Surface Raceway And Lighting Systems - Tnb.ca.abb

Transcription

H A N G E R A C C E S S O R I E S , S U R FA C E R A C E W AY A N D L I G H T I N G S Y S T E M SA 57—Surface raceway and lighting systemsMaterialSuperstrut electrical raceway, fixture hangingchannel, closure strip and accessories aremanufactured from hot-rolled strip steel.Standard finish for the accessories is GoldGalv .Maximum number of wiresRacewayWiresizeAWGDesign dataDeflections at various hanger rod spacings forraceway channels based on 40 to 45 lb per fixture.DeflectionChannelat 10 ft. (in.)at 12 ft. (in.) 41 83 83A12001C12003A14003at 14 ft. (in.) 2 43 4* 4651061012610364106101058465884634466232223Column A: Suitable for number of wires indicated when used as araceway. Also suitable for number of wires indicated when installed tosupport and supply electrical fixtures when race w ay wiring is suitablefor not less than 75 C.By providing clearance between fixture and raceway of not less than 1 2 in.,where suitable for 60 C may be used.DeflectionChannelWith orwithout KOA1200A1400at 6 ft. (in.) 831at 7 ft. (in.)at 9 ft. (in.) 169 21*Not recommended for this spacing.Electrical racewaySuperstrut channel together with snap-in closurestrip is listed by Un der writ ers Laboratories asa surface metal race way. Other accessories listedby Underwri ters Laboratories are iden ti f ied onthe drawings. 85*Column B: Suitable for number of wires indicated when used as araceway. Also suitable for number of wires indicated when installedto support electrical fixtures when clearance of not less than 1 8 in.is provided between race w ay and fixture and when wiring is suitablefor 75 C.Applicable 1200H1200

S U P E R S T R U T M E TA L F R A M I N GA 58—Surface raceway and lighting systemsFixture fittings1 3 471 4A—01—02—03—04—06—07—08—09—01 802 Raceway joinerwith reinforcing plateFurnished completewith nuts.Cat. no.For channelWt./C lbA802EGA series158B802EGB series112E802EGE series170H802H series182—02 822 Racewayjoiner and sealFurnished completewith 1 4 in. x 5 8 in.machine screws andAB100-1/4 nuts.Cat. no.A822B822—03 A213 Inside joinerFor A1200 serieschannel.Only available inGoldGalv finish.—04 805 End capwith knockoutKO for 1 2 in.conduit. Furnishedcomplete with 1 4 in.x 5 8 in. flat headmachine screw andAB100-1/4 nut.Cat. no.A (in.) For channel Wt./C lb111 16A series75 8B series5672 1 16—05 809 Tapped end cap12 ga. steel. For3 4 in. or 1 in. conduit.Furnished completewith 1 4 in. x 5 8 in. flathead machine screwand AB100-1/4 nut.Rod size—05—06 A853 ChannelhangerUse hanger rod 3 8 in.or 1 2 in. Use with A,AR, B, BR or C seriessingle channel.Wt./C 25 lbFor channelWt./C lbA809-3/4EGA series2E809-3/4EGE series26For channelWt./C lbA805EGA series21H805EGH series31All dimensions shown are in in.—07 A853L Channelhanger – longLong type for allseries channel.Wt./C 48 lb—08 A854 ChannelhangerIllustration showingA854 with nut and boltfurnished to attachto fluorescent fixture.Use with A, B, C orD series channel.Wt./C 34 lb—09 A854L Channelhanger – longIllustration showingA854L with nutand bolt furnishedto attach tofluorescent fixture.Use with E and H serieschannel as well as A, B,C or D series channel.Wt./C 51 lb

