WALK IN

Standard Hood Features3Laboratory Fume Handling4Walk In Fume Hood-AD SeriesModels6Technical Specification7Options and Accessories8Warranty9Walk In Fume Hoods25www.advancelabglobal.com

Walk In Fume HoodsStandardHoodFeaturesDouble layered designAerodynamic front fasciaIndustrial grade galvanised steel constructionHeavy epoxy powder coated finish towithstand harsh laboratory environmentsPhenolic resin inner liner and baffle withbuilt in slots for efficient scavengingPurpose built light box external to airflow,preventing any corrosion and minimizingturbulenceElectronic light ballast for flicker free usageand user eye comfortCounterbalanced sash assembly for years oftrouble free useTempered safety glass with Easygrip hand rail2 side access panels built into inner liner forfuture addition of utilitiesAll fume hoods comply to exhaustrequirements and face velocity test as perASHRAE 110-95; when ordered withcontrol systems, units also comply to BS7258 and EN 14175www.advancelabglobal.com3

LaboratoryFumeHandlingLaboratory fume hoods or fume cupboardsrepresent the primary line of defense forpersonnel against exposure to harmful, toxicand dangerous fumes or chemicals as they areproduced.“Fume hoods are essentiallyaerodynamic scavenging devices that remove dangerous fumesfrom a laboratory and expel itinto the environment where it issufficiently diluted to no longerpose a health risk.”Walk In Fume HoodsAdvancelab Laboratory fume hoods havebeen manufactured to provide the highestlevels of safety for laboratory personnel.4Fume hoods when sized with an appropriatechemical resistant centrifugal exhaust fan willprotect laboratory staff from exposure toharmful fumes.Please contact our distributors or offices tohelp or design an efficient exhaust system.www.advancelabglobal.com

AD Serieswww.advancelabglobal.comWalk In Fume HoodsWalk In Fume Hood5

ModelsMODELDimensions, (LxWxH)AD04FHWAD05FHWAD06FHWAD08FHW1220 mm x 920mm x2420mm1520mm x 920mm x2420mm1820mm x 920mm x2420mm2420mm x 920mm x2420mmBodyElectrogalvanised steel with heavy epoxy powder coated finishWorktopN/AInner Liner & BafflePhenolic resin, laboratory gradeAirfoilN/AStandards CompliedASHRAE 110-95BS 7258 (with Optional Controller)EN 14175 (with Optional Controller)Services1 Pre Plumbed Cold Water Remote1 Pre plumbed Gas RemoteControlsFan ON/OFF switchLight ON/OFF switchBaseN/ADuct Collar200 mmDesign VelocityExtract Volume at 500 mmHeight Sash Opening4 x Pre wired 13 Amp Switch socket outlets (BS)1 PP Cup Sink250 mm300 mm300 mm x 20.5 m/s at 500mm sash height1188 CMH1512 CMH1836 CMH2481 CMHWalk In Fume HoodsSash Configuration6Working PositionFull Close Positionwww.advancelabglobal.comFull Open Position

Specifications12Walk In Fume HoodsTechnicalTop ViewSide View920341. PVC Exhaust Collar2. Electrical Junction Box3. External Light Box4. Side Access Panel5. Removable Front Panel6. Tempered Glass Sash7. PP Cup Sink8. Electrical Outlets9. Fan ON/OFF Switch10. Light ON/OFF Switch11. Gas Fixture Remote12. Water Fixture Remote13. Gas Faucet14. Water Faucet2420Front View591214610111387www.advancelabglobal.com7

Options and AccessoriesSuperstructureDistillation GridIndustrial Grade Electrogalvanised Steel (Standard)SS 304SS 316PolypropylenePVDFAluminiumSS 304SS 316Inner Liner ConstructionPhenolic Resin (Standard)SS 304SS 316PolypropylenePVDFSinkDrip Cup- Polypropylene(Standard)Locationx y yCustom Sink- SS 304- SS 316- Polypropylene (Hot Weld Construction)- Size: mm (L x W x H)please specifyMicroprocessor Airflow AlarmxServicesCompressed Air (CA)Distilled Water (DI)Nitrogen (N2)Digital Display with AlarmDigital Display with Alarm &VAV/VSD OutputmmmmOxygen (02)Vacumn (Vac)Ex Proof ConfigurationsEx proof lightsEx proof on/off switchEx proof Electrical SocketsEx proof electrical junction boxPlease advice factory of details requiredElectrical OutletWalk In Fume HoodsType B8Type GBritish BSType IAmerican NEMA,Japanese JISType CBrazil NBREuro CEE7Type FEuro CEE7Australia ASChina GBType JSwiss SEVwww.advancelabglobal.comType LType KDenmark AFSNITItaly CEIType MIndia IA

