF-36 Screws to Supports . . . . . . . . . . 44-46DGB-36 & DGBF-36 Hilti Nails to Supports . . . . . . . . 47-52DGB-36 & DGBF-36 Pneutek Fasteners to Supports . . 53-65BN-36 Screws to Supports . . . . . . . . . . . . . . . . . . . . . 66-73BN-36 Hilti Nails to Supports . . . . . . . . . . . . . . . . . . . . 74-81B-36S Welds to Supports . . . . . . . . . . . . . . . . . . . . . . . 82-853.0 N PANELS3.1 DGN-32, N-32 & NN-32 Properties & Vertical Loads . . 86-873.2 DGN-32 Allowable Wind Uplift Loads . . . . . . . . . . . . . 88-893.3 DGNF-32 & NF-32 Properties & Vertical Loads . . . . . 90-93Diaphragm Shear TablesDGN-32 & DGNF-32 Welds to Supports . . . . . . . . . . . . . 95DGN-32 & DGNF-32 Screws to Supports . . . . . . . . . . 96-97DGN-32 & DGNF-32 Hilti Nails to Supports . . . . . . . 98-101DGN-32 & DGNF-32 Pneutek Fasteners to Supports 102-109N-32 Welds to Supports . . . . . . . . . . . . . . . . . . . . . . 110-113NN-32 Nestable Welds to Supports . . . . . . . . . . . . . . . 114NN-32 Nestable Screws to Supports . . . . . . . . . . . 115-117NN-32 Nestable Hilti Nails to Supports . . . . . . . . . 118-119NN-32 Nestable Pneutek Fasteners to Supports . . . 120-123Diaphragm Shear TablesDG2WH-36 & DG2WHF-36 Welds to Supports . . . . . . . 131DG2WH-36 & DG2WHF-36 Screws to Supports . . . 132-134DG2WH-36 & DG2WHF-36 Hilti Nails to Supports . 135-140DG2WH-36 & DG2WHF-36Pneutek Fasteners to Supports . . . . . . . . . . . . . . . . . 141-1524.7 DG3WxH-36 Properties & Vertical Loads . . . . . . . . 153-1554.8 DG3WxHF-36 Properties & Vertical Loads . . . . . . . 156-159Diaphragm Shear Tables4.9 DG3WxH-36 & DG3WxHF-36 Welds to Supports . . . . . 1604.10 DG3WxH-36 & DG3WxHF-36 Screws to Supports . 161-1634.11 DG3WxH-36 & DG3WxHF-36Hilti Nails to Supports . . . . . . . . . . . . . . . . . . . . . . . 164-1694.12 DG3WxH-36 & DG3WxHF-36Pneutek Fasteners to Supports . . . . . . . . . . . . . . . . . 170-1816.0 C1.4/CP-32 & C0.9-326.16.26.36.46.56.6C1.4/CP-32 Properties & Vertical Loads . . . . . . . . .C1.4/CP-32 Diaphragm Shear Tables . . . . . . . . . . .Inverted C1.4/CP-32 Properties & Vertical Loads .Inverted C1.4/CP-32 Diaphragm Shear Tables . . . .C0.9-32 Properties & Vertical Loads . . . . . . . . . . . .C0.9-32 Diaphragm Shear Tables . . . . . . . . . . . . . .182-184186-187188-190191-192193-194195-1977.0 Acustadek 7.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198-1997.2 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200-2017.37.47.57.67.77.87.97.10Properties & Vertical LoadsDGB-36AW & B-36AW . . . . . . . . . . . . . . . . . . . . . . .DGB-36AT & B-36AT . . . . . . . . . . . . . . . . . . . . . . . . .DGBF-36A & BF-36A . . . . . . . . . . . . . . . . . . . . . . . . .DGN-32AW & N-32AW . . . . . . . . . . . . . . . . . . . . . . .DGN-32AT & N-32AT . . . . . . . . . . . . . . . . . . . . . . . . .DGNF-32A & NF-32A . . . . . . . . . . . . . . . . . . . . . . . . .DG2WHF-36A & 2WHF-36A . . . . . . . . . . . . . . . . . . .DG3WxHF-36A & 3WxHF-36A . . . . . . . . . . . . . . . . 222-225Metric Conversion Chart . . . . . . . . . . . . . . . . . . . . . . . 226Hilti is a registered trademark of Hilti Corp., LI- 9494 Schaan, Principality of LiechtensteinPNEUTEK is a registered trademark of Pneutek, 17 Friars Drive Hudson, NHwww.ascsd.comRoof Deck Catalog V2.11ACUSTADEK .4 & CO.9-322.42.52.62.72.82.92.104.1 DG2WH-36 Properties & Vertical Loads . . . . . . . . . 124-1264.2 DG2WHF-36 Properties & Vertical Loads . . . . . . . . 127-1302W & 3Wx PANELS2.0 B PANELS4.0 2W & 3Wx ROOF DECK PANELSN PANELS1.11.21.31.41.51.61.71.81.91.101.111.12