S U R FA C E R A C E W AY A N D L I G H T I N G S Y S T E M SA 59—Surface raceway and lighting systemsFixture fittingsPre-galvanized steel closure stripAB844PGCAB844PGCWH White epoxy powder coated44 3 4Plastic closure stripAB844PCAB844PCGYColor: GoldColor: Grey W hen used as a raceway, channel is normallyinstalled with the slot up. After wiring has beencompleted the closure strip is installed. For all channels. Standard length: 10 ft.—01—03—021 1 81 5 8—04—06—051 1 2Stainless steel closure strip1AB844SS6CS1-1/2120 in. (10 feet)Front view0.438"1.7"Side viewNote: Strapping not included.—08 1/32—01 AB803 Cast conduitconnectorTo connect 1 2 in. or 3 4 in.conduit to raceway channel.Furnished complete withstud nuts and hex nuts. Parthas removable bushing toincrease size from 1 2 in. to 3 4 in.Wt./C 60 lb—02 AB815 Swing connectorNuts and bolts to clampto channel is included.For 1 2 in. or 3 4 in. conduit.Wt./C 95 lb—03 AB885 15 SwivelNuts and bolts to clampto channel included.For 1 2 in. or 3 4 in. conduit.Wt./C 25 lb—04 AB867 SpacerFor use with AB866wiring stud nuts.Wt./C 24 lb—05 AB866 Wiring stud nut1 2 in. pipe threadWt./C 21 lb—06 811 Stud nut—07 812 Stud nutFor attaching fixture toslot-down channel or toslot-up knockouts. Specifylength. Hex nut included.Cat. no.812-1EGFor Wt./Cchannellb 4 x 18 4 x 11 49811-1STR811-2STR 321-3/8—07Cat. no.1 3 811All dimensions shown are in in.For Wt./Cchannellb 4 x 11—08 AB868 Fiberretainer for cablesUntil closure strip is In stalledStd. pack 100Wt./C 3 lb6

A60S U P E R S T R U T M E TA L F R A M I N G—Surface raceway and lighting systemsKindorf channel boxes and 8—09—10—11—12—13—01 G2000Finish – GoldGalv Wt./C 110 lb—02 G2001Finish – GoldGalv Wt./C 120 lb—03 G2002Finish – GoldGalv Wt./C 120 lb—04 G2003Finish – GoldGalv Wt./C 130 lb—05 G2004Finish – GoldGalv Wt./C 140 lb—06 G1038 DuplexoutletComplete unitincluding housing,standard duplex3-wire, 15 amp., 125volt, ground receptacleand cover plate.Finish – GoldGalv Wt./C 55 lb—07 G1038ASingle outletComplete unitincluding housing,standard single 3-wire,15 amp., 125 volt,ground receptacleand cover plate.Finish – GoldGalv Wt./C 50 lb—08 G1038DRaceway outletComplete unitincluding housing,duplex, 3-wire, 15amp., 277 volttwistlock receptacleand cover plate.Finish – GoldGalv Wt./C 60 lb—09 G1038ERaceway outletComplete unitincluding housing,single, 3-wire,15 amp., 277 volttwistlock receptacleand cover plate.Finish – GoldGalv Wt./C 50 lb—10 G1038BHousing onlyFinish – GoldGalv Wt./C 25 lb—11 G1038C Duplexcover plateFinish – GoldGalv Wt./C 12 lb—12 G1038CA Singlecover plateSize of opening:1.391 in. diameterFinish – GoldGalv Wt./C 14 lb—13 G1038CX Blankcover plateFinish – GoldGalv Wt./C 15 lb

S U R FA C E R A C E W AY A N D L I G H T I N G S Y S T E M SA61—Surface raceway and lighting systemsKindorf fixture accessoriesG972HB1/2 Steel fixture hanger adapter—G1017 Mercury vapor hangerUsed with channelDepth (in.)Wt./C lb41 476A-1200Finish – GoldGalv The hanger adapter securely mounts the fixture hanger or box to thechannel through the 1 2 in. KO in the base. No special tools are neededfor installation of fittings and fixtures.Superstrut channels, with 1 2 in. KO’s every 6 in., hangs and feedsthe fixtures, thereby simplifying installation.Wt./C 17 lbFinish – GoldGalv 132To support high or low bay mercury vapor or heavy incandescent fixtures-021from raceway channels. Permits plug-in connections with G-1038 1 32Braceway outlets3 1- 32Diagrams3 16314 41DiagramsAB844 Closure stripA1 81 dia. holeCA-12002G-972-1¼2NippleR-1G-972-HB-1/2& G-972-HB-3/4Fixture hangeradapter1 11 16 "4 21 64"3 13 64"Fixturehanger11 1 8 " dia. hole 3 4" KOFixture boxand fixture2"Electrical applicationsA854AB288E145802ES145A1200P

A62S U P E R S T R U T M E TA L F R A M I N G—Surface raceway and lighting systemsElectrical applicationsElectrical l applicationsAB803A853AB885811AB866804

S U R FA C E R A C E W AY A N D L I G H T I N G S Y S T E M SA63—Surface raceway and lighting systemsElectrical applicationsElectrical applicationsA854E145802A1200SElectrical applicationsG1038DG2004G2003A853A854AB844

Fixture hanger adapter Fixture hanger Fixture box and fixture Used with channel Depth (in.) Wt./C lb A-1200 41 4 76 Finish – GoldGalv To support high or low bay mercury vapor or heavy incandescent fixtures from raceway channels. Permits plug-in connections with G-1038 raceway outlets G972HB1/2