Walk In Fume HoodsWarrantyProducts Manufactured by Advancelab: Advancelab(S) Pte.Ltd., warrants products that it manufactures tobe free from defects for a period of 12 months for parts, commencing from the date of shipment. Advancelab’ssole responsibility is to repair or replace, at its option, any part of the product that proves defective ormalfunctioning during this time limit. This warranty is void if the equipment is abused or modified by thecustomer, is operated outside Advancelab’s operating instructions or specifications, or is used in anyapplication other than that for which it is specified. This warranty does not include routine maintenance orservice procedures, breakage, shipping damage, nor damage from misuse, intentional or unintentionalabuse, neglect, natural disasters, or acts of God.Freight Shortage or Damage: Upon receipt of any equipment from Advancelab, customer shall immediatelyunpack and inspect for damage or shortage. The customer shall not accept a damaged package or a shortshipment until the carrier makes a "damage or shortage" notation on both the carrier's and customer's copyof the freight bill or delivery receipt. Service title passes when the shipment is loaded, so customer isresponsible for filing and collecting a freight claim. Any replacement products must be ordered andpaid for separately.Generally, customers can improve the chance of collecting on a freight claim by following these procedures:1. Formally requesting that the carrier inspect the shipment immediately upon suspecting damage orshortage to verify condition.2. Notifying the carrier upon discovery of concealed damage and requesting an inspection within 15days of receipt, both in person or phone and following up via mail.3. Keeping the shipment as intact as possible, including retaining original packaging materials and keepingthe product as close to the original receiving location as possible.4. Holding salvage for disposition by the carrier.All Claims: Advancelab (S) Pte.Ltd., expressly disclaims all other warranties, expressed or implied or impliedby statute, including the warranties of merchantability or fitness for intended use. Advancelab is notresponsible for consequential or incidental damages arising out of the purchase or use of the productssupplied by Advancelab. Advancelab is not liable for damage to facilities, other equipment, products,property or personnel of others, or of their agents, suppliers, or affiliated parties, which is caused or allegedto have been caused by products supplied by Advancelab. In any event or series of events, Advancelab’stotal liability for any and all damages whatsoever is limited to the lesser of the actual damages or theoriginal invoice cost of the items alleged to have caused the damage. The customer’s sole and exclusiveremedy for any cause of action whatsoever is repair or replacement of the non-conforming products orrefund of the actual purchase price, at the sole option of Advancelab. All claims must be made in writingwithin 90 days of the date the product was shipped. Any claims not made within this time limit shall bedeemed waived by the customer. Advancelab is not responsible for any additional costs of repair causedby poor packaging or in-shipment damage during return.Warranty Returns: All warranty returns must be authorized in advance by Advancelab and approved bywriting. Unless approved in advance for good reason, all returns must be in original condition, including allmanuals, and must be packaged in original packaging materials. All returned goods are to be shipped toAdvancelab, freight prepaid at customer’s expense.www.advancelabglobal.com9

WALK INAdvanceLab has built a rock steady reputationfor solutions where most fail. Since ourestablishment in 2003, we have positionedourselves as the premier facility solution providerfor the scientific industry; designing, buildingand delivering quickly and without fuss. We havealso taken our brand of expertise globally; nowwith exports of laboratory casework, fumehoods, laminar flow cabinets and clean boothsheading to 30 countries, covering all continents.IndonesiaMalaysiaMyanmar253 Kaki Bukit Ave 1No. 3388, Jalan Pekeliling TanjungNo.(81/1)-1A, Myin Thar 7th Street,Tel: 65 6448 825581000 Kulaijaya, Johor, Malaysia.Yangon, MyanmarPT. Advancelab SaintifikAdvancelab Sdn Bhd27/2, Kawasan Perindustrian Indahpura,Singapore 416619Fax: 65 6448 9833Email: info@advancelab.com.sgTel: 607 660 8877Fax: 607 660 8866Email: info-my@advancelab-global.comSingaporeThailand253 Kaki Bukit Ave 1147 / 170 - 171 BaromrajchonnaneeTel: 65 6448 825510700, Thailand.Advancelab (S) Pte LtdAdvancelab Scientific &Engineering Co., Ltd(14/1)Ward, South Okkalapa Township,Tel: 95 (9) 779753802Email: info-mm@advancelab-global.comPrima ScientificCo., LtdRoad, Arunamarin Bangkoknoi, BangkokSingapore 416619Fax: 65 6448 9833Email: info@advancelab.com.sgTel: 66 2 884 9480Fax: 66 2 884 6441Email: iland

Walk In Fume Hood 5 Walk In Fume Hoods www.advancelabglobal.com. Dimensions, (LxWxH) 1220 mm x 920mm x 2420mm 1520mm x 920mm x 2420mm 1820mm x 920mm x 2420mm 2420mm x 920mm x . PP Cup Sink 8. Electrical Outlets 9. Fan ON/OFF Switch 10. Light ON/OFF Switch 11. Gas Fixture Remote 12. Water Fixture Remote 13. Gas Faucet 14. Water Faucet