Return to TABLE OF CONTENTS1.1 Panel Features and BenefitsDGB-36/B-36DGN-32/N-32 1½ ” depth, 36” coverage, 5’ to 12’ Optimal Span(s)3 ” depth, 32” coverage, 10’ to 16’ Optimal Span(s) Excellent Diaphragm Shear Good Diaphragm ShearWeb and Total Perforated Acustadek OptionsWeb and Total Perforated Acustadek Options DeltaGrip produces the highest shear diaphragms inthe industry for 1½” decks DeltaGrip produces the highest shear diaphragms inthe industry for 3 inch decks Highest shear lowest cost 36/7/4 attachment patternin industry Wider 32” panel results in the most labor efficient 3”N Deck in the industry Published tables for welded, pinned, and screwedattachments to supports Lightest weight 3” N deck per square foot in theindustryBN-36 NESTABLENN-32 NESTABLE1½ ” depth, 36” coverage, 5’ to 12’ Optimal Span(s)3” depth, 32” coverage, 10’ to 16’ Optimal Span(s) Good Diaphragm Shear Modest Diaphragm ShearNo AcustadekNo Acustadek Option Option Nestable configuration for screwed side lapattachment Nestable configuration for screwed side lapattachment Meets Steel Deck Institute SDI wide rib requirements Replaces Steel Deck Institute SDI Deep Rib (DR)roof decksDGBF-36/BF-36DGNF-32/NF-321½ ” depth, 36” coverage, 8’ to 14’ Optimal Span(s)3” depth, 32” coverage, 14’ to 20’ Optimal Span(s) Excellent Diaphragm Shear Good Diaphragm ShearPan Perforated Acustadek Option (Available withSmooth Series rivet attachments or welded)Pan Perforated Acustadek Option (Available withSmooth Series rivet attachments or welded) Aesthetic flat pan underside2 Aesthetic flat pan underside Longer Spanning than non-cellular profile Longer Spanning than non-cellular profile DeltaGrip side-lap attachment provides the samebenefits as non-cellular DeltaGrip side-lap attachment provides the samebenefits as non-cellularV2.1 Roof Deck Catalogwww.ascsd.com

Panel Features and Benefits 1.1DG3WxH-36/3WxH-36 (Roof Deck)2” depth, 36” coverage, 8’ to 14’ Optimal Span(s)3” depth, 36” coverage, 11’ to 20’ Optimal Span(s) Good Diaphragm Shear Good Diaphragm ShearNo Acustadek OptionNo Acustadek Option DeltaGrip side-lap attachment for good shearperformance DeltaGrip side-lap attachment for good shearperformance Most economical panel per square foot for the spancapacity Meets Steel Deck Institute SDI 3”x12” requirementsB PROFILESDG2WH-36/2WH-36 (Roof Deck)N PROFILES Meets Steel Deck Institute SDI 2”x12” requirementsDG3WxHF-36/3WxHF-36 (Roof Deck)2” depth, 36” coverage, 10’ to 20’ Optimal Span(s)3” depth, 36” coverage, 14’ to 22’ Optimal Span(s) Good Diaphragm Shear Good Diaphragm ShearPan perforated Acustadek OptionPan perforated Acustadek Option Aesthetic flat pan underside Aesthetic flat pan underside Longer Spanning than non-cellular profile Longer Spanning than non-cellular profile Most economical panel per square foot Meets Steel Deck Institute SDI 2”x12” requirements2W & 3W PROFILESDG2WHF-36/2WHF-36 (Roof Deck)DEEP DECK PROFILES Meets Steel Deck Institute SDI 2”x12” requirementsC0.9-32 (CF7 8)13 8” depth, 32” coverage, 5’ to 10’ Optimal Span(s)7 Modest Diaphragm Shear Low/Modest Diaphragm ShearNo Acustadek OptionsNo Acustadek Options C1.4-32 is suitable for exposed roofing and sidingconditions CP-32 is manufactured with a side lap rolled in ventfor use with lightweight insulating concrete fillCP-32C1.4-32/CP-32 (CF13 8) GENERAL INFORMATIONReturn to TABLE OF CONTENTS 8” depth, 32” coverage, 1’ to 5’ Optimal Span(s)Non-composite deck Good for short span conditionsACUSTADEKwww.ascsd.comRoof Deck Catalog V2.13

Return to TABLE OF CONTENTS1.2 Product OfferASC Steel Deck offers a robust product offer. Our lightweightsteel deck profiles have depths that range from 7 8” to 71 2”.Panel lengths range from 5 feet to 45 feet. Steel deck panelsare supplied with both galvanized and painted finishes to meetan array of project finish requirements.Product DescriptionTo assist designers with specifying the correct steel deckprofile, see Figure 1.2.3 which details how to specify theintended product. Following these guidelines will helpto eliminate requests for information and change ordersdue to insufficient product descriptions in the plans andspecifications. Designers can be assured that the productdelivered is the product intended. Simply specify the gage,panel profile, panel coverage, metallic/paint coating, and anymodifiers appropriate for the desired product.Deck Panel LengthsAll ASC Steel Deck products are manufactured to the specifiedlength for the project. The following table summarizes theminimum and maximum lengths that can be manufactured foreach profile.Figure 1.2.1: MANUFACTURED PANEL LENGTHSProfileFactory Cut LengthNon-cellularCellularMinimumMaximumB-36, N-32,2W-36, -36, NF-32,2WF-36, 3WF-365’-0”40’-0”TolerancesASC Steel Deck manufactures to industry standard tolerances.The tolerances are summarized as follows.Figure 1.2.2: PANEL TOLERANCESLength 1/2”Coverage Width-3/8” 3/4”Sweep1/4” in 10’ lengthSquare1/8” per foot widthFinish OptionsASC Steel Deck offers several finish options that areappropriate for a variety of applications. Our standard G60galvanized finish is suitable for most applications, offeringexcellent corrosion protection and compatibility with fireproofing when used in UL fire rated assemblies. We also offerPrimeShield , an economical prime paint system over barecold rolled steel. PrimeShield offers the steel limited interimprotection from rusting during transport and erection beforethe weather-tight roof system is applied. PrimeShield shouldnot be used in high humidity or corrosive environments. Primepaint over galvanized steel deck can also be specified toobtain the benefit of the corrosion protection of galvanizedsteel deck with a factory applied prime paint substrate.4V2.1 Roof Deck CatalogGalvanizedASC Steel Deck offers steel deck products that are galvanizedin accordance with ASTM A 653. The standard galvanizedcoating is G60 (0.6 ounce per square foo

ROOF DECK CATALOG Version 2.1 roof deck ASC Steel Deck is an industry leader offering products that meet the needs of the most complex conditions and demands for structural performance and design. Introduction 1.1 Industry Leadership Through Innovation ASC Steel Deck has established itself as an industry leader having accomplished many industry-firsts. ASC Steel Deck was the first West Coast .