PERSONNEL MANAGEMENT KIOSKS - Meridian Kiosks

Transcription

PERSONNEL MANAGEMENT KIOSKSDateTimeAdmittanceBody temperature 97.3 Fwww.meridiankiosks.com/pmk-resources/For FAQs and other support information for this product, visit the above site.Model # - PMK 01A-PO

Caution1. The battery in this device is not userserviceable.2. PMK readings should be regarded as areference. Do not attemptself-diagnostics or self-treatment usingthe temperature readings. Please seekprofessional medical advice whennecessary.3. There is no absolute standard forhuman body temperature. Knowing yourown normal body temperature range isimportant to accurately determine if youhave a fever.4. The forehead of the subject should befree from sweat, hair and otherobstructions before measuring.5. Users should not drink, eat, or bephysically active immediatelybefore/while taking a reading.Temperature readings taken when abody is in a state of stable equilibriumare more accurate.6. It is normal for readings taken fromcontinuous measurements1 to fluctuatewithin a small range.7. Do not directly face the sun or the airoutlet of an air conditioning or radiatordevice during measurement, as this cancause changes to the foreheadtemperature. Measurements should betaken in a stable environment.8. Avoid dropping or subjecting theproduct to external forces duringinstallation or use.9. Do not measure body temperature inan environment with strongElectromagnetic interference (examplesinclude places close to a workingmicrowave, induction cooker, or acellphone in-use) as EM interference maycause errors in the reading or evendevice failure.This device is not FDA-cleared orapproved. This temperature deviceshould not be solely or primarily reliedupon to diagnose or exclude a diagnosisof COVID-19, or any other disease orhealth condition. Elevated body temperature in the context of use should beconfirmed with secondary evaluationmethods, such as a non-contact infraredthermometer or clinical grade contactthermometer.Public health officials, through theirexperience with the device in the particular environment of use, should determine the significance of any fever orelevated temperature based on thetemperature readings of this device.Product InformationProduct Name: Personnel ManagementKiosk (PMK)Product Type: IndoorProduct Model: PMK 01A-POThank you for choosing Meridian’s Personnel Management Kiosk (PMK). Thisproduct uses the thermal image of aperson’s face to accurately determine aperson’s skin surface temperature. ThePMK features temperature verificationcapabilities and can also be programmed for facial identification.Safety Precautions Use of the PMK is not intended as asubstitute for consultation with yourphysician. Please consult your internalprotocol in the event of an abnormaltemperature reading. Never stand, climb, sit, or hang on thedevice.1

Caution (CONT)10. We suggest calibrating your deviceonce a month or more frequently if youhave fluctuations in your ambienttemperature of more than 2.0 C (5.6 F).11. This device has been evaluated tostandards similar to IEC 80601-2-59:2017:Medical electrical equipment – Part 2-59:Particular requirements for the basicsafety and essential performance ofscreening thermographs for humanfebrile temperature screening.Cleaning1. Clean and sanitize the product properlyto prevent cross contamination.2. To clean the PMK, gently wipe the kioskwith a clean microfiber cloth sprayed witha 70% isopropyl alcohol based solution.Be sure to prevent liquid from enteringthe kiosk components. Wipe the kiosk drywith a clean microfiber cloth.3. Do not directly touch the thermalsensor with your fingers or blow on it.Measurements taken using a damaged ordirty thermal sensor may be inaccurate.About the Product1. This product is a precision device. Toensure accurate measurements, keep thedevice from direct liquid contact. Avoidtiny particles falling onto the sensor.2. To access the application settings, usethe provided keyboard and mouse.3. Visit our resource webpage forinstructions on how to use the includedkeyboard and mouse.2Overall DescriptionThe PMK is comprised of a castaluminum casing, thermal sensor, LEDlights, dual lens camera, non-touch LCDdisplay, and an optional RFID reader.ThermalscannerlampDate andtimeDateTime8” LCDscreenPass/FailDisplayIR light CameraUserImageAdmittanceBody temperature 97.3 FRFIDreader*Dimensions: 11.67 in x 5.23 in x .97 in(29.64 cm x 13.28 cm x 2.5 cm)Weight: 2.9 lbs (1.3 kg)Product Performance Reference Body Site: Face/forehead Measurement Distance: 20 in (50 cm) Power Input: 100 - 240V 50/60Hz Power Output: DC12V ( 10%) Power Consumption: 13.5W (Max) Measurement Range: 50 F - 107.6 F(10 C - 42 C) Temperature Variance: 0.9 F ( 0.5 C) Expected Product Life Span: 5 Yrs Operating System: Android Operating Conditions: Temperature: 32 F - 140 F (0 C - 60 C) Humidity: 10% - 60% Indoor use only

ParametersCameraScreenProcessorResolution2 MP (Mega-Pixels)TypeBinocular wide dynamic cameraApertureF2.4FocusingDistance20 in - 60 in (50 cm -150 cm)White BalanceAutoPhoto LightLED and IR dual photo lightSize8.0 in (20.32 cm) IPS LCD screenResolution800 1280 PixelsTouchNot supportedCPURK3288 quad-coreStorage8GB (Embedded Non-Expandable)Network Module Ethernet and wireless 2.4GHz (WiFi)InterfaceAudio2.5W / 4R speakersUSBUSB 2.0 (2 Ports)SerialCommunication1 RS232Relay ControllerRelayControllerSignalSignal0/12 volts switching (Dry Contact)WiegandOne Wiegand 26/34 output, one Wiegand 26/34 inputWired Network1 RJ45 Ethernet socket3

Face DetectionSupportFace LibraryUp to 20,0001: N FaceFunction RecognitionSupport1: 1 ortMouse InstructionsRight Mouse ButtonThe right mouse button can be used to exit a pageor go back. It can also be used to bring up thepassword prompt to access the Android homescreen.Center Mouse ButtonThe center mouse button can be used to bring upthe password prompt to access the applicationsettings. Please note, the button must be clicked,not scrolled.Left Mouse ButtonThe left mouse button is used to make selections.Access In-Depth Manuals Scan this QR Code to access videos, FAQs, andother guide materials to help you get your deviceup and running as quickly as possible. You can also visit this es/4

Temperature Reading CalibrationYour PMK arrives in a calibrated statefrom the factory, using a blackbody deviceas a reference temperature source. Onceset-up is completed, verify the readings ofthe PMK based on an FDA cleared thermalforehead thermometer. If needed, adjustthe temperature compensation value ofthe PMK. Temperature compensation onthe device must be entered in Celsius.Please refer to our website for details. Wesuggest calibrating your device once amonth or more frequently if you havefluctuations in your ambient temperatureof more than 2.0 C (5.6 F).Instructions for Use1. After removing the PMK from itspackaging, inspect the kiosk and powercord for damage.2. Plug in the power cord to turn thekiosk on. Wait 10 minutes.3. The thermal scanner will first scan thecurrent ambient temperature distributionafter turning on. During this 10 to 20second process, it is best not to haveanyone in the scanner’s field of view.4. Avoid direct sunlight, areas withextreme high or low temperatures, highhumidity, vibration, radiation, andcorrosive chemical environments.5. Do not install near radiant heatBody Temperaturesources and avoid high temperature1. Body temperature varies from personobjects in the field of view.to person and fluctuates during the6. All electrical safety regulations must becourse of the day. For this reason, it isstrictly observed. A surge protector issuggested to know one’s normal, healthyrecommended.forehead temperature to accurately7. Protect the power cord from beingdetermine the temperature.walked on or pinched. Do not pull out the2. Reading times may differ according toplug by tugging at the cord and neverskin tone, measurement distance, andtouch the power cord when your handslighting conditions.are wet. Never make a knot in the cord.3. Different measurement methods may8. Please use the power adaptergive different readings. Therefore, youprovided. If it is ever damaged contactshould compare your readings from thetechnical support. For specificPMK to an IR forehead thermometer.requirements of the power adapter, seethe product performance section.4. Instances that can affect the tempera9. The kiosk should not be facing ature reading of an individual:reflective background such as glass. If Wearing glassesthere is glass, cover it with an opaque Hair covering the foreheadmaterial with a color closer to white than Hats and other head coveringsblack. Direct sunlight on the kiosk or user10. If you change kiosk locations, wait 10 Moisture from rain or snowminutes after power up to take a Medical conditions that raise thetemperature measurement.surface temperature of the face5. If an abnormal temperature is detected 11. When choosing a kiosk location, theon an individual that has just come inside, number of individuals being screenedand their rate of presentation need to beplease wait at least 3 minutes beforeconsidered.taking another measurement.5

12. This device should be usedto screen only one subject at a time. Theindividuals to be screened should stand ina single file line, while respecting socialdistancing guidelines, and stop at the PMKfor their temperature screening.13. If the product does not work properly,do not disassemble or modify the productin any way. Meridian does not assume anyresponsibility for problems caused byunauthorized modification or repair.14. Do not immerse the product in water.15. Please understand that you are responsible for properly configuring all passwordsand other security settings.16.Default application password is "123456".Any new password MUST be 6 charactersor less. PASSWORD CANNOT BE RESETOR RECOVERED ONCE CHANGED! If thepassword is lost, the head unit will need tobe returned to factory to be manuallyreformatted. There will be a 200 charge,plus shipping, for this service. Please sendrequest to help@mzero.com for returnauthorization.17. Contact technical support if you believeyour device needs to be serviced. There areno operator serviceable components in thePMK.ReferencesThis document provides information consistent with the guidelines in ISO/TR13154:2017: Medical electrical equipment-- Deployment,implementation andoperational guidelines for identifyingfebrile humans using a screening thermograph.Measurement Process1. Approach the front of the kiosk untilyour face fits the designated area on thescreen. The ideal distance for measuringthe temperature of an individual is 20inches (50 cm).2. After 1-3 seconds, the screen will display your temperature reading.When a normal temperature is detected,a message will tell the user if they have anormal temperature.3. When a high temperature is detectedthe photo flood lamp will turn RED andan alarm will sound for a few seconds.4. You can toggle the temperaturethreshold and other settings in the application.Acceptance Process1. The individual needs to be preprogrammed into the face database and/orhave Stranger/Visitor Mode on.2. After 1-3 seconds, the screen will display your temperature reading.When a normal temperature is detected,a message will tell the user if they have anormal temperature and the photo floodlamp will turn GREEN. A second messagewill display showing the use has beenadmitted.FCCThis device complies with Part 15 of theFCC Rules.CEThis device is in compliance with alldirectives applicable to CE.ComplianceDo not change or modify this devicewithout expressed approval from themanufacturer. It could void your warranty.Complies with UL/SCA C22.2No. 62368-1E2127456

Précautions de Sécurité L’emploi du Kiosque de Gestion duPersonnel (KGP) n’est pas prévu pourremplacer la consultation avec votremédecin. Veuillez consulter votre protocole interne en cas de relevé detempérature anormal. Ne jamais se tenir debout, grimper,s’asseoir ou se suspendre sur l’appareil.Avertissement7. Ne pas se tenir directement face ausoleil, près de la sortie d’air d’unclimatiseur ou auprès d’un radiateurpendant la mesure, puisque cela peutprovoquer des changements de latempérature du front. Les mesuresdoivent se prendre dans un environmentstable.8. Ne pas laisser tomber le produit ou lesoumettre aux forces externes pendantl’installation ainsi que l’usage.9. Ne mesurez pas la températurecorporelle dans un environment avec defortes interférence électromagnétiques(des exemples incluent des endroitsauprès d’un micro-ondes tandis qu’iltravaille, couisson à induction, ou untéléphone cellulaires en usage) puisquel’interférence EM peut causer des erreursdans le relevé ou même la panne del’appareil.10. Nous suggérons que vous calibriezvotre appareil une fois par mois ou plusfréquemment si votre températureambiante fluctue de plus de 2.0 C (5.6 F).11. Cet appareil a été évalué aux normessemblables à CEI (CommissionÊlectrotechnique Internationale)80601-2-59:2017: Appareilsélectromédicaux -- Part 2-59: Exigencesparticulières de sécurité de base et laperformance essentielle desthermographes pour le dépistage detempérature fébrile humain.Avertissement1. La pile dans cet appareil ne peut pasêtre reparé par l’utilisateur.2. Les relevés du KGP doivent êtreconsidérés comme des valeurs deréférence. A ne pas utiliser les relevés detempérature pour l’autodiagnostic oul’autotraitement. Veuillez chercher leconseil medical professionnel, le caséchéant.3. Il n’existe aucune norme absolue en cequi concerne la température du corpshumain. Il faut connaître la gammenormale de votre propre températurecorporelle pour pouvoir déterminer avecprécision si vous avez la fièvre.4. Avant la prise de température, le frontdu sujet doit être sans sueur, poils, outoute autre obstruction.5. Juste avant de mesurer la températureou pendant la prise de mesure, lesutilisateurs ne doivent pas boire, mangerou ê tre physiquement actifs. Les relevésde température obtenus lorsque le corpsest en état de stabilité et d’équilibre sontplus précis.6. C’est normal que les relevés obtenusdes mesures en continu varient dans unepetite gamme.7

ABOUT MERIDIAN KIOSKSMeridian is a fully integrated manufacturer of indoor and outdoor kiosks, interactivedigital signage, and self-service software. As a complete end-to-end self-serviceinnovator, Meridian develops products and services all under one roof, providinggreater efficiency, and lean, high-quality results.For over two decades, we’ve helped our partners succeed by designing, engineering,manufacturing, and integrating hardware and software solutions from our 13-acreheadquarters in North Carolina.QUALITYOVERSIGHTSCALABILITYFast Facts ISO 9001:2015 Certified 13-Acre Manufacturing Campus Kiosks Deployed Across All IndustriesEFFICIENCY Partners Include HP, Samsung, and Intel Experts in ADA, FCC, and HIPAA Kiosk Financing AvailableCONTACT USLet Meridian’s team of experts guide you through your self-service solution.sales@mzero.com 1 866 454 6757312 S Pine Street,Aberdeen, NC 28315meridiankiosks.com8

REMOTE MANAGEMENT SOFTWARESpecifically designed to integrate with Meridian's temperature screening kiosk,MzeroManage is accessible from any computer connected to the internet and can beused by kiosk administrators to pull lists of temperature scans and view a portal withreal-time updates to ensure compliance.AUTOMATED SMART LOCKERS AVAILABLE!Meridian’s smart lockers provide secure, fully integrated systems to simplify productpickup for contactless rentals, device charging, package drop off and retrieval, andmuch more. Designed with the end-user in mind, electronic locker systems enhance,complement, and expand upon the processes and service that they use and rely onacross a variety of industries.9

Product Name: Personnel Management Kiosk (PMK) Product Type: Indoor Product Model: PMK-001 Thank you for choosing Meridian's Per-sonnel Management Kiosk (PMK). This product uses the thermal image of a person's face to accurately determine a person's skin surface temperature. The PMK features temperature